USNS KANAWHA is a 1991 tank ship. The Coast Guard has recorded 120 inspections since 1991, most recently in June 2026, along with 137 deficiencies and 1 operational control.

Records from 1991 to 2026. Most recent: inspection, 3 June 2026.

Built
1991
Last inspected
3 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8704080 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
313343
Flag
UNITED STATES
—
Maury page id
psix-313343

Inspections, by type

…with no type recorded23
Years with a record 31 calendar years (1991–2026)
The 120 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8992 - Convention (Subpart B), Net Ton
18987 - Regulatory (Subpart C or D), Net Ton
27671 - Dead Weight, Ton
42383 - Displacement, Ton
25742 - Convention (Subpart B), Gross Ton
20706 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HMCS FREDERICTON Public Vessel, Unclassified · MISLE 882721 · 18 November 2010 · activity 3894999

Inspection history · 120

3 June 2026 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8390048
14 May 2026 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8372917
28 January 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8302910
23 October 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8257668
24 September 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8240565
30 August 2025 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8222475
25 August 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8217916
14 August 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8209735
4 August 2025 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8202768
31 July 2025 Deficiency Check · Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8199070
22 July 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8194370
28 February 2025 Re-Inspection · ACP COI Oversight · ACP Drydock Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8086264
3 September 2024 Administrative Inspection · ACP Annual Oversight · ACP Drydock Oversight · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7997263
26 June 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7945327
16 May 2023 Administrative Inspection · ACP Drydock Oversight · ACP Periodic Oversight · ACP Additional Oversight – Risk Assessment · Periodic Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7709740
21 April 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7996966
25 December 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7613182
1 November 2022 Type not recorded
No type recorded · Activities Europe · Activity 7630839
1 September 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7548496
22 July 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7513793
20 July 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7560362
15 July 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7512509
28 June 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7489018
13 March 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7411190
8 September 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7306775
13 August 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7285743
24 May 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7205735
5 February 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7136509
19 January 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7126902
25 November 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7102148
28 April 2020 Administrative Inspection · ACP COI Oversight · Examination of Repairs · Re-Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6945235
2 November 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6848011
30 October 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6845888
10 July 2019 ACP Annual Oversight · Annual Inspection · Special · Administrative Inspection · ACP Drydock Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6745642
7 March 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6641114
4 August 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6467178
19 April 2018 Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 6394503
21 March 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6375875
22 December 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6327788
17 November 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6308555
7 February 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6083907
12 September 2016 DAPI Audit · ACP Annual Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5996371
12 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5852166
3 October 2014 Administrative Inspection
Administrative · Activities Europe · Activity 5001209
25 August 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4126654
18 August 2011 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4120236
18 November 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3894999
12 September 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3854714
2 September 2008 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3315558
12 March 2007 Administrative Inspection
Administrative · Activities Europe · Activity 2886185
18 October 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2802818
25 July 2006 Administrative Inspection
Administrative · Activities Europe · Activity 2723934
2 June 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2673692
6 April 2006 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2619009
2 April 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2618974
12 August 2005 MTSA Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2410195
1 August 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2460809
6 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2381584
25 May 2005 Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2369836
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104636
1 April 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2074006
19 February 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2009009
30 January 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1997399
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997419
29 October 2003 Administrative Inspection
Administrative · Activities Europe · Activity 1938062
18 November 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1707057
14 November 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1708900
21 October 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1693268
18 October 2002 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1692273
26 September 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1680766
23 August 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1667076
5 June 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1626506
25 February 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1489084
23 October 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 772208
27 September 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1074449
28 August 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 772437
27 August 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 63372
3 July 2001 Excursion Permit
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1068557
7 June 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1072152
29 May 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1070004
23 January 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1057548
7 October 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 117090
1 July 2000 Deficiency Check
Physical examination · Activities Europe · Activity 1051940
7 April 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1047968
18 February 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1046604
18 January 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 813962
10 January 2000 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1453701
4 December 1998 Re-Inspection
Physical examination · Activities Europe · Activity 1364957
10 August 1998 Administrative
Administrative · Activities Europe · Activity 796535
