MAURY USCG vessel records Sign in
← All vessels

USNS LEROY GRUMMAN

USNS LEROY GRUMMAN is a 1989 tank ship. The Coast Guard has recorded 167 inspections since 1989, most recently in February 2026, along with 183 deficiencies and 1 operational control.

Records from 1989 to 2026. Most recent: inspection, 9 February 2026.

Built
1989
Last inspected
9 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8511500 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
313342
Flag
UNITED STATES
—
Maury page id
psix-313342

Inspections, by type

…with no type recorded46
Years with a record 35 calendar years (1989–2026)
The 167 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8992 - Convention (Subpart B), Net Ton
18987 - Regulatory (Subpart C or D), Net Ton
27671 - Dead Weight, Ton
42383 - Displacement, Ton
25742 - Convention (Subpart B), Gross Ton
20706 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 167

9 February 2026 ACP Annual Oversight · Annual Inspection · Vessel Attendance
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8308009
21 December 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8286186
15 December 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8284025
12 November 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8267173
29 October 2025 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8260337
24 March 2025 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8098745
29 January 2024 ACP Drydock Oversight · Examination of Repairs · Deficiency Check · ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7861746
23 January 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7853183
14 November 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7824784
23 September 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7797015
12 May 2023 Administrative Inspection · Damage Survey · In-Service Inspection
Physical examination · Activities Europe · Activity 7691937
25 April 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7675616
25 March 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7656880
13 January 2023 ACP Annual Oversight · Administrative Inspection · ACP Additional Oversight – Risk Assessment · Examination of Repairs · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7621188
30 November 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7602619
20 July 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7511593
9 May 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7446802
26 April 2022 ACP COI Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7434524
13 November 2021 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7350966
1 November 2021 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7343029
5 October 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7327685
29 September 2021 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7323275
3 September 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7303379
28 July 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7271438
26 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7238702
23 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7238671
1 March 2021 Administrative Inspection · ACP Drydock Oversight · ACP Annual Oversight · ACP Additional Oversight – Risk Assessment · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7185431
12 December 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7112663
11 December 2020 Type not recorded
No type recorded · Activities Europe · Activity 7111258
23 October 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7084113
21 October 2020 Type not recorded
No type recorded · Activities Europe · Activity 7092720
19 October 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7084160
12 March 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6898886
9 December 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6870084
4 December 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6867369
23 November 2019 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6861920
11 October 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6833637
5 October 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6828710
5 October 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6828764
24 September 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6819576
19 September 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6815799
16 September 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6813883
10 September 2019 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6808852
5 September 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6804965
6 August 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6774197
18 March 2019 Periodic Inspection · ACP COI Oversight · Administrative Inspection · ACP Drydock Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6641564
14 September 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6542427
26 March 2018 ACP Annual Oversight · Administrative Inspection · Deficiency Check · Annual Inspection · Special
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6378702
25 January 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6343977
23 January 2018 Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 6341894
21 January 2018 Type not recorded
No type recorded · Activities Europe · Activity 6341226
16 November 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6307801
8 June 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6169218
12 May 2017 Annual Inspection · ACP COI Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6138678
14 December 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6057518
2 December 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6051779
16 November 2016 In-Service Inspection · Administrative Inspection
Physical examination · Activities Europe · Activity 6042034
10 November 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6039105
29 July 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5961783
2 May 2016 ACP Annual Oversight · ACP Periodic Oversight
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5875994
25 March 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5915637
12 May 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4857173
6 July 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4373231
13 June 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4344154
1 February 2012 Administrative Inspection · ACP Annual Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4236131
12 January 2012 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4226975
30 September 2011 Type not recorded
No type recorded · Activities Europe · Activity 4159550
12 August 2011 Type not recorded
No type recorded · Activities Europe · Activity 4120368
22 February 2011 Administrative Inspection · ACP Annual Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3952581
3 January 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3919765
1 January 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3925069
1 January 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3925094
23 December 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3915443
5 February 2009 ACP COI Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3413050
29 April 2008 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3194463
14 June 2007 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2977489
12 April 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2906555
12 April 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2906560
30 March 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2861634
29 March 2007 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2897727
30 January 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2863841
16 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2392314
27 January 2005 Annual Inspection · Ballast Water Examination · MTSA Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2281520
7 September 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2223815
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104675
25 May 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2077921
26 April 2004 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2105969
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997411
25 November 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1954487
4 November 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1941922
27 October 2003 Administrative Inspection
Administrative · Activities Europe · Activity 1936611
17 October 2003 Administrative Inspection
Administrative · Activities Europe · Activity 1930243
7 July 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1875098
2 June 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1808470
2 April 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1766902
3 January 2003 Type not recorded
No type recorded · Activities Europe · Activity 1726812
18 October 2002 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1692218
24 May 2002 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1620563
21 May 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1619054
1 April 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1599573
26 February 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1489434
23 January 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1480764
15 January 2002 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1478715
10 January 2002 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1477271
9 January 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1478303
26 December 2001 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1473837
18 October 2001 Type not recorded
No type recorded · Activities Europe · Activity 1597534
4 May 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1064085
27 April 2001 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373500
23 February 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1059453
17 February 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 149197
2 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1379295
9 September 2000 Type not recorded
No type recorded · Activities Europe · Activity 31583
8 May 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 817567
24 January 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1391191
16 November 1999 Type not recorded
No type recorded · Activities Europe · Activity 808291
21 September 1999 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1064532
2 March 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 799045
11 February 1999 COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1451371
4 December 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 807040
10 November 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112453
6 August 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1131368
10 July 1998 Administrative
Administrative · Activities Europe · Activity 796537
9 March 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460154
22 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1114952
20 August 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1121950
17 June 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1113675
21 February 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1091959
9 January 1997 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1098008
22 November 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1396622
7 June 1996 Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 872545
7 June 1996 Administrative
Administrative · Activities Europe · Activity 873661
21 February 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 62373
29 December 1995 Re-Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1355605
18 September 1995 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1383054
16 January 1995 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1403885
2 December 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 871203
5 August 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1377246
9 March 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856016
15 February 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1163778
14 May 1993 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962855
10 May 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1141076
30 March 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1144068
30 March 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1144619
21 March 1993 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1148570
13 November 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 961579
21 October 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1253311
10 September 1992 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 932407
