MAURY USCG vessel records Sign in
← All vessels

CARIBE TIDE

CARIBE TIDE is a 1988 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1988, most recently in May 2026, along with 276 deficiencies, 1 operational control and 1 casualty investigation in 2001.

Records from 1988 to 2026. Most recent: inspection, 26 May 2026.

Built
1988
Last inspected
26 May 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE6963
313793
Flag
UNITED STATES
368130000
Maury page id
psix-313793

Inspections, by type

…with no type recorded14
Years with a record 34 calendar years (1988–2026)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)80.6 ft × 24.1 ft × 9.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEQUITABLE/HALTER MARINE · NEW ORLEANS, LA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST JOHN, VI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE6963MMSI 368130000 · active · compulsorily equipped · granted 21 November 2018, expires 9 December 2028
WUU5254MMSI 368130000 · expired · compulsorily equipped · granted 6 October 1998, cancelled 4 December 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ROANOKE Passenger Barge (Inspected) · MISLE 105775 · 9 March 2001 · activity 46837

Inspection history · 94

26 May 2026 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8380700
12 September 2022 Examination of Repairs · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7556772
29 June 2021 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7240112
6 August 2020 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7026293
27 May 2020 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6966536
6 August 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6785185
22 June 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6451455
27 April 2018 Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6399066
28 March 2018 Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6380101
1 October 2017 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6280912
1 October 2017 In-Service Inspection
Physical examination · Marine Safety Center (MSC) · Activity 6286112
14 June 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6173284
29 June 2016 Deficiency Check · MTSA Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5917516
14 March 2016 Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5832544
7 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5828449
16 June 2014 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4892481
6 February 2012 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4239671
2 August 2011 Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4118405
13 October 2010 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3872020
7 January 2010 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3660095
15 July 2009 Hull Examination · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3534003
3 December 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3373104
28 July 2008 COI Inspection · Deficiency Check · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3281978
21 July 2008 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3274641
18 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3274654
18 March 2008 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3166940
18 October 2007 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3082409
12 September 2007 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3056009
19 March 2007 MTSA/ISPS Verification · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2891094
29 August 2006 Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2762824
24 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2723545
29 June 2006 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2695026
10 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2645455
13 April 2006 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2623967
11 April 2006 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2622168
2 December 2005 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2544586
12 October 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2512791
11 August 2004 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2162765
28 June 2004 MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2101342
13 February 2004 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2009376
14 April 2003 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1773241
14 April 2003 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2097882
19 August 2002 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1740856
17 April 2002 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1605512
21 August 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1447169
25 June 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1071854
24 April 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417300
9 March 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 46837
6 June 2000 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1404999
15 February 2000 Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1381833
22 April 1999 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 212127
23 March 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1045720
3 February 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1454632
15 January 1999 MARPOL Annex V Examination · Drydock Extension · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375624
8 July 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1129390
15 December 1997 Examination of Repairs · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447750
24 June 1997 Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1378088
22 November 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1095800
20 September 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1137889
2 August 1996 Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367873
11 June 1996 Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367787
17 August 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1186750
3 August 1995 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1385510
22 July 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1189861
12 June 1995 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439628
5 August 1994 COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1457191
26 May 1994 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354698
19 October 1993 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 502950
16 September 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1146754
12 August 1993 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1425342
7 June 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 829773
1 April 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 835264
25 November 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1362664
31 August 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1269002
14 August 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1246674
4 June 1992 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1249332
27 September 1991 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1250895
16 August 1991 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1246051
2 July 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 933201
18 June 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 887349
11 March 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1215602
17 August 1990 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 927754
27 June 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1215668
18 June 1990 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 918911
19 January 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1237141
22 August 1989 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1205361
16 June 1989 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1342882
23 April 1989 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203835
9 December 1988 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 896283
30 September 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1235559
14 September 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1350615
1 September 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1040822
9 August 1988 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031086
3 March 1988 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336550