24 February 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1116164
17 December 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1115827
24 November 1997 COI Inspection
Physical examination · Activities Europe · Activity 1372050
20 May 1997 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1442584
21 March 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1102022
31 January 1997 Re-Inspection
Physical examination · Activities Europe · Activity 1359348
16 January 1997 Type not recorded
No type recorded · Activities Europe · Activity 1099574
14 January 1997 Type not recorded
No type recorded · Activities Europe · Activity 8716
4 March 1996 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 884678
12 February 1996 Excursion Permit
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 876988
26 January 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1394456
26 May 1995 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360124
24 February 1995 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 849437
13 January 1995 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 861982
2 November 1994 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 862234
17 October 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1177292
23 September 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1171252
20 September 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1398157
29 June 1994 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 862217
13 June 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1326178
15 April 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1167767
6 April 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 855585
29 March 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1166506
7 March 1994 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1358327
10 September 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 833148
17 May 1993 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 840878
24 July 1992 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 936454
10 April 1992 Excursion Permit
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1262862
9 January 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263263
6 December 1991 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939638
28 January 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249506

Deficiency record · 137

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of present regulations to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Vessel self-reported casualty of port steering pump while in port doing pre-departure checks. 74 SOLAS (24) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2025 Resolved
Vessel is authorized to shift locally with in the port to Craney Island with tug escort of; one tug escort greater than or equal to 3,000 aggregate total horsepower; or one tug escort greater than or equal to 40 ton bollard pull; or a two tug escort greater than or equal to 4,000 aggregate total horsepower (each tug must have a minimum of 2,000 horsepower); or a two tug escort greater than or equal to 40 ton aggregate bollard pull. If the vessel experiences any propulsion or steering issues while underway you are to follow Coast Guard marine casualty reporting requirements to the Captain of the Port. 33CFR 160.111
Action required: 705 - Other - as specified
Resolved 26 September 2025
Resolution: Pump replaced. Tug escort no longer required
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 August 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. A leak was observed on the foam line piping at Frame 1-43-2 74 SOLAS (20) II-1/14.2.1.2, 701a
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2025
Resolution: Received ABS report accepting deficiency and attached it to this activity.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 August 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. A quarter-inch fracture was observed on the foam line adjacent to Foam Monitor Station 2 (Frame 02-37-2) 74 SOLAS (20) II-1/14.2.1.2, 701a
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2025
Resolution: Cleared via acceptance by RO
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 August 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard side #3 lifeboat aft davit arm was bent rearward during recovery operations. Prior to lowering and raising the #3 lifeboat davit. 74 SOLAS (2024 Con. Ed.) III/20.2, 705a
Action required: 705 - Other - as specified
Resolved 15 August 2025
Resolution: Received finding number from RO Surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 August 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard side #3 lifeboat aft davit arm was bent rearward during recovery operations. Vessel manning is reduced to carrying a maximum of 69 personnel. Prior to lowering and raising the #3 lifeboat davit, it shall be evaluated by a certified manufacturer's technician & the report shall be received and reviewed by the attending CG Marine Inspector. 74 SOLAS (2024 Con. Ed.) III/20.2, 705c
Action required: 705 - Other - as specified
Resolved 9 September 2025
Resolution: Received objective evidence via class report that the lifeboat davit was repaired and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported their port main engine is down due to an issue with a fuel pump. 74 SOLAS (2024 Con. Ed.) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2025
Resolved 1 August 2025
Resolution: Received class report and attached to this activity.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2025 Resolved
While transiting the Port of Hampton Roads the vessel is required a one tug escort greater than or equal to 3,000 aggregate total horsepower; or one tug escort greater than or equal to 40 ton bollard pull; or a two tug escort greater than or equal to 4,000 aggregate total horsepower (each tug must have a minimum of 2,000 horsepower); or a two tug escort greater than or equal to 40 ton aggregate bollard pull. If the vessel experiences any propulsion or steering issues while underway you are to follow Coast Guard marine casualty reporting requirements to the nearest Captain of the Port. Prior to departing the port, equipment shall be repaired & a class report attesting to the repairs shall be received and reviewed by Sector Virginia. 33 CFR 160.111(c)
Action required: 705 - Other - as specified
Resolved 4 August 2025
Resolution: Received class survey report and objective evidence a sea trial was completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 July 2025 Resolved
The administration shall take appropriate steps to ensure implementation and application of this part in respect of electrical installations. Electrical enclosure for ECR water tight door controller is damaged and does not close properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 22 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 June 2025 Resolved
Cargo ships, such units shall indicate in which section served by the system fire has occurred. Fire detection system has fault in loop 141.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 9 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 June 2025 Resolved
Lifeboats shall be provided with at least 1 drain valve fitted near the lowest point of the hull, shall automatically close to prevent entry of water when the life boat is waterborne. During launching drill the drain vale did not close allowing water to enter the boat and drain out after recovery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 9 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Automatic radar plotting aid (ARPA)
Issued 30 June 2025 Resolved
Each device required under paragraph (b) of this section must have a permanently affixed label containing:(i) The name and address of the manufacturer; and(ii) The following statement:“This device was designed and manufactured to comply with the International Maritime Organization (IMO) ‘Performance Standards for Automatic Radar Plotting Aids (ARPA).’ ARPA was not marked in accordance with requirement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 5 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 June 2025 Resolved
