USNS PECOS

USNS PECOS is a 1990 tank ship. The Coast Guard has recorded 45 inspections since 2016, most recently in May 2025, along with 56 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: operational control imposed, 9 May 2025.

Built
1990
Last inspected
9 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 May 2025
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8706686
313345
Flag
UNITED STATES
Maury page id
psix-313345

Documentation record

Tonnage as PSIX records it8992 - Convention (Subpart B), Net Ton
18987 - Regulatory (Subpart C or D), Net Ton
27671 - Dead Weight, Ton
42383 - Displacement, Ton
25742 - Convention (Subpart B), Gross Ton
20706 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

45 inspections, each with its date, unit and type; 56 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 45

9 May 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8131584
6 May 2025 Exemption · Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8129386
17 January 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8064996
1 November 2024 Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8028220
27 July 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7967861
6 May 2024 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7934393
6 March 2024 ISM SMC Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7875516
5 February 2024 Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7861804
21 January 2024 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7852312
20 November 2023 ACP Drydock Oversight · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7836741
21 April 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7673203
21 April 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7685566
3 April 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7709931
20 February 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7640981
17 February 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648528
16 September 2022 Annual Inspection · ACP Annual Oversight · Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7560412
31 August 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7548370
5 February 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7391174
25 October 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7340443
8 August 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7282376
1 May 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7195699
28 April 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7186052
23 October 2020 ACP Drydock Oversight · Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7082717
9 October 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7074428
6 August 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139746
24 July 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139750
7 July 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139748
24 June 2020 COI Inspection · Administrative Inspection · Re-Inspection · ACP COI Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6986060
8 April 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6938132
13 December 2019 Administrative Inspection · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6874222
24 October 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6840815
6 August 2019 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6765765
22 October 2018 ACP Drydock Oversight · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6566262
22 August 2018 ACP Drydock Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6521273
26 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6456320
13 May 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6417540
25 January 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6344239
26 October 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6346722
20 September 2017 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6271388
14 August 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6151994
19 April 2017 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6127990
24 January 2017 Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6082069
29 August 2016 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 5986290
16 August 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5976941
28 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5864392

