Records from 1990 to 2025. Most recent: operational control imposed, 9 May 2025.
Inspection history · 150
9 May 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8131584
6 May 2025
Exemption · Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8129386
17 January 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8064996
1 November 2024
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8028220
27 July 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7967861
6 May 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7934393
6 March 2024
ISM SMC Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7875516
5 February 2024
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7861804
21 January 2024
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7852312
20 November 2023
ACP Drydock Oversight · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7836741
21 April 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7673203
21 April 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7685566
3 April 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7709931
20 February 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7640981
17 February 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648528
16 September 2022
Annual Inspection · ACP Annual Oversight · Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7560412
31 August 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7548370
5 February 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7391174
25 October 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7340443
8 August 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7282376
1 May 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7195699
28 April 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7186052
23 October 2020
ACP Drydock Oversight · Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7082717
9 October 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7074428
6 August 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139746
24 July 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139750
7 July 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139748
24 June 2020
COI Inspection · Administrative Inspection · Re-Inspection · ACP COI Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6986060
8 April 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6938132
13 December 2019
Administrative Inspection · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6874222
24 October 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6840815
6 August 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6765765
22 October 2018
ACP Drydock Oversight · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6566262
22 August 2018
ACP Drydock Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6521273
26 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6456320
13 May 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6417540
25 January 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6344239
26 October 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6346722
20 September 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6271388
14 August 2017
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6151994
19 April 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6127990
24 January 2017
Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6082069
29 August 2016
Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 5986290
16 August 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5976941
28 April 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5864392
16 July 2012
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4380357
18 August 2011
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4120108
4 December 2009
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3645572
26 July 2008
Type not recorded
No type recorded · Activities Europe · Activity 3290434
19 April 2008
ACP COI Oversight · COI Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3184261
8 March 2007
MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2883783
13 April 2006
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2594317
1 December 2005
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2546869
24 August 2005
Internal Structural Exam · Damage Survey · Deficiency Check · Cargo Tank Internal · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2393554
24 May 2005
Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2366837
2 May 2005
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2347442
24 March 2005
MTSA/ISPS Verification · MARPOL Annex I Examination · Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2310747
28 February 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2457466
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293586
2 December 2004
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2254115
2 December 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2255259
13 October 2004
Plan Review (Other than "T")
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2221779
3 August 2004
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2154815
28 June 2004
In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2109283
20 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104746
13 May 2004
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2066627
29 April 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2072248
1 April 2004
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2035414
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997488
9 January 2004
Type not recorded
No type recorded · Activities Europe · Activity 2008393
1 July 2003
In-Service Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1853665
7 May 2003
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1788099
13 January 2003
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1759376
6 January 2003
Periodic Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1726150
8 August 2002
Drydock Extension
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1658786
22 July 2002
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1679506
22 June 2002
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1634686
12 June 2002
Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1619252
1 October 2001
Examination of Repairs
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1075260
3 September 2001
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 44478
3 July 2001
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1370283
19 March 2001
Type not recorded
No type recorded · Activities Europe · Activity 1417289
14 March 2001
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1060493
29 September 2000
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 822123
18 August 2000
Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 821902
7 August 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1468592
5 May 2000
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 818161
21 March 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1420306
19 February 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 182036
9 December 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 164995
18 November 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 810856
4 July 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1089479
3 June 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1451409
27 March 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406472
12 March 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 153279
8 February 1999
Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418502
8 December 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 29088
18 November 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 35452
2 November 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 138541
10 August 1998
Administrative
Administrative · Activities Europe · Activity 796536
27 June 1998
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388599
26 June 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 31612
27 March 1998
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375485
18 February 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 74932
22 January 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 92316
15 December 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 95182
23 August 1997
Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 784823
22 May 1997
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1106158
25 April 1997
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1103693
7 March 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1098022
31 October 1996
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1164623
30 September 1996
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1355959
19 March 1996
COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1078909
18 March 1996
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 92273
16 October 1995
Type not recorded
No type recorded · Activities Europe · Activity 60891
16 October 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 136726
16 July 1995
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 90376
29 June 1995
Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1191736
22 March 1995
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 840947
27 March 1994
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 859459
13 January 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 851402
6 January 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 64041
31 December 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 849173
4 October 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1422289
7 August 1993
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 846998
10 November 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 957657
31 July 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 961251
16 July 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 951024
29 June 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 960913
19 June 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 960552
30 May 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469082
28 May 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 958382
23 April 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 950605
20 April 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257108
16 January 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 962678
4 November 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1245982
29 October 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932435
25 September 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 936370
7 June 1991
Excursion Permit · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1234834
6 June 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1237395
4 April 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1230306
1 April 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1223366
8 January 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918968
2 January 1991
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 926798
10 December 1990
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1229666
3 December 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 913188
1 November 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1246157
3 August 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218949
25 July 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910541
6 July 1990
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220558
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 January 2024
Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. The port AFFF monitor is inoperable due to a 5" x 2" rupture in the line. Make permanent repairs to the system to the satisfaction of class.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2024
Resolved 30 January 2024
Resolution: Section of AFFF pipe was removed flange to flange and straight section of pipe with burst section replaced and pressure tested at Propulsion Controls Engineering Bremerton.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2023
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessels port and starboard main propulsion systems failed and vessel lost propulsion while underway. Conduct root cause analysis and perform main propulsion control system groom, provide findings to Sector San Diego.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2023
Resolution: Received class report that def was corrected by replacing cluth pressure regulator air filters.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2023
Resolved
Tank Deck AFFF system suffered the following casualties:
-Spool for Monitor One (01) at frame 33, developed a large hole with 200 gal/min escaping the hard piping system.