10 June 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 953082
18 May 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1254680
8 April 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 947914
3 February 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 954162
28 January 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1267579
20 December 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1265717
9 December 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 948863
5 December 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258143
11 October 1991 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 935301
25 July 1991 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248037
4 June 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 220565
15 November 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 929023
26 October 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 916358
3 August 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1226813
13 July 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1222097
30 June 1990 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 900111
7 February 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1223625
2 August 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916864
2 August 1989 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1344315

Deficiency record · 183

11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 1 May 2026 Resolved
Each survival craft shall be stowed in a state of continuous readiness so that two crew members can carry out preparations for embarkation and launching in less than 5 minutes. When launching from inside the #2 lifeboat, the dead man switch got stuck up and continued to pay out the falls without tension being applied to the cable.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2026
Resolution: The lifeboat was raised and lowered multiple times in the presence of CG MI's, RO, and OEM and the problem did not repeat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 1 May 2026 Resolved
An immersion suit shall be constructed with waterproof materials such that it can be unpacked and donned without assistance within 2 minutes. 08 crew members were unable to don immersion suits within 2 minutes.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2026
Resolution: All 8 crew members were retested and were able to meet the required timeline.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 December 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported fuel in the crankcase oil of the EDG. 74 SOLAS (24) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 December 2025 Resolved
The vessel is required a tug escort throughout its transit within the Port of Virginia or until the emergency diesel generator is repaired to the satisfaction of the attending Coast Guard Marine Inspector. The number of tugs, horsepower, and bollard pull shall be determined adequate by the [name withheld] the vessel experiences any propulsion or steering issues while underway you are to follow Coast Guard casualty reporting requirements. 33 CFR 160.111(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2025
Resolution: EDG fixed, tug escort no longer required.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 25 July 2025 Resolved
Each survival craft shall be stowed .4 fully equiped as required by this chapter and the code. IV 4.4.7.9lifeboats intended for launching down the side of a ship shall have skates and fenders. All life baots are missing skates.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2025
Resolved 4 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 July 2025 Resolved
reg 58 openings shall be provided with permently attached means of closing which shall be atleast as effective for resisting fires as the divisions in which they are fitted. L Landry room doors self closures were removed and galley door self closure was inopperative.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2025
Resolved 4 August 2025
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 July 2025 Resolved
reg 58 in addition to complying with the specific provisions for fire integrity of bulkheads and decks of tankers. Electrician shop has multiple holes in a class bhd iwo both doors and wire passed through hole in corner.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2025
Resolved 4 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 July 2025 Resolved
(1997) II-2 reg 58 in approving structral fire protection, the admistration shall have reguard to the risk of heat transmission. SFP missing in overhead of electricians shop near previuos vent repair
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2025
Resolved 4 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 July 2025 Resolved
1997 II-2 Reg 16 the ducts are fitted with automatic fire dampers close to the boundries penatrated. Fire damper on tank deck 2-60-1 with remore closure did not operate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2025
Resolved 4 August 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 July 2025 Resolved
1997 II-2 reg 28 below the bulkhead deck two means of escape shall be provided. Nixie room and fire marshal locker emergency escape were frozen shut, crew was able to free them up and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2025 Resolved
1997 II-2 reg 17 firemens outfits or sets of personal equipment shall be stored as to be easily accessible and ready for use. SCBA bottle was only 1/4 full and firemens helmet had 2 holes drilled in it. Both were replaced on the spot and removed from service.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 March 2025 Resolved
With the exception of the survival craft referred to in regulation 16.1.1, all survival craft required to provide for the abandonment of by the total number of persons on board shall be capable of being launched with their full complement of persons and equipment within a period of 10 min from the time the abandon ship signal is given. MI observed that neither stbd side life boats were capable of being launched. 17ac 74 SOLAS (2020) III/31.1.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2025
Resolution: MI observed launching of stbd side lifeboats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 March 2025 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. MI observed that the number four, port side lifeboat would not start. 17ac 74 SOLAS (2020) III/20.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2025
Resolution: MI observed launching of port side lifeboats and operation of #4 lifeboat for 10 continuous minutes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 24 March 2025 Resolved
Each davit launched lifeboat must have two buoyant smoke signals. MI observed that both port side lifeboats had one buoyant orange smoke. 74 SOLAS (2020) III/34 LSA 4.1.5.1.12 10c
Action required: 10 - Deficiency Rectified
Resolved 25 July 2025
Resolution: An additional buoyant orange smoke signal was added to each lifeboat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 March 2025 Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. MI observed a fault in zone 13 on the fire detection panel on the bridge. 74 SOLAS (1997) II-2/13.1.1 10c
Action required: 10 - Deficiency Rectified
Resolved 25 July 2025
Resolution: Fault was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI observed that the non-follow up steering had a 20 degree overrun. 74 SOLAS (1997) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2025
Resolved 4 August 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 August 2024 Resolved
All ships shall be sufficiently abd efficiently manned. Vessel was not fully manned, verification of full crew mmc, and medical card required prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2024
Resolution: Full crew MMC and medical certifcates verified.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 August 2024 Resolved
When a ship enters service for the first time, or when a new crew is engaged, abandon ship and fire drills shall be held before sailing. Satisfactory drills shall be conducted in the presence of MI prior to departure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2024
Resolution: Conducted satisfactory drills once fully crewed.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 19 May 2023 Resolved
The Administration shall ensure that radio equipment required by this chapter is maintained to provide the availability of the functional requirements specified in regulation 4. Vessel lost communications during voyage. Make appropriate repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2023
Resolved 22 May 2023
Resolution: MIs verified on board that all communications equipment required by SOLAS and CFR were operational and failure was part of MSC/Navy Comms equipment.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2023 Resolved
Oil fuel pipes and their valves and fittings shall be of steel or other approved material, except that restricted use of flexible pipes shall be permissible in positions where the Administration is satisfied that they are necessary. Such flexible pipes and end attachments shall be of approved fire-resisting materials of adequate strength and shall be constructed to the satisfaction of the Administration. Flexible joint off fuel oil valve on port main engine failed. Make permanent repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2023
Resolved 25 May 2023
Resolution: Received ABS class report attesting to proper repair, testing, and operation of fuel oil piping/valves.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2023 Resolved
The arrangements for distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. The arrangements made in machinery spaces of category A shall at least comply with the provisions of paragraph 15.2.8. 02 lube oil flex joints failed or failing on both main engines. Make permanent repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2023
Resolved 25 May 2023
Resolution: Received ABS class report attesting to proper repair, testing, and operation of lube oil joints.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel's #4 SSDG is inoperable due to a failure in the starting system. 74 SOLAS (20) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2023
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2023 Resolved
A minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried on board. Those two-way portable radiotelephone apparatus shall be of an explosion-proof type or intrinsically safe. Ships constructed before 1 July 2014 shall comply with the requirements of this paragraph not later than the first survey after 1 July 2018. Vessel did not have intrinsically safe radios for the fire team.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Search light sockets did not work properly to keep light on when in use.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 13 March 2023 Resolved
Liferafts intended for throw-overboard launching shall be so stowed as to be readily transferable for launching on either side of the ship unless liferafts, of the aggregate capacity required by regulation 31.1 to be capable of being launched on either side, are stowed on each side of the ship. The forward 25-man liferaft, due to its size, it not readily launchable on either side of the fo'c'sle.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 13 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The aft hazmat locker exhaust ventilation fan was found to be inoperable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 March 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 April 2022 Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including protection of openings. Engine room fire dampers 06-92-2, 06-92-1 and 07-29-2 do not properly close. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Witnessed operation of all engine room Supply and Exhaust fire dampers; all sat.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 April 2022 Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including protection of openings and penetrations in fire-resisting divisions. Cable penetrations, in way of radars, on the bridge, either has mixed materials in the same penetration or are missing approved material. Vessel shall ensure Coast Guard Marine Inspectors and Class Surveyors are both present prior to closing, sealing, and completing the first MCT penetration. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2022
Resolution: Accepted as a condition of Class and closed by CG deficiency check (see Activity 7446802).
