Records from 1991 to 2025. Most recent: inspection, 21 October 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 164
21 October 2025
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8256840
17 October 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8255352
28 September 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8242614
28 September 2025
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8246806
20 September 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8237761
9 August 2025
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8208904
6 May 2025
Re-Inspection · COI Inspection · ACP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8027987
29 June 2024
Annual Inspection · ACP Drydock Oversight · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7944155
2 May 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7949767
6 February 2024
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7864726
21 April 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7680721
7 March 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7646670
1 March 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7643642
26 February 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7651735
14 January 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7623591
9 January 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7618299
9 November 2022
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7591780
11 July 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7559300
29 June 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7490277
26 June 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7542089
14 June 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7536947
9 April 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7427939
17 November 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7352631
17 November 2021
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7353359
5 November 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7347764
23 September 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7318564
24 June 2021
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7234301
19 April 2021
COI Inspection · ACP Drydock Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7178026
11 March 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7154750
15 January 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7125443
27 September 2020
Annual Inspection · ACP Annual Oversight · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7066409
30 April 2020
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6945966
9 April 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6938133
17 March 2020
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6927729
10 March 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6935785
19 February 2020
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6911293
16 January 2020
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6890487
23 December 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6878022
9 September 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6807113
22 July 2019
ACP Periodic Oversight · Periodic Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6680072
18 March 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6640646
28 March 2018
Drydock Exam · ACP Annual Oversight · ACP Drydock Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6380890
12 March 2018
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6370028
19 July 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6329246
30 May 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6162069
18 April 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6126956
27 March 2017
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6111948
24 March 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6117262
8 November 2016
Type not recorded
No type recorded · Activities Europe · Activity 6037251
7 November 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6036486
21 September 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6009257
5 September 2016
Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 5992504
2 June 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5894975
11 April 2016
Administrative Inspection · ACP COI Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5851160
17 February 2016
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5816349
26 November 2015
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5771849
9 October 2015
Administrative Inspection · ACP Periodic Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5739130
5 October 2015
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5739154
15 July 2015
Administrative Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination · ACP Annual Oversight
Physical examination · Activities Europe · Activity 5178469
29 May 2014
ACP Annual Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4870097
25 June 2012
ACP Annual Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4356951
17 May 2012
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4313613
15 May 2012
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4314545
9 August 2011
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4109857
29 November 2010
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3899855
28 November 2010
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4160476
26 October 2010
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3878535
18 October 2010
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3877718
10 October 2010
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 4070876
28 December 2009
Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3655692
9 July 2009
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3529588
8 April 2009
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3448385
9 February 2009
ACP Annual Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3414479
6 February 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3415754
11 December 2008
Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3377953
4 September 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3318053
21 April 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3189197
15 April 2008
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3184195
20 January 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3164615
7 July 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3189562
27 June 2007
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2932903
21 April 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2953488
23 October 2006
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2802621
30 August 2006
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2771993
27 July 2006
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2744527
30 May 2006
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2656252
13 May 2006
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2647628
10 May 2006
Internal Structural Exam · Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2594592
10 May 2006
MTSA/ISPS Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2644068
13 June 2005
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2424017
21 April 2005
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2337128
14 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2333767
2 April 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2576717
29 October 2004
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2246522
25 August 2004
Damage Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2175816
22 July 2004
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2141118
7 July 2004
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2124286
20 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104628
13 June 2004
MARPOL Annex V Examination · Periodic Inspection · MARPOL Annex II Examination · MARPOL Annex I Examination · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2098751
10 February 2004
Type not recorded
No type recorded · Activities Europe · Activity 2004613
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997302
25 November 2003
Hull Examination · In-Service Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1999312
22 November 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2012323
2 April 2003
Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1780155
27 January 2003