-during test for Zone Two (02), no water flow was coming from the sprinklers.
-fire and ballast pump could not be stopped after activation.
Liquid cargo operations are restricted until repairs to the AFFF fire monitor and sprinkler system are made to the satisfaction of Class.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2023
Resolution: Cannot conduct cargo liquid transfer operations until def has been rectified. 25MAR23 successful test of system witnessed by RO
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 February 2023
Resolved
A person may not employ or engage an individual, and an individual may not serve in a position in which it is required by law or reguation that the individual hold an MMC endorsed with a national endorsement, as well as a corresponding endorsment for service outside the boundary line. The mariner filling the chief engineer position has an incorrect propulsion type allowance on their STCW endorsement as Chief Engineer and OICEW.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 February 2023
Resolution: Mariner worked with NMC to rectify error on credential.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 February 2023
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Mariner in the postion of bosun/AB-Deck was found with expired national medical certificate.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 11 February 2023
Resolution: Mariner was replaced with another crew member appropriately credentialed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 February 2023
Resolved
The normal equipment of a fast rescue boat shall include a VHF radiocommunication set which is watertight. Due to flooding damage, VHF on port side rescue boat no longer functional. LSA 5/5.1.4.11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 17 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 February 2023
Resolved
Every lifeboat to be launched by fall or falls, except free-fall lifeboat, shall be fitted with a release mechanism complying with the following requirements: the release mechanism shall be so arranged that all hooks are released simultaneously. During inspection, Marine Inspectors found that lifeboat #1 could not release on-load without a significant delay in release of aft and forward release hooks. Additionally, crew appears to regularly practice bypassing the on-load release procedure during operational tests/drills.
74 SOLAS (20) III/34; LSA 4/4.4.7.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2023
Resolution: Witnessed testing of on-load release. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 February 2023
Resolved
During preparation and launching, the survival craft, its launching appliance and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from emergency source of electrical power required by regulation II-1/42 or II-43, as appropriate. Marine Inspector found that all lights that point into water on starboard side, and all but one on port side, for survival craft launching/embarkation/recovery are not operable.
74 SOLAS (97) III/15.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
Resolution: Witnessed operation of the e-lights for the lifesaving embarkation stations.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 February 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported to Marine Inspectors that both rescue boats are inoperable due to flooding from rain damage. 74 SOLAS (20) I/11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2023
Resolution: Witnessed testing of both FRBs. Port side boat radio INOP. Wrote up in Def #23.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. International Shore Connection missing from location listed on Fire Control Plan. 74 SOLAS (20) I/11(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 February 2023
Resolved
Any required...fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. Marine Inspector found trouble indication on fire alarm panel and found several fire detectors that were disconnected and hanging from their mounts. 74 SOLAS (81 Amended) II-2/12.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2023
Resolution: Crew replaced detectors and trouble alarm resolved. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 February 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Watertight door indicator in ECR for WTD at Frame 102 inoperable: doesn’t indicate if door is open/closed. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: Tested door after crew replaced light bulb. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 6 February 2023
Resolved
Structural members...and all other fittings used in connection with launching equipment shall be designed with not less than a minimum safety factor on the basis of the maximum working load...a minimum safety factor of 4.5 shall be applied to all davit and winch structural members. Port side rescue boat davit designed as a tilting davit, however due to long term deterioration and painting over of components it has been seized in place. Vessel to secure all pivot points by mechanical fastening/welding to ensure boat does not accidentally shift and prove proper launching utilizing only davit. 74 SOLAS (97) III/ 48.1.8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: Welds put on davit to prevent from tilting. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 February 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Life ring located at starboard rescue boat was found missing. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: Life ring and bracket replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2023
Resolved
Firefighter’s outfit. Personal equipment shall consist of electrical safety lamp of an approved type...Electric safety lamp on tankers and those intended to be used in hazardous areas shall be of an explosion proof type and axe with a handle provided with high-voltage insulation. During fire drill, firefighters were found to be without radios and axes. SOLAS (20) II-2/10.1.1 FSS Code 3.2.1.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 13 February 2023
Resolution: 10FEB: Radios provided, axes still outstanding.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2023
