MAURY USCG vessel records Sign in
← All vessels

LA FAMILY ISLAND EXPRESS

LA FAMILY ISLAND EXPRESS is a 1939 freight ship. The Coast Guard has recorded 11 inspections since 2001, most recently in April 2003, along with 106 deficiencies and 7 operational controls.

Records from 2001 to 2003. Most recent: inspection, 28 April 2003.

Built
1939
Last inspected
28 April 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5241685 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CPB500
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-31358

Inspections, by type

…with no type recorded6
Years with a record 3 calendar years (2001–2003)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it526 - Convention (Subpart B), Gross Ton
299 - Regulatory (Subpart C or D), Gross Ton
221 - Convention (Subpart B), Net Ton
221 - Regulatory (Subpart C or D), Net Ton
493 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

28 April 2003 Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 1816038
7 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1754122
26 February 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1754100
2 January 2003 Deficiency Check · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1725179
28 December 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1723710
10 December 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1721576
10 July 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1643947
5 July 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1641676
26 April 2002 Administrative Inspection · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1609756
25 April 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1609290
3 December 2001 Annual Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 294181

Deficiency record · 106

Lifesaving › Lifejacket/PFD (General)
Issued 2 January 2003 Resolved
Provide SOLAS approved lights for all lifevests onboard. LEGACY COMPONENT DESC: Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 25 February 2003
Resolution: Provided lights.
Communications › Radio Communications
Issued 2 January 2003 Resolved
Provide proof of registration of EPIRB and experation dates for EPIRB and hydrostatic release. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 25 February 2003
Resolution: Proof of registration of EPIRB provided.
Lifesaving › Buoyant Smoke Signals
Issued 2 January 2003 Resolved
Provide self-activating smoke signal for port side bridge wing lifebuoy.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 5 March 2003
Resolution: Smoke signal provided.
Electrical › Lighting (service)
Issued 2 January 2003 Resolved
Provide covers for all lightbulbs throughout the vessel's accomodation and engine spaces. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Accommodation/Occupational Safety › Washroom/Toilet
Issued 2 January 2003 Resolved
Repair the toilet on the main deck port side. Current conditions are unsanitary with the toilet broken and open pipes leading to the sewage tank. LEGACY COMPONENT DESC: Toilet
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Deck/Cargo › Holds/Tanks
Issued 2 January 2003 Resolved
Provide new flame screens for all gooseneck vents on main deck. LEGACY COMPONENT DESC: Flame Arrester
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Properly terminate all loose dead-end wiring in trunk leading down into forepeak. LEGACY COMPONENT DESC: Exposed elctrical hazards
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Electrical › Electric Generation Source (emergency)
Issued 2 January 2003 Resolved
Emergency fuel shutoff for emergency generator is currently inoperable for intended use. Prove proper operation to attending USCG inspector. LEGACY COMPONENT DESC: Fuel shut-down
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 25 February 2003
Resolution: Proper operation proven.
Construction/Loadline › Structures
Issued 2 January 2003 Resolved
Repair wasted holes in superstucture bulkhead on starboard side fwd. LEGACY COMPONENT DESC: Superstructure
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Provide proper storage for oxygen and acetylene cylinders in accordance with CCSSC 3.20. LEGACY COMPONENT DESC: Oxygen & acetylene storage
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 5 March 2003
Resolution: Oxygen and acetylene containers removed.
Fire Fighting › Fire Main
Issued 2 January 2003 Resolved
Permanently repair fire main in engineroom in way of current soft patch located midships forward. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Pollution Prevention/Response › Prevention Equipment
Issued 2 January 2003 Resolved
Permanently repair sewage piping in engineroom in way of current patch located near overhead on port side. LEGACY COMPONENT DESC: Sewage System Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Construction/Loadline › Penetrations
Issued 2 January 2003 Resolved
Properly plug all wire penetrations in forward bulkhead of engineroom leading to paint locker. LEGACY COMPONENT DESC: Gasket
