Behind this panel: 17 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
15 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8127505
10 June 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7931852
30 May 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7923040
23 May 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7695142
15 March 2022
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412479
4 March 2022
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7405922
3 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7213646
9 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7155009
9 June 2020
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6980893
30 March 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6934542
18 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6718034
7 June 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6705505
20 June 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6444984
3 April 2018
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6381820
6 June 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6167411
2 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5896065
22 March 2016
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5839582
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2025
Resolved
Penetrations and openings in watertight bulkheads must- Have means to make them watertight. MI observed that the forward bulkhead in the engine room was not watertight.
46 CFR 171.144(a)
OLD-T
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2025
Resolution: Received documentary evidence of bulkhead penitrations sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2025
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. MI observed that retro was degraded and not fit for service on 07 life jackets. Vessel's manning is reduced 13 adult person on board.
46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 19 May 2025
Resolution: Received documentary evidence of new SOLAS tape installation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. MI observed that the retro on the ring life buoy was not marked with Type II retro-reflective material.
46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 19 May 2025
Resolution: Received documentary evidence of new SOLAS tape installation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 June 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel does not have a FCC Radiotelephony Certificate. Provide Radiotelehony certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2024
Resolution: Received evidence that oeprator received valid cert.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 May 2024
Resolved
Vessel is past dry dock date as of 31MAR24. Issued 835 for vessel to have dry dock exam prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2024
Resolved 4 June 2024
Resolution: MI conducted dry dock exam
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life
46 CFR 180.78(a)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 30 May 2023
Resolution: provided photo evidence of proper lifejacket separation
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 June 2019
Resolved
Vessel's waterlight battery is expired. Provide a new battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2019
Resolved 18 June 2019
Resolution: Vessel provided new, unexpired waterlight batteries.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 June 2019
Resolved
Vessel does not have a lifejacket donning placard. Provide a donning placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2019
Resolved 18 June 2019
Resolution: Vessel provided lifejacket donning placards.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 22 March 2016
Resolved
Cutlass bearing worn beyond servicability, req replacement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 29 April 2016
Resolution: Cutlass bearing has been replaced.
Construction/Loadline › Hull › Keel
Issued 22 March 2016
Resolved
Make repairs to damaged FRP on keel, provide layup schedule prior to completion
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 29 April 2016
Resolution: FRP has been repaired satisfactory.