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Wiring for general alarm at aft port side of midships unrep station found to be routed through a sharp edged rat hole and spliced outside of junction box. Make repairs to include proper weather-tight cable transit and make wiring connections inside junction box. 74 SOLAS (04) II-1/45.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: New cable transit and now spliced inside junction box. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2023
Resolved
Where necessary, relatively tight compartments such as refrigeration spaces, paint lockers, etc., shall be provided with suitable means for relieving excessive pressure accumulating within the compartment when the carbon dioxide is injected. Door to forward cargo store room installed backwards. Does not open outwards from fixed gas system. U.S. Supplement ABS 2003
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 13 February 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 February 2023
Resolved
A general emergency alarm system complying with requirements of regulation 50 shall be provided. General alarm bell on starboard side aft of house found disconnected and missing. 74 SOLAS (97) III/6.4.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 10 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2023
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. A/C unit that services ammunition locker base is wasted. Crew could not determine if unit worked or not. Temperatures in ammunition locker showed evidence of exceeding 100 degrees F. Unit is being held up with lashings. Repair base and install A/C unit to satisfaction of ABS. 74 SOLAS (04) II-1/40.1.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 10 February 2023
Resolution: A/C unit removed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 6 February 2023
Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. The height of the bulwarks or guard rails shall be at least 1m from the deck. Marine Inspectors found damage to rail on aft corner, starboard side, of forecastle. Crew stated that this was damaged from a crane operation at the shipyard. Additionally, damage was done to a blue light on rail just aft of Forecastle. Make repairs to satisfaction of ABS. ICLL (88) II/25(2)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 17 February 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector found multiple kick pipes for deck equipment wasted on the 01 deck. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 17 February 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 6 February 2023
Resolved
Each nonmetallic transfer hose must: Have no unrepaired loose covers, kinks, bulges, soft spots or any other defect which would permit the discharge of oil or hazardous material through the hose material, and no gouges, cuts or slashes that penetrate the first layer of hose reinforcement as defined in § 156.120(i)...Have no external deterioration and, to the extent internal inspection is possible with both ends of the hose open, no internal deterioration... Hoses not meeting the requirements of paragraph (c)(1)(i) of this section may be acceptable after a static liquid pressure test is successfully completed in the presence of the COTP. The test medium is not required to be water. Marine inspectors found that virtually all cargo transfer hoses showed signed of external deterioration. Hoses shall be subject to additional inspection and testing prior to being returned to service. 33 CFR 156.170
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 February 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 6 February 2023
Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have on board an emergency means to enable the person in charge of a transfer operation to a facility, to another vessel, or within the vessel to stop the flow of oil or hazardous material. Emergency shutdowns throughout the vessel were found to have unreadable signage, exposed wiring, or broken covers. 33 CFR 155.780(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2023
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 6 February 2023
Resolved
A ship of 300 gross tons or more constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow, and fill pipe. Marine Inspector found several containment plugs missing. 33 CFR 155.320(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2023
Resolution: Containment plugs replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. HP Pressure tank system on the cargo deck found with multiple painted over and zip tied
pressure relieving devices while in service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 February 2023
Resolution: Paint removed. Plates visible. Some data not legible. Crew plans to replace plates.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2022
Resolved
Annual Inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Due to vessel conducting repairs vessel has gone past 3 month limit. Schedule a date to renew prior to movement of vessel.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 February 2023
Resolution: Vessel completed ACP Annual Inspection.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 31 August 2022
Resolved
Un approved modification was made in way of the transverse expansion joint on the 01 level at frame 56.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 February 2023
Resolution: Unapproved modification was removed satisfactorially.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 January 2022
Resolved
A self-contained emergency source of electrical power shall be provided. Ship crew reported that EDG shut down after over-speeding, in addition that local and switchboard stop switch are not operating as intended.
74 SOLAS (2004) II-I REG 43.1.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2021
Resolved
A self-contained emergency source of electrical power shall be provided. EDG is inoperable due to small fire shall be provided. EDG is inoperable due to small fire IWO of generator exhaust manifold. Conduct root causal analysis, Repair to OEM specifications, and to the satisfaction of RO.
74 SOLAS (2004) II-I REG 43.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 December 2021
Resolved
Means shall be provided to close all openings which may admit air to or allow gas to escape from a protected space. 06-92-1 Engine room air supply damper louvers are inoperable.