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Properly terminate all dead-end wiring in navigation bridge. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 25 February 2003
Resolution: Dead end wiring properly terminated.
Electrical › Electric Supply System (service)
Issued 2 January 2003 Resolved
Properly wedge batteries in storage box and provide caps for all battery cells. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Electrical › Electrical Distribution System (service)
Issued 2 January 2003 Resolved
Remove extension cord and properly wire outlet for the refrigerator on the upper deck, aft of the masters cabin. LEGACY COMPONENT DESC: Outlet Box
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Construction/Loadline › Structures
Issued 2 January 2003 Resolved
Properly install the air conditioner in the masters cabin. A/C wall unit does not properly fit in the opening in the bulkhead. There is an excessive gap around the unit. LEGACY COMPONENT DESC: Superstructure
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Properly terminate/dead-end wires in the port side store room on the upper deck. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Lifesaving › Lifebuoys
Issued 2 January 2003 Resolved
Replace the waterlight for the port side lifebuoy on the upper deck. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Lifesaving › Inflatable Liferafts
Issued 2 January 2003 Resolved
Provide servicing certificates for both liferafts. LEGACY COMPONENT DESC: Servicing
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Construction/Loadline › Structures
Issued 2 January 2003 Resolved
Properly repair wastage in the stack access just aft of the pilot house on the starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2003
Resolved 13 February 2003
Electrical › Lighting (service)
Issued 2 January 2003 Resolved
Properly wire the deck work lights located on the top of the pilot house. Wiring has inproper splicing.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Electrical › Electric Supply System (service)
Issued 2 January 2003 Resolved
Properly wire the battery charger in the pilot house. Eliminate the portable automotive battery charger and the leads led through the window. LEGACY COMPONENT DESC: Battery Charger
Action required: 705 - Other - as specified
Due 2 January 2003
Resolved 13 February 2003
Electrical › Lighting (service)
Issued 2 January 2003 Resolved
Provide missing globe for the light on the aft port side of the upper deck. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Electrical › Electrical Distribution System (service)
Issued 2 January 2003 Resolved
Properly wire electrical outlet above the stove in the galley. LEGACY COMPONENT DESC: Outlet Box
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 2 January 2003 Resolved
Remove the flexible hose and properly pipe the propane cylinder for the galley. Remove the extraneous pipe that leads to the starboard side main deck. LEGACY COMPONENT DESC: Cooking Fuel
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Deck/Cargo › Holds/Tanks
Issued 2 January 2003 Resolved
Properly repair the forward ballast overflow/vent pipe on the starboard side in way of the 'twen deck in the cargo hold. LEGACY COMPONENT DESC: Ballast Vent Pipe
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Electrical › Electric Supply System (service)
Issued 2 January 2003 Resolved
Properly stow and cover the batteries in the forward part of the engineroom, starboard side. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Engineering › Lubricating Oil Storage/Transfer System
Issued 2 January 2003 Resolved
Remove accessive lube oil from the drip pan below the main engine lube oil tank.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Construction/Loadline › Markings
Issued 2 January 2003 Resolved
Paint the deck line for the loadline in a contrasting color to the hull. LEGACY COMPONENT DESC: Load Line Mark
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Fire Fighting › Combustible Materials
Issued 2 January 2003 Resolved
Provide suitible fixed/portable fire fighting equipment for the paint locker in accordance with the CCSS Code. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Personnel › Manning/Qualifications
Issued 2 January 2003 Resolved
Provide 1 additional licensed engineer or provide suitible propulsion controls in accordance with CCSS Code Chapter 2 Part C. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 5 March 2003
Resolution: Engineer provided.
Construction/Loadline › Structures
Issued 2 January 2003 Resolved
Provide gauging report for the access trunk leading to the emergency generator space on the forecastle. LEGACY COMPONENT DESC: Trunk
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Properly dead-end/terminate wiring in the emergency generator space. Provide covers for junction boxes. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 13 February 2003
Documentation › Certificates/Documents
Issued 2 January 2003 Resolved
Provide surveyors report attesting to the completion of outstanding issues from loadline and dry-dock surveys. LEGACY COMPONENT DESC: Survey Report