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 April 2022 Resolved
All lifesaving equipment shall be in good working order and ready for immediate use. Missing one sealed battery for lifeboat portable radio. 74 SOLAS (20) III/20.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 April 2022 Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including protection of openings. Ventilation fire damper enclosure 06-84-5 is wasted and holed. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2022 Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including protection of openings. Scullery fire curtain 1-110-1 will not close and latch. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2022 Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs,including protection of openings. Stairtower fire doors 1-69-0 and 06-69-1 will not self-close and latch. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 26 April 2022 Resolved
Required life-saving appliances and arrangements shall be approved by the Administration. All lifeboat water provisions were not Coast Guard approved. 74 SOLAS (97) III/4.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The fantail escape scuttle 1-146-0 will not dog closed. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Ventilation closures on bow have missing/broken dogs. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 April 2022 Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the Organization. Berthing PFD and immersion suit storage lockers are not marked. 74 SOLAS (20) III/20.10
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Hydraulic ram for aft port WTD, to steering flat, has a fluid leak. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2022
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 26 April 2022 Resolved
Lifesaving appliances and arrangements are required to be approved by the Administration. The smoke buoys, located on the bridge wings, are not Coast Guard approved. 74 SOLAS (97) III/4.1
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Smoke buoys replaced with Coast Guard approced devices.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. EOT, for port engine, does not have audible bell at, both, the bridge and ECR locations. 74 SOLAS(20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: EOT audible alarm tested while on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 April 2022 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Chief Engineer does not possess a current medical certificate.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Documents of new Chief Engineer verified.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Supplemental warning beacons, for General Alarm, in motor room inop. 74 SOLAS(20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Alarm witnessed by inspection team.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 April 2022 Resolved
Each tankship must be equipped with overfill device, including an independent audible and visual indicator that meet requirements of 46 CFR 39.2007. The high level audible alarm, for forward station, is inoperative.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Alarm witnessed by inspection team.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 April 2022 Resolved
Each tankship must be equipped with overfill device, including and independent audible and visual indicator that meet requirements of 46 CFR 39.2007. The center alarm station, on cargo tank top deck, is not labeled.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Alarm witnessed by inspection team.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 April 2022 Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including protection of openings. Ventilation fire damper closure 06-97-1 will not close. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Closure of dampers witnessed by inspection team.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 September 2021 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Received notification of failure of both port side life boats. Provide classification report attesting to repairs or corrective actions taken. SOLAS 74 (2020 Cons.) I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 December 2019 Resolved
Vessel Port steering pump malfunctions when at left hard rudder.Vessel shall be escorted by a minimum of one or two tugs that's satisfies one of the following; One tug at least 3000 horsepower or greater, or Two tugs of 2000 horsepower or greater or one tug of 40 bollard pull or greater or two tug of 40 aggregate bollard pull or greater
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2019
Resolved 13 December 2019
Resolution: Nav Systems Tech attended vessel for repair. ABS Surveyor found steering gear function restored to operable condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 December 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel Port steering pump malfunctions when at left hard rudder. 74 SOLAS (14) I/11(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2019
Resolved 13 December 2019
Resolution: Nav Systems Tech attended vessel for repair. ABS Surveyor found steering gear function restored to operable condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2019 Resolved
Vessel self-reported an issue with bridge control of main propulsion. Bridge control would switch to local control without human intervention. Vessel shall be escorted by a minimum of one or two tugs that satisfies one of the following: One tug at least 3,000 horsepower or greater; or, Two tugs of 2,000 horsepower or greater; or, One tug of 40 ton bollard pull or greater; or, Two tugs of 40 aggregate bollard pull or greater. (33 CFR 160.111)
Action required: 705 - Other - as specified
Due 24 September 2019
Resolved 24 September 2019
Resolution: Cleared by ABS Report NN3730522
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2019 Resolved
Vessel self-reported an issue with bridge control of main propulsion. Bridge control would switch to local control without human intervention. Show proper operation of bridge control of main propulsion to the satisfaction of class. (74 SOLAS (2014) I/11)
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2019
Resolved 24 September 2019
Resolution: Cleared by ABS Report NN3730522
Electrical › Electric Generation Source (service) › Generator
Issued 25 January 2018 Resolved
The #3 SSDG had internal damage and does not work as designed. Therefore the #3 SSDG is inoperable. This vessel is unable to be brought up from a dead ship situation using it's shaft power take off generators. Repair generator to the satisfaction of a class surveyor.
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 4 May 2018
Engineering › Steering Gear System › Power Unit
Issued 12 May 2017 Resolved
Stbd steering unit power failure alarm, located on the bridge panel, failed to operate. Make repairs and demonstrate proper operation to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 8 June 2017
Resolution: Received Class report
Lifesaving › Rescue Boat › Propulsion Engine
Issued 29 July 2016 Resolved
CG/SOLAS approved rescue boat underwent major modification by the installation of new model propulsion engine not originally approved with boat. Provide proof of CG authorization for modification or CG letter of equivalency to satisfaction of CG Marine Inspector
Due 15 December 2016
Resolved 8 June 2017
Fire Fighting › Fire Main › Valves
Issued 1 February 2012 Resolved
Fire main valve and flange connection on tank deck was leaking due to improper reassembly; replaced gasket and tighten. Retested sat.