An immersion suit, of an appropriate size, shall be provided for every person. Two crew members could not zip up assigned Viking immersion suits.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 22 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 30 June 2025 Resolved
Life boat will be fitted with approved fire extinguisher. Life boats had wrong extinguisher bracket or wrong extinguisher present as they did not fit the installed brackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 31 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 February 2025 Resolved
Unless expressly provided otherwise, every ship shall be provided with a main steering gear and auxiliary steering gear to the satisfaction of the administration. NON-follow up has 10-20 degree over run during operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 22 July 2025
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 22 August 2023 Resolved
A mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section. Containment did not have mechanical plugs only wood plugs.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2023 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. In way of paint locker was hanging electrical splice. Cargo transfer controllers missing covers/blanks for removed swithches/gauges. E/R Changing room had temporary wiring with powerstrip powering multiple items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 August 2023 Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboats and life raft embarkation deck. Injector rm emergench escape can be locked. egress out of the electrician shop can be locked from out side.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2023 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. FD 1-105-1 didnt close. FD 2-118-0 had holdback and didnt close.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 22 August 2023 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. Wrong DPA information was posted.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 August 2023
Resolution: Correct DPA information was posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported malfunction of the main air start valve on the Port ME. 74 SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 25 July 2022
Resolution: ABS report uploaded in Documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2022 Resolved
Vessel is required (1) assist tug rated of 3000 horse power or (2) assist tugs rated of 2000 horse power to transit from Norfolk Naval Base to Craney Island.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2022
Resolved 25 July 2022
Resolution: Vessel came into port with tug assistance.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 June 2022 Resolved
For a period of 18h, emergency lighting in the machinery spaces and main generating stations including their controls positions. Found emergency lighting in starboard side escape trunk IWO 7-39-1 to be inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: New light bulb was placed in E-lights and lights illuminated. Light is fed from main power and E- switchboard.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 June 2022 Resolved
On a tankship, each cargo tank must be equipped with an overfill device (including an independent audible and visual indicator for that tank) that meets the requirements for tank overfill alarms under 46 CFR 39.2007(d)(1)-(4). Center station overfill visual indicator red light operating intermediately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: New flashing light assembly was installed and tested and found to flash at correct frequency.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 June 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Found 01 missing dog and multiple frozen dogs on Natural Exhaust Motor RM#2 (1-38-1) fire damper; Found multiple frozen dogs IWO 01-64-2 & 01-67-2 fire dampers; Found missing gasket sections on Discharge Exhaust Vent for the Bosn' Storeroom (02-26-0). Found deteriorated gasket on the Intake Supply vent (02-27-02).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: Missing dogs replaced, seized dogs freed and properly working, missing and deteriorated gaskets renewed and in good working order.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 June 2022 Resolved
All lifesaving appliances shall- be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. All 04 lifeboats had deteriorating reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: New SOLAS approved reflective tape installed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 June 2022 Resolved
General Alarm System shall be audible throughout all accommodation spaces, normal crew working spaces and open deck. Found general alarm bell in cargo pump room loose, therefore not hitting the striker, causing no audible sound.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: Adjusted bell to ring when alarm sounded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2022 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers or in compartments assigned principally in paint lockers unless appropriately certified for safe usage in the dusts, vapors or gases likely to be encountered. Found 02 non-extrinsically safe portable fans located in the ships paint locker.
Action required: 10 - Deficiency Rectified
Due 28 June 2022
Resolved 28 June 2022
Resolution: Chief Mate had fans removed from space during inspection. Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Galley roller door tensioner is inoperable. 74SOLAS(20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2022
Resolved 16 June 2022
Resolution: Installed new tension spring in roller door.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 September 2021 Resolved
After any survey of the ship, no change shall be made to machinery covered by the survey without the sanction of the Administration. Vessel unable test emergency shut off’s for cargo pumps. 74 SOLAS (20) I/11(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 September 2020 Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm. 2C high level alarm is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 January 2021
Resolution: Recieved class report See Doc
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 September 2020 Resolved
Deck foam system; Systems of this type are designed to give primary protection to the spaces over the cargo tanks. Multiple nozzles are clogged and inoperative. Check valves between zones are inoperative.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2020
Resolution: Repaired and operating to the satisfaction of ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2020 Resolved
Each helicopter landing deck on which fueling operations are conducted must have a fire protection system that discharges foam. Nozzles are clogged or inoperative on helo pad.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 November 2020
Resolution: Repaired and operating to the satisfaction of ABS surveyor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 September 2020 Resolved
Cargo pipeline testing intervals shall coincide with vessels regular dry dock intervals. Cargo pipelines must undergo two static liquid tests with in a 5 yr period, and not more than three years my elapse. Per MSC/USCG MOA dated 02Jul18 Cargo line was last tested in Feb 18. vessel just underwent a dry dock period.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2020
Resolution: Test performed to the satisfaction of ABS surveyor.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 18 August 2011 Resolved
Prove proper operation of overfill alarms and emergency cargo pump shutdowns to the satisfaction of the attending Coast Guard Marine Inspector prior to 01 Sept 2011.