Deficiency record · 276

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 August 2020 Resolved
Vessels of 26' length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. The bilge system on the vessel is not working and did not provide suction out of the storage compartment. Vessel crew appeared unfamiliar with the bilge system and the controls for the system were not labeled properly to allow for the proper operation of the system. Prove proper operation of the installed bilge suction system from all compartments to the satisfaction of the CG prior to carrying passengers and properly label system controls and components to allow for the proper operation of the bilge system. 46 CFR 182.25-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2020
Resolution: Bilge system was labeled and tested to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 August 2020 Resolved
The minimum capacity of the power fire pump shall be 50gpm at a pressure of not less than 60psi at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Vessel's fire pump did not provide the required pressure and it only showed 30psi at the pump outlet. Prove proper operation of the power fire pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2020
Resolution: Fire system tested to the satisfaction of the Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 August 2020 Resolved
Lifelines on the upper deck have wasted fittings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2020
Resolution: Lifelines replaced on the upper deck. Replacement inspected to the satisfaction of the Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 August 2020 Resolved
Gasket on watertight hatch leading to the lazarette needs replacing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2020
Resolution: Watertight hatch gasket replaced to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2020 Resolved
Provide SOLAS reflective tape for lifering forward of the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2020
Resolution: SOLAS reflective tape applied to the forward life ring to the satisfaction of the Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 6 August 2020 Resolved
Prove proper operation of door knobs on both passenger doors on the aft part of the passenger compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2020
Resolution: Door knobs replaced on both aft passenger doors to the satisfaction of the Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 August 2020 Resolved
Vessel Security Plan approval letter is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2020
Resolution: Security Plan revised and submitted to MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2018 Resolved
Bilge manifold lines missing check or stop-check valves. Install check or stop-check valves on each line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2018
Resolved 21 August 2018
Resolution: Vessel installed check valves in all bilge pick-up lines.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2018 Resolved
Provide drug testing program records showing compliance to include contract, covered crew list, and designated employee representative designation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Vessel switched to new consortium and provided program documentation.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 June 2018 Resolved
Show proper operation of both fire pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Vessel demonstrated pump operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 June 2018 Resolved
Demonstrate proper operation of installed bilge piping system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Vessel demonstrated operation of bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2018 Resolved
Remove excess combustible materials below passenger staircase in main cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Vessel removed material.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 22 June 2018 Resolved
Provide current waste management plan and placard.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 26 June 2018
Resolution: Vessel drafted new plan and posted accurate placard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2018 Resolved
Secure bridge battery box.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 26 June 2018
Resolution: Vessel secured battery box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2018 Resolved
Provide battery box cover in generator space.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 26 June 2018
Resolution: Cover provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2018 Resolved
Provide distribution panel and overcurrent protection for wires coming from generator space battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2018
Resolved 12 July 2018
Resolution: Vessel installed panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2018 Resolved
Provide retro-reflective tape for forward ring buoy.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 26 June 2018
Resolution: Retro tape provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2018 Resolved
Provide fire spanner wrenches for all fire stations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2018
Resolved 21 August 2018
Resolution: Vessel provided spanner wrenches.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 June 2018 Resolved
Provide closure pin for EPIRB housing.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 12 July 2018
Resolution: Vessel provided pin.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 June 2018 Resolved
Mount and provide crew training on fuel oil shutoff handles.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 26 June 2018
Resolution: Handle mounted and crew trained on usage.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 June 2018 Resolved
Show proper operation of machinery space ventilation closures in all sea conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 21 August 2018
Resolution: Vessel reconfigured ventilation closures to be operable from top deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2018 Resolved
Stray dead end wires below port inboard main diesel engine micro controllers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2018
Resolved 26 June 2018
Resolution: Dead end wires removed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 June 2018 Resolved
Provide light list.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 26 June 2018
Resolution: Light list provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2018 Resolved
Provide brackets for all fire extinguishers.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 26 June 2018
Resolution: Extra fire extinguishers removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2018 Resolved
Vessel capacity is reduced as follows: Total persons on allowed: 246 Total passengers allowed: 242 Maximum passengers on upper deck: 99 This CG-835 is due to weight changes incurred when vessel replaced life floats with Inflatable Buoyant Apparatuses. This CG-835 is to be kept on board the vessel as an attachment to the COI until cleared.
Action required: 705 - Other - as specified
Resolved 11 July 2018
Resolution: MSC provided revised stability letter.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 June 2017 Resolved
High bilge alarms failed to function on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2017
Resolution: Vessel showed working alarms.
Engineering › Fuel Oil Service System › Valve, Control
Issued 14 June 2017 Resolved
Crew were impeded from turning the valves due to the handle being too long and coming into contact with passenger seating
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 30 June 2017
Resolution: Vessel provided wrenches designed for valve arrangement.
Construction/Loadline › Hull › Stiffener
Issued 14 June 2017 Resolved