Type not recorded
No type recorded · Activities Europe · Activity 1735765
29 August 2002
Deficiency Check · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1669673
25 August 2002
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1760476
23 July 2002
Examination of Repairs
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1650514
14 March 2002
Deficiency Check · Damage Survey · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1609961
5 April 2001
Hull Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1376555
8 January 2001
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 121347
3 July 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1051344
21 June 2000
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1050655
17 April 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048870
5 April 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 6429
29 March 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048432
16 March 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048181
14 March 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406680
5 October 1999
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1452575
28 September 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 101621
28 September 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 155373
12 July 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1418570
4 June 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 811012
16 February 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365058
4 February 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1457628
4 December 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 807925
6 November 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 30863
6 November 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1437494
4 November 1998
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805069
23 March 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 789296
1 December 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1111495
13 June 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1418177
13 May 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 112527
14 February 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394684
18 December 1996
Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1439806
7 August 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1092847
23 July 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1086549
30 May 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1086052
7 May 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445086
25 March 1996
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1079449
15 March 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387962
26 December 1995
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 72021
21 December 1995
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1355705
17 October 1995
Examination of Repairs
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1188630
18 September 1995
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1355438
28 June 1995
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1191341
4 June 1995
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 187165
19 April 1995
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 853731
17 March 1995
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1179082
20 January 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 841922
15 November 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356928
4 June 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 826843
28 April 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1165926
16 November 1993
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 829088
2 June 1993
Deficiency Check · Examination of Repairs · Damage Survey · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356276
17 March 1993
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 859434
17 March 1993
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362735
30 September 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467823
27 July 1992
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1256713
10 April 1992
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1465080
13 March 1992
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1009902
4 March 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1009836
7 November 1991
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384948
18 March 1991
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220860
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 20 July 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working
order and ready for immediate use. Ensure all lifeboat equipment is present and operational. It was noted that the searchlight bulbs are extinguished. Additionally, attending MI's observed 51 punctured lifeboat food rations across all 4 lifeboats. SOLAS III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 July 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Attending MI's noted vent supply closure in 06-92-1 did not close when activated. SOLAS I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 20 July 2025
Resolved
Nautical charts and nautical publications, such as sailing directions, lists of lights, notices to mariners, tide tables and all other nautical publications necessary for the intended voyage shall be
adequate and up to day. Ships bandwidth limitations is preventing underway updating of charts. SOLAS V/27
Action required: 702 - Prior to embarking on international voyage
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program. Additionally master provided an attestation statement stating that they are able to maintain updated charts.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 20 July 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed Attending MI’s tested the overfill and high level alarms, all was satisfactory however it was noted that the local tank TLI’s are all inoperable.
SOLAS I/11(a)
Action required: 705 - Other - as specified
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 July 2025
Resolved
Replace Lifeboat FRP Grating with a compliant F3059-14 ASTM Standard suitable for L2 service. ASTM F3059-14 ENG Policy Ltr 01-18
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 July 2025
Resolved
Emergency lighting shall be provided at every muster and embarkation, in the machinery spaces and main generating stations accommodation alleyways, stairways and exits. Attending MI's noted battle lanterns ship-wide that failed to operate when tested. SOLAS II-1 43.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2025
Resolved
Personal equipment shall consist of the following: An Axe with a handle provided with high-voltage insulation. The required on board FFE’s are missing the small personal equipment Axe as required by the FSS code for the fire-fighter's outfit. SOLAS II-2/10.1 FSS CODE 2.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Accommodation)
Issued 20 July 2025
Resolved
A main electric lighting system which shall provide illumination throughout those parts of the ship
normally accessible to crew shall be supplied from the main source of pwr,MI's noted cracked lighting fixtures. SOLAS II-1/41.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 20 July 2025
Resolved
Emergency escape breathing devices shall comply with the Fire Safety Systems Code. Attending MI's noted that there was an EEBD in the degaussing power supply room 02-84-2 that expired in 2014.
SOLAS II-13/3.4.1
Action required: 10 - Deficiency Rectified
Resolved 21 July 2025
Resolution: Corrected during the COI
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 20 July 2025
No resolution recorded
The certificate of inspection issued by an OCMI to a vessel required to be inspected under 46 USC 3301 specifies the minimum complement of officers and crew necessary fore the safe operation of the vessel. Ships second officer is detaching and there isn't a backfill or a crew member available to fleet up. 46 CFR 15.501 a
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 20 July 2025
Resolved
Companies shall comply with the relevant requirements of part A of the International Safety Management Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The monthly inspection dated 26 June 2025 showed inaccurate food rations in all lifeboats in addition to 51 compromised rations.