Action required: 705 - Other - as specified
Due 1 September 2011
Resolved 24 August 2011
Resolution: Due to operational constraints, requested ABS surveyor to test and witness tests of overfill alarms and emergency cargo pump shutdowns on our behalf- all satisfactory.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 18 August 2011 Resolved
Prove proper operation of cargo control panel to the satisfaction of the attending ABS class surveyor prior to carrying cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2011
Resolution: ABS surveyor verified installation and tested cargo control panel- all satisfactory.
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 March 2007 Resolved
Make repairs to the defective 3 CM radar at next port of call and provide a written statement to cognizant OCMI when repairs are completed.
Condition: Unknown
Due 19 March 2007
Resolved 16 March 2007
Resolution: Received faxed notification of compliance from [name withheld].
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 25 July 2006 Resolved
Make repairs to defective fathometer and provide a written statement to cognizant OCMI when repairs are completed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 10 August 2006
Resolution: Rcvd email from the master with tech report for the repairs and dtg of the cascor msg.
Lifesaving › Lifeboat › Lamp (inside)
Issued 2 June 2006 Resolved
Provide new manufacturer's approved light lens covers to internal lighting on Lifeboats Two and Four.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 18 October 2006
Resolution: Installed approved light lens cover to lifeboats two and four.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 6 April 2006 Resolved
Renew SFP protecting HALON from paint locker and signage.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 14 June 2006
Resolution: New A-60 insulation installed to inside of pait locker for HALON bottle protection.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 February 2004 Resolved
Properly fit guards on grinding wheels in deck machinery shop.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Pollution Prevention/Response › Prevention Equipment
Issued 4 February 2004 Resolved
Properly fit and attach containment plugs for deck coaming. LEGACY COMPONENT DESC: Coamings
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Fire Fighting
Issued 4 February 2004 Resolved
Hydrostatically test small oxygen bottles in medical space and repair lockers.
Action required: 705 - Other - as specified
Due 24 March 2004
Resolved 1 April 2004
Lifesaving
Issued 4 February 2004 Resolved
Provide and install proper batteries for liferings equipped with waterlights prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2004
Resolution: Ships'''' force purchased and installed proper batteries.
Electrical
Issued 4 February 2004 Resolved
Repair sound powered phone at bow so that pilothouse is audible.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Sound powered phone at bow repaired so that bow and bridge stations are clearly audible.
Fire Fighting
Issued 4 February 2004 Resolved
Properly secure and label semiportable extinguishers located adjacent to ship's helo pad.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Fire Fighting
Issued 4 February 2004 Resolved
Renew protective coating for portable fire extinguisher located at 1-94-2 (garbage/compactor room).
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Fire Fighting
Issued 4 February 2004 Resolved
Repair general alarm in the following spaces: [name withheld], garbage/compactor room, ship's storeroom 'B', adjacent to vestibule 01-109-2 and 01-108-1 (located outside).
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Accommodation/Occupational Safety
Issued 4 February 2004 Resolved
Properly repair burnt-out emergency lights in the following locations: 01-72-4; crew lounge; officer lounge.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Accommodation/Occupational Safety
Issued 4 February 2004 Resolved
Repair burnt-out battle lanterns in the following locations: 06-69-2; 03-72-3; 03-78-4; 01-72-5; medical space; operating station in CPO lounge.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Accommodation/Occupational Safety
Issued 4 February 2004 Resolved
Properly label emergency lighting in gyro room.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Fire Fighting
Issued 4 February 2004 Resolved
Properly return all portable fire extinguishers to their proper location in accordance with the ship's fire control plan and ensure all extinguishers are properly labeled and their label matches the bulkhead numbering system for extinguishers.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Fire Fighting
Issued 4 February 2004 Resolved
Ensure fire station number 76 has all equipment present, including hose and spanner wrench.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Engineering
Issued 4 February 2004 Resolved
Repair & test # 2 boiler aft safety valve. The valve blows outside of valve body.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Engineering
Issued 4 February 2004 Resolved
Conduct operational test of mode 3 on starboard main diesel engine.