Deficiency record · 56

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 January 2024 Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. The port AFFF monitor is inoperable due to a 5" x 2" rupture in the line. Make permanent repairs to the system to the satisfaction of class.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2024
Resolved 30 January 2024
Resolution: Section of AFFF pipe was removed flange to flange and straight section of pipe with burst section replaced and pressure tested at Propulsion Controls Engineering Bremerton.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2023 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessels port and starboard main propulsion systems failed and vessel lost propulsion while underway. Conduct root cause analysis and perform main propulsion control system groom, provide findings to Sector San Diego.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2023
Resolution: Received class report that def was corrected by replacing cluth pressure regulator air filters.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2023 Resolved
Tank Deck AFFF system suffered the following casualties: -Spool for Monitor One (01) at frame 33, developed a large hole with 200 gal/min escaping the hard piping system. -during test for Zone Two (02), no water flow was coming from the sprinklers. -fire and ballast pump could not be stopped after activation. Liquid cargo operations are restricted until repairs to the AFFF fire monitor and sprinkler system are made to the satisfaction of Class.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2023
Resolution: Cannot conduct cargo liquid transfer operations until def has been rectified. 25MAR23 successful test of system witnessed by RO
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 February 2023 Resolved
A person may not employ or engage an individual, and an individual may not serve in a position in which it is required by law or reguation that the individual hold an MMC endorsed with a national endorsement, as well as a corresponding endorsment for service outside the boundary line. The mariner filling the chief engineer position has an incorrect propulsion type allowance on their STCW endorsement as Chief Engineer and OICEW.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 February 2023
Resolution: Mariner worked with NMC to rectify error on credential.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 February 2023 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Mariner in the postion of bosun/AB-Deck was found with expired national medical certificate.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 11 February 2023
Resolution: Mariner was replaced with another crew member appropriately credentialed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 February 2023 Resolved
The normal equipment of a fast rescue boat shall include a VHF radiocommunication set which is watertight. Due to flooding damage, VHF on port side rescue boat no longer functional. LSA 5/5.1.4.11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 17 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 February 2023 Resolved
Every lifeboat to be launched by fall or falls, except free-fall lifeboat, shall be fitted with a release mechanism complying with the following requirements: the release mechanism shall be so arranged that all hooks are released simultaneously. During inspection, Marine Inspectors found that lifeboat #1 could not release on-load without a significant delay in release of aft and forward release hooks. Additionally, crew appears to regularly practice bypassing the on-load release procedure during operational tests/drills. 74 SOLAS (20) III/34; LSA 4/4.4.7.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2023
Resolution: Witnessed testing of on-load release. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 February 2023 Resolved
During preparation and launching, the survival craft, its launching appliance and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from emergency source of electrical power required by regulation II-1/42 or II-43, as appropriate. Marine Inspector found that all lights that point into water on starboard side, and all but one on port side, for survival craft launching/embarkation/recovery are not operable. 74 SOLAS (97) III/15.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
Resolution: Witnessed operation of the e-lights for the lifesaving embarkation stations.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported to Marine Inspectors that both rescue boats are inoperable due to flooding from rain damage. 74 SOLAS (20) I/11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2023
Resolution: Witnessed testing of both FRBs. Port side boat radio INOP. Wrote up in Def #23.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. International Shore Connection missing from location listed on Fire Control Plan. 74 SOLAS (20) I/11(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 February 2023 Resolved
Any required...fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. Marine Inspector found trouble indication on fire alarm panel and found several fire detectors that were disconnected and hanging from their mounts. 74 SOLAS (81 Amended) II-2/12.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2023
Resolution: Crew replaced detectors and trouble alarm resolved. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Watertight door indicator in ECR for WTD at Frame 102 inoperable: doesn’t indicate if door is open/closed. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: Tested door after crew replaced light bulb. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 6 February 2023 Resolved
Structural members...and all other fittings used in connection with launching equipment shall be designed with not less than a minimum safety factor on the basis of the maximum working load...a minimum safety factor of 4.5 shall be applied to all davit and winch structural members. Port side rescue boat davit designed as a tilting davit, however due to long term deterioration and painting over of components it has been seized in place. Vessel to secure all pivot points by mechanical fastening/welding to ensure boat does not accidentally shift and prove proper launching utilizing only davit. 74 SOLAS (97) III/ 48.1.8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: Welds put on davit to prevent from tilting. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Life ring located at starboard rescue boat was found missing. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: Life ring and bracket replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2023 Resolved
Firefighter’s outfit. Personal equipment shall consist of electrical safety lamp of an approved type...Electric safety lamp on tankers and those intended to be used in hazardous areas shall be of an explosion proof type and axe with a handle provided with high-voltage insulation. During fire drill, firefighters were found to be without radios and axes. SOLAS (20) II-2/10.1.1 FSS Code 3.2.1.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 13 February 2023
Resolution: 10FEB: Radios provided, axes still outstanding.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2023 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Wiring for general alarm at aft port side of midships unrep station found to be routed through a sharp edged rat hole and spliced outside of junction box. Make repairs to include proper weather-tight cable transit and make wiring connections inside junction box. 74 SOLAS (04) II-1/45.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 10 February 2023
Resolution: New cable transit and now spliced inside junction box. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2023 Resolved