Condition: Improper Installation
Due 13 March 2012
Resolved 13 March 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Crosshead Assembly
Issued 3 January 2011 Resolved
Vessel shall prove proper operation of port and starboard engines to the satisfaction of attending classification society surveyor. Vsl shall provide report from attending technician for corrective repair to U.S. Coast Guard. Vsl shall not operate until it has complied with these requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2011
Resolution: Received ABS report proving the proper operation of both engines
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 March 2007 Resolved
Provide proof of proper operation of oily water separator.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2007
Resolved 2 April 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 25 November 2003 Resolved
Repair halon system in engine room so it will shutdown all SSDG's in all modes.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 February 2005
Resolved 17 March 2005
Navigation › Electronic Positioning
Issued 17 October 2003 Resolved
Prove proper operation of the 3cm radar prior to departure from Augusta Bay, Italy.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2003
Resolved 18 October 2003
Resolution: Repaired and witnessed by Captian of Vessel Richard Gray
Deck/Cargo
Issued 13 August 2003 Resolved
Provide written documentation of a satisfactory hydro of cargo piping upon completion of sea trials.
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 13 August 2003
Fire Fighting
Issued 13 August 2003 Resolved
Upon completion of sea trials, prove in the presense of a USCG inspector, a satisfactory test of the vsls sprinkler system.
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 19 August 2003
Communications › Internal Communications System
Issued 13 August 2003 Resolved
Prove proper operation of all sound powered phones. LEGACY COMPONENT DESC: Sound-powered Telephone
Action required: 705 - Other - as specified
Due 19 August 2003
Resolved 19 August 2003
Construction/Loadline › Structures
Issued 13 August 2003 Resolved
Repair as new, broken step on port side accomodation ladder.
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 19 August 2003
Lifesaving › Embarkation Appliances/Stations
Issued 13 August 2003 Resolved
Replace broken steps on starboard side bow embarkation ladder.
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 19 August 2003
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System
Issued 13 August 2003 Resolved
Prove proper operation of starboard side hose reel.
Action required: 705 - Other - as specified
Due 23 August 2003
Resolved 19 August 2003
Deck/Cargo
Issued 13 August 2003 Resolved
Prove proper operation of cargo shutdown alarm on deck.
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 19 August 2003
Deck/Cargo
Issued 13 August 2003 Resolved
Demonstrate proper ease of movement of all cargo shutdown buttons.
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 19 August 2003
Lifesaving › Lifeboat
Issued 13 August 2003 Resolved
Replace gaskets on access doors to lifeboats #2 and # 4.
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 19 August 2003
Communications › Alarms/Indicators
Issued 13 August 2003 Resolved
Prove proper operation of all general alarm bells.
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 19 August 2003
Communications › Alarms/Indicators
Issued 13 August 2003 Resolved
Prove proper operation of all general alarm bells.
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 19 August 2003
Fire Fighting › Structural - A Class Divisions
Issued 13 August 2003 Resolved
Make ECC bulkheads meet structural fire protection during next yard period.
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 25 November 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 13 August 2003 Resolved
Provide CG approved plans and letters for the main space halon system.
Due 21 September 2003
Resolved 18 September 2003
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 13 August 2003 Resolved
Repair main space halon system so the system will shut down all diesel engines within the space, in all modes, as required by NVIC 6-72. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 27 February 2004
Engineering › Compressed Air System (control) › Valve
Issued 13 August 2003 Resolved
Prove proper operation of the pressure relief valve on the newly installed deck compressor
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 August 2003 Resolved
Conduct test of mechanical overspeed trips on both MDE's
Due 21 August 2003
Resolved 19 August 2003
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 13 August 2003 Resolved
Repair or replace shield over #1 pump.
Due 30 April 2004
Resolved 19 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 August 2003 Resolved
Replace cracked fuel expansion joints on both MDE's.
Due 21 August 2003
Resolved 19 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 August 2003 Resolved
Remove oil soaked lagging and replace in kind.
Due 21 August 2003
Resolved 19 August 2003
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 13 August 2003 Resolved
Hrdo or remaove all outdate acetelene bottles in the enginroom.
Due 21 August 2003
Resolved 19 August 2003
Pollution Prevention/Response › Prevention Equipment
Issued 13 August 2003 Resolved
Replace calcium hypoclorite locker LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Due 31 October 2003
Resolved 4 November 2003
Communications › Alarms/Indicators › General Alarm
Issued 13 August 2003 Resolved
Prove proper operation of all eng room general alarm lights.
Due 21 August 2003
Resolved 19 August 2003
Stability › Watertight Integrity › General
Issued 26 April 2002 Resolved
DEMOSTRATE PRE-MOVEMENT WARNING HOWLER FOR ALL SLIDING WATERTIGH DOORS.
Condition: Improper Installation
Due 26 May 2002
Resolved 27 February 2004
Electrical › Lighting (service)
Issued 26 April 2002 Resolved
REPAIR ALL INOP LIGHTS IN FWD PAINT LOCKER LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 26 May 2002
Resolved 15 May 2002
Electrical › Lighting (emergency)
Issued 26 April 2002 Resolved
REPAIR INOP EMERGENCY LIGHT IN ACCESS TRUNK 4-38-1, UPPER LEVEL
Condition: Improper/Lack of Maintenance
Due 26 May 2002
Resolved 15 May 2002
Electrical › Lighting (emergency)
Issued 26 April 2002 Resolved
REPAIR EMERGENCY LIGHT (BATTERN LANTERN AT JUNCTION BOX 1-40-1 NEAR ACCESS TRUNK 4-38-1 LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Due 26 May 2002
Resolved 15 May 2002
Electrical › Lighting (service)
Issued 26 April 2002 Resolved
RENEW GLOBE FOR OVERHEAD LIGHT IN EL-EQPT ROOM 1-40-1 LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 26 May 2002
Resolved 15 May 2002
Electrical › Mast
Issued 26 April 2002 Resolved
REPAIR HIGH VOLTAGE WIRING TO PORT SIDE AFT HIGH VOLTAGE ANTENNA IWO EDG ROOM
Due 26 May 2002
Resolved 15 May 2002
Engineering
Issued 26 April 2002 Resolved
PROVE OPERATION OF SAFETIES ON INCINERATOR PRIOR TO OPERATING THE INCINERATOR LEGACY COMPONENT DESC: INCINERATOR
Due 26 May 2002
Resolved 15 May 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 April 2002 Resolved
PROVE AUTOMATION SAFETIES ON STARBOARD MAIN DIESEL AND ASSOCIATED PTO GENERATOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2002
Resolved 28 April 2002
Accommodation/Occupational Safety
Issued 26 April 2002 Resolved
REMOVE LEAKING ACETYLENE CYLINDER FROM ENGINE ROOM LEGACY COMPONENT DESC: COMPRESSED GAS CYLINDER
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2002
Resolved 15 May 2002
Accommodation/Occupational Safety
Issued 26 April 2002 Resolved
REMOVE DOOR LOCK FROM EMERGENCY ESCAPE DOOR IN ENGINE PORT SIDE. LEGACY COMPONENT DESC: ESCAPE ROUTE
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2002
Resolved 15 May 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 26 April 2002 Resolved
INSTALL BOILER ID PLATES FOR BOTH AUX BOILER. PLATE TO CONTAIN ORIGINAL MANUFACTURE DATA LEGACY COMPONENT DESC: LABEL PLATE
Due 26 May 2002
Resolved 19 May 2002
Fire Fighting › Structural - A Class Divisions
Issued 26 April 2002 Resolved
REPAIR FIRE STOP ON DECK UNDER FIRE CONTROL PANEL
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2002
Resolved 28 April 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 April 2002 Resolved
CONDUCT A MECHANICAL OVERSPEED TRIP ON BOTH MDE AFTER ENGINE BREAK IN PERIOD. LEGACY COMPONENT DESC: CONTROLS
Action required: 705 - Other - as specified
Due 26 May 2002
Resolved 15 May 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 April 2002 Resolved
PROVIDE WRITTEN DOCUMENTATION FROM [name withheld] PTO GEN SETS OPERATE IN A FULL LOAD OVER FULL RANGE OF THROTTLE LEVER POSITION IAW PAGE 2-7 OF THE APPROVED AUTOMATION PROCEDURES.