Action required: 705 - Other - as specified
Due 24 March 2004
Resolved 1 April 2004
Engineering
Issued 4 February 2004 Resolved
Conduct mechanical overspeed test on both main diesel engines.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Engineering
Issued 4 February 2004 Resolved
Hydo test deck air receiver and install ID plate for CG stamp and install correct size relief valve with ASME approval.
Action required: 705 - Other - as specified
Due 24 March 2004
Resolved 1 April 2004
Engineering
Issued 4 February 2004 Resolved
Replace hoses for hydraulic starting system on emergency diesel generator.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Engineering
Issued 4 February 2004 Resolved
Conduct operational test of the oily water separator.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Engineering
Issued 4 February 2004 Resolved
Properly seal fire stops in engineroom control center at the forward bulkhead and the bulkhead leading to the locker room.
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 17 February 2004
Resolution: A waiting final ruling from MSC to determine if area requires level of protection, before requiring compliance.
Engineering
Issued 4 February 2004 Resolved
Repair or replace (and then test) # 1 boiler aft safety relief valve (currently lifting at 105-110 psi when it is set for 125 psi).
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Accommodation/Occupational Safety
Issued 4 February 2004 Resolved
Install hand rails on ladder leading to platform between ship's service generators.
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 18 February 2004
Fire Fighting
Issued 3 February 2004 Resolved
Replace missing explosion proof cover for heat detector in paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2004
Resolution: Replaced missing explosion proof cover for heat detector in paint locker.
Accommodation/Occupational Safety
Issued 3 February 2004 Resolved
Replace burnt-out emergency light near escape at bottom level of pump room.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Emergency light at bottom level of pump room replaced.
Fire Fighting
Issued 3 February 2004 Resolved
Relabel pullbox in zone 12 (location next to ladder well on main deck)_ - mislabeled zone 1; relabel pullbox in zone 8 (located at engine control room) - also mislabeled zone 1.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Pullboxes were correctly labeled to match their zones.
Fire Fighting
Issued 3 February 2004 Resolved
Properly label open/closed positions for supply/exhaust ventilation dampers in incinerator room.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Ventilation dampers in incinerator room properly labeled.
Fire Fighting
Issued 3 February 2004 Resolved
Properly label open/ closed positions for automatic vent closures for supply/exhaust air for the main diesel engines located on the O-5 and O-7 levels.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Automatic vent closures were properly labeled.
Fire Fighting
Issued 3 February 2004 Resolved
Replace instruction card for paint locker halon system.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: New instruction card generated and replaced.
Fire Fighting
Issued 3 February 2004 Resolved
Properly update instruction card for motor room # 3 halon system to reflect a 60-second time delay.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Instruction card updated.
Accommodation/Occupational Safety
Issued 3 February 2004 Resolved
Replace burnt-out battle lanterns in motor rooms 1 & 2.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Battle lanterns tested and functioning properly.
Fire Fighting
Issued 3 February 2004 Resolved
Make repairs to ensure stairtower fire door FSD 02-69-1 closes properly.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Stairtower fire door FSD 02-69-1 closes properly.
Navigation
Issued 3 February 2004 Resolved
Reset gyro repeater in after steering space and at other repeaters as necessary.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 4 February 2004
Resolution: Gyro repeaters reset.
Electrical › Lighting (emergency)
Issued 21 October 2002 Resolved
Replace batteries for the following battle lanterns: 1) Winch control room, (stbd side); 2) Above the J/W Pump Suction gauge #3; 3) Purifier room, stbd side; and 4) By cargo L/O pump. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 31 October 2002
Resolved 24 October 2002
Resolution: Vessel''''s crew replace all required battle lantern batteries.
Fire Fighting › Structural - A Class Divisions
Issued 21 October 2002 Resolved
Properly repair fire stop in cable penetrations in the emergency diesel generator space. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2002
Resolution: Vessel''s crew properly repaired all fire stops located in the emergency diesel space.
Engineering › Lubricating Oil Service System
Issued 21 October 2002 Resolved
Repair leaking "O" ring in the starboard engine centrifugal filter. LEGACY COMPONENT DESC: Filter
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2002
Resolved 24 October 2002
Resolution: Vessel''s crew replace leaking "O" ring in the starboard engine centrifugal filter.
