Records from 1988 to 2004. Most recent: inspection, 1 March 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
1 March 2004
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2012970
18 February 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1747082
10 January 2002
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1477784
24 November 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 435406
7 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 423325
2 November 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409605
16 July 1994
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1382808
18 March 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 832824
3 April 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1262620
16 September 1991
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249719
4 October 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 339711
4 October 1990
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932619
25 July 1989
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1202727
22 July 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 325900
22 July 1988
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033071
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 February 2003
Resolved
Repair self closing door leading into the galley.
Due 18 February 2003
Resolved 18 February 2003
Resolution: New closing device was installed during the inspection.
Construction/Loadline › Structures › Door
Issued 18 February 2003
Resolved
Repair WTD leading from E/R to steering space. (missing dogs, not adjusted)
Due 18 February 2003
Resolved 18 February 2003
Resolution: Corrected during the exam
Pollution Prevention/Response › Prevention Equipment
Issued 10 January 2002
Resolved
EMERGENCY LIGHTERING EQUIPMENT STORED IN FORWARD BOSUN HOLE, SPACE NOT MARKED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 January 2002
Resolution: CORRECTED ON THE SPOT
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 10 January 2002
Resolved
PRESSURE/VACUUM VALVES INOPERATIVE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 January 2002
Resolution: CREW REMOVED AND FIXED ALL DECK P/V VALVES BEFORE INSPECTION ENDED. ALL P/V VALVES TESTED SATISFACTORY.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 January 2002
Resolved
TIDAL CURRENTS FOR VOL. 2 BRITISH ADMIRALITY TIDE TABLES MISSING.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 10 January 2002
Resolution: VESSEL ORDERED TIDAL CURRENTS BEFORE INSPECTION ENDED.
Navigation
Issued 18 March 1993
Resolved
HAVE PROPER REPAIR MADE, TECHNITION TO SEND REPORT TO O.C.M.I. PRIOR TO DEPARTURE GALVESTON LIGHTERING AREA.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Navigation
Issued 18 March 1993
Resolved
MAKE PROPER REPAIR TO ACUROTOS RAM LEAK (SMALL RAM BY TRICK WHEEL) HAVE CLASS INSPECT REPAIR AND SEND REPORT TO O.C.M.I. GALVESTON, PRIOR TO DEPARTURE.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Navigation
Issued 3 April 1992
Resolved
BEFORE RETURNING TO U.S. WATERS PROVIDE, ONBOARD A CORRECTED COMPASS DEVIATION TABLE.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Deck/Cargo
Issued 16 September 1991
Resolved
VESSEL SHALL IMMEDIATELY DEPART U.S. WATERS AFTER COMPLETION OF LIGHTERING OPS (16SEP91). PERMANENT REPAIRS ARE TO BE MADE TO THE VESSELS CARGO PIPINGAND FIREFIGHTING SYSTEM TO THE SATISFACTION OF THE COGNIZANT CLASSIFICATIONSOCIETY. PERMANENT REPAIRS MUST BE MADE PRIOR TO RE-ENTRY TO U.S. WATERS.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Deck/Cargo
Issued 16 September 1991
Resolved
ALTERNATE TRANSFER PROCEDURES TO BE USED FOR ONE TIME ONLY FOR OFF LOAD OF CARGO DUE TO STORM DAMAGE.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Navigation
Issued 25 July 1989
Resolved
CREW NOT FAMILIAR WITH STEERING ARRESTOR SYSTEM OPERATION.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Navigation
Issued 25 July 1989
Resolved
EXHAUST LEAK IN EMERGENCY STEERING DIESEL EXHAUST SYSTEM.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Deck/Cargo
Issued 25 July 1989
Resolved
I.G.S. AUDIBLE ALARMS IN CARGO CONTROL ROOM NOT OPERATING PROPERLY.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989