74 SOLAS (1997) II-2 Reg 5.1.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 January 2022
Resolution: ABS Surveyor [name withheld], witness sat repair and operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 December 2021
Resolved
Every ship shall be provided with fire pumps, fire mains, hydrants, and hoses complying with applicable requirements of this regulation. During operational test Fire main expansion joint ruptured IWO main deck P/S ZONE 3.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 January 2022
Resolution: ABS Surveyor [name withheld], witness sat repair and operation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 December 2021
Resolved
The ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. INOP bilge alarm IWO aft P/S pump room. 74 SOLAS (2020)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 January 2022
Resolution: ABS Surveyor [name withheld], witness sat repair and operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 May 2021
Resolved
Faulty current transformer for #4 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 July 2020
Resolved
Title 46, CFR, Part 113.25-12 (b): Each general emergency alarm signal must be an electronically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. Repair and prove operation of the following general alarms: 1 x general alarm in way of SWB P4 Tank, port side on tank top, 2 x general alarms in way of fire station no. 61, port side, 1 x general alarm in way of fire station no. 63, port side, 1 x general alarm with inoperable bell in aft truck tunnel, 1 x general alarm with inoperable rotating light in aft truck tunnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 July 2020
Resolved
74 SOLAS (2014) Chapter III, Regulation 20.10: Containers, brackets, racks and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with recommendations of the Organization, indication the devices stowed in that location for that purpose. Replace missing symbols for ring buoys with attached float light at the following locations: 2 x on port side tank top and 1 x focsle near intake no. 02-12-2 Supply vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2020
Resolved
74 SOLAS (2014) Chapter II-2, Regulation 14.2.2.1: Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner due regard to ensuring the reliability of fire-fighting systems and appliances. Portable fire extinguishers throughout house and work spaces were inspected with overdue annual service tags as of June 2020. Per vessel’s Captain, 3rd party service technician is scheduled to attend the vessel in Guam before end of July to complete inspection of vessel’s firefighting detection/suppression and portable extinguishers. Submit copy of inspection/service report to Sector Guam.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 2 July 2020
Resolved
Oil filtering equipment referred to paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. MARPOL Annex 1/14: In addition, it shall be provided with alarm arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 parts per million. Vessel was unable to demonstrate that the oily water separator and oil content meter is operating as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 1 July 2020
Resolved
74 SOLAS (2014) Chapter 1, Regulation 11: The condition of the ship and its equipment shall be maintained to confirm with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Repair sound power powered phones at the following locations and prove operation: Focsle and in Motor Rooms 1, 2 and 3.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 July 2020
Resolved
74 SOLAS (2014) Chapter III, Regulation 20: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Repair and prove operation of Rescue Boat compass and nav horn.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2020
Resolved
74 SOLAS (2014) Chapter II-2, Regulation 14.2.2.1: Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner due regard to ensuring the reliability of fire-fighting systems and appliances. CO2 flooding system for Motor Rooms 1, 2 and 3 displays incorrect time delay of 20 seconds for exiting spaces. Time delay units are marked with minimum time delay of 60 seconds. Update placards with correct time delays for motor rooms 1, 2 and 3.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 1 July 2020
Resolved
ICLL (1966) Annex I, Regulation 8: The ring, lines, letters shall be painted in white or yellow on a dargk ground or in black on a light ground…The marks shall be plainly visible. Paint in contrasting color starboard deck line per vessel's current International Load Line Certificate to the satisfaction of Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 July 2020
Resolved
74 SOLAS (2014) Chapter I, Regulation 11: The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service they are intended. Repair COJP low suction wheel valve with vice-grip on gland bolt to as original.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2020
Resolved
74 SOLAS(14) II-1/54.4.1: The control system shall be such that the services needed for the operation of the main propulsion machinery and its auxiliaries are ensured through the necessary automatic arrangements. One of the three main engine's salt water stand-by cooling pump could not auto start and change over upon loss of pressure from the primary cooling pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 October 2018
Resolved
Ventilator openings and air pipes shall be provided with weather tight closing appliances. Vessel was found with multiple ventilator closures on main deck and 01 deck missing hardware, painted over, corroded or otherwise incapable of being closed. ILLC Reg 19.4 and Reg 20.
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: All closures were re-insepcted and found to be operable and in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 23 October 2018
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The Port Side rescue boat davit experienced hydraulic hose failure during testing rendering davit INOP and rescue boat unable to be launched or recovered. Solas 74 (14 amend) III/20.1
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Vessel crew found loose fittings and properly secured, tested and demonstrated proper operation to the satisfaction of the attending CG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2018
Resolved
The machinery, associated piping, and fittings shall be so installed and protected to reduce to a minimum any danger to persons on board. The Emergency Generator Set prime mover was found leaking diesel fuel from fuel hose fitting and filter housing during operational testing. SOLAS 74 (83 amend) II-2 Reg 26.1
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: New o-ring and gasket installed, tested and verified satisfactory by attending CG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 October 2018
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The #2 lifeboat sliding door was found missing hardware and not able to be properly secured closed. Solas 74 (14 amend) III/20.1
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Vessel crew replaced missing hardware as required and verified by attending CG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chaffing and other damage. Overhead wiring adjacent to emergency generator access hatch was found unsupported due to broken clip on framing. Solas 74 (83 amend) II-2/45/5.5
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: New wire support installed as required and verified by CG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018
Resolved
After any survey of the ship has been completed, no change shall be made in the structural integrity, machinery, or equipment covered by the survey without the sanction of the Administration. Addition of cooling fan in steering room needs approved and permanently installed to include proper utilization of junction boxes and wire supports as appropriate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2018
Resolved 14 November 2018
Resolution: Fan wiring properly installed as required.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 October 2018
Resolved
Provide proper batteries for all onboard water lights. Water lights on bridge wings have a max weight requirement of 1.49 lbs. Installed batteries have weight of 1.95 lbs. None of the water light batteries throughout the vessel are listed on the manufactures recommended battery list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2018
Resolved 14 November 2018
Resolution: ABS accepted CG835V, issued finding number 1604 to replace batteries as required.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 28 September 2016
Resolved
No lifeboat launching instructions.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 September 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 September 2016
Resolved
Grab lines on 4 Liferings in substandard condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2016
Resolved 28 September 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 28 September 2016
Resolved
Spare extinguishers not properly stowed in foam room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 September 2016
Electrical › Electric Generation Source (service) › Generator Cable
Issued 28 September 2016
Resolved
Number 4 Generator had bad tie to switchboard
Condition: Damaged By Earlier Event
Due 28 October 2016
Resolved 28 September 2016
Resolution: vessel tested generator in presence of ABS surveyor.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 September 2016
Resolved
EBIRBs not registered with NOAA
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 September 2016
Resolution: Master produced email from NOAA acknowledging receipt of registration.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 16 August 2016
Resolved
#SSDG 3 had a alarm light for ground, vessel crew took the generator off line and secured operation until furhter troubleshooting can be done. Request proper repair, and operatinal test.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 February 2018
Resolution: Multiple USCG and class surveys have been carried out with no outstanding remarks concerning this issue.