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 25 February 2003
Resolution: Report provided.
Operations/Management › Port and Waterways Safety
Issued 2 January 2003 Resolved
Complete a satisfactory annual foreign freight vessel exam. LEGACY COMPONENT DESC: Annual Inspection
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2003
Resolved 5 March 2003
Resolution: AFE completed
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Deck and railing rotting, broken and loose around ladder to aft deck. Make permanent and proper repairs to the satisfaction of attending USCG Marine Inspector. LEGACY COMPONENT DESC: Deck Rail
Due 1 March 2003
Resolved 25 February 2003
Resolution: Properly repaired.
Lifesaving › Launching Appliances
Issued 2 January 2003 Resolved
Hydrostatic release not properly installed and expired. Properly install new releases prior to departing the Port of Miami. LEGACY COMPONENT DESC: Release Mechanism
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Properly installed.
Electrical › Electric Supply System (service)
Issued 2 January 2003 Resolved
Open and used electrical outlet mounted on funnel aft of bridge. Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Cable
Due 1 March 2003
Resolved 25 February 2003
Resolution: Properly repaired.
Electrical › Electric Generation Source (service)
Issued 2 January 2003 Resolved
Electrical switch broken, wasted and not properly wired. Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Switch
Due 1 March 2003
Resolved 25 February 2003
Resolution: Switchboard repaired.
Engineering › Sea-water System (primary cooling)
Issued 2 January 2003 Resolved
Bolts and nut's on sea valves wasted. Clean all sea valves for inspection and replace fasteners as needed. To the satisfaction of class. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Properly repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Improper wiring and missing guard on start to generator . Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Properly repaired.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 January 2003 Resolved
Exhaust cooling fresh water piping on Main Diesel has temporary patches. Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Properly repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Provide caps and or guard to protect against electric stock on wiring to generator. To the satisfaction of class. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 1 March 2003
Resolved 25 February 2003
Resolution: Protection provided.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 January 2003 Resolved
Properly run wire to return fuel pump to the satisfaction of class. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Wire properly ran.
Electrical › Electrical Distribution System (service)
Issued 2 January 2003 Resolved
Electrical switch board in engine room a major hazard to vessel and crew. Remove or properly terminate all dead wires at switchboard and through engine room. In sure all fuse sockets are filled or properly blanked and that all loose, broken or unused fixtures are removed, or properly repaired. LEGACY COMPONENT DESC: Switchboard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Electrical switch board in engine room repaired.
Communications › Alarms/Indicators
Issued 2 January 2003 Resolved
Properly wire and prove operation of general alarm in engine room. To the satisfaction of attending USCG Marine Inspector. LEGACY COMPONENT DESC: General Alarm
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: General alarm rewired.
Engineering › Freshwater System (jacketwater cooling)
Issued 2 January 2003 Resolved
Properly pipe in freshwater return from main engine to expansion tanks in upper level including vent and freshwater fill to the satisfaction of class. LEGACY COMPONENT DESC: Storage Tank
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Properly repaired.
Electrical › Electric Supply System (service)
Issued 2 January 2003 Resolved
Remove or properly terminate all dead end wiring in upper level of engine room to the satisfaction of class. LEGACY COMPONENT DESC: Cable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Dead end wiring repaired.
Electrical › Electric Supply System (service)
Issued 2 January 2003 Resolved
Cable to throttle control not properly spliced or mounted. Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Cable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Cable to throttle properly spliced and mounted.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 2 January 2003 Resolved
Power take of generator has temporary belt on drive. Make permanent and proper repairs and prove proper operations under load (bridge equipment) to the satisfaction of the attending USCG marine inspector .
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Properly repaired.
Documentation › Certificates/Documents
Issued 2 January 2003 Resolved
Provide all documentation required for vessel to the attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2003
Resolution: Documentation provided.
Engineering › Steering Gear System
