MAURY USCG vessel records
← All vessels

USNS JOHN ERICSSON

Built
1991
Last inspected
21 October 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 October 2025
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8511512
313341
Flag
UNITED STATES
Maury page id
psix-313341

Documentation record

Tonnage as PSIX records it18987 - Regulatory (Subpart C or D), Net Ton
8992 - Convention (Subpart B), Net Ton
27671 - Dead Weight, Ton
42383 - Displacement, Ton
20706 - Regulatory (Subpart C or D), Gross Ton
25742 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 55 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 55

21 October 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8256840
17 October 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8255352
28 September 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8242614
28 September 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8246806
20 September 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8237761
9 August 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8208904
6 May 2025 Re-Inspection · COI Inspection · ACP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8027987
29 June 2024 Annual Inspection · ACP Drydock Oversight · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7944155
2 May 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7949767
6 February 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7864726
21 April 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7680721
7 March 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7646670
1 March 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7643642
26 February 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7651735
14 January 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7623591
9 January 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7618299
9 November 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7591780
11 July 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7559300
29 June 2022 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7490277
26 June 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7542089
14 June 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7536947
9 April 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7427939
17 November 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7352631
17 November 2021 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7353359
5 November 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7347764
23 September 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7318564
24 June 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7234301
19 April 2021 COI Inspection · ACP Drydock Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7178026
11 March 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7154750
15 January 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7125443
27 September 2020 Annual Inspection · ACP Annual Oversight · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7066409
30 April 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6945966
9 April 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6938133
17 March 2020 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6927729
10 March 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6935785
19 February 2020 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6911293
16 January 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6890487
23 December 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6878022
9 September 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6807113
22 July 2019 ACP Periodic Oversight · Periodic Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6680072
18 March 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6640646
28 March 2018 Drydock Exam · ACP Annual Oversight · ACP Drydock Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6380890
12 March 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6370028
19 July 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6329246
30 May 2017 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6162069
18 April 2017 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6126956
27 March 2017 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6111948
24 March 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6117262
8 November 2016 Type not recorded
No type recorded · Activities Europe · Activity 6037251
7 November 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6036486
21 September 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6009257
5 September 2016 Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 5992504
2 June 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5894975
11 April 2016 Administrative Inspection · ACP COI Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5851160
17 February 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5816349