Due 26 May 2002
Resolved 15 May 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 April 2002 Resolved
PROVIDE WRITTEN DOCUMENTATION FROM [name withheld] PTO GEN SETS PROPERLY OPERATE WITH LEVER AHEAD AND ASTERN TO SHOW ENGINE SPEED CHANGE DO NOT AFFECT THE GEN SETS.
Due 26 May 2002
Resolved 15 May 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 April 2002 Resolved
PROVIDE DOCUMENTATION THAT FUEL LINE DRAIN HOSES QUICK-DISCONNECT FITTINGS ARE CG APPROVED OR RENEW WITH FLANGED OR THREADED FITTINGS.
Condition: Improper Installation
Due 26 May 2002
Resolved 15 May 2002
Deck/Cargo › Cargo Transfer (solid)
Issued 1 April 2002 Resolved
Prior to conducting repairs to the #3 king post, provide written repair proposal to the Coast Guard. Include weld procedure and welders qualifications as well as material specifications.
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 11 April 2002
Resolution: Approved weld procedure and welder qualifications provided and accepted.
Deck/Cargo › Cargo Transfer (solid)
Issued 1 April 2002 Resolved
Provide written report as to the determined cause of the fracture in the weld for the #3 king post aft, inboard corner.
Action required: 705 - Other - as specified
Due 24 April 2002
Resolved 1 April 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 1 April 2002 Resolved
PROVIDE APPROVAL LETTER FOR VESSEL RESPONSE PLAN
Condition: Unknown
Due 26 May 2002
Resolved 28 May 2002
Documentation › Logs/Records
Issued 1 April 2002 Resolved
PROVIDE LIFESAVING EQUIPMENT MAINTENANCE RECORDS IAW 46 CFR 199.190 LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Condition: Unknown
Due 26 May 2002
Resolved 15 May 2002
Fire Fighting › Ventilation Systems
Issued 1 April 2002 Resolved
LABEL POSITION INDICATORS (OPEN/CLOSE) FOR ALL FIRE DAMPERS IN INCINERATOR ROOM LEGACY COMPONENT DESC: Ducts
Condition: Improper Installation
Due 26 May 2002
Resolved 15 May 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 April 2002 Resolved
PROPERLY INSTALL COVER PLATE FOR HALON PRESSURE CUT OFF SWITCH FOR INCENERATOR. LEGACY COMPONENT DESC: Control Valve
Due 26 May 2002
Resolved 15 May 2002
Lifesaving › Embarkation Appliances/Stations
Issued 1 April 2002 Resolved
INSTALL THE PROPER LENGTH EMBARKATION LADDERS AT ALL EMBAKATION STATIONS. CURRENT LADDERS ARE TO SHORT LEGACY COMPONENT DESC: Steps
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 15 May 2002
Communications › Internal Communications System
Issued 1 April 2002 Resolved
DEMONSTRATE PROPER OPERATION OF 1JV CIRCUIT LOCATED ON THE BOW LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper/Lack of Maintenance
Due 26 May 2002
Resolved 15 May 2002
Communications › Alarms/Indicators
Issued 1 April 2002 Resolved
DEMONSTRATE PROPER OPERATION OF GENERAL ALARM BELL ON BRIDGE LEGACY COMPONENT DESC: General Alarm
Condition: Placed in Improper Service
Due 26 May 2002
Resolved 15 May 2002
Lifesaving › Embarkation Appliances/Stations
Issued 1 April 2002 Resolved
DEMONSTRATE PROPER OPERATION OF ALL EMBARKATION LIGHTS
Condition: Improper/Lack of Maintenance
Due 26 May 2002
Resolved 15 May 2002
Communications › Alarms/Indicators
Issued 1 April 2002 Resolved
LABEL CARGO EMERGENCY SHUT DOWN HORN LOCATED ON DECK HOUSE FOR 01 DECK
Due 26 May 2002
Resolved 15 May 2002
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System
Issued 1 April 2002 Resolved
REMOVE SECTION OF FLEXIBLE FIRE HOSE AND RENEW PIPING AS ORIGINAL FOR FWD AFFF PUMP SYSTEM OR PROVIDE COAST GUARD APPROVED DRAWINGS SHOWING FLEXIBLE HOSE INSTALLATION. LEGACY COMPONENT DESC: Foam Generator
Condition: Improper Installation
Due 26 May 2002
Resolved 15 May 2002
Fire Fighting › Ventilation Systems
Issued 1 April 2002 Resolved
REMOVE RUST ON KNIFE EDGES OF ALL GOOSE NECK INTAKE/EXHAUST VENTS LOCATED ON THE BOW AREA LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper/Lack of Maintenance
Due 26 May 2002
Resolved 15 May 2002
Lifesaving › Launching Appliances
Issued 10 January 2002 Resolved
CONDUCT REPAIRS TO THE NO.2 LIFEBOAT DAVIT BRAKE SYSTEM & SUBMIT COPY OF MANUFACTURER REP REPORT STATING REASON FOR COMPONENT FAILURE. LEGACY COMPONENT DESC: Winch Brake
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 22 January 2002
Resolution: REPAIRS COMPLETED AND CONDUCTED WEIGHT TEST OF DAVIT SYSTEM TO 110%.