74 SOLAS (2009) IX/3.1 ISM Part A 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 July 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. All liferafts onboard were incorrectly installed w/ weak link and hydrostatic release. Configuration and installs shall be corrected prior to vessel movement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2023
Resolution: All weak links and hydrostatic release arrangements verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 July 2023
Resolved
All electrical cables external to equipment shall be at-least of a flame retardant type and shall be so installed as not to impair their original flame-retarding properties. MIs noted chaffing/burn marks on high voltage cabling from MDG #3 and #4. Heat wraps were installed on suspect areas of cabling and RO/ship's crew had no knowledge of repair attempts. RO to investigate current high voltage cabling conditions for suitability of continued use or proposal for authorized repairs prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 July 2023
Resolved
Where "A" class divisions are penetrated, the fire integrity of the boundary shall be maintained via insulation or approved sealing materials to meet boundary rating. MI noted three (03) AC dead end piping penetrating ECR A-60 boundary to main machinery room. Fire boundary shall be maintained and verified by RO prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 July 2023
Resolved
Fire protection systems shall be properly tested/inspected and ready for immediate use. During hydrostatic testing of AFFF hose reels for on-deck protection, all hoses failed testing and require replacement. There are currently no AFFF hose reels available on deck for fire-fighting. New hoses (x8) to be provided at fixed hose reel stations on-deck prior to carriage of cargo and conducting underway replenishment ops.
Action required: 703 - Prior to bunkering operations
Resolved 12 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 July 2023
Resolved
Fire detection systems shall be maintained in working order and ready for use. MIs noted heat detector ivo #4 MDG (ladderwell, above ventilation trunk) that was open with internal wiring exposed. Detector shall be repaired, properly installed, and tested w/ oversight from RO w/in 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: heat detectors repaired and tested
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 July 2023
Resolved
Condition of ship shall be maintained. MIs noted deteriorating motor controller casing and wiring seals on port side (aft station) winch. Satisfactory repairs to exposed casing/wiring required w/in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2023
Resolution: motor casing sealed and inspected
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 27 July 2023
Resolved
Ships above 400 GT shall be fitted with oil filtering equipment. During operational testing of ship's oily water separator (OWS), noted active alarm for recommended replacement of desiccator. OEM shall be consulted as OWS unit was recently serviced and desiccator shall be replaced if recommended by OEM after review of unit conditions. Action to be completed w/in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2023
Resolution: desiccator replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 August 2022
Resolved
Where the emergency source of electrical power may be either a generator, it shall be started automatically upon failure of the main source of emergency electrical power, where the emergency generator is automatically started, it shall be automatically connected to the emergency switchboard. Upon loss of power, the emergency generator automatically started but did not automatically connect to the emergency switchboard until after multiple attempts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2022
Resolution: Upon investigation it was found that the undervoltage relay had failed. The undervoltage relay was subsequently replaced, operationally tested and considered satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 August 2022
Resolved
For a period of 18 hours, emergency lighting in the machinery spaces and main generating stations including their control positions. Found several battle lanterns throughout the engine room inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2022
Resolution: Three (3) battle lanterns ("E" Lights) located at the following locations in the engine room which were found inoperable had their batteries replaced and place back into service to the satisfaction of the attending Surveyor.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 9 August 2022
Resolved
Doors provided to ensure watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge and are also to be operated locally from each side of the bulkhead. Indicators are to be provided at the control position showing whether doors are open or closed, and an audible alarm is to be provided at the door closure. The sliding water tight door # 102 audible alarm is intermittently working when the door is closing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2022
Resolution: The sliding water tight door # 102 audible alarm which was found to be intermittently working when the door is closing has been repaired by cleaning contacts and operationally tested to the satisfaction of the attending Surveyor.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 September 2021
Resolved
No change shall be made to machinery, and other items covered by the survey, without the sanction of the Administration. During a general walkthrough marine inspectors noticed non-metallic/fire retardant hoses on the Emergency diesel generator’s crankcase breathers. Provide documentation with hose type approval suitable for intended location, or replace them as per OEM specifications.