Engineering › Steering Gear System › Follow-up Assembly
Issued 18 April 2008
Resolved
Make permanent repairs to the Starboard Steering Unit to provide follow-up steering in accordance with 46 CFR 58.25-70(h).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2008
Resolved 21 April 2008
Resolution: Faulty Circuit board was renewed. Test of steering system in all modes is satisfactory.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 June 2005
Resolved
Provide a copy of the port and stbd propellers' survey report.
Due 24 September 2005
Resolved 14 September 2005
Resolution: Received report.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 24 March 2005
Resolved
Provide cargo tank overfill alarm that is visible in the cargo deck area iaw 46 CFR 39.20-7(d)(2) & 33 CFR 155.480 not later than completion of next drydock. Extension request to OCT 05 ROH granted
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 1 December 2005
Resolution: Witnessed SAT op test
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 24 March 2005
Resolved
Provide embarkation ladder that meets 46 CFR 199.110(f)(2)
Condition: Improper Installation
Due 24 April 2005
Resolved 2 May 2005
Resolution: CO called 4/22. Witnessed install 5/2.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 24 March 2005
Resolved
Prove proper operation of water spray sprinklers on #3 motor lifeboat
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2005
Resolution: Pump replaced, test SAT
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 March 2005
Resolved
Permanently affix IMO number to vessel IAW SOLAS XI/3 by completion of next drydock.
Due 31 July 2005
Resolved 24 August 2005
Resolution: IMO number permanently affixed.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 24 March 2005
Resolved
Provide access to vent duct hatch on portside of winch room bulkhead
Due 24 April 2005
Resolved 25 March 2005
Resolution: Plate welded to blkhd to provide access
Fire Fighting › Structural - A Class Divisions › Cargo Spaces (moderate fire risk)
Issued 24 March 2005
Resolved
Provide proper SFP to bulkhead penetration packing for cable TV on winch room bulkhead.
Due 24 April 2005
Resolved 25 March 2005
Resolution: packed
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 24 March 2005
Resolved
Prove proper operation of exhaust damper 07-92-7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2005
Resolution: solenoid replaced, test SAT
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 24 March 2005
Resolved
Revise periodic safety test procedures.
Due 24 June 2005
Resolved 25 March 2005
Resolution: CE to combine Rev C with existing and tailor to vessel
Electrical › Electric Generation Source (service) › Power Requirement
Issued 2 December 2004
Resolved
Repair and prove proper operation of the following malfunctioning vessel systems: 1) ships SSDG standby and auto call up functions. 2) cargo pump shunt trips used for load shedding 3) PTO generator alarm monitoring system on the engine room control console 4) Reason why the #1 and #2 PTO tripped offline during unrep operations with the USS NIMITZ
Due 28 February 2005
Resolved 24 March 2005
Resolution: Witnessed SAT repairs and op test
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 8 July 2004
Resolved
Prove proper operation of safety relief valve on #2 start air receiver.
Due 22 July 2004
Resolved 3 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 July 2004
Resolved
Hard wire industrial fans or remove while under way.
Due 22 July 2004
Resolved 19 July 2004
Resolution: 19 July 2004- Ships company removed industrial fans from service. [name withheld]
Fire Fighting › Automatic Sprinkler System › Piping
Issued 28 June 2004
Resolved
Install proper piping for AFFF sprinkler system.
Due 31 October 2005
Resolved 13 April 2006
Resolution: ABS surveyor deferred requirement to next scheduled drydock. Vsl to install proper piping for AFFF sprinkler system at next scheduled drydock.
Operations/Management › Drills/Instruction › Fire
Issued 28 June 2004
Resolved
Prove ability to conduct fire drill properly.
Due 22 July 2004
Resolved 19 July 2004
Resolution: 19 July 2004- Observer a sucessful fire drill. [name withheld]
Engineering › Diesel Engine (propulsion-electric)
Issued 13 May 2004
Resolved
Replace ruptured head to manifold cooling branch line on STBD MDE
Condition: Improper Installation
Due 13 May 2004
Resolved 13 May 2004
Lifesaving › Immersion Suits › Serviceable
Issued 22 April 2004
Resolved
Repair or renew all immersion suits to bring total to at least 143 as required by the COI. Vessel is restricted to 102 persons until full complement is achieved.