Lifesaving › Lifeboat
Issued 10 January 2002 Resolved
CONDUCT INSPECTION SURVEY ON NO.2 LIFEBOAT FOR ANY POSSIBLE DAMAGE. TO BE CONDUCTED BY MANUFACTURER REP. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 22 January 2002
Resolution: SURVEY CONDUCTED. LIFEBOAT REMAINS IN SERVICE.
Lifesaving › Launching Appliances
Issued 10 January 2002 Resolved
REPLACE RELEASING CABLE AND ASSOCIATED SHEAVES & BRACKETS TO NO.2 LIFEBOAT RELEASING EQUIPMENT. LEGACY COMPONENT DESC: Davit
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 22 January 2002
Resolution: ITEMS REPLACED AND IN GOOD WORKING ORDER.
Documentation › Certificates/Documents
Issued 10 January 2002 Resolved
SUBMIT CG-2692 REPORT WITH WITNESS STATEMENTS OF ACCIDENT TO NO.2 LIFEBOAT DAVIT SYSTEM AND LIFEBOAT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2002
Resolved 15 January 2002
Resolution: RECEIVED FAX COPIES OF CG-2692 AND WITNESS STATEMENTS. IN FILE AT MAIN OFFICE.
Lifesaving › Lifeboat
Issued 10 January 2002 Resolved
CONDUCT 110% WEIGHT TEST TO NO.2 LIFEBOAT DAVIT IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 22 January 2002
Resolution: COMPLETED TEST-SAT.
Lifesaving › Launching Appliances
Issued 10 January 2002 Resolved
CONDUCT INSPECTION SURVEY ON NO.2 LIFEBOAT DAVIT SYSTEM BY MANUFACTURERE REPRESENTATIVE AND SUBMIT REPORT TO COAST GUARD MARINE INSPECTOR. LEGACY COMPONENT DESC: Davit
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 22 January 2002
Resolution: SURVEY CONDUCTED. WEIGHT TEST SAT.
Deck/Cargo
Issued 27 April 2001 Resolved
Test operation of each cargo system PRV IAW 33 CFR 156.170(c)(2).
Condition: Unknown
Due 12 June 2001
Resolved 9 May 2001
Deck/Cargo
Issued 27 April 2001 Resolved
Test operation of each cargo system pressure gauge IAW 33 CFR 170(C)(3).
Condition: Unknown
Due 12 June 2001
Resolved 9 May 2001
Lifesaving
Issued 27 April 2001 Resolved
Mark all 13 Hamer hydrostatic releases for life rafts to reflect Apr03 expiration date.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Operations/Management › FireFighting
Issued 27 April 2001 Resolved
Renew fire control plan reflecting current arrangement of FF equipement. EXTENSION GRANTED. LEGACY COMPONENT DESC: Fire Control Plan
Due 30 April 2002
Resolved 19 February 2002
Deck/Cargo
Issued 27 April 2001 Resolved
Prove operational test of all cargo pump remote shutdowns.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Engineering
Issued 27 April 2001 Resolved
Repair F/O leaks on port MDE B1 & B4 fuel accumulators/snubbers.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Deck/Cargo
Issued 27 April 2001 Resolved
Hydro test cargo piping IAW 33 CFR 156.170(c)(4).
Condition: Unknown
Due 12 June 2001
Resolved 9 May 2001
Fire Fighting
Issued 27 April 2001 Resolved
Conduct operational test of all 3 main deck sprinkler zones.
Condition: Unknown
Due 31 August 2001
Resolved 6 September 2001
Lifesaving
Issued 27 April 2001 Resolved
Renew bridge mounted SART with cracked body.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Electrical
Issued 23 February 2001 Resolved
PRIOR TO DEPARTURE EFFECT REPAIRS TO THE NO.1 PTO SYNCHRONOUS COMPENSATOR RUN-UP MOTOR DRIVE END BEARING AND SHAFT.
Condition: Unknown
Due 28 February 2001
Resolved 24 February 2001
Electrical
Issued 23 February 2001 Resolved
PRIOR TO DEPARTURE CONDUCT OPERATIONAL TEST OF THE NO.1 PTO SYNCHRONOUS COMPENSATOR RUN-UP MOTOR TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 28 February 2001
Resolved 24 February 2001
Electrical
Issued 2 January 2001 Resolved
MAKE PERMANENT REPAIRS TO SSDG NO.4 AND CONDUCT FULL FUNCTION TEST OF ALL SHUT DOWNS AND OPERATIONAL TEST UNDER A ELECTRICAL LOAD IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. MSO HAMPTON ROADS MUST BE NOTIFIED IMMEDIATELY UPON FAILURE OF ONE OF THE THREE REMAINING GENERATORS.
Condition: Unknown
Due 2 January 2001
Resolved 2 January 2001
Electrical
Issued 2 January 2001 Resolved
PROVE PROPER AUTO STARTUP OF NO.3 SSDG WITH THE LOSS OF POWER OF NO.2 PTO GENERATOR I.A.W APPROVED AUTOMATION PROCEDURES. ENGINE ROOM MUST BE FULLY MANNED AT ALL TIMES WHILE UNDERWAY UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 15 April 2001
Resolved 24 February 2001
Engineering
Issued 2 January 2001 Resolved
PROVE PROPER OPERATION OF THE CPP PITCH CONTROL FROM PILOT HOUSE AND ENGINECONTROL ROOM FOR THE STARBOARD SHAFT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 8 January 2001
Resolved 9 February 2001
Engineering
Issued 16 November 1999 Resolved
PROVIDE ABS REPORT OF SATISFACTORY REPAIRS AND TESTING FOR #1 BOILER COIL LEAK.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Documentation
Issued 11 February 1999 Resolved
Provide evidence of a valid Load Line Certificate prior to next oceans/coastwise voyage.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 9 March 1998 Resolved
PROVE PROPER OPERATION OF SOUND LEVEL FOR HALON AUDIBLE ALARMFOR EMERGENCY GENERATOR.
Condition: Unknown
Due 9 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 9 March 1998 Resolved
PROVE PROPER OPERATION OF SUPPLY FAN PRESSURE SWITCH FOR AFT FLAMMABLE STORES HALON SYSTEM.