74SOLAS14 I/11.b
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 15 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. 1) Electrical panel 3-64-1 in the engine room is missing numerous dead front type covers that poses and electrical hazard for personnel. 2) Remove/disconnect from wall unapproved wall mounted fan in AFT AFFF or prove that wall mounted fan is properly disconnected from being accidentally energized.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
Resolution: Closed by Sector Guam 16OCT2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2020
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner due regard to ensuring the reliability of fire-fighting systems and appliances. End of J-hook clip attached to fusible link wire above deep fat fryer was inspected in the open position. Correct discrepancy in accordance with manufacturer’s specifications/installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
Resolution: Closed by Sector Guam 16OCT2020.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 September 2020
Resolved
An immersion suit of an appropriate size complying with the requirements of section 2.3 of the Code shall be provided for every person on board the ship. During demonstration of donning immersion suits, two crewmembers were observed wearing their assigned immersion suits that were not of an appropriate size for their height/weight. All persons on board must be provided an appropriate size immersion suit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 September 2020
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Approximately 4” to 5” of water observed in rescue boat engine compartment. Determine cause of water ingress and repair/make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 December 2020
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Replace missing circular cut outs in overhead with openings to piping to as original in crewmember’s ([name withheld]/AB) cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 September 2020
Resolved
Each general emergency alarm signal must be an electronically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. Majority of General Alarms on 01 level, main deck are inoperable. Repair and prove operation of the following general alarms: flight deck, 02 level FWD ladder well inside house, STA 4, 6, 7 ,8, at midship truck tunnel, and aft port side ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 30 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Repair or properly disconnect starboard side shore steam supply connection with missing shut valve on tank deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
Resolution: Refer to Class Report Work Order No.: 4409112
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. 1) Replace missing vent cover for paint locker vent on bow. 2) Repair vent cover for natural supply vent for cylinder store room on bow to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2021
Resolution: Cleared administratively.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 September 2020
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. 1) Ring buoy float lights installed with improper 9 volt battery, 945, that is not listed as one of the batteries per manufacturer’s specifications to ensure the float light will not sink. Replace float light batteries that are “945” with “942”, or contact manufacturer for equivalency in writing. 2) Legibly re-stencil vessel name on ring buoys on level 01 main deck, replace deteriorated reflective SOLAS A tape and weathered/frayed grab lines with new to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Repair the following internal/external lights and prove proper operation: amber light at end of truck tunnel, forward exterior deck light out located at 03 level boat embarkation deck, interior Reefer chill box “locked in” alarm rotating light doesn’t illuminate when activated, and exterior flood lights throughout the ship.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 30 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Various circuits tested UNSAT. Established COMMS for the majority but the “ringer” was non- operational. Repair sound power powered phones at the following locations and prove operation: 12JP, 2JV in motor rooms 1, 2, 3, and 1JV on bow.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 September 2020
Resolved
The electrical power available shall be provided to supply for a period of 18 hours, emergency lighting in the machinery spaces and main generating stations including their control positions. Emergency battle lanterns were found inoperable at the following locations: Multiple lights non-op on motor room ladder wells, 01-97-5 chill box, Crew mess, Repair 2, FWD truck tunnel store rooms, Motor room #1 ladder, Motor room #2 ladder, Motor room #3 ladder, engine room aft of ship service generators, and stbd side passage way by the power operated water tight door.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Replace missing flame screen protector/guard for port side fuel oil service containment vent on 01 level main deck to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
Resolution: Refer to Class Report Work Order No.: 4409112
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2020
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. During per-departure checks vessel experienced port controllable pitch propeller failure. Vessel has no control of the port CPP at engine room control or local engine control, 1 of 2 propulsion shafts OOC.
Action required: 15 - Rectify deficiencies by next port
Due 16 January 2020
Resolved 20 January 2020
Resolution: ABS accepted CG835v and provided finding number 1727.0 see attached report.
Documentation › Certificates/Documents/Licenses › Type Approval Certificate of Incinerator
Issued 17 February 2016
Resolved
It was identified during the administrative inspection that not all crew members on board are in compliance with TWIC requirement. Provide and ensure that all crew members are in compliance with TWIC card requirement.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 6 May 2016
Resolution: All crewmembers have valid TWICs
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 17 May 2012
Resolved
# 3 SSDG mechanical failure. Connecting rod on cylinder B1 fractured and separated from the crankshaft, along with the piston.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 July 2012
Resolution: #3 SSDG overhauled by engine manufacturer technician. Testing procedures submitted to and approved by ABS Houston, and attested to by attending ABS surveyor. #3 SSDG tested satisfactorily under load for 8 hours.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 29 November 2010
Resolved
Aft steering fixed HALON fire system was activated from the pilot cyl (CO2) to the activation stop valve. The HALON cylinders do not appear to have been discharged (guage in green) since the cyl's, time delays, sirens, and pressure swtiches never rcvd the pilot charge due to the stop valve not being opened..