Condition: Improper/Lack of Maintenance
Due 16 May 2004
Resolved 8 July 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 22 April 2004
Resolved
Remove all flammable liquids stored in cargo storeroom 01-27-1 until a satisfactory fixed fire extinguishing system is installed. 46CFR147.45 and 46CFR34.05-5(3)
Condition: Unknown
Due 16 May 2004
Resolved 8 July 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 22 April 2004
Resolved
Make permanent repairs to wasted exhaust vent door on forecastle near frame 18.
Condition: Improper/Lack of Maintenance
Due 16 May 2004
Resolved 8 July 2004
Lifesaving › Launching Appliances › Falls
Issued 22 April 2004
Resolved
Provide original lifeboat wire rope (cable) approval calculations for review. Also provide the breaking strength of the eight (8) swaged thimble fittings attached to the turnbuckles (current test is for 31,000 lbs). 46 CFR 199.153(c). LEGACY COMPONENT DESC: Davit
Condition: Unknown
Due 16 May 2004
Resolved 8 July 2004
Construction/Loadline › Structures
Issued 1 April 2004
Resolved
Make permanent repairs to wasted padeye and runner/messenger IWO RAS #6.
Due 30 April 2004
Resolved 22 April 2004
Resolution: Cleared
Engineering › Steering Gear System
Issued 7 May 2003
Resolved
See Activity 1788099 Narrative for details on the requirements of this CG-835.
To be cleared only by [name withheld], Far East. LEGACY COMPONENT DESC: Rudder Bearing
Action required: 705 - Other - as specified
Resolved 15 August 2003
Resolution: Requirement was recinded.
Engineering › Steering Gear System
Issued 15 January 2003
Resolved
Submit detailed request to [name withheld], providing support for an extended time interval for inspection of lower pintle bearings. This package shall include but is not limited to original specifications and readings, all subsequent readings, comparisons to other vsl's in the same class. LEGACY COMPONENT DESC: Rudder Bearing
Condition: Improper/Lack of Maintenance
Due 14 April 2003
Resolved 7 May 2003
Resolution: Re-issued requirement with further guidance.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 6 January 2003
Resolved
Renew all damaged flame screens
Condition: Improper Installation
Due 15 January 2003
Resolved 15 January 2003
Resolution: Flame sceens renewed.
Construction/Loadline › Structures › Air Pipe
Issued 6 January 2003
Resolved
Repair bent dog on ventilation closure on focsl'e
Condition: Damaged By Earlier Event
Due 15 January 2003
Resolved 15 January 2003
Resolution: Dog was replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 January 2003
Resolved
Make permanent repair or remove emergency, towing gear, box. LEGACY COMPONENT DESC: Physiacal Hazard
Condition: Unknown
Due 15 January 2003
Resolved 15 January 2003
Resolution: Box was removed.
Electrical › Lighting (service) › Conductor
Issued 6 January 2003
Resolved
Renew electrical cable for lighting on focsl'e.
Condition: Unknown
Due 15 January 2003
Resolved 15 January 2003
Resolution: Cable renewed.
Electrical › Lighting (service) › Conductor
Issued 6 January 2003
Resolved
Repair cable way supports on focsl'e where wasted.
Condition: Unknown
Due 15 January 2003
Resolved 15 January 2003
Resolution: Cable supports renewed.
Electrical › Lighting (service) › Outlet Box
Issued 6 January 2003
Resolved
Remove or properly install newly installed wiring in Fork Lift Shop.
Condition: Placed in Improper Service
Due 15 January 2003
Resolved 15 January 2003
Resolution: Outlet renewed with proper equipment and cable properly supported.
Electrical › Electrical Distribution System (service) › Cable
Issued 6 January 2003
Resolved
Remove or properly terminate dead end cable in forward truck tunnel.
Condition: Improper Installation
Due 15 January 2003
Resolved 15 January 2003
Resolution: Cable was removed.
Lifesaving › Lifejacket/PFD (Type III)
Issued 6 January 2003
Resolved
Remove all "Type III" pfd's.
Condition: Placed in Improper Service
Due 15 January 2003
Resolved 15 January 2003
Resolution: Type III PFD''s were removed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 January 2003
Resolved
Repair leak on Cargo DFM piping.
Condition: Improper/Lack of Maintenance
Due 15 January 2003
Resolved 15 January 2003
Resolution: Flange was removed and new gasket installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 January 2003
Resolved
Properly insulate shore steam connection. LEGACY COMPONENT DESC: Insulation
Condition: Improper/Lack of Maintenance
Due 15 January 2003
Resolved 15 January 2003
Resolution: Insulation installed.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 6 January 2003
Resolved
Make permanent repairs to #2 lifeboat door seal.
Condition: Improper/Lack of Maintenance
Due 15 January 2003
Resolved 15 January 2003
Resolution: Door seal was reattached and seals properly.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 6 January 2003
Resolved
Make permanent repairs to #2 lifeboat sprinkler system.