Where necessary, relatively tight compartments such as refrigeration spaces, paint lockers, etc., shall be provided with suitable means for relieving excessive pressure accumulating within the compartment when the carbon dioxide is injected. Door to forward cargo store room installed backwards. Does not open outwards from fixed gas system. U.S. Supplement ABS 2003
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 13 February 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 February 2023 Resolved
A general emergency alarm system complying with requirements of regulation 50 shall be provided. General alarm bell on starboard side aft of house found disconnected and missing. 74 SOLAS (97) III/6.4.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 10 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2023 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. A/C unit that services ammunition locker base is wasted. Crew could not determine if unit worked or not. Temperatures in ammunition locker showed evidence of exceeding 100 degrees F. Unit is being held up with lashings. Repair base and install A/C unit to satisfaction of ABS. 74 SOLAS (04) II-1/40.1.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 10 February 2023
Resolution: A/C unit removed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 6 February 2023 Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. The height of the bulwarks or guard rails shall be at least 1m from the deck. Marine Inspectors found damage to rail on aft corner, starboard side, of forecastle. Crew stated that this was damaged from a crane operation at the shipyard. Additionally, damage was done to a blue light on rail just aft of Forecastle. Make repairs to satisfaction of ABS. ICLL (88) II/25(2)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 17 February 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector found multiple kick pipes for deck equipment wasted on the 01 deck. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2023
Resolved 17 February 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 6 February 2023 Resolved
Each nonmetallic transfer hose must: Have no unrepaired loose covers, kinks, bulges, soft spots or any other defect which would permit the discharge of oil or hazardous material through the hose material, and no gouges, cuts or slashes that penetrate the first layer of hose reinforcement as defined in § 156.120(i)...Have no external deterioration and, to the extent internal inspection is possible with both ends of the hose open, no internal deterioration... Hoses not meeting the requirements of paragraph (c)(1)(i) of this section may be acceptable after a static liquid pressure test is successfully completed in the presence of the COTP. The test medium is not required to be water. Marine inspectors found that virtually all cargo transfer hoses showed signed of external deterioration. Hoses shall be subject to additional inspection and testing prior to being returned to service. 33 CFR 156.170
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 February 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 6 February 2023 Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have on board an emergency means to enable the person in charge of a transfer operation to a facility, to another vessel, or within the vessel to stop the flow of oil or hazardous material. Emergency shutdowns throughout the vessel were found to have unreadable signage, exposed wiring, or broken covers. 33 CFR 155.780(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2023
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 6 February 2023 Resolved
A ship of 300 gross tons or more constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow, and fill pipe. Marine Inspector found several containment plugs missing. 33 CFR 155.320(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2023
Resolution: Containment plugs replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. HP Pressure tank system on the cargo deck found with multiple painted over and zip tied pressure relieving devices while in service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 February 2023
Resolution: Paint removed. Plates visible. Some data not legible. Crew plans to replace plates.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2022 Resolved
Annual Inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Due to vessel conducting repairs vessel has gone past 3 month limit. Schedule a date to renew prior to movement of vessel.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 February 2023
Resolution: Vessel completed ACP Annual Inspection.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 31 August 2022 Resolved
Un approved modification was made in way of the transverse expansion joint on the 01 level at frame 56.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 February 2023
Resolution: Unapproved modification was removed satisfactorially.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 January 2022 Resolved
A self-contained emergency source of electrical power shall be provided. Ship crew reported that EDG shut down after over-speeding, in addition that local and switchboard stop switch are not operating as intended. 74 SOLAS (2004) II-I REG 43.1.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2021 Resolved
A self-contained emergency source of electrical power shall be provided. EDG is inoperable due to small fire shall be provided. EDG is inoperable due to small fire IWO of generator exhaust manifold. Conduct root causal analysis, Repair to OEM specifications, and to the satisfaction of RO. 74 SOLAS (2004) II-I REG 43.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 December 2021 Resolved
Means shall be provided to close all openings which may admit air to or allow gas to escape from a protected space. 06-92-1 Engine room air supply damper louvers are inoperable. 74 SOLAS (1997) II-2 Reg 5.1.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 January 2022
Resolution: ABS Surveyor [name withheld], witness sat repair and operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 December 2021 Resolved
Every ship shall be provided with fire pumps, fire mains, hydrants, and hoses complying with applicable requirements of this regulation. During operational test Fire main expansion joint ruptured IWO main deck P/S ZONE 3.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 January 2022
Resolution: ABS Surveyor [name withheld], witness sat repair and operation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 December 2021 Resolved
The ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. INOP bilge alarm IWO aft P/S pump room. 74 SOLAS (2020)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 January 2022
Resolution: ABS Surveyor [name withheld], witness sat repair and operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 May 2021 Resolved
Faulty current transformer for #4 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 July 2020 Resolved
Title 46, CFR, Part 113.25-12 (b): Each general emergency alarm signal must be an electronically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. Repair and prove operation of the following general alarms: 1 x general alarm in way of SWB P4 Tank, port side on tank top, 2 x general alarms in way of fire station no. 61, port side, 1 x general alarm in way of fire station no. 63, port side, 1 x general alarm with inoperable bell in aft truck tunnel, 1 x general alarm with inoperable rotating light in aft truck tunnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 July 2020 Resolved
74 SOLAS (2014) Chapter III, Regulation 20.10: Containers, brackets, racks and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with recommendations of the Organization, indication the devices stowed in that location for that purpose. Replace missing symbols for ring buoys with attached float light at the following locations: 2 x on port side tank top and 1 x focsle near intake no. 02-12-2 Supply vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2020 Resolved