Have aft steering fixed HALON system serviced per mfr recommendations/procedures.
Due 20 December 2010
Resolved 23 March 2011
Resolution: Hiller Fire Service company serviced system, ABS verified completion.
Fire Fighting › Fire Main › Material
Issued 9 February 2009
Resolved
Repair fire main expansion joint bottom through bolt on frame # 46; bolt is broken and needs replacement.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 April 2009
Electrical › Electric Supply System (service) › Cable
Issued 9 February 2009
Resolved
Repair electrical conduit on the # 4 C/T winch located on the junction box; open wire on tank deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 April 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 February 2009
Resolved
DFM valve on frame # 58 has open wires on the tank deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 April 2009
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 9 February 2009
Resolved
Up-date form E on the safety equipment certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2009
Engineering › Generator (propulsion/auxiliary-electric) › Outlet Box
Issued 15 April 2008
Resolved
Repair or replace emergency generator exhaust leak, vessels reps state new part is on order.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 15 April 2008
Resolved
Replace missing bolt stbd mde outboard turbo charger base bolt.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2009
Resolved 11 February 2009
Lifesaving › Lifeboat › Propeller Shaft
Issued 15 April 2008
Resolved
#2 Lifeboat prove proper operation of the vessel gear being engaged, while clutched in the vessel shakes and shimmies.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2009
Lifesaving › Lifeboat › Watertight Enclosure
Issued 10 May 2006
Resolved
Renew all clips and latches for engine covers in all lifeboats, where missing.
Due 10 June 2006
Resolved 30 May 2006
Lifesaving › Rescue Boat › Markings
Issued 10 May 2006
Resolved
Renew Retro-reflective tape for the rescue boat. 46 CFR 199.176
Due 10 June 2006
Resolved 13 May 2006
Resolution: Retro-reflective tape renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 May 2006
Resolved
Install guards for explosion proof lighting in the cargo gas cylinder storeroom to meet original specifications. 46 CFR 111.105-9
Due 10 June 2006
Resolved 31 May 2006
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 10 May 2006
Resolved
Prove proper operation of alarm, audible and visible, for cargo tanks overfill devices. 33 CFR 155.480
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2006
Resolution: Conducted test of newly installed cargo tank overfill devices audible/visual alarm system. Randomly tested twelve (12) of the vsl''s twenty (20) cargo tanks and verified on deck and in the ERC; all sat.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 10 May 2006
Resolved
Provide final hull gauging report to the Coast Guard
Due 10 June 2006
Resolved 10 May 2006
Resolution: Received report for Special Survey Hull no.3.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 10 May 2006
Resolved
Provide AFFF certificate to the Coast Guard
Due 10 June 2006
Resolved 30 May 2006
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 10 May 2006
Resolved
Provide final UT report for the air receivers to the Coast Guard.
Due 10 June 2006
Resolved 10 May 2006
Resolution: Received UT report for the air receivers.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 May 2006
Resolved
Renew MSD tank with the same size and type as original IAW 33 CFR part 159 to the satisfaction of the attending marine inspector.
Due 10 October 2006
Resolved 23 October 2006
Resolution: MSD replaced in kind and IAW 33 CFR 159.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 10 May 2006
Resolved
Make corrections and update periodic safety test procedures IAW 46 CFR part 62 to the satisfaction of the attending marine inspector.
Due 10 August 2006
Resolved 8 August 2006
Resolution: Received and reviewed updated Automation Test Procedures, all sat.
Communications › Alarms/Indicators › General Alarm
Issued 10 May 2006
Resolved
Demonstrate proper indication lights on watertight door control panels on the bridge and ERC.
Due 25 May 2006
Resolved 13 May 2006
Resolution: The problem with the indication lights on watertight door control panel repaired. Re-tested on bridge & ERC, all sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 25 August 2004
Resolved
Small hole penetrating from cargo tank 5C to pumproom. Make permanent repairs at next maintenance availability. Maintain 5C in gas free state. Implement increased monitoring of pumproom atmosphere.