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Properly secure newly installed electrical wiring with metal bands, in lieu of nylon tie wraps in engineroom. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 24 October 2002
Resolution: Vessel''''''''s crew properly secured newly installed wiring in engineroom with wire bands.
Engineering › Shafting/Propeller Arrangements
Issued 21 October 2002 Resolved
Provide a proper holding bracket for the stern gland pressure cylinder on both the port and stbd sides. LEGACY COMPONENT DESC: Stern Gland
Due 23 November 2002
Resolved 24 October 2002
Resolution: Vessel''s crew properly secured the shaft gland pressure cylinders.
Lifesaving
Issued 21 October 2002 Resolved
Replace bad emergency escape breathing device located in engineroom, lower level, port side, forward. LEGACY COMPONENT DESC: Emergency Escape Breathing Device
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2002
Resolution: Vessel''s crew provided a new emergency escape breathing device for the eningeroom.
Fire Fighting › Means of Escape
Issued 21 October 2002 Resolved
Provide additional label for escape ladder leading from the lower level of the engineroom to the purifier room. LEGACY COMPONENT DESC: Escape Route Signs
Due 30 October 2002
Resolved 24 October 2002
Resolution: Vessel''s crew properly labled escape ladder leading from lower level of the engine room to the purifier room.
Construction/Loadline › Structures
Issued 21 October 2002 Resolved
Make permanent repairs to deck drain piping located in the overhead, forward, port side in the deck water room. LEGACY COMPONENT DESC: Deck Drain
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 29 October 2002
Resolution: Vessel crew permanently repaired deck drain located in the overhead, forward, port side in the deck water room.
Fire Fighting › Miscellaneous Items
Issued 21 October 2002 Resolved
Provide missing spanner wrench for fire station #24. LEGACY COMPONENT DESC: Fire Station Spanner Wrench
Due 30 October 2002
Resolved 24 October 2002
Resolution: Vessel''s crew provided missing spanner wrench for fire station #24.
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Proper install new stuffing tube packing in electrical cable located in the sewage room. LEGACY COMPONENT DESC: Stuffing Tube Packing
Due 30 October 2002
Resolved 24 October 2002
Resolution: Vessel''s crew proper installed packing for stuffing tube in the MSD compartment.
Accommodation/Occupational Safety › Occupational Safety
Issued 21 October 2002 Resolved
Properly stow and secure all refrigerant cylinders in engineroom. LEGACY COMPONENT DESC: High Pressure Cylinders
Action required: 705 - Other - as specified
Due 30 October 2002
Resolved 24 October 2002
Resolution: Vessel''s crew properly secured all refrigerant bottles.
Engineering › Electric Propulsion System
Issued 21 October 2002 Resolved
Prove proper operation of #1 & #2 power take off (PTO) shaft generators. Test reverse power relays and safety shutdowns. LEGACY COMPONENT DESC: PTO Generators
Due 30 October 2002
Resolved 29 October 2002
Resolution: Vessel crew provide proper operation of the #1 & #2 power take off (PTO) shaft generators. Reverse power relays and safety shutdowns tested satisfactory.
Lifesaving › Lifeboat
Issued 21 October 2002 Resolved
Prove proper operation of both the #2 and #4 lifeboats. Passenger count is reduced to 69 until corrected. LEGACY COMPONENT DESC: Gland Seal and Fuel Manifold
Due 1 November 2002
Resolved 1 November 2002
Resolution: Vessel crew proved proper operation of both the #2 and #4 lifeboats.
Fire Fighting › Miscellaneous Items
Issued 21 October 2002 Resolved
Update the vessel's fire control plan to indicate locations of all EEBDs stored on the vessel. LEGACY COMPONENT DESC: Fire Control Plan
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 6 November 2002
Resolution: Vessel does not have a SOLAS Safety Equipment Certificate and therefore not required to have EEBD''s located on fire control plan.
Deck/Cargo
Issued 9 July 2002 Resolved
Make temporary repairs to deck fractures area in way of King Post # 1, 3, 4, 6, 7, and 8. To the satisfaction of the USCG Marine Inspector, to be repaired prior to carrying cargo, NLT 15 August 2002. LEGACY COMPONENT DESC: deck
Condition: Unknown
Due 15 August 2002
Resolved 19 August 2002
Documentation
Issued 9 July 2002 Resolved
Make permanent repairs to King Post # 1, 3, 4, 6, 7, and 8 in accordance with ABS Approved drawing on behalf of the USCG dated MAR 11 2002, Drawing # 600-7373410 Rev A. This must be completed NLT 31 October 2002. LEGACY COMPONENT DESC: approved drawing for King Post
Condition: Unknown
Due 31 October 2002
Resolved 14 October 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 19 June 2002 Resolved
Required inspection on Auxiliary boiler are past due. Vessel must make boiler available for required inspection, or remove boiler, or make boiler unusable by disconnecting all wiring, remove piping to boiler, weld piping access closed and cut a hole into boiler casing.