Issued 2 January 2003 Resolved
Prove proper operation of the main steering gear and associated equipment to the satisfaction of the atteding USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2003
Resolution: Properly operating.
Operations/Management › Drills/Instruction
Issued 2 January 2003 Resolved
Prove proper crew familiarization drills to attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2003
Resolution: Drills conducted satisfactory.
Personnel › Certificates/Documents/Licenses
Issued 2 January 2003 Resolved
Provide valid STCW certificates and/or endorsements for vessel's crew. Transitory certificates that have expired cannot be extended or re-issued in accordance with STCW.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2003
Resolution: Valid certificates provided.
Deck/Cargo › Cargo Stowage
Issued 2 January 2003 Resolved
Remove HAZMAT cargo on the vessel i.e. vehicles, batteries, numerous 5 gallon cans of paint, unmarked drums containing unknown substance, and unmarked cylinders. Vehicles may be offered as non-HAZMAT cargo if they are prepared properly in accordance with 49 CFR and IMDG. LEGACY COMPONENT DESC: Hazardous Material
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2003
Resolution: HAZMAT removed.
Electrical › Electric Generation Source (emergency)
Issued 2 January 2003 Resolved
Make permanent/proper repairs to forward 110-generator/emergency generator. Generator is leaking exhaust heavily.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2003
Resolution: Generator properly repaired.
Lifesaving › Launching Appliances
Issued 2 January 2003 Resolved
Rescue boat davit launch system has improper rigging. Tigging is improperly secured to davit hook and rescue boat (tied via knots). Make permanent/proper repairs to rescue boat davit launch system utilizing proper materials and rigging methods. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2003
Resolution: Properly rigged.
Personnel › Manning/Qualifications
Issued 26 April 2002 Resolved
Man vsl in accordance with minimum safe manning document. Provide a properly licensed Chief Mate, 2 able seamen, 1 oiler and 1 ordinary seaman. LEGACY COMPONENT DESC: Minimum Safe Manning
Due 26 April 2002
Resolved 28 May 2002
Resolution: def corrected
Stability › Incline Test
Issued 26 April 2002 Resolved
Conduct inclined stability test prior to loading cargo.
Due 26 April 2002
Resolved 28 May 2002
Resolution: def corrected
Fire Fighting › Fixed Fire Detection System
Issued 26 April 2002 Resolved
Have flag surveyor attest that the engineroom meets Caribbean Cargo Ship Code section 3.16.7.
Due 26 April 2002
Resolved 16 May 2002
Resolution: Cleared per inspection results of 16MAY02.
System not recorded
Issued 3 December 2001 Resolved
Submit to a full U.S. Coast Guard CCSSC Annual Examination prior to loadingcargo and prior to departure
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Documentation
Issued 3 December 2001 Resolved
Mark loadline hull markings IAW loadline certificate as required by International Loadline regulations
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide valid medical certificates for all crew members as required by ILO 147
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide evidence of drydock in 2001. (paperwork on board indicates last drydock in 1999.)
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Engineering
Issued 3 December 2001 Resolved
Conduct hydrostatic test on air receivers in engine room.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Translate all markings and instructions to language of the crew.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Engineering
Issued 3 December 2001 Resolved
Replace all fuel hoses with approved SAE J1942 hoses with fittings.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Lifesaving
Issued 3 December 2001 Resolved
Mark rescue boat and provide equipment for usage.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Navigation
Issued 3 December 2001 Resolved
Repair electric hydraulic pump for steering.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Navigation
Issued 3 December 2001 Resolved
Make repairs to hydraulic rams to prevent hydraulic fuel leaks and clean all fluids from steering room.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Accommodation/Occupational Safety
Issued 3 December 2001 Resolved
Provide adequate fixture for ligt in steering room.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Construction/Loadline
Issued 3 December 2001 Resolved
Make aft collision bulkhead watertight.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Construction/Loadline
Issued 3 December 2001 Resolved
Provide means of positive closure for all watertight hatches and replace gasket material.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Accommodation/Occupational Safety
Issued 3 December 2001 Resolved
Repair leaks to type III MSD (holding tank)
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Lifesaving
Issued 3 December 2001 Resolved
Repair or replace waterlights on both life rings on stern as required by CCSSC chapter 4.12.2