Condition: Improper/Lack of Maintenance
Due 15 January 2003
Resolved 15 January 2003
Resolution: Make permanent repairs to #2 lifeboat sprinkler system.
Navigation › Piloting/Steering
Issued 6 January 2003
Resolved
Repair speed indicator on the bridge. LEGACY COMPONENT DESC: Speed indicator
Condition: Unknown
Due 15 January 2003
Resolved 15 January 2003
Resolution: Electrical power was restored.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 January 2003
Resolved
Replace bulbs as required in all running lights.
Condition: Improper/Lack of Maintenance
Due 15 January 2003
Resolved 15 January 2003
Resolution: Elements were replaced.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 January 2003
Resolved
Make change in automation indicating when a standby pump auto starts from stand-by mode. LEGACY COMPONENT DESC: Alarm
Condition: Improper Installation
Due 15 January 2003
Resolved 15 January 2003
Resolution: Summary alarm installed.
Deck/Cargo › Holds/Tanks
Issued 6 January 2003
Resolved
Properly mark F/O deep tanks with "DANGER DO NOT ENTER". Make access to the tank more difficult to prevent personnel injury. LEGACY COMPONENT DESC: Marking
Condition: Improper Installation
Due 15 January 2003
Resolved 15 January 2003
Resolution: Nuts and washers used to replace dogs. One dog drilled and pinned to prevent opening. Hatch properly marked.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 6 January 2003
Resolved
Make permanent repairs to paint locker halon system timer. LEGACY COMPONENT DESC: Timer
Condition: Improper/Lack of Maintenance
Due 15 January 2003
Resolved 15 January 2003
Resolution: Timer was repaired by servicing technician
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 6 January 2003
Resolved
Refill empty halon bottle in after steering fixed system.
Condition: Unknown
Due 15 January 2003
Resolved 15 January 2003
Resolution: HALON was replaced.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 6 January 2003
Resolved
Repair leaks on CO2 activation hose fittings in main space halon system. LEGACY COMPONENT DESC: Control Valve
Condition: Unknown
Due 15 January 2003
Resolved 15 January 2003
Resolution: Leaking O''''rings were renewed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 6 January 2003
Resolved
Properly maintain halon and CO2 cylinders to emergency generator room fixed fire fighting system.
Condition: Improper/Lack of Maintenance
Due 15 January 2003
Resolved 15 January 2003
Resolution: Tanks were cleaned and painted by servicing company.
Construction/Loadline › Hull › Girder
Issued 2 January 2003
Resolved
Make permanent repair to garbage chute hatch and water wash penetration.
Condition: Improper/Lack of Maintenance
Due 16 January 2003
Resolved 15 January 2003
Resolution: Mechanism rebuilt.
Electrical › Electric Supply System (service)
Issued 23 December 2002
Resolved
Properly markfryer disconnect swtch. LEGACY COMPONENT DESC: Diconnect Switch Markings
Condition: Improper Installation
Due 23 January 2003
Resolved 15 January 2003
Resolution: Disconnects and breakers were properly marked.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System
Issued 8 August 2002
Resolved
Provide additional AFFF (40%) to meet vsl's required 100% capacity. LEGACY COMPONENT DESC: Quantity of Foam
Due 21 August 2002
Resolved 15 August 2002
Resolution: Additional 40% AFFF placed on board vsl, in designated storage tank, prior to sailing. All sat.
Electrical › Electrical Distribution System (service)
Issued 12 June 2002
Resolved
At next scheduled yard period make permanent repairs to cable splicing in way of penetration at frame 60 and at inboard window of supply office. Prior to repair, submit proposal for review to the [name withheld]: Cable
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 14 January 2003
Resolution: All cables and penetration were repaired.
Engineering
Issued 21 March 2000
Resolved
Hydro test auxiliary boilers prepare boilers for an internal inspection.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Fire Fighting
Issued 21 March 2000
Resolved
Replace improper roller fire door motor and junction box (indoor rated) at fwd stores with appropriate weather proof unit. Complete and provide satisfactory evidence to USCG OCMI prior to 15 May 2000.
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Lifesaving
Issued 27 March 1999
Resolved
End for end lifeboat falls prior to 31 March 1999 or renew falls prior to 31 May 1999.
Condition: Unknown
Due 31 May 1999
Resolved 22 June 1999
Construction/Loadline
Issued 27 June 1998
Resolved
Complete hull repairs in way of portside corner in frames 59-71. Repairs are to be completed as per proposed hull repairs submitted on 10 Jul 98.