Due 15 July 2002
Resolved 23 August 2002
Engineering
Issued 28 August 2001 Resolved
PROVE PROPER OPERATION OF PORT MAIN DIESEL ENGINE AFTER REPAIRS ARE COMPLETED AND PROVIDE TECHNICAL REPORT ATTESTING TO SATISFACTORY REPAIRS AND TESTS TO MSO HAMPTON ROADS.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Electrical
Issued 10 January 2000 Resolved
REPAIR & PROVE PROPER OPERATION OF #1 PTO GENERATOR TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Navigation
Issued 10 January 2000 Resolved
Repair or replace magnetic compass provide report to USCG.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Accommodation/Occupational Safety
Issued 10 January 2000 Resolved
Replace relief valve on chill water expansion tank 110 psi or less. 110 psi tank fitted with 130 psi relief valve.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 10 January 2000 Resolved
REPAIR BALLAST PIPING VALVE IN FOREPEAK BALLAST TANK
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Engineering
Issued 10 January 2000 Resolved
LAUNDRY AUXILIARY BOILER FB150-1 NOT IN SERVICE AND NOT BEING MAINTAINED. MOUNTS WERE OPENED AND INSPECTED 10JAN00 ALONG WITH VESSELS 2 AUX BOILERS. LAUNDRY AUXILIARY BOILER SHOULD BE MAINTAINED. AND PERIODICALLY SERVICED USING PRESCRIBED MAINTENANCE PROCEDURES OR REMOVED FROM THE VESSEL ENTIRELY
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Deck/Cargo
Issued 10 January 2000 Resolved
Hydro cargo and bunker lines to the satisfaction of attending CG marine Inspector.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Fire Fighting
Issued 10 January 2000 Resolved
Provide USCG or ABS approval for vessels fire plans.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Lifesaving
Issued 4 December 1998 Resolved
Repair/adjust #1 lifeboat steering nozzle so propeller does not hit it.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Lifesaving
Issued 4 December 1998 Resolved
Repair #4 Lifeboat reverse prior to vessel departing port.
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Fire Fighting
Issued 4 December 1998 Resolved
Provide firefighting servicing report.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Documentation
Issued 4 December 1998 Resolved
PROVIDE AN OIL POLLUTION PLACARD.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Construction/Loadline
Issued 4 December 1998 Resolved
Renew wasted bilge overboard piping.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Deck/Cargo
Issued 4 December 1998 Resolved
Provide copy of Oil Transfer Procedures onboard.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Lifesaving
Issued 24 November 1997 Resolved
In the presents of a CG inspector test pressure relief valves for unrep PVsand tensioner bottles.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Fire Fighting
Issued 24 November 1997 Resolved
Fire alarm pull boxes on main deck corroded and unusable.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Deck/Cargo
Issued 24 November 1997 Resolved
Provide documentation that the ODME has been repaired and the resopnsible crew members have been trained in its use.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Deck/Cargo
Issued 24 November 1997 Resolved
Repair plug threads in noted containments.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Lifesaving
Issued 24 November 1997 Resolved
Replace expired glue and unapproved thermo protective aids on board both rescue boats.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Lifesaving
Issued 24 November 1997 Resolved
Replace unapproved pyrotechnics on all lifeboats.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Lifesaving
Issued 24 November 1997 Resolved
Replace cracked roller in port rescue boat davit.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Lifesaving
Issued 24 November 1997 Resolved
Provide documentation that equipment for oil spill midigation is on board IAW MSCINST 5090.1a
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Deck/Cargo
Issued 24 November 1997 Resolved
Annual Hydro test of cargo piping overdue. Vessel to conduct test at next availability. See MOC-2 ltr dtd March 3, 1997 serial #16711/MSCPAC
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Lifesaving
Issued 24 November 1997 Resolved
Conduct a monthly oil spill drill IAW MSCINST 5090.1a and notify CG when completed.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Lifesaving
Issued 31 January 1997 Resolved
Replace all expired sea sick pills in all lifeboats.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Documentation
Issued 31 January 1997 Resolved
Provide a copy of approve automation procedures.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Electrical
Issued 31 January 1997 Resolved
Repair or replace Uninterupted Power Supply for the Engineroom Power Control console.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Fire Fighting
Issued 31 January 1997 Resolved
Repair automatic vent closure located in the overhead of the incinterator room.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Documentation
Issued 31 January 1997 Resolved
Provide documentation that a Waste management plan and record keeping procedure has been developed.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Lifesaving
Issued 31 January 1997 Resolved
Hydro test all breathing air bottles located in all lifeboats.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Fire Fighting
Issued 31 January 1997 Resolved
Hydor test portable fire extingusher bottles as note on Fire Protection Services' report dated 30MAR97
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Lifesaving
Issued 31 January 1997 Resolved
Replace expired Hydro release for EPIRB.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Documentation
Issued 31 January 1997 Resolved
Master shall provide a written statement that the original COI is aboard and properly displayed.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Deck/Cargo
Issued 16 January 1997 Resolved
Replace lost starboard anchor.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Engineering
Issued 23 September 1994 Resolved
PROVIDE HYDROSTATIC TEST OR MAKE AVAILABLE FOR INTERNAL INSPECTION 26 OVERDUE AIR RECEIVERS.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Engineering
Issued 7 March 1994 Resolved
REPAIR L/O LEAK AT SQUARE FLANGE IN THE LUBE OIL LINE FORWARD OF PORT MDE.
