MAURY USCG vessel records Sign in
← All vessels

SOLANA

SOLANA is a 2001 freight ship. The Coast Guard has recorded 14 inspections since 2002, most recently in July 2017, along with 5 deficiencies and 3 operational controls.

Records from 2002 to 2017. Most recent: inspection, 14 July 2017.

Built
2001
Last inspected
14 July 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9224477 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
GREECE
—
Maury page id
psix-31297

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2002–2017)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it74756 - Dead Weight, Metric Ton
40172 - Regulatory (Subpart C or D), Gross Ton
25434 - Regulatory (Subpart C or D), Net Ton
40172 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

14 July 2017 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6187339
29 July 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5198938
25 July 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5195308
1 February 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4235032
26 February 2010 NPV Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3690360
3 March 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3423100
4 November 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3090061
7 April 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2903486
15 March 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2602967
7 September 2004 ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2188952
7 September 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2189949
14 May 2004 MTSA/ISPS Verification · Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2067301
10 January 2002 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1477634
5 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1478585

Deficiency record · 5

Personnel › Manning/Qualifications › Medical Fitness
Issued 25 July 2015 Resolved
0200: The standards of physical and medical fitness established by the Party shall ensure that seafarers satisfy the following criteria: have no medical condition, disorder or impairment that will prevent the effective and safe conduct of their routine and emergency duties on board;... continued in narrative of Activity# 5195308 STCW 1995 A-1/9 & 74 SOLAS 2014 (Cons.) V/14
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2015
Resolved 27 July 2015
Resolution: Vessel recieved new Chief Engineer to the satisfaction of the Coast Guard.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 1 February 2012 Resolved
The machinery, boilers and other pressure vsl associated piping systems and fittings shall be of design and construction adequate for the service they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and hazards. The jacket water cooling return pipe is wasted and leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2012
Resolution: Received Class report attesting to satisfactory repairs.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 1 February 2012 Resolved
Every steam pipe and every fitting connected thereto which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. Two fittings connected to the boiler were wasted and leaking excessively.
Condition: Improper/Lack of Maintenance
Due 8 February 2012
Resolved 4 February 2012
Resolution: Received Class report attesting to satisfactory repairs.
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 1 February 2012 Resolved
A second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demostrated to be effective. The secondary means of starting the emergency generator, which is hydraulic, is inoperable and not effective in starting the generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2012
Resolution: Received Class report attesting to satisfactory repairs.
Documentation › Certificates/Documents › IOPP Certificate
Issued 15 March 2006 Resolved
0150 Update the IOPP Certificate to include all approved tanks used in the engine room used to receive oil residues, the Waste Oil Settling and Service Tanks and the Bilge Holding Tank are not listed on the IOPP. Marpol 73/78 Annex I/17 action 70C.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2006
Resolution: Received Classification Society Surveyor''s report attesting to the corrections made to the Vessel''s IOPP Certificate. Vessel was issued a new Form A by Class on 24-Nov-05.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.