Condition: Unknown
Due 9 March 1998
Resolved 10 March 1998
Documentation
Issued 22 January 1998 Resolved
MAKE VESSEL AVAILABLE FOR REINSPECTION, CARGO TANK INTERNALS AND INTERNAL STRUCTURE EXAMINATION PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Fire Fighting
Issued 21 February 1997 Resolved
MAKE PERMANENT REPAIRS IN WAY OF HELO DECK AFFF FIRE PUMP LEAK IN PIPING.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Documentation
Issued 21 February 1997 Resolved
PROVIDE CURRENT EDITION ONBOARD VESSEL OF CFR PARTS 33, 46 AND 49.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Lifesaving
Issued 21 February 1997 Resolved
PROVE PROPER OPERATION OF NO. 2 LIFEBOAT MOTOR ELECTRIC STARTER.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Accommodation/Occupational Safety
Issued 21 February 1997 Resolved
REMOVE ALL POP RIVETS FROM FIRE DAMPERS IN ALL INTERNAL SPACES WHERE FITTED. (PUMP ROOMS, PUMP MOTOR ROOM, FIRE PUMP ROOMS, HALOM ROOM, AFT STEERING GEAR FLAT, PAINT LOCKERS).
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Lifesaving
Issued 22 November 1996 Resolved
PROVE PROPER OPERATION OF #2 LIFEBOAT MOTOR ELECTRIC STARTER.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Unknown
Issued 22 November 1996 Resolved
REMOVE ALL POP RIVETS FROM FIRE DAMPERS IN ALL INTERNAL SPACES WHERE FITTED. (PUMP ROOMS, PUMP MOTOR ROOM, FIRE PUMP ROOMS, HALON ROOM, AFT STEERING GEAR FLAT, PAINT LOCKERS)
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Unknown
Issued 22 November 1996 Resolved
PROVIDE CURRENT EDITION, ON BOARD VESSEL, OF CODE OF FEDERAL REGULATIONS PARTS 33, 46 AND 49.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Fire Fighting
Issued 22 November 1996 Resolved
MAKE PERMANENT REPAIRS I.W.O. HELO DECK AFFF PUMP LEAK IN PIPING.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Lifesaving
Issued 18 September 1995 Resolved
THE CONNECTION OF THE EPIRB "AUTOMATIC ON" SWITCH WITH THE SHIP ONCE THE HYDRO RELEASE DISENGAUGES IS MISSING.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Construction/Loadline
Issued 18 September 1995 Resolved
VALVE STEM HAD BROKE, FOUND WHEN VALVE OPENED. VALVE NOT SEATED PROPERLY, BRAKE CAUSED BY VIBRATION.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Construction/Loadline
Issued 18 September 1995 Resolved
VALVE STEM GUIDE IN BALLAST OVERBOARD VALVE CRACKED ON ONE SUPPORT.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Construction/Loadline
Issued 18 September 1995 Resolved
CRACKING AT FLANG OF SEA CHEST STAINER HOUSING CAUSED BY VIBRATION.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Accommodation/Occupational Safety
Issued 21 March 1993 Resolved
MOUNT/INSTALL POLLUTION PLACARDS IN REQUIRED LOCATIONS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Lifesaving
Issued 21 March 1993 Resolved
MAKE REPAIRS TO #1 LIFEBOAT DAVIT AND CONDUCT A SATISFACTORY LOAD TEST
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Lifesaving
Issued 21 March 1993 Resolved
MAKE APPROPRIATE REPAIRS TO THE STBD RESCUE BOAT AND TEST_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Documentation
Issued 21 March 1993 Resolved
PROVIDE, MAKE AVAILABLE A HAZARDOUS LOCATION PLAN AS PER 46CFR 110.25-1(1)
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Engineering
Issued 21 March 1993 Resolved
MODIFIFY AUTOMATION PROCEDURES, REMOVING REDUNDANCIES AND TESTING EQUIP. ONLY PERTAINING TO UNATTENDED OPERATIONS AND SAFETY RELATED ITEMS. TEST PROCEDURES SHOULD BE IN A SEQUENCE THAT PREVENTS UNNECESSARY SHIFTING OF LOADS. ITEMS NEED TO INDICATED THAT CAN'T BE CONDUCTED AT A DOCKSIDE TRIAL
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Engineering
Issued 21 March 1993 Resolved
REPAIR #2 PTO CIRCUIT TO PROPER OPERATION IN ALL MODES AS PER TEST PROCEDURES
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Fire Fighting
Issued 21 March 1993 Resolved
REPAIR EMERGENCY FIREPUMP HIGH SUCTION VALVE
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Electrical
Issued 21 March 1993 Resolved
REPLACE THE DEFECTIVE I/O CABLE FOR #6 I/O STATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Unknown
Issued 21 March 1993 Resolved
DEMONSTRATE PROPER OPERATION OF SCBA SYSTEM_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Fire Fighting
Issued 21 March 1993 Resolved
INSTALL PRESSURE RELIEF VALVE AFTER FIREPUMP AND BEFORE THE DISCHARGE VALVEAS PER 46CFR 34.10-5(d)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 21 June 1993
Lifesaving
Issued 10 September 1992 Resolved
CONDUCT SATISFACTORY WEIGHT TEST OF ALL LIFEBOATS AND RESCUE BOAT DAVITS UPON COMPLETION OF END FOR ENDING OF FALLS BUT NO LATER THAN 31JAN93.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Lifesaving
Issued 10 September 1992 Resolved
REPAIR OR REPLACE FORWARD PORT 4 FOOT SECTION OF RUB RAIL TO LIFEBOAT #3 NOT LATER THAN 17OCT92.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Engineering
Issued 10 September 1992 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR AND THE MONITORING AND CONTROL SYSTEM.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Construction/Loadline
Issued 10 September 1992 Resolved
REPLACE THE DAMAGED CONTROLLER DOOR FOR THE STBD. SLIDING WATERTIGHT DOOR IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Documentation
Issued 3 February 1992 Resolved
PROVIDE 3 COPIES OF AS BUILT PLANS, TO [name withheld], VA. FOR APPROVAL. PLANS TO INCLUDE ELECTRICAL, STUCTURAL, AND PIPING.
Condition: Unknown
Due 30 April 1992
Resolved 18 May 1992
Documentation
Issued 3 February 1992 Resolved
AMEND CARGO TRANSFER PROCEDURES TO INCLUDE CARGO TRANSFER OPERATIONS OF CARGO TO AND FROM MARINE PORTABLE TANK.
