USNS KANAWHA

USNS KANAWHA is a 1991 tank ship. The Coast Guard has recorded 43 inspections since 2016, most recently in June 2026, along with 34 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 3 June 2026.

Built
1991
Last inspected
3 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8704080
313343
Flag
UNITED STATES
Maury page id
psix-313343

Documentation record

Tonnage as PSIX records it8992 - Convention (Subpart B), Net Ton
18987 - Regulatory (Subpart C or D), Net Ton
27671 - Dead Weight, Ton
42383 - Displacement, Ton
25742 - Convention (Subpart B), Gross Ton
20706 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 43

3 June 2026 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8390048
14 May 2026 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8372917
28 January 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8302910
23 October 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8257668
24 September 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8240565
30 August 2025 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8222475
25 August 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8217916
14 August 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8209735
4 August 2025 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8202768
31 July 2025 Deficiency Check · Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8199070
22 July 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8194370
28 February 2025 Re-Inspection · ACP COI Oversight · ACP Drydock Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8086264
3 September 2024 Administrative Inspection · ACP Annual Oversight · ACP Drydock Oversight · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7997263
26 June 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7945327
16 May 2023 Administrative Inspection · ACP Drydock Oversight · ACP Periodic Oversight · ACP Additional Oversight – Risk Assessment · Periodic Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7709740
21 April 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7996966
25 December 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7613182
1 November 2022 Type not recorded
No type recorded · Activities Europe · Activity 7630839
1 September 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7548496
22 July 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7513793
20 July 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7560362
15 July 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7512509
28 June 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7489018
13 March 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7411190
8 September 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7306775
13 August 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7285743
24 May 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7205735
5 February 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7136509
19 January 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7126902
25 November 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7102148
28 April 2020 Administrative Inspection · ACP COI Oversight · Examination of Repairs · Re-Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6945235
2 November 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6848011
30 October 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6845888
10 July 2019 ACP Annual Oversight · Annual Inspection · Special · Administrative Inspection · ACP Drydock Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6745642
7 March 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6641114
4 August 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6467178
19 April 2018 Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 6394503
21 March 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6375875
22 December 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6327788
17 November 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6308555
7 February 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6083907
12 September 2016 DAPI Audit · ACP Annual Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5996371
12 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5852166