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Construction/Loadline
Issued 7 March 1994 Resolved
WELD BROKEN PIPE HANGER FOR THE SW COOLING OUTLET PIPE FORWARD OF INBOARD COOLER.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Engineering
Issued 7 March 1994 Resolved
REPLACE "FIRE EYE" AND DEMONSTRATE PROPER OPERATION OF THE FLAME FAILURE ALARM ON #2 AUX BOILER.
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Documentation
Issued 7 March 1994 Resolved
UPDATE DEVIATION TABLE.
Condition: Unknown
Due 31 March 1994
Resolved 6 April 1994
Deck/Cargo
Issued 7 March 1994 Resolved
SUBMIT TO THE COGNIZANT OCMI FOR REVIEW & APPROVAL REVISED PLAN REFLECTING THE MODIFICATIONS TO THE CARGO POTABLE WATER PIPING IN THE E/R UPPER LEVEL FWD OF THE ELEVATOR TRUNK.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Engineering
Issued 7 March 1994 Resolved
INSTALL SENSOR FOR POINT ADDRESS NUMBERS S095, P700 & 722.
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Engineering
Issued 7 March 1994 Resolved
SUBMIT TO THE COGNIZANT OCMI FOR REVIEW AND APPROVAL, AN AMENDED AUTOMATIONTEST PROCEDURE.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Electrical
Issued 7 March 1994 Resolved
SUBMIT TO CG HQ (G-MSC) FOR REVIEW AND APPROVAL A REVISED ELECTRICAL PLAN REFLECTING THE INSTALLATION OF THE FOLLOWING:BACK-UP BATTERY SYSTEM FOR PTOGENERATOR CONTROL,SATNAV REPEATER-MASTER OFFICE, KHZ WATCH RECEIVER, & SCBABREATHABLE AIR COMPRESSOR.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Lifesaving
Issued 7 March 1994 Resolved
PROVIDE LIFEBOAT PROVISIONS FOR ALL FOUR LIFEBOATS IN ACCORDANCES WITH 46 CFR SUBCHAPTER "D".
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Engineering
Issued 7 March 1994 Resolved
DEMONSTRATE PROPER OPERATION OF THE LOW WATER ALARM SENSOR FOR NO.2 AUX BOILER.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Engineering
Issued 7 March 1994 Resolved
DEMONSTRATE PROPER OPERATION OF THE MECHNICAL OVERSPEED TRIP OF BOTH MDES UPON ACCUMULATION OF ENOUGH BREAK-IN HOURS FOR THE NEW BEARING. SHOULD THISTIME OCCURS WHEN VESSEL IS UNDERWAY, THE C/E TEST THE OVERSPEED TRIP, LOG RESULTS & PROVIDE COPY TO CG OCMI. _x001C_
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Lifesaving
Issued 24 July 1992 Resolved
Submit plans for modifications made to the general alarm system and the firemain recirculating piping to the marine safety center for approval and provide a copy to the cognizant OCMI.
Condition: Unknown
Due 23 November 1992
Resolved 9 February 1993
Lifesaving
Issued 24 July 1992 Resolved
MOTIFICATIONS TO THE VESSEL'S INTRUSION ALARM AND FIRE MANE AS APPROVED BY G-MSC-2 LETTER OF 25NOV92 SHALL BE MADE AVAILABLE FOR INSPECTION BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.