Condition: Unknown
Due 3 March 1992
Resolved 16 March 1992
Documentation
Issued 3 February 1992 Resolved
PROVIDE MANUFACTURER'S DATA REPORT FOR INSTALLED MARINE PORTABLE TANK, TO [name withheld] AND ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1992
Resolved 16 March 1992
Deck/Cargo
Issued 28 January 1992 Resolved
CONDUCT HYDROSTATIC TEST OF ALL CARGO TRANSFER PIPING AT 1 1/2 TIMES THE SETTING OF THE CARGO TRANSFER PUMPS RELIEVING VALVES.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Engineering
Issued 20 December 1991 Resolved
REMOVE FROM SERVIC THE AIR FLASK ON # FAS STA 8, PORT OUTBOARD FWD BOTTLE, AVONDALE S/Y # C5-200-2355-1. UNTIL STRUCTURAL INTEGRATY OF PRESSURE VESSELIS DETERMINE BY HYDROSTATIC TEST AT 1.5 MAWP AND NDT(ULTRASONIC SHEARWAVE OR ACCOUSTICAL EMMISION)._x001C_
Condition: Unknown
Due 28 February 1992
Resolved 28 January 1992
Engineering
Issued 20 December 1991 Resolved
PROVIDE MANUFACTURES DATA REPORTS ON EACH AIR RECEIVER WHICH APPEARS ON THEVESSEL'S CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Deck/Cargo
Issued 9 December 1991 Resolved
CONDUCT HYDROSTATIC TEST AT 1 1/2 TIMES THE SETTING OF THE TRANSFER PUMPS RELIEVING VALVES.
Condition: Unknown
Due 9 December 1991
Resolved 9 December 1991
Deck/Cargo
Issued 9 December 1991 Resolved
CONDUCT HYDROSTATIC TEST AT 225 PSI, ON ALL OVERDUE OIL TRANSFER HOSES.
Condition: Unknown
Due 9 December 1991
Resolved 9 December 1991
Engineering
Issued 25 July 1991 Resolved
PROVE PROPER OPERATION OF ALL AIR RECEIVERS RELIEF VALVES BY LIFTING UNDER PRESSURE. THIS TO BE ACCOMPLISHED PRIOR TO LEAVING NEXT U.S. PORT WITH SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1991
Resolved 25 July 1991
Fire Fighting
Issued 25 July 1991 Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWNS LOCATED IN FIRE CONTROL PANELACROSS SHIPS PASSAGEWAY. THIS IS TO BE ACCOMPLISHED PRIOR TO LEAVING NEXT U.S. PORT WITH THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1991
Resolved 25 July 1991
Engineering
Issued 25 July 1991 Resolved
MAKE AVAILABLE FOR INTERNAL EXAM OR HYDRO TEST BIENNIAL CREDIT ALL PRESSUREVESSELS. AS LISTED ON COI. TO BE ACCOMPLISHED PRIOR TO LEAVING NEXT U.S._x001C_ PORT WITH SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1991
Resolved 25 July 1991
Accommodation/Occupational Safety
Issued 25 July 1991 Resolved
OXYGEN BOTTLE LOCATED IN HOSPITAL PASSED DUE HYDRODATE. MAKE O2 BOTTLE AVAILABLE FOR HYDROSTATIC TEST AT AN APPROVED DOT SERVICING FACILITY.
Condition: Unknown
Due 20 November 1991
Resolved 20 November 1991
Engineering
Issued 15 November 1990 Resolved
PROVE SATISFACTORY OPERATION OF THE AUXILIARY BOILER SAFETY RELIEF VALVES.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Engineering
Issued 15 November 1990 Resolved
PROVIDE SUITABLE GAGS FOR EACH AUXILIARY BOILER SAFETY RELIEF VALVE.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Engineering
Issued 30 June 1990 Resolved
MAIN ENGINE AUTOMATION TO BE DEMONSTRATED ACTUAL COMPLIANCE DATE: 30JUL90
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Fire Fighting
Issued 30 June 1990 Resolved
FIRE AND BILGE PUMP TO BE DEMONSTRATED FROM ALL LOCATIONS, LOCAL BRIDGE, CONTROL BOOTH ENGINE ROOM. TAGS TO BE PLACED ON BRIDGE CONTROL AND ENGINE-ROOM CONTROL. USE ONLY FROM LOCAL STATION IN AN EMERGENCY
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Accommodation/Occupational Safety
Issued 2 August 1989 Resolved
ELIMINATE VENTILATION DUCT IN CLASS 'A' BULKHEAD BETWEEN PORT SIDE OF GALLEY (MAIN DECK) AND PORT SIDE FORE & AFT PASSAGEWAY SO AS TO COMPLY WITH CFR 32.57-10(D)(1)
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Accommodation/Occupational Safety
Issued 2 August 1989 Resolved
ELIMINATE VENTILATION DUCT IN CLASS 'A' BULKHEAD BETWEEN STARBOARD SIDE OF GALLEY (MAIN DECK) AND STARBOARD SIDE FORE & AFT PASSAGEWAY SO AS TO COMPLY WITH 46 CFR 32.57-10 (D)(1)
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Accommodation/Occupational Safety
Issued 2 August 1989 Resolved
ELIMINATED VENTILATION DUCT IN CLASS A' BULKHEAD BETWEEN (06) LEVEL, ATHWARTSHIPS PASSAGEWAY AND DECK OF WHEELHOUSE SO AS TO COMPLY WITH 46 CFR 32.57-10(D)(1).
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Accommodation/Occupational Safety
Issued 2 August 1989 Resolved
ELIMINATE VENTILATION DUCT IN CLASS 'A' BULKHEAD BETWEEN THE IC GYRO ROOM (06) LEVEL AND ADJACENT PASSAGEWAY SO AS TO COMPLY WITH 46 CFR 32.57-10(D)(1)
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Fire Fighting
Issued 2 August 1989 Resolved
COMPLETE INSTALATION AND SATISFACTORILY DEMONSTRATE THE INCINERATOR ROOM'S FIXED, HALON FIRE EXTINGUISHING SYSTEM. VESSEL IS NOT AUTHORIZED TO OPERATEINCINERATOR UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Fire Fighting
Issued 2 August 1989 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF THE AFTER STEERING SPACES'S HALON, CUT-OUT SWICH FOR THE EXHAUST BLOWER UNDERGOING INSTALLATION
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Deck/Cargo
Issued 2 August 1989 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF ALL AIR RECEIVER RELIEF VALVES FOR THE RAS/FAS UNREP EQUIPMENT. RAS/FAS EQUIPMENT SHALL NOT BE OPERATED UNTIL COMPLETED.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Accommodation/Occupational Safety
Issued 2 August 1989 Resolved
ELIMINATE VENTILATION DUCT IN CLASS 'A' BULKHEAD BETWEEN CARGO CONTROL CENTER (06) LEVEL AND PASSAGEWAY SO AS TO COMPLY WITH 46 CFR 32.57-10(D)(1)
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.