74 SOLAS (2014) Chapter II-2, Regulation 14.2.2.1: Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner due regard to ensuring the reliability of fire-fighting systems and appliances. Portable fire extinguishers throughout house and work spaces were inspected with overdue annual service tags as of June 2020. Per vessel’s Captain, 3rd party service technician is scheduled to attend the vessel in Guam before end of July to complete inspection of vessel’s firefighting detection/suppression and portable extinguishers. Submit copy of inspection/service report to Sector Guam.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 2 July 2020 Resolved
Oil filtering equipment referred to paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. MARPOL Annex 1/14: In addition, it shall be provided with alarm arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 parts per million. Vessel was unable to demonstrate that the oily water separator and oil content meter is operating as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 1 July 2020 Resolved
74 SOLAS (2014) Chapter 1, Regulation 11: The condition of the ship and its equipment shall be maintained to confirm with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Repair sound power powered phones at the following locations and prove operation: Focsle and in Motor Rooms 1, 2 and 3.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 July 2020 Resolved
74 SOLAS (2014) Chapter III, Regulation 20: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Repair and prove operation of Rescue Boat compass and nav horn.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2020 Resolved
74 SOLAS (2014) Chapter II-2, Regulation 14.2.2.1: Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner due regard to ensuring the reliability of fire-fighting systems and appliances. CO2 flooding system for Motor Rooms 1, 2 and 3 displays incorrect time delay of 20 seconds for exiting spaces. Time delay units are marked with minimum time delay of 60 seconds. Update placards with correct time delays for motor rooms 1, 2 and 3.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 1 July 2020 Resolved
ICLL (1966) Annex I, Regulation 8: The ring, lines, letters shall be painted in white or yellow on a dargk ground or in black on a light ground…The marks shall be plainly visible. Paint in contrasting color starboard deck line per vessel's current International Load Line Certificate to the satisfaction of Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 July 2020 Resolved
74 SOLAS (2014) Chapter I, Regulation 11: The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service they are intended. Repair COJP low suction wheel valve with vice-grip on gland bolt to as original.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2020 Resolved
74 SOLAS(14) II-1/54.4.1: The control system shall be such that the services needed for the operation of the main propulsion machinery and its auxiliaries are ensured through the necessary automatic arrangements. One of the three main engine's salt water stand-by cooling pump could not auto start and change over upon loss of pressure from the primary cooling pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 October 2018 Resolved
Ventilator openings and air pipes shall be provided with weather tight closing appliances. Vessel was found with multiple ventilator closures on main deck and 01 deck missing hardware, painted over, corroded or otherwise incapable of being closed. ILLC Reg 19.4 and Reg 20.
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: All closures were re-insepcted and found to be operable and in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 23 October 2018 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The Port Side rescue boat davit experienced hydraulic hose failure during testing rendering davit INOP and rescue boat unable to be launched or recovered. Solas 74 (14 amend) III/20.1
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Vessel crew found loose fittings and properly secured, tested and demonstrated proper operation to the satisfaction of the attending CG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2018 Resolved
The machinery, associated piping, and fittings shall be so installed and protected to reduce to a minimum any danger to persons on board. The Emergency Generator Set prime mover was found leaking diesel fuel from fuel hose fitting and filter housing during operational testing. SOLAS 74 (83 amend) II-2 Reg 26.1
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: New o-ring and gasket installed, tested and verified satisfactory by attending CG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 October 2018 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The #2 lifeboat sliding door was found missing hardware and not able to be properly secured closed. Solas 74 (14 amend) III/20.1
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Vessel crew replaced missing hardware as required and verified by attending CG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chaffing and other damage. Overhead wiring adjacent to emergency generator access hatch was found unsupported due to broken clip on framing. Solas 74 (83 amend) II-2/45/5.5
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 23 October 2018
Resolution: New wire support installed as required and verified by CG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018 Resolved
After any survey of the ship has been completed, no change shall be made in the structural integrity, machinery, or equipment covered by the survey without the sanction of the Administration. Addition of cooling fan in steering room needs approved and permanently installed to include proper utilization of junction boxes and wire supports as appropriate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2018
Resolved 14 November 2018
Resolution: Fan wiring properly installed as required.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 October 2018 Resolved
Provide proper batteries for all onboard water lights. Water lights on bridge wings have a max weight requirement of 1.49 lbs. Installed batteries have weight of 1.95 lbs. None of the water light batteries throughout the vessel are listed on the manufactures recommended battery list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2018
Resolved 14 November 2018
Resolution: ABS accepted CG835V, issued finding number 1604 to replace batteries as required.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 28 September 2016 Resolved
No lifeboat launching instructions.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 September 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 September 2016 Resolved
Grab lines on 4 Liferings in substandard condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2016
Resolved 28 September 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 28 September 2016 Resolved
Spare extinguishers not properly stowed in foam room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 September 2016
Electrical › Electric Generation Source (service) › Generator Cable
Issued 28 September 2016 Resolved
Number 4 Generator had bad tie to switchboard
Condition: Damaged By Earlier Event
Due 28 October 2016
Resolved 28 September 2016
Resolution: vessel tested generator in presence of ABS surveyor.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 September 2016 Resolved
EBIRBs not registered with NOAA
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 September 2016
Resolution: Master produced email from NOAA acknowledging receipt of registration.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 16 August 2016 Resolved
#SSDG 3 had a alarm light for ground, vessel crew took the generator off line and secured operation until furhter troubleshooting can be done. Request proper repair, and operatinal test.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 February 2018
Resolution: Multiple USCG and class surveys have been carried out with no outstanding remarks concerning this issue.