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 2 May 2005
Resolution: Master provided satisfactory evidence of permanent repair and subsequent ABS inspection. All sat.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 June 2004
Resolved
Prove proper operation of gyro input to the two forward radars. The radars are losing stabilization and trip offline every few hours.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 20 June 2004
Resolution: Bridge repeater was replaced. The repeater was feeding back voltage causing the loss of gyro input. Test sat.
Lifesaving › Launching Appliances › Release Mechanism
Issued 13 June 2004
Resolved
Repair/Replace the wire rope coatings for the #2 & #3 lifeboat releasing cables.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 7 July 2004
Resolution: Resolved. Proof of correction provided by vessel''s Chief Mate - P. Morway via email/digital photos.
Lifesaving › Launching Appliances › Davit
Issued 13 June 2004
Resolved
Replace the launching instructions at the embarkation level for #2 & #4 lifeboats.
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 22 July 2004
Electrical › Electric Generation Source (emergency) › Generator
Issued 1 December 2003
Resolved
Demonstrate proper operation of emergency generator prior to leaving port.
Due 1 January 2004
Resolved 31 December 2003
Fire Fighting › Firemans Outfit
Issued 2 April 2003
Resolved
THE MAKO AIR COMPRESSOR O2 SENSER IS BROKE. PROVE PROPER OPERATION OR REMOVE COMPRESSOR. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Due 1 July 2003
Resolved 15 July 2003
Resolution: received e-mail that compressor senser fixed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 23 July 2002
Resolved
Repair/replace faulty HALON propellant charge for Steering Gear Room fixed firefighting system and return system to original operating condition. Vessel's Master to determine and maintain adequate substitute firefighting capabilites for this space until this requirement is satisfied. LEGACY COMPONENT DESC: Tanks
Due 30 August 2002
Resolved 29 August 2002
Resolution: Wittness installing of reapired halon system.
Construction/Loadline › Structures
Issued 14 March 2002
Resolved
Make permanent repairs the to the Bulkhead between the #2S ballast tank and the #3S cargo tank. repairs are to be approved by a CG Marine Inspector. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 31 July 2002
Resolved 29 July 2002
Engineering
Issued 21 June 2000
Resolved
Make permanent repairs to the main salt water cooling pipe to the satisfaction of the attending marine inspector. Vessel is restricted to operations no more than 100 miles from a harbor of safe refuge or within 24hours of suitable tug assist.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 14 March 2000
Resolved
Properly mount foam pump discharge gauge to the satisfaction of the attending marine inspector prior to 02APR00 IAW 46CFR34.20-15(d).
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Electrical
Issued 14 March 2000
Resolved
Provide drip shield for the main switchboard to the satisfaction of the attending marine inspector prior to 14APR00 IAW 46CFR111.01-3.
Condition: Unknown
Due 14 March 2000
Resolved 14 March 2000
Lifesaving
Issued 5 October 1999
Resolved
Make permanent repairs to the #1 lifeboat to the satisfaction of the attending marine inspector prior to 13OCT99.
