Inspection history · 13
1 June 2026
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8385247
2 June 2025
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8149782
20 March 2025
Drydock Extension · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8097426
3 June 2024
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7937566
27 March 2023
Initial Certification · Simplified Stability Test · Plan Review "T" Boat · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7659239
4 November 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7089406
16 October 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6834777
30 November 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6589728
7 September 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6534906
21 June 2017
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6181424
28 November 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6051375
24 October 2016
Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6028207
17 June 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5910392
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2026
Resolved
Stern light not working. REpair/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 4 June 2026
Resolution: Received photo from O/O with new stern light installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2026
Resolved
Trash can is plastic. Provide noncombustible can.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 4 June 2026
Resolution: Received photo from O/O with non-combustible trash can on board.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2026
Resolved
Vessel could not provide current FCC Safety Radio Certificate. Provide Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 4 June 2026
Resolution: Vessel O/O made contact with FCC rep and certificate will be provided in 2 weeks.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 June 2025
Resolved
Child life jacket stowage needs to be lebeled
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2025
Resolved 5 June 2025
Resolution: Stowage labelled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2025
No resolution recorded
FCC Station license
Action required: 705 - Other - as specified
Due 30 June 2025 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 June 2025
Resolved
1st aid kit needs to be refreshed
Action required: 705 - Other - as specified
Due 30 June 2025
Resolved 5 June 2025
Resolution: First aid kit refreshed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 June 2025
Resolved
E/R air dampers need to fit the intake ports.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 June 2025
Resolved 5 June 2025
Resolution: New dampers provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 October 2019
Resolved
A vessel fitted with a submersible electric bilge pump shall have a positive shut off valve at the hull penetration. The vessel currently does not have a shut off valve in the bilge line at the hull penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: A positive shutoff valve was installed in the bilge line at the hull penetration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 October 2019
Resolved
A vessel with an automatic bilge pump must have a visual indicator when the pump is operating at the operating station. The vessels bilge pump indicating light at the operating station is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: The bilge pump indicator light at the operating station was repaired and is functioning properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2019
Resolved
A vessel not required to have a power driven fire pump must have three 2.5 gallon buckets with attached lanyards and the words "FIRE BUCKET" stenciled on each bucket. Vessel currently does not have any fire buckets on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Operator procured and put 03 compliant fire buckets into service on the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019
Resolved
Remote fuel shut off valves must be marked clearly indicating the purpose of valve and direction of operation. Fuel shut off valves marking is not visible from the deck during normal operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: The fuel shutoff valve was properly marked such that it is visible from the deck during normal operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019
Resolved
Vessels must undergo an annual inspection within the 3 months before or after each anniversary date. The vessels COI date is 21 June 2017 and the vessel did not request an inspection until 16 October 2019, past 3 months of the anniversary date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Familiarized operator with existing regulation, endorsed COI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 September 2018
Resolved
A pre-engineered fixed gas fire extinguihsing system must have a means to reset devices used to automatically shut down engines. Engine will not restart after automatically shut down.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2018
Resolved 9 October 2018
Resolution: Override operated properly. Note: the override button must be continously held down until the engine restarts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 September 2018
Resolved
The name of a vessel must be marked in clearly legible letters on life jackets. 05 life jackets are not marked with vessel name. Max count restricted to 18.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2018
Resolved 9 October 2018
Resolution: Life jackets properly labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 September 2018
Resolved
The COI shall be kept on board and shown on demand. The vessel's COI is not on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2018
Resolved 9 October 2018
Resolution: Vessel never received COI. Re-sending COI to owner upon completion of hull exam.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 June 2017
Resolved
Provide emergency instruction list.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 July 2017
Resolution: Provided emergency instruction list.
Documentation › Markings/Placards › Lifejacket Placard
Issued 21 June 2017
Resolved
Provide life jacket donning placard.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 July 2017
Resolution: Provided donning placard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 June 2017
Resolved
Provide first aid kit.
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 21 June 2017
Resolution: Provided first aid kit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 June 2017
Resolved
Prove proper operation of navigation lights. (Restricted to daylight ops only)
Action required: 705 - Other - as specified
Resolved 21 June 2017
Resolution: Proved proper operation of nav lights.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 June 2017
Resolved
Provide current service records for pre-engineered fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Had equipment serviced, provided documentation.
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 November 2016
Resolved
Make raw water sea valve available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Inspected sea valve; all sat.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 28 November 2016
Resolved
Repair or replace STBD fuel tank vent screen.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Replaced vent screen.
Engineering › Steering Gear System › Rudder
Issued 28 November 2016
Resolved
Repair rudder lower post support.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Rudder assembly repaired; all sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 28 November 2016
Resolved
Repair or replace damaged propeller.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2017
Resolution: Propellor professionally repaired; all sat.