Inspection history · 30
12 November 2024
Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8033467
1 February 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7388836
29 October 2021
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7342019
1 October 2021
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7324977
29 September 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7324665
5 October 2020
Permit to Proceed · Examination of Repairs · ACP Drydock Oversight · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7071483
19 August 2020
Type not recorded
No type recorded · Activities Europe · Activity 7073677
8 July 2020
Administrative Inspection
Administrative · Activities Europe · Activity 7002466
25 May 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6960427
1 May 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6948344
24 April 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6943262
10 February 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6905939
4 November 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6848382
17 October 2019
Damage Survey · Examination of Repairs
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6834347
31 July 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6768225
30 March 2019
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6668190
8 January 2019
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6606930
14 December 2018
Administrative Inspection · ACP Drydock Oversight · Drydock Exam · Annual Inspection · Re-Inspection · ACP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6594595
18 April 2018
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6393788
16 March 2018
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6372821
5 December 2017
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6318219
17 October 2017
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6262282
31 May 2017
Type not recorded
No type recorded · Activities Europe · Activity 6165886
4 April 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6117418
4 April 2017
Type not recorded
No type recorded · Activities Europe · Activity 6118034
11 February 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6087119
4 October 2016
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6021492
5 September 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6029753
1 June 2016
ACP Annual Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5933616
11 January 2016
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5794842
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2021
Resolved
Vessel experienced failure in the #1 and #2 PTO while underway resulting in a loss of propulsion. Provide class report attesting to repairs. Vessel is required a tug escort while transiting into Norfolk, VA.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2021
Resolved 4 October 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2021
Resolved
Vessel experienced fire in the AC control panel while underway. Provide class report attesting to the cause of the fire and repairs. Control panel shall remain de-energized until class report is provided.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2021
Resolved 4 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 September 2021
Resolved
Fire-fighting protection systems must be kept in good working order. Fire damper curtain, IWO galley serving line, missing proper quick release hold-back latches. Makeshift brackets installed requiring hand tools for release.
SOLAS 74 (20)II-2/14.2.1.1.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 1 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 September 2021
Resolved
Fire-fighting protection systems must be kept in good working order. Fire damper 1-132-2, located port side stern on house, has wasted knife edge.
SOLAS 74 (20) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 1 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 September 2021
Resolved
Maintenance, testing and inspection of lifesaving equipment shall be carried out in manner having due regard to ensure liability. #3L/B missing water spray nozzle,most forward port tube.
SOLAS 74 (20)III/20.3.1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 1 October 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with provision of the present regulations. EDG has exhaust leak IWO left side manifold. make repair during Dec 29 repair period.
SOLAS 74(20) 1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2021
Resolved 1 October 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with provision of the present regulations. EDG switchboard closures had broken latches and was using Velcro to keep closed.
SOLAS 74(20)1/11(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 1 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 September 2021
Resolved
All lifesaving appliances shall be in good working order and ready for immediate use. Bridge wing quick release smoke buoys not installed IAW manufacturer's instructions (lanyard too short).
SOLAS74 (20)III/20.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
Resolution: Proper length lanyard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 September 2021
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury. Non intrinsically safe electric fans and extension cords installed in paint locker.
SOLAS 74 (79)II-1/45.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 September 2021
Resolution: Items were removed, training was given
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with provision of the present regulations. Steering flat stbd WT door motor housing interferes with manual operation of manual handle located on steering flat side of the door.
SOLAS 74(20) 1/11(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 September 2021
Resolved
Fire-fighting protection systems must be kept in good working order. Five heat and smoke detectors were inoperable or improperly mounted (hanging from wires).
SOLAS 74(20) II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 September 2021
Resolved
he condition of the ship and its equipment shall be maintained to conform with provision of the present regulations. Stbd EOT not annunciating in ECR when receiving orders from bridge.
SOLAS 74(20)1/11(a)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 30 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 September 2021
Resolved
Fire-fighting protection systems must be kept in good working order. Fire damper 1-132-2, located port side stern on house, has wasted knife edge EDG space natural exhaust fire damper could not be dogged closed.
SOLAS 74(20) II-2/14.2.1.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 September 2021
Resolved
Fire-fighting protection systems must be kept in good working order. E/R supply fire damper 06-92-2,was not fully closing.
SOLAS 74(20)II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with provision of the present regulations. EDG had fuel leak IWO f/o pressure sending unit.