Condition: Unknown
Due 27 June 1998
Resolved 27 June 1998
Lifesaving
Issued 27 March 1998
Resolved
Repair port and starboard rescue boats.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Engineering
Issued 27 March 1998
Resolved
Repair leaks on main cooling system._x001C_
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Engineering
Issued 27 March 1998
Resolved
REPAIR #1 AUX BOILER AND PROVE SAT OPERATIONAL TEST TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Construction/Loadline
Issued 25 April 1997
Resolved
repair ballast control monitor.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Accommodation/Occupational Safety
Issued 19 March 1996
Resolved
PROVIDE TESTING CERTIFICATES FOR HIGH PRESSURE RELIEF VALVES, FOR FAS AND RAS STATIONS 1-8. ITEM TO BE CLEARED BY FAX COPY OF CERTIFICATES TO MIDET SINGAPORE INSPECTION OFFICE (65) 750-2357.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Navigation
Issued 22 March 1995
Resolved
REPAIR AND PROVE PROPER OPERATION OF FATHOMETER AND RECORDER.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Lifesaving
Issued 22 March 1995
Resolved
REPLACE ALUMINUM ROLLERS ON PORT AND STARBOARD RESCUE BOAT DAVITS WITH ROLLERS OF A COMPATIBLE MATERIAL AND PROVIDE MEANS OF LUBRICATION.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 7 August 1993
Resolved
REWRITE & TAILOR VESSEL AUTOMATION PROCEDURES TO REFLECT ACTUAL TESTING PROCEDURES AND RESUBMITT FOR AN APPROVAL TO COGNIZANT OCMI.
Condition: Unknown
Due 7 August 1993
Resolved 7 August 1993
Construction/Loadline
Issued 10 November 1992
Resolved
PROVIDE REFERENCE VIDEO FOR UNDERWATER IN LIEU OF DRYDOCK PROGRAM.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Lifesaving
Issued 19 June 1992
Resolved
CONDUCT DAVIT LOAD TEST TO LIFEBOAT DAVIT #3 AND #4 AND CONDUCT WEIGHT/RELEASE TEST TO LIFEBOAT #2, #3 AND #4. THIS ITEM CAN BE CLEARED BY SUBMITTING LOG BOOK ENTRY AND PICTURES OF SATISFACTORY TESTS TO [name withheld], HI.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Engineering
Issued 19 June 1992
Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR 15 PPM ALARM.
Condition: Unknown
Due 19 June 1992
Resolved 19 June 1992
Lifesaving
Issued 30 May 1992
Resolved
CONDUCT PERMANENT REPAIRS TO TEMPORARY PATCH ON #4 LIFEBOAT, PORTSIDE, 4 FEET FROM BOW AND 3 FEET ABOVE KEEL.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Documentation
Issued 1 April 1991
Resolved
PRODUCE OIL TRANSFER PROCEDURES AS PER 33 CFR 155.720 AND 155.750 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Deck/Cargo
Issued 1 April 1991
Resolved
CARRIAGE OF GRADE "D" CARGO IS PROHIBITED IN #10 CENTERLINE CARGO TANK,(ANYCARGO WITH FLASH POINT BELOW 150 DEGREES F) UNTIL DOCUMENTATION IS PROVIDEDTHAT THE JP-5 IS IN FACT A GRADE "E" VICE GRADE "D" PRODUCT.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Electrical
Issued 1 April 1991
Resolved
PROVIDE APPROVAL AND EXEMPTION FROM REGS TO INSTALL INTRUDER ALARM TIED TO GENERAL ALARM CIRCUIT AND PROVIDE PROOF OF MEETING THE REGULATIONS AS PER 46 CFR 113.25-6 AND 113.25-12.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Unknown
Issued 1 April 1991
Resolved
PROVIDE APPROVED PLANS FOR NEW INSTALLATIONS OF ALARM SYSTEMS, E/R ESCAPE PTO CONVERTER CABINET SPACE, FIRE PUMP AND FIRE & BALLAST PUMP CONTROLLERS COMPRESSED AIR SYSTEM, ETC. TO THE SATISFACTION OF THE COGNIZANT OCMI
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Unknown
Issued 3 December 1990
Resolved
TAG OUTBOARD STARTING AIR RECEIVER OUT OF SERVICE. PROVIDE A COAST GUARD APPROVED WELDING PROCEDURE & WELDER'S QUALIFICATION & PERFORMANCE PRIOR TO STARTING WELDING HOLDING BRACKETS FOR THE STARTING RECEIVER.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Unknown
Issued 3 December 1990
Resolved
WELDING OF THE BRACKETS TO THE OUTBOARD STARTING RECEIVER SHALL BE X-RAYED AND RECEIVER HYDROTESTED TO 1.5 TIMES MAXIMUM ALLOWABLE WORKING PRESSURE IN THE PRESENCE OF A CG MARINE INSPECTOR PRIOR TO PLACING RECEIVER IN SERVICE.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Engineering
Issued 6 July 1990
Resolved
PROVIDE EVIDENCE OF USCG APPROVAL OF UPS SYSTEM SERVING THE MAIN ERC CONSOLE.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Electrical
Issued 6 July 1990
Resolved
RE-ATTACH OVERHEAD LIGHTS AND REPLACE BURNT-OUT BULBS IN THE FORWARD PAINT LOCKER, MAIN DECK.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Lifesaving
Issued 6 July 1990
Resolved
EQUIP ALL REQUIRED EXPOSURE SUITS (IMMERSION SUITS) WITH ATTACHED LIGHTS AND WHISTLES.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990