Deficiency record · 37

11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 20 July 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Ensure all lifeboat equipment is present and operational. It was noted that the searchlight bulbs are extinguished. Additionally, attending MI's observed 51 punctured lifeboat food rations across all 4 lifeboats. SOLAS III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 July 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Attending MI's noted vent supply closure in 06-92-1 did not close when activated. SOLAS I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 20 July 2025 Resolved
Nautical charts and nautical publications, such as sailing directions, lists of lights, notices to mariners, tide tables and all other nautical publications necessary for the intended voyage shall be adequate and up to day. Ships bandwidth limitations is preventing underway updating of charts. SOLAS V/27
Action required: 702 - Prior to embarking on international voyage
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program. Additionally master provided an attestation statement stating that they are able to maintain updated charts.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 20 July 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed Attending MI’s tested the overfill and high level alarms, all was satisfactory however it was noted that the local tank TLI’s are all inoperable. SOLAS I/11(a)
Action required: 705 - Other - as specified
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 July 2025 Resolved
Replace Lifeboat FRP Grating with a compliant F3059-14 ASTM Standard suitable for L2 service. ASTM F3059-14 ENG Policy Ltr 01-18
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 July 2025 Resolved
Emergency lighting shall be provided at every muster and embarkation, in the machinery spaces and main generating stations accommodation alleyways, stairways and exits. Attending MI's noted battle lanterns ship-wide that failed to operate when tested. SOLAS II-1 43.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2025 Resolved
Personal equipment shall consist of the following: An Axe with a handle provided with high-voltage insulation. The required on board FFE’s are missing the small personal equipment Axe as required by the FSS code for the fire-fighter's outfit. SOLAS II-2/10.1 FSS CODE 2.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Accommodation)
Issued 20 July 2025 Resolved
A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to crew shall be supplied from the main source of pwr,MI's noted cracked lighting fixtures. SOLAS II-1/41.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 20 July 2025 Resolved
Emergency escape breathing devices shall comply with the Fire Safety Systems Code. Attending MI's noted that there was an EEBD in the degaussing power supply room 02-84-2 that expired in 2014. SOLAS II-13/3.4.1
Action required: 10 - Deficiency Rectified
Resolved 21 July 2025
Resolution: Corrected during the COI
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 20 July 2025 No resolution recorded
The certificate of inspection issued by an OCMI to a vessel required to be inspected under 46 USC 3301 specifies the minimum complement of officers and crew necessary fore the safe operation of the vessel. Ships second officer is detaching and there isn't a backfill or a crew member available to fleet up. 46 CFR 15.501 a
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 20 July 2025 Resolved
Companies shall comply with the relevant requirements of part A of the International Safety Management Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The monthly inspection dated 26 June 2025 showed inaccurate food rations in all lifeboats in addition to 51 compromised rations. 74 SOLAS (2009) IX/3.1 ISM Part A 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2025
Resolution: ABS class society has assumed responsibility for this outstanding deficiency. Vessel is enrolled under the ACP program.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 July 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. All liferafts onboard were incorrectly installed w/ weak link and hydrostatic release. Configuration and installs shall be corrected prior to vessel movement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2023
Resolution: All weak links and hydrostatic release arrangements verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 July 2023 Resolved
All electrical cables external to equipment shall be at-least of a flame retardant type and shall be so installed as not to impair their original flame-retarding properties. MIs noted chaffing/burn marks on high voltage cabling from MDG #3 and #4. Heat wraps were installed on suspect areas of cabling and RO/ship's crew had no knowledge of repair attempts. RO to investigate current high voltage cabling conditions for suitability of continued use or proposal for authorized repairs prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 July 2023 Resolved
Where "A" class divisions are penetrated, the fire integrity of the boundary shall be maintained via insulation or approved sealing materials to meet boundary rating. MI noted three (03) AC dead end piping penetrating ECR A-60 boundary to main machinery room. Fire boundary shall be maintained and verified by RO prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 July 2023 Resolved
Fire protection systems shall be properly tested/inspected and ready for immediate use. During hydrostatic testing of AFFF hose reels for on-deck protection, all hoses failed testing and require replacement. There are currently no AFFF hose reels available on deck for fire-fighting. New hoses (x8) to be provided at fixed hose reel stations on-deck prior to carriage of cargo and conducting underway replenishment ops.
Action required: 703 - Prior to bunkering operations
Resolved 12 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 July 2023 Resolved
Fire detection systems shall be maintained in working order and ready for use. MIs noted heat detector ivo #4 MDG (ladderwell, above ventilation trunk) that was open with internal wiring exposed. Detector shall be repaired, properly installed, and tested w/ oversight from RO w/in 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: heat detectors repaired and tested
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 July 2023 Resolved
Condition of ship shall be maintained. MIs noted deteriorating motor controller casing and wiring seals on port side (aft station) winch. Satisfactory repairs to exposed casing/wiring required w/in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2023
Resolution: motor casing sealed and inspected
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 27 July 2023 Resolved
Ships above 400 GT shall be fitted with oil filtering equipment. During operational testing of ship's oily water separator (OWS), noted active alarm for recommended replacement of desiccator. OEM shall be consulted as OWS unit was recently serviced and desiccator shall be replaced if recommended by OEM after review of unit conditions. Action to be completed w/in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2023
Resolution: desiccator replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 August 2022 Resolved
Where the emergency source of electrical power may be either a generator, it shall be started automatically upon failure of the main source of emergency electrical power, where the emergency generator is automatically started, it shall be automatically connected to the emergency switchboard. Upon loss of power, the emergency generator automatically started but did not automatically connect to the emergency switchboard until after multiple attempts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2022
Resolution: Upon investigation it was found that the undervoltage relay had failed. The undervoltage relay was subsequently replaced, operationally tested and considered satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 August 2022 Resolved