SOLAS 74(20)1/11(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 September 2021
Resolved
Fire-fighting protection systems must be kept in good working order. EDG fixed fire-fighting system pull station had broken safety glass.
SOLAS 74(20)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with provision of the present regulations. EDG gauge panel missing hardware and loose.
SOLAS 74(20) 1/11(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 September 2021
Resolved
Fire-fighting protection systems must be kept in good working order ready for immediate use. Multiple E/R fire stations valves and wye gates were seized and not able to be opened.
SOLAS 74(20)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 February 2021
No resolution recorded
Lifeboats #1 and #4 are inoperable and out of service. Vessel is restricted to sailing with a maximum of 69 total persons until proper repairs are made.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 February 2021
No resolution recorded
A total of 141 equipment gauges are out of calibration. Vessel is required to staff a fully manned engine room until all gauges are calibrated and proven operational.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 November 2019
Resolved
Before the ship leaves port, all life saving appliances shall be in working order. Demonstrate that the port rescue boat can achieve adequate speed without alarms when the throttle is engaged. (Vessel has two rescue boats).
Deficiency extended until Feb 26, 2020. Parts on order and will be installed/tested by OEM and witnessed by ABS surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 28 February 2020
Resolution: Rescue boat has been repaired and placed back onboard. Verified via ABS. (Vessel remained at anchor and did not operate past the extended due date of 2/26/2020).
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 November 2019
Resolved
On a Tankship, each cargo tank must be equipped with an overfill device (including an independent audible alarm/visible indicator for that tank) that meets the requirements for tank overfill alarms under 46 CFR 39.2007(d)(3). Vessels cargo tank level indicating system is working intermittently. Demonstrate all cargo tank level alarms comply with regulation.
Other (updated 1/31/2020): Exterior cargo overfill alarms are functioning as designed. Vessel to ensure that when cargo is loaded appropriately qualified personnel are on deck so that alarms can be heard in the even of an overfill.
Action required: 705 - Other - as specified
Due 4 December 2019
Resolved 22 February 2020
Resolution: Received confirmation from ABS that overfill alarms have been repaired and satisfactorily witnessed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 December 2018
Resolved
Prove proper operation of manual remote release for the #3 life boat.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 December 2018
Resolved 15 December 2018
Resolution: Palfanger (Contractor)made necessary adjustments to the #3 Life Boat brake/ manual release and manual lowering of the #3 life boat was demonstrated in the presence of the attening maring inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 December 2018
Resolved
Prove proper start/ stop function of the #4 Life Boat engine.
Action required: 10 - Deficiency Rectified
Due 15 December 2018
Resolved 15 December 2018
Resolution: Vessel crew made adjustments to the throttle control of #4 life boat and proved proper start/ stop function of the engine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 December 2018
Resolved
Repair grab lines on port and starboard side of #3 life boat.
Action required: 10 - Deficiency Rectified
Due 15 December 2018
Resolved 15 December 2018
Resolution: Grab lines were re-fastened to the hull.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 December 2018
Resolved
Remove un-approved MCT fire stop material located in the probe shop with approved type.
Action required: 10 - Deficiency Rectified
Due 15 December 2018
Resolved 15 December 2018
Resolution: Fire stop material was removed and replaced with an approved type.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 December 2018
Resolved
Properly mount portable extinguisher #109 in DFM room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2018
Resolved 19 December 2018
Resolution: Fire extinguisher was properly mounted to the satisfaction of the RO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 December 2018
Resolved
Provide adequate covers for open breaker identified in galley breaker panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 21 December 2018
Resolution: Deficiency cleared to the satisfaction of the ABS.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 December 2018
Resolved
Locate and repair slow coolant leak from #4 life boat engine.
Maintain additional coolant onboard life boat #4.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 21 December 2018
Fire Fighting › Means of Escape › Landings
Issued 26 October 2017
Resolved
Life boat embarcation deck grating not fire or load rated. Grating must be replaced with ABS rated material (or steel as equivilent) to satisfaction of OCMI prior to departure from Subic Bay, PI. Allowed for day trips of less than 24 hours to and return to Subic Bay to accomodate trials and training as long as mitigation procedures remain in place.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2017
Resolved 5 December 2017
Resolution: Cleared. See document Pre-report(WALTER S.DIEHL)