Deficiency record · 34

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of present regulations to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Vessel self-reported casualty of port steering pump while in port doing pre-departure checks. 74 SOLAS (24) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2025 Resolved
Vessel is authorized to shift locally with in the port to Craney Island with tug escort of; one tug escort greater than or equal to 3,000 aggregate total horsepower; or one tug escort greater than or equal to 40 ton bollard pull; or a two tug escort greater than or equal to 4,000 aggregate total horsepower (each tug must have a minimum of 2,000 horsepower); or a two tug escort greater than or equal to 40 ton aggregate bollard pull. If the vessel experiences any propulsion or steering issues while underway you are to follow Coast Guard marine casualty reporting requirements to the Captain of the Port. 33CFR 160.111
Action required: 705 - Other - as specified
Resolved 26 September 2025
Resolution: Pump replaced. Tug escort no longer required
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 August 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. A leak was observed on the foam line piping at Frame 1-43-2 74 SOLAS (20) II-1/14.2.1.2, 701a
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2025
Resolution: Received ABS report accepting deficiency and attached it to this activity.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 August 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. A quarter-inch fracture was observed on the foam line adjacent to Foam Monitor Station 2 (Frame 02-37-2) 74 SOLAS (20) II-1/14.2.1.2, 701a
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2025
Resolution: Cleared via acceptance by RO
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 August 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard side #3 lifeboat aft davit arm was bent rearward during recovery operations. Prior to lowering and raising the #3 lifeboat davit. 74 SOLAS (2024 Con. Ed.) III/20.2, 705a
Action required: 705 - Other - as specified
Resolved 15 August 2025
Resolution: Received finding number from RO Surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 August 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard side #3 lifeboat aft davit arm was bent rearward during recovery operations. Vessel manning is reduced to carrying a maximum of 69 personnel. Prior to lowering and raising the #3 lifeboat davit, it shall be evaluated by a certified manufacturer's technician & the report shall be received and reviewed by the attending CG Marine Inspector. 74 SOLAS (2024 Con. Ed.) III/20.2, 705c
Action required: 705 - Other - as specified
Resolved 9 September 2025
Resolution: Received objective evidence via class report that the lifeboat davit was repaired and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported their port main engine is down due to an issue with a fuel pump. 74 SOLAS (2024 Con. Ed.) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2025
Resolved 1 August 2025
Resolution: Received class report and attached to this activity.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2025 Resolved
While transiting the Port of Hampton Roads the vessel is required a one tug escort greater than or equal to 3,000 aggregate total horsepower; or one tug escort greater than or equal to 40 ton bollard pull; or a two tug escort greater than or equal to 4,000 aggregate total horsepower (each tug must have a minimum of 2,000 horsepower); or a two tug escort greater than or equal to 40 ton aggregate bollard pull. If the vessel experiences any propulsion or steering issues while underway you are to follow Coast Guard marine casualty reporting requirements to the nearest Captain of the Port. Prior to departing the port, equipment shall be repaired & a class report attesting to the repairs shall be received and reviewed by Sector Virginia. 33 CFR 160.111(c)
Action required: 705 - Other - as specified
Resolved 4 August 2025
Resolution: Received class survey report and objective evidence a sea trial was completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 July 2025 Resolved
The administration shall take appropriate steps to ensure implementation and application of this part in respect of electrical installations. Electrical enclosure for ECR water tight door controller is damaged and does not close properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 22 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 June 2025 Resolved
Cargo ships, such units shall indicate in which section served by the system fire has occurred. Fire detection system has fault in loop 141.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 9 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 June 2025 Resolved
Lifeboats shall be provided with at least 1 drain valve fitted near the lowest point of the hull, shall automatically close to prevent entry of water when the life boat is waterborne. During launching drill the drain vale did not close allowing water to enter the boat and drain out after recovery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 9 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Automatic radar plotting aid (ARPA)
Issued 30 June 2025 Resolved
Each device required under paragraph (b) of this section must have a permanently affixed label containing:(i) The name and address of the manufacturer; and(ii) The following statement:“This device was designed and manufactured to comply with the International Maritime Organization (IMO) ‘Performance Standards for Automatic Radar Plotting Aids (ARPA).’ ARPA was not marked in accordance with requirement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 5 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 June 2025 Resolved
An immersion suit, of an appropriate size, shall be provided for every person. Two crew members could not zip up assigned Viking immersion suits.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 22 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 30 June 2025 Resolved
Life boat will be fitted with approved fire extinguisher. Life boats had wrong extinguisher bracket or wrong extinguisher present as they did not fit the installed brackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 31 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 February 2025 Resolved
Unless expressly provided otherwise, every ship shall be provided with a main steering gear and auxiliary steering gear to the satisfaction of the administration. NON-follow up has 10-20 degree over run during operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 22 July 2025
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 22 August 2023 Resolved
A mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section. Containment did not have mechanical plugs only wood plugs.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2023 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. In way of paint locker was hanging electrical splice. Cargo transfer controllers missing covers/blanks for removed swithches/gauges. E/R Changing room had temporary wiring with powerstrip powering multiple items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 August 2023 Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboats and life raft embarkation deck. Injector rm emergench escape can be locked. egress out of the electrician shop can be locked from out side.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2023 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. FD 1-105-1 didnt close. FD 2-118-0 had holdback and didnt close.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 22 August 2023 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. Wrong DPA information was posted.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 August 2023
Resolution: Correct DPA information was posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported malfunction of the main air start valve on the Port ME. 74 SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 25 July 2022
Resolution: ABS report uploaded in Documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2022 Resolved
Vessel is required (1) assist tug rated of 3000 horse power or (2) assist tugs rated of 2000 horse power to transit from Norfolk Naval Base to Craney Island.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2022
Resolved 25 July 2022
Resolution: Vessel came into port with tug assistance.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 June 2022 Resolved
For a period of 18h, emergency lighting in the machinery spaces and main generating stations including their controls positions. Found emergency lighting in starboard side escape trunk IWO 7-39-1 to be inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: New light bulb was placed in E-lights and lights illuminated. Light is fed from main power and E- switchboard.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 June 2022 Resolved
On a tankship, each cargo tank must be equipped with an overfill device (including an independent audible and visual indicator for that tank) that meets the requirements for tank overfill alarms under 46 CFR 39.2007(d)(1)-(4). Center station overfill visual indicator red light operating intermediately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: New flashing light assembly was installed and tested and found to flash at correct frequency.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 June 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Found 01 missing dog and multiple frozen dogs on Natural Exhaust Motor RM#2 (1-38-1) fire damper; Found multiple frozen dogs IWO 01-64-2 & 01-67-2 fire dampers; Found missing gasket sections on Discharge Exhaust Vent for the Bosn' Storeroom (02-26-0). Found deteriorated gasket on the Intake Supply vent (02-27-02).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: Missing dogs replaced, seized dogs freed and properly working, missing and deteriorated gaskets renewed and in good working order.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 June 2022 Resolved
All lifesaving appliances shall- be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. All 04 lifeboats had deteriorating reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: New SOLAS approved reflective tape installed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 June 2022 Resolved
General Alarm System shall be audible throughout all accommodation spaces, normal crew working spaces and open deck. Found general alarm bell in cargo pump room loose, therefore not hitting the striker, causing no audible sound.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: Adjusted bell to ring when alarm sounded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2022 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers or in compartments assigned principally in paint lockers unless appropriately certified for safe usage in the dusts, vapors or gases likely to be encountered. Found 02 non-extrinsically safe portable fans located in the ships paint locker.
Action required: 10 - Deficiency Rectified
Due 28 June 2022
Resolved 28 June 2022
Resolution: Chief Mate had fans removed from space during inspection. Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Galley roller door tensioner is inoperable. 74SOLAS(20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2022
Resolved 16 June 2022
Resolution: Installed new tension spring in roller door.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 September 2021 Resolved
After any survey of the ship, no change shall be made to machinery covered by the survey without the sanction of the Administration. Vessel unable test emergency shut off’s for cargo pumps. 74 SOLAS (20) I/11(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 September 2020 Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm. 2C high level alarm is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 January 2021
Resolution: Recieved class report See Doc
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 September 2020 Resolved
Deck foam system; Systems of this type are designed to give primary protection to the spaces over the cargo tanks. Multiple nozzles are clogged and inoperative. Check valves between zones are inoperative.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2020
Resolution: Repaired and operating to the satisfaction of ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2020 Resolved
Each helicopter landing deck on which fueling operations are conducted must have a fire protection system that discharges foam. Nozzles are clogged or inoperative on helo pad.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 November 2020
Resolution: Repaired and operating to the satisfaction of ABS surveyor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 September 2020 Resolved
Cargo pipeline testing intervals shall coincide with vessels regular dry dock intervals. Cargo pipelines must undergo two static liquid tests with in a 5 yr period, and not more than three years my elapse. Per MSC/USCG MOA dated 02Jul18 Cargo line was last tested in Feb 18. vessel just underwent a dry dock period.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2020
Resolution: Test performed to the satisfaction of ABS surveyor.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.