For a period of 18 hours, emergency lighting in the machinery spaces and main generating stations including their control positions. Found several battle lanterns throughout the engine room inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2022
Resolution: Three (3) battle lanterns ("E" Lights) located at the following locations in the engine room which were found inoperable had their batteries replaced and place back into service to the satisfaction of the attending Surveyor.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 9 August 2022 Resolved
Doors provided to ensure watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge and are also to be operated locally from each side of the bulkhead. Indicators are to be provided at the control position showing whether doors are open or closed, and an audible alarm is to be provided at the door closure. The sliding water tight door # 102 audible alarm is intermittently working when the door is closing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2022
Resolution: The sliding water tight door # 102 audible alarm which was found to be intermittently working when the door is closing has been repaired by cleaning contacts and operationally tested to the satisfaction of the attending Surveyor.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 September 2021 Resolved
No change shall be made to machinery, and other items covered by the survey, without the sanction of the Administration. During a general walkthrough marine inspectors noticed non-metallic/fire retardant hoses on the Emergency diesel generator’s crankcase breathers. Provide documentation with hose type approval suitable for intended location, or replace them as per OEM specifications. 74SOLAS14 I/11.b
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 15 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. 1) Electrical panel 3-64-1 in the engine room is missing numerous dead front type covers that poses and electrical hazard for personnel. 2) Remove/disconnect from wall unapproved wall mounted fan in AFT AFFF or prove that wall mounted fan is properly disconnected from being accidentally energized.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
Resolution: Closed by Sector Guam 16OCT2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2020 Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner due regard to ensuring the reliability of fire-fighting systems and appliances. End of J-hook clip attached to fusible link wire above deep fat fryer was inspected in the open position. Correct discrepancy in accordance with manufacturer’s specifications/installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
Resolution: Closed by Sector Guam 16OCT2020.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 September 2020 Resolved
An immersion suit of an appropriate size complying with the requirements of section 2.3 of the Code shall be provided for every person on board the ship. During demonstration of donning immersion suits, two crewmembers were observed wearing their assigned immersion suits that were not of an appropriate size for their height/weight. All persons on board must be provided an appropriate size immersion suit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 September 2020 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Approximately 4” to 5” of water observed in rescue boat engine compartment. Determine cause of water ingress and repair/make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 December 2020
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Replace missing circular cut outs in overhead with openings to piping to as original in crewmember’s ([name withheld]/AB) cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 September 2020 Resolved
Each general emergency alarm signal must be an electronically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. Majority of General Alarms on 01 level, main deck are inoperable. Repair and prove operation of the following general alarms: flight deck, 02 level FWD ladder well inside house, STA 4, 6, 7 ,8, at midship truck tunnel, and aft port side ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 30 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Repair or properly disconnect starboard side shore steam supply connection with missing shut valve on tank deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
Resolution: Refer to Class Report Work Order No.: 4409112
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. 1) Replace missing vent cover for paint locker vent on bow. 2) Repair vent cover for natural supply vent for cylinder store room on bow to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2021
Resolution: Cleared administratively.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 September 2020 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. 1) Ring buoy float lights installed with improper 9 volt battery, 945, that is not listed as one of the batteries per manufacturer’s specifications to ensure the float light will not sink. Replace float light batteries that are “945” with “942”, or contact manufacturer for equivalency in writing. 2) Legibly re-stencil vessel name on ring buoys on level 01 main deck, replace deteriorated reflective SOLAS A tape and weathered/frayed grab lines with new to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Repair the following internal/external lights and prove proper operation: amber light at end of truck tunnel, forward exterior deck light out located at 03 level boat embarkation deck, interior Reefer chill box “locked in” alarm rotating light doesn’t illuminate when activated, and exterior flood lights throughout the ship.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 30 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Various circuits tested UNSAT. Established COMMS for the majority but the “ringer” was non- operational. Repair sound power powered phones at the following locations and prove operation: 12JP, 2JV in motor rooms 1, 2, 3, and 1JV on bow.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 September 2020 Resolved
The electrical power available shall be provided to supply for a period of 18 hours, emergency lighting in the machinery spaces and main generating stations including their control positions. Emergency battle lanterns were found inoperable at the following locations: Multiple lights non-op on motor room ladder wells, 01-97-5 chill box, Crew mess, Repair 2, FWD truck tunnel store rooms, Motor room #1 ladder, Motor room #2 ladder, Motor room #3 ladder, engine room aft of ship service generators, and stbd side passage way by the power operated water tight door.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Replace missing flame screen protector/guard for port side fuel oil service containment vent on 01 level main deck to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
Resolution: Refer to Class Report Work Order No.: 4409112
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2020 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. During per-departure checks vessel experienced port controllable pitch propeller failure. Vessel has no control of the port CPP at engine room control or local engine control, 1 of 2 propulsion shafts OOC.
Action required: 15 - Rectify deficiencies by next port
Due 16 January 2020
Resolved 20 January 2020
Resolution: ABS accepted CG835v and provided finding number 1727.0 see attached report.
Documentation › Certificates/Documents/Licenses › Type Approval Certificate of Incinerator
Issued 17 February 2016 Resolved
It was identified during the administrative inspection that not all crew members on board are in compliance with TWIC requirement. Provide and ensure that all crew members are in compliance with TWIC card requirement.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 6 May 2016
Resolution: All crewmembers have valid TWICs

Ownership record