← All vessels
MEDUSA SPAR
MEDUSA SPAR is a 2003 industrial vessel. The Coast Guard has recorded 35 inspections since 2001, most recently in March 2025, along with 22 deficiencies and 1 operational control.
Records from 2001 to 2025. Most recent: inspection, 7 March 2025.
- Built
- 2003
- Last inspected
- 7 March 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 22 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WPVX346
31362
Flag
UNITED STATES
—
Maury page id
psix-31362
Inspections, by type
…with no type recorded1
Years with a record
22 calendar years (2001–2025)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 35
7 March 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8110215
2 January 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8057043
15 August 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7989322
29 June 2023
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7727395
20 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482239
31 May 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7498662
17 June 2021
Administrative Inspection · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7289346
27 November 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7102531
21 November 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6848893
16 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6685635
2 August 2018
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6455091
25 April 2017
Annual Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6132605
2 March 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6097740
15 June 2016
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5977161
5 October 2015
Annual Inspection · Internal Structural Exam
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5736312
8 August 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4948385
5 August 2014
COI Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4873089
5 January 2012
Special
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4219917
22 September 2011
In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4181220
14 September 2010
Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3884772
18 March 2010
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3698891
10 February 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3678081
27 June 2008
COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3249508
11 September 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3055442
8 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2852274
5 July 2006
In-Service Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2702502
23 November 2005
Re-Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2540092
31 March 2005
Special
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2325064
13 December 2004
In-Service Inspection · Re-Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2258915
5 October 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2214015
17 December 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1965862
21 October 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1933812
16 June 2003
Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1844660
7 September 2001
Administrative Inspection · Construction Oversight
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1866268
6 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1067393
Deficiency record · 22
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 2 January 2025
Resolved
Each rescue boat must be capable of being launched with the unit anchored or bearing on the bottom in a current of up to 5 knots. Each rescue boat launching arrangement must permit the rescue boat to be launched in the shortest possible time. It was reported to the USCG by Murphy Oil Corp that the 1100 crane on board Medusa Spar was observed by third party maintenance to have a cracked flex plate/drive plate rendering it out of service. This crane is intended for launching the Fast Rescue Boat and there are no other cranes in service. Facility has contracted a standby vessel to serve the purpose of the fast rescue craft in any case of a man overboard. Standby vessel shall remain with the facility until the crane is repaired and restored to its satisfactory working condition.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 31 May 2022
Resolved
Emergency drills shall be conducted by the person in charge (PIC). The drills shall be conducted as if an actual emergency existed. At least once a year, all elements of the Emergency Evacuation Plan (EEP) must be exercised. Facility personnel have not exercised the lowering of the lifeboats in the last year. (33 CFR 146.125).
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 May 2022
Resolved
The emergency equipment provided, regardless of whether or not required, shall be maintained in good condition at all times. Rescue boat found with inflatable collar in disrepair – missing reflective tape, broken grab lines, degraded condition. (33 CFR 146.15).
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 May 2022
Resolved
The emergency equipment provided, regardless of whether or not required, shall be maintained in good condition at all times. Murphy’s Medusa lifeboat weekly maintenance checklists require weekly lowering and recovery of both lifeboats. Records and statements from Murphy’s Medusa
STS indicate boats are not lowered at weekly intervals. (33 CFR 146.15).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2019
Resolved
Emergency equipment provided, regardless of whether or not required by 33 CFR subchapter N, shall be maintained in good condition at all times. Fire stations and hose reels were found inoperable during inspections.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 21 November 2019
Resolved
Life saving appliances issues were found as follows: Lifeboats have at least 1 each air bottle below minimum pressure. Life saving maintenance program is not at a minimum meeint the manufacturer's instructions for maintencance for lifeboats weekly, monthly, and semi-annual for releasing gear, monthly, weekly, and quarterly maintenance is not as per manufacturer's recommendation.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 21 November 2019
Resolved
2008 approval letter requires twice in 5 years ISIP inspections to resume 18 August 2019. Submit matrix change to resume twice in 5 years ISIP Inspection cycle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2019
Resolved
Provide SOLAR report upon completion of repairs to both turbine generators to ensure proper operation.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 6 October 2015
Resolved
When lifeboat engine was started, exhaust fumes from the engine were leaking through a hole in the exhaust pipe. A temporary patch was installed and tested. No exhaust was detected after repairs were made. Make permanent repairs to exhaust pipe.
Lifesaving › Lifeboat › Fire Protection (general)
Issued 6 October 2015
Resolved
Lifeboat's internal air pressure relief valve was seized and did not operate correctly. Additionally the vent window aft door would not seal to allow pressure to build up. Repair to original condition. Relief valve was repaired prior to departure.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 6 October 2015
Resolved
A large amount of water was leaking into compartment through a seatbelt bolt hole. Water seemed to be isolated behind the one bolt hole, other bolts were checked with negative results. When lifeboat was hung on lifeboat hooks, the lifeboat did not lean in the direction of the leak nor was damage apparent on hull. Lifeboat must be examined by a third party to ensure the extent of water damage.
Lifesaving › Lifeboat › Seating
Issued 6 October 2015
Resolved
The coxswain's seat at the support on both sides was cracked and needs repair. Repair to original
Lifesaving › Lifeboat › Rigid Cover
Issued 6 October 2015
Resolved
Cover on floor in fwd area of lifeboat was broken. Replace to original.
Lifesaving › Lifeboat › Hatches
Issued 6 October 2015
Resolved
The aft door, when closed did not seal properly. Adjust/repair door to original condition.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 October 2015
Resolved
The maintenence/stop valve on E-gen CO2 system did not appear to be in correct posisition for system to operate. The valve was not labled and facility personnel could not tell what posistion it should be in. Ensure valve is operating correctly, is labled and personnel are trained in system.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 6 October 2015
Resolved
Two of the fire extinguishers in service showed low pressure on guage on must be taken out of service and replaced.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Quantity of Foam-Forming Liquid
Issued 6 October 2015
Resolved
According to foam analysis, foam in P06 and P07 was bad. Facility had no documentation showing foam was replaced. Replace foam in the fire stations or provide documentation foam was replaced.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 5 October 2015
Resolved
Several control valves throughout facility were difficult to operate and valve handles were severely corroded. Repair/renew valves to original condition.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 5 August 2014
Resolved
To meet the requirements 46 CFR 107.231 each crane must meet the following rated load tests at both the maximum and minimum boom angles ususally employed in material transfers over the side of the unit. ABS completed rated load test at a single angle pull not at both the maximum and minimum boom angles. Provide documentation attesting to legitimacy of single pull test. -46 CFR 107.260(a)
Electrical › Electric Generation Source (service) › Switch
Issued 5 August 2014
Resolved
In addition to the emergency power sources required under part 112 of this chapter, each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sets. Vessel had an inoperable gas turbine generator from a lube oil level switch that wouldnt allow the turbine to start. Provide plan of action in the event of failure of one turbine and provide report.
Lifesaving › Lifeboat › Hull
Issued 22 September 2011
Resolved
During the testing of the limit switches on lifeboat "B" the contacts welded together causing the lifeboat to be pulled up into the davit. Lifeboat received fiberglass damage to roof, stern hook was pulled .25" out of boat, forward hook was bent, and falls were stretched.
Construction/Loadline › Structures › Deck Plating
Issued 13 December 2004
Resolved
North Side of Drilling deck, Production Deck and Cellar Deck, NE corner of Main Quarter 2nd & 3rd deck damaged when workover rig was knocked over during hurricane IVAN, September 2004.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.