Condition: Unknown
Due 13 October 1999
Resolved 13 October 1999
Engineering
Issued 6 November 1998
Resolved
Provide approved plans for the newly installed jacket water and oil temp automatic pilot operated systems.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Navigation
Issued 6 November 1998
Resolved
Provide two escort tugs at all times while transiting San Francisco Bay with sufficient ballard pull to maneuver the vessel without power.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Unknown
Issued 6 November 1998
Resolved
Provide fully manned engineroom (1-licensed, 2-unlicensed/wipers) per watchuntil vessel arrives in San Diego and requirement 2 is satisfied, whicheverccurs last.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Lifesaving
Issued 23 March 1998
Resolved
INSTALL GENERAL ALARM BEACON LOWER LEVEL MACHINERY SPACE PORT SIDE IN VICINITY OF OUTBOARD PORT MDE.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Engineering
Issued 23 March 1998
Resolved
DETERMINE CAUSE OF BACKFLASH OF #1 AUXILIARY BOILER; CORRECT AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Electrical
Issued 23 March 1998
Resolved
REPAIR/REPLACE THE HIGH TEMP ALARM ON THE EMERGENCY GENERATOR AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Documentation
Issued 23 March 1998
Resolved
PROPERLY REFERENCE PUBS IN TRANSFER PROCEDURES AND MAKE THEM READILY AVAILABLE TO CREW.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Fire Fighting
Issued 23 March 1998
Resolved
REMOVE HOLD-BACKS FROM FIRE SCREEN DOORS, MANY LOCATIONS THROUGH THE HOUSE.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Electrical
Issued 23 March 1998
Resolved
AT HOTEL LOAD CENTER LC-4 62-1-30, LABEL BREAKERS 6, 11, 12.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Fire Fighting
Issued 23 March 1998
Resolved
PROPERLY CALIBARATE THE FIRE PUMP GAUGE IN FOAM ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Fire Fighting
Issued 23 March 1998
Resolved
FILL AFT FOAM TANK WITH PROPER FOAM, PRIOR TO OPERATION.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Lifesaving
Issued 23 March 1998
Resolved
PROVE PROPER OPERATION OF LIFEBOAT SURVIVAL RADIOS, PRIOR TO OPERATION.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Lifesaving
Issued 23 March 1998
Resolved
REPAIR/REPLACE THE FOLLOWING GENERAL ALARMS BELLS: LOWER AFT MACHINERY SPACE AT FRAME 93 PORT AND 2ND LEVEL MACHINERY SPACE AFT OF PORT MDE TURBO CHARGER.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Unknown
Issued 14 February 1997
Resolved
DEMONSTRATE PROPER LIFT AND BLOWDOWN OF STEAM SUPPLY SAFETY VALVES; BLOWDOWN IS NOT TO EXCEED 4 PERCENT. THIS IS TO BE COMPLETED PRIOR TO THE VESSEL OPERATING.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Construction/Loadline
Issued 18 December 1996
Resolved
COMPLETE INSERT IN AFT BULKHEAD AND TANK TOP IN WAY OF ENGINE CRANKSHAFT ACCESS CUT-OUT IN #10 CENTER CARGO TANK. THIS IS TO INCLUDE NDT OF WELD INPRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Construction/Loadline
Issued 18 December 1996
Resolved
COMPLETE INSERT IN AFT BULKHEAD IN WAY OF ENGINE CRANKSHAFT ACCESS CUT-OUT IN #2 STBD DEEP F/O TANK. THIS IS TO INCLUDE NDT OF WELD IN PRESENCE OF CGINSPECTOR.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Engineering
Issued 23 July 1996
Resolved
PERFORM AUTOMATION TEST IN ACCORDANCE WITH USNS JOHN ERICSSON APPROVED PROCEDURES (EMPHASIS ON STARBOARD ENGINE NOT TESTED DURING MI96008053 INSPECTION) CORRECT PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Documentation
Issued 30 May 1996
Resolved
CONDUCT CREDIT DRYDOCK EXAM PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 30 May 1996
Resolved 30 May 1996
Engineering
Issued 7 May 1996
Resolved
PERFORM AUTOMATION TEST IN ACCORDANCE WITH USNS JOHN ERICSSON APPROVED PROCEDURES (EMPHASIS ON STARBOARD ENGINE NOT TESTED DURING MI96008053 INSPECTION)
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Electrical
Issued 15 March 1996
Resolved
TEST ENGINE ROOM EMERGENCY LIGHTING.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Deck/Cargo
Issued 15 March 1996
Resolved
DEMONSTRATE REFRIGERATION SYSTEM.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Engineering
Issued 15 March 1996
Resolved
TEST OILY WATER SEPERATOR FOLLOWING INSTALLATION OF NEW/REPAIRED SYSTEM MONITOR. DO NOT USE THE OILY WATER SEPERATOR TO DISCHARGE OVERBOARD UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Engineering
Issued 15 March 1996
Resolved
REPAIR PINHOLE LEAK IN STEAM RETURN LINE LOCATED OUTBOARD OF STARBOARD MAINENGINE SHAFT (OVER STARBOARD STERN TUBE PUMPS).