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Lifesaving
Issued 3 December 2001 Resolved
Properly secure liferafts with proper float-free arrangement as required byCCSSC chapter 4.9.5
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Deck/Cargo
Issued 3 December 2001 Resolved
Provide machinery guards on rotating machinery in main engine room as required by CCSSC chapter 2.12.6
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Electrical
Issued 3 December 2001 Resolved
Provide explosion proof light fixtures on all engine room lights as required by CCSSC chapter 2.32.10
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Construction/Loadline
Issued 3 December 2001 Resolved
Pump out / remove oily water from bilges as required by good marine practices
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Electrical
Issued 3 December 2001 Resolved
Remove plastic tube gauge and replace with tapered glass on fwd generator daytank.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Construction/Loadline
Issued 3 December 2001 Resolved
Provide surveyor's report addressing forward void wastage percent u/s original scantling. Also address bent longitudinals, bulkhead or baffle plates % wastage.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Navigation
Issued 3 December 2001 Resolved
Repair rudder angle indicator.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide operations manual for steering system, all navigational equipment,generators, and provide electrical and engineering diagrams and manuals.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Electrical
Issued 3 December 2001 Resolved
Provide logging for exhaust for generator forward.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Electrical
Issued 3 December 2001 Resolved
Replace all hoses on emergency generators (SAE J1942 with fitings)
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Electrical
Issued 3 December 2001 Resolved
Provide adequate junctin boxes for all electrical connections (wd and aft machinery and generators)
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Unknown
Issued 3 December 2001 Resolved
Perform operational tests of all vessel systems in presence of USCG Marine Inspectors.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide oil transfer procedures IAW 33 CFR 155.750.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Engineering
Issued 3 December 2001 Resolved
Provide standard discharge connection IAW 33 CFR 155.420.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Electrical
Issued 3 December 2001 Resolved
Remove all 220 electrical systems form vessel.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide another licensed engineering officer or fire detection system.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Navigation
Issued 3 December 2001 Resolved
Repair auto pilot system.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Lifesaving
Issued 3 December 2001 Resolved
Provide a rescue boat IAW CCSSC chapter 4.4.3
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Accommodation/Occupational Safety
Issued 3 December 2001 Resolved
Repair leaks to connection pipe for MSD piping system.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide licences IAW Safe Manning certificate issued by Bolivian Governement
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Unknown
Issued 3 December 2001 Resolved
Provide current copy of USCG Light List Publication as required by CCSSC Chapter 6.1.2.16
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Electrical
Issued 3 December 2001 Resolved
Provide non-conductive matting for main switchboard.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide instructions for maintenance and operations for all installations/equipment for lifesaving and firefighting.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Commence conducting and logging of all drills IAW CCSSC 4.17.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide documentation for Loadline survey.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide new stability calculations/ Flag approval based on correct freeboard obtained after loadline survey. (2030 v/s 1868 freeboard)
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Documentation
Issued 3 December 2001 Resolved
Provide CCSS Certificate that accurately reflects equipment on board, condition of vessel and required tests.
Condition: Unknown
Due 4 December 2001
Resolved 4 December 2001
Construction/Loadline › Structures
Issued 3 December 2001 Resolved
Provide Flag report addressing the wooden construction of the wheelhouse. LEGACY COMPONENT DESC: Superstructure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2002
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 3 December 2001 Resolved
Refill all SCBA.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2002
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 3 December 2001 Resolved
Lowering of rescue boat is too slow, demonstrate proper launching and recovery.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2002

Ownership record