MAURY USCG vessel records
← All vessels

ZHENHUA 28

Built
1988
Last inspected
18 July 2024
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 July 2024
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8700266
313301
Flag
HONG KONG
Maury page id
psix-313301

Documentation record

Tonnage as PSIX records it12004 - Regulatory (Subpart C or D), Net Ton
12004 - Convention (Subpart B), Net Ton
69341 - Displacement, Ton
47107 - Dead Weight, Ton
40015 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 9 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

18 July 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7956914
5 December 2023 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7833679
26 July 2023 PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7752581
21 July 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7740470
17 October 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6832686
27 February 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6358844
23 February 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6358225
28 March 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6112882
4 August 2016 ISPS II Exam · Ballast Water Examination · COE-Offshore · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5958901

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 October 2019 Resolved
The purpose of this regulation is to contain a fire in the space of origin. The fire integrity of the divisions shall be maintained at openings and penetrations. The Class 'A' bulkhead dividing the Steering Gear Room and main Engine Room space was found with a penetration rendering the prevention of spreading of fire ineffective. 74SOLAS Ch. II-2/ Reg. 9.1.3.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 December 2023
Resolution: RCVD Class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2019 Resolved
Internal combustion engines of a cyliner diameter of 200mm or a crankcase volume of 0.6m3 and above shall be provided with crankcase explosion relief valves of a suitable type with sufficient relief area. The relief valves shall be arranged or provided with means to ensure discharge from them is so directed as to minimize injury to personnel. A crankcase explosion relief valve was found painted over making it ineffective for its intendeed purpose. 74SOLAS Ch. II-1/Reg. 27.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 December 2023
Resolution: RCVD Class report.
Documentation › Logs/Records › Oil Record Book
Issued 27 February 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment, Oil record book entries found with inaccuracies resulting in missing values on the dirty bilge tank.
Action required: 705 - Other - as specified
Resolved 27 February 2018
Resolution: Corrected on the Spot
Navigation › Piloting/Steering › Marine Charts
Issued 4 August 2016 Resolved
1570 NAUTICAL CHARTS AND PUBLICATIONS SUCH AS SAILING DIRECTIONS, LIST OF LIGHTS, NOTICE TO MARINERS, TIDE TABLES AND ALL OTHER NAUTICAL PUBLICATIONS NECESSARY FOR THE INTENDED VOYAGE SHALL BE ADEQUATE AND UP TO DATE. VESSEL DOES NOT HAVE NAUTICAL CHARTS OR PUBLICATIONS FOR GUAM. 74 SOLAS (2014) V/27
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2016
Resolved 10 August 2016
Resolution: Received Class survey and confirmation that adequate charts and publications were delivered to vessel.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 4 August 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2016
Resolved 10 August 2016
Resolution: Received Class survey and confirmation that original Flag endorsements were delivered to vessel and onboard.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 4 August 2016 Resolved
0999 AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. MAIN ENGINE SALT WATER DISCHARGE PIPE AND LUBE OIL HEATER PIPE HAVE TEMPORARY REPAIRS NOT ADDRESSED BY ADMINISTRATION. SOLAS (2014 CONS ED) CH. 1 REG 11b
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2016
Resolution: Received ABS Class survey attesting to satisfactory temp repairs to piping with permanent repairs to be made 30OCT16.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 4 August 2016 Resolved
0715 A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM REQUIRED BY REGULATIONS IN THIS PART SHALL COMPLY WITH THE FIRE SAFETY SYSTEMS CODE. FSS CODE STATES ANY REQUIRED FIXED FIRE DETECTION AND FIRE ALARM SYSTEM WITH MANUALLY OPERATED CALL POINTS SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES. FIRE DETECTOR IN ZONE 11 OF VESSEL IS UNABLE TO BE RESET RENDERING IT INOPERABLE. SEE FORM B
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2016
Resolved 10 August 2016
Resolution: Received Class survey attesting to satisfactory test and operation of fire detector system.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 4 August 2016 Resolved
9900 THE PERSON IN CHARGE OF ANY VESSEL EQUIPPED WITH BALLAST TANKS THAT OPERATES IN THE US MUST REMOVE FOULING ORGANISMS FROM THE VESSEL'S HULL, PIPING, AND TANKS ON A REGULAR BASIS AND DISPOSE OF IT PROPERLY. THE VESSEL HAS EXCESSIVE ALGAE GROWTH THROUGHOUT THE HULL, OBSCURING MARKINGS. 33CFR 151.2050(f)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 August 2016
Resolved 10 August 2016
Resolution: Received Class survey attesting to cleaning of hull around plimsol marks.

Ownership record