MAURY USCG vessel records
← All vessels

CHARLES I

Built
1988
Last inspected
17 November 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 November 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF6090
312752
Flag
UNITED STATES
Maury page id
psix-312752

Documentation record

Registered dimensions (L × B × D)75.5 ft × 16.0 ft × 3.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD W DESMOND · BEVERLY, MA, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 24 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Net Ton
24 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

17 November 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8256584
21 October 2025 Plan Review "T" Boat
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8355136
30 October 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8025909
17 January 2024 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7847512
5 December 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7832366
26 April 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668540
22 December 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7610988
7 April 2022 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7426307
18 November 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7349731
7 October 2020 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7067054
9 July 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7001413
17 October 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6836290
9 January 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6608042
10 December 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6593100
29 November 2018 Deficiency Check · Drydock Extension · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6589694
16 November 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6308241
3 November 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036589
19 October 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6025365

Deficiency record · 21

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 November 2025 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. All of the distress signals on the vessel were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 November 2025
Resolution: Operator replaced the expired signal flares.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 November 2025 No resolution recorded
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's radio did not have the MMSI or GPS input.
Action required: 16 - Rectify deficiencies w/in 14 days
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2024 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MI observed 02 wire nuts used for splicing, not secured with tape or another means, and not made within a junction box. one was located in the "Liquor Void" and the other was in the pilothouse behind the gauge panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 12 November 2024
Resolution: Operator provided photographic evidence that the wire splice had been enclosed in a junction box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 October 2024 Resolved
All piping, valves fittings shall be in accordance with good marine practice and suitable for the purpose intended. MI observed one of the shut off valves at the hose station was cracked and leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 12 November 2024
Resolution: Operator provided photographic evidene that the valve had been replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 October 2024 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI observed 02 wire run terminals on both port and starboard aft bulkhead of the "Liquor Void" that were not made watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 15 November 2024
Resolution: Operator provided photographic evidence that the pipes had been sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. MI observed that 01 ring buoy was missing retroreflective material and 01 ring buoy only had retroreflective material on one side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 12 November 2024
Resolution: Operator provided photgraphic evidence that both ring bouys had new retroreflective tape installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 October 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. MI observed that there were no donning instructions posted for the lifejackets kept on board. There was one placard posted, but it was of a manufacturer that the vessel did not have.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 12 November 2024
Resolution: Operator provided photographic evidence that the appropriate donning instructions had been posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2024 Resolved
Fuel lines shall be ... effectively secured from excessive movement and vibration by the use of non-ferrous metal straps with no sharp edges. MI observed several fuel lines in the engine room secured to the overhead with plastic zip ties.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 12 November 2024
Resolution: Operator provided photographic evidence that the fuel lines had been secured with metal hangers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2024 Resolved
Auxilliary machinery shall be suitable in type and design for the purpose intended. MI observed the hydraulic steering lines below the operating station were not properly supported and sagging significantly, leading to a potential failure of the line and system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 12 November 2024
Resolution: Operator provided photographic evidence that the hydraulic lines had been secured to the overhead.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 January 2024 Resolved
The owner or managing operator must provide satisfactory evidence of the required fire-fighting servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10. 46CFR176.810(b)(2)(iv)
Action required: 10 - Deficiency Rectified
Due 17 January 2024
Resolved 17 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2024 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Wing-nuts were on both MDE battery banks and must be replaced with a permanent type connectors. 46 CFR 183.350(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 6 February 2024
Resolution: Received photos from Rep showing replacement of wing-nuts, see "Deficiencies Documents".
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 January 2024 Resolved
The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. Jacket water leak discovered on generator's intake hose from the heat exchanger. Hose must be tightened or replaced. 46 CFR 182.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 6 February 2024
Resolution: Received photos from Rep showing the placement of hose clamps, see "Deficiencies Documents".
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 December 2022 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q. Life ring was found in poor condition and no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2023
Resolved 3 February 2023
Resolution: New life-ring, lettering, and tape installed onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. One electrical outlet in the engine compartment was missing a conduit plug making it not intrinsically safe. found not intrinslicaly safe
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2023
Resolved 3 February 2023
Resolution: New conduit plug installed making electrical outlet safe in explosive area.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2021 Resolved
A self priming, power driven fire pump must be installed on each vessel of more than 19.8 meters (65 feet) in length. The vessel's fire pump was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2022
Resolution: Received Ovjective evidence that the PTO was fixed and operatioanlly tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 November 2018 Resolved
Wiring joints shall be made mechanically secure and made in junction boxes. Pump connection in fwd void stbd side and connections behind pilothouse panel made with screw caps. 46 CFR 183.05-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2018
Resolved 19 December 2018
Resolution: Screw caps removed and connections made watertight.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 November 2018 Resolved
The fire pump outlet shall be fitted with a pressure gage. Fire pump has no installed gauge. Install pressure gauge on the outlet side. 46 CFR 181.10-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2018
Resolved 27 December 2018
Resolution: New pressure gauge installed
Engineering › Generator (propulsion-electric) › Feeder Circuitry
Issued 16 November 2017 Resolved
Replace generator air feed line.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 11 December 2017
Resolution: Replaced generator air feed line.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 16 November 2017 Resolved
Seperate and label location for the children's life vest storage.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 11 December 2017
Resolution: Seperated and labeled children's life jacket storage.
Stability › Watertight Integrity › General
Issued 16 November 2017 Resolved
Replace gasket on the forpeak hatch and make watertight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 11 December 2017
Resolution: Replaced gasket on forepeak hatch and made watertight.
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 October 2016 Resolved
Found a crack on a hydraulic hose near the fitting on the steering gear. Replace hose and ensure leak free fitting is installed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 3 November 2016
Resolution: Inspected new hoses installed. SAT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.