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Engineering
Issued 15 March 1996
Resolved
REPLACE THE RELIEF VALVE WITH AN APPROVED SAFETY VALVE FOR THE LAUNDRY BOILER IAW 46 CFR 54.15-15.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Electrical
Issued 15 March 1996
Resolved
REPAIR WIRE IN MSD ROOM THAT HAS TEMPORARY PATCH ON IT (LABEL PLATE = CCB1PJCCC).
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Electrical
Issued 15 March 1996
Resolved
TEST PTO GENERATORS IN ALL MODES OF OPERATION (PARALLEL, REVERSE POWER RELAY, L/O LOW PRESSURE).
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Navigation
Issued 15 March 1996
Resolved
PROVE PROPER OPERATION OF ADF RECEIVER ON BRIDGE.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Electrical
Issued 15 March 1996
Resolved
REPAIR EMERGENCY LIGHTING FWD OF VESTIBULE 02-109-1.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 15 March 1996
Resolved
CLEAN FLAME SCREEN FOR FUEL OIL STORAGE TANK 5-98-1 VENT AT FLIGHT DECK.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 15 March 1996
Resolved
RENEW FLAME SCREENS IN VENTS FOR: FUEL OIL TANK 5-98-1 (STBD), 5-98-2 (PORT), ENGINE ROOM WASTE HOLDING TANK, AND OILY WASTE TANK.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Navigation
Issued 15 March 1996
Resolved
PROVIDE A CURRENT COMPASS DEVIATION TABLE ON BOARD.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Accommodation/Occupational Safety
Issued 15 March 1996
Resolved
TEST RELIEF VALVES ON ALL PRESSURE VESSELS (AIR FLASKS).
Condition: Unknown
Due 7 August 1996
Resolved 7 August 1996
Engineering
Issued 15 March 1996
Resolved
TEST LOCAL OPERATION OF #3 AND #4 ROCKER ARM PUMPS & STARBOARD MAIN ENGINE L/O PUMPS.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Accommodation/Occupational Safety
Issued 15 March 1996
Resolved
WIRE BRUSH ALL AIR FLASKS BOTH ON DECK AND IN ENGINE ROOM.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Engineering
Issued 15 March 1996
Resolved
TEST CLAYTON BOILER SAFETY VALVES. ENSURE THAT THEY CLEANLY POP AND RESEAT
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Engineering
Issued 15 March 1996
Resolved
REPAIR OIL LEAK ON #4 CONTROLLABLE REVERSE PROPELLER PUMP (AT THE TELLTALE HOLE).
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Fire Fighting
Issued 15 March 1996
Resolved
TEST ENGINE ROOM REMOTE SHUTDOWNS (VENTILATION) AND REMOTE OPERATED VALVES STARBOARD ENGINE.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Unknown
Issued 17 March 1995
Resolved
PROVIDE COPY OF ENGINEERING LOG OF TEST AND REPAIR OF INCINERATOR, AND INCINERATOR ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Unknown
Issued 20 January 1995
Resolved
PROVIDE COPY OF ENGINEERING LOG OF TEST AND REPAIR OF INCINERATOR, AND INCINERATOR ROOM.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Engineering
Issued 20 January 1995
Resolved
PROVIDE COPY OF ENGINEERING LOG OF TEST AND INSTALLATION OF #2 AUXILIARY BOILER.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Electrical
Issued 28 April 1994
Resolved
DEMONSTRATE THAT THE EMERGENCY DIESEL GENERATOR HYDRAULIC STARTING SYSTEM IS CAPABLE OF ACHIEVING SIX START CYCLES.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Navigation
Issued 28 April 1994
Resolved
PROVE PROPER OPERATION OF THE BRIDGE PORT HYDRAULIC PUMP POWER FAILURE ALARM FOR THE STEERING GEAR.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Engineering
Issued 28 April 1994
Resolved
PROVE PROPER OPERATION OF THE PORT AND STBD MAIN DIESEL ENGINE OIL MIST DETECTOR SLOWDOWN ALARMS AND ACTUATE A SLOWDOWN CONDITION.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Fire Fighting
Issued 28 April 1994
Resolved
RENEW AND DEMONSTRATE TEST OF THE FORWARD CARGO STORAGE ROOM HALON SIREN.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Lifesaving
Issued 17 March 1993
Resolved
CONDUCT PROPER WEIGHT TEST OF ALL LIFEBOATS/DAVITS TO SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993