Found 7 cracks in aluminum stiffeners and frames in the forepeak void space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 30 June 2017
Resolution: CG MI observed repairs.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 June 2017 Resolved
Whistles missing on numerous lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 30 June 2017
Resolution: Vessel provided whistles.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 June 2016 Resolved
Replace leaking starboard outboard exhaust water cooling water pipe prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2016
Resolved 13 July 2016
Resolution: Corrected and verified by attending MI.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 June 2016 Resolved
Correct PFD storage location markings with accurate numbers.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 13 July 2016
Resolution: Corrected and verified by attending MI.
Communications › Radio Communications › EPIRB
Issued 29 June 2016 Resolved
Update EPIRB registration with current call sign.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 13 July 2016
Resolution: Corrected and verified by attending MI.
Electrical › Electric Generation Source (service) › Generator
Issued 29 June 2016 Resolved
Clean oily windings and determine/repair source of oil. Extended due date from 13JUL2016 to 20JUL2016.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 8 August 2016
Resolution: Vessel cleaned windings.
Communications › Public Address System › Loudspeaker
Issued 29 June 2016 Resolved
Show proper operation of Public Address system.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 13 July 2016
Resolution: Corrected and verified by attending MI.
Electrical › Electric Generation Source (service) › Generator
Issued 29 June 2016 Resolved
Replace soiled exhaust lagging and determine/repair exhaust leak on port generator.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 13 July 2016
Resolution: Corrected and verified by attending MI.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 14 March 2016 Resolved
Prove operation of generator through hull valve at side shell.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Through hull valve operated satisfactoriy
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2016 Resolved
Make repairs to cracked and holed starboard side inboard engine exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 March 2016 Resolved
Provide spacing specification for starboard shaft and strut; propeller hub is spaced within a 1/4 inch of the strut.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Resolution: Propeller was moved to the starboard inboard shaft.
Construction/Loadline › Hull › Hull Plating
Issued 14 March 2016 Resolved
Crop and renew wasted and holed hull plating as identified on port side transum.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Resolution: New plating installed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 March 2016 Resolved
Remove flex hose and make piping available for inspection in port side forward steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Flex hose removed and piping renewed.
Construction/Loadline › Penetrations › Valve Flange
Issued 14 March 2016 Resolved
Replace non-operational check valve in piping, port side steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Check valve replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2016 Resolved
Make hull plating under starboard generator raw water intake available for inspection and remove strainer on bottom plating. Crop and renew wasted hull plating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Resolution: Plating replaced.
Stability › Watertight Integrity › General
Issued 14 March 2016 Resolved
Replace missing pipe cap starboard outboard main deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Pipe cap replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2016 Resolved
Crop and renew cracked exhaust piping port side outboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Engineering › Fuel Oil Service System › Valve
Issued 14 March 2016 Resolved
Prove operation of starboard fuel tank valve in engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Fuel tank shutoff calves tested satisfactorily.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 March 2016 Resolved
Replace missing guards on lighting in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: All lighting covers present during inspection.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 6 February 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 29 February 2012
Resolved 22 February 2013
Documentation › Certificates/Documents › FCC SSL
Issued 6 February 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 29 February 2012
Resolved 22 February 2013
Documentation › Certificates/Documents › Stability Letter
Issued 6 February 2012 Resolved
Provide and install Stability Addendum to vessels current Stability Letter on board vessel.
Action required: 705 - Other - as specified
Due 7 February 2012
Resolved 22 February 2013
Stability › Intact Righting Energy › General
Issued 6 February 2012 Resolved
Modify available passenger seating on upper deck to one-hundred-three (103) maximum as per Stability Letter Addendum dated 01DEC2011. In addition, update maximum persons allowed marking(s) to reflect same.
Action required: 705 - Other - as specified
Due 10 February 2012
Resolved 22 February 2013
Lifesaving › Lifefloat › Painter
Issued 13 October 2010 Resolved
REPAIR PAINTER FOR BOYANT APPARATUS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 October 2010 Resolved
PROVIDE WIRE SPLINT FOR FIRST AID KIT.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 October 2010 Resolved
PROVIDE ALCOHOL TESTING DEVICES ON BOARD.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 13 October 2010 Resolved
PROVIDE WRITTEN DRUG POLICY
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Engineering › Bilge Water Management System › Piping
Issued 13 October 2010 Resolved
CLEAN EXESSIVE OIL UNDER STBD. GENERATOR BILGE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Engineering › Bilge Water Management System › Valve
Issued 13 October 2010 Resolved
PROVIDE POSITIVE ACTION VALVE FOR STBD. RUDDER.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 October 2010 Resolved
PROVIDE STBD. GEN SET WITH GUARD FOR EXPOSED HAZARD
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Stability › Watertight Integrity › General
Issued 13 October 2010 Resolved
MAKE ENGINE ROOM WATERTIGHT.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Engineering › Fuel Oil Service System › Valve
Issued 13 October 2010 Resolved
PROVIDE SUPPORT FOR REACH ROD FOR EMERGENCY FUEL SHUT OFF.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Engineering › Bilge Water Management System › Piping
Issued 13 October 2010 Resolved
PROVIDE POSITIVE SHUT OFF VALVE FOR LAZARETTE BILGE.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Fire Fighting › Fire Hoses › Length
Issued 13 October 2010 Resolved
100' hoses need to be reduced to 50' hoses.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 October 2010 Resolved
Provide rail coarsings for stbd. side upper deck wire mesh.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 16 November 2010
Construction/Loadline › Hull › Hull Plating
Issued 15 July 2009 Resolved
Crop and insert port bow hull plate and transverse stiffener, as shown, in way of damaged hull plating found with temporary patch. NDT shall be conducted upon completion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2009
Resolved 21 July 2009
Construction/Loadline › Hull › Stiffener
Issued 15 July 2009 Resolved
Grind and weld fractured weld located at hull plate stiffener and transverse web frame in forepeak, port side. Marked as 1A.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2009
Resolved 21 July 2009
Construction/Loadline › Hull › Stiffener
Issued 15 July 2009 Resolved
Grind and weld fractured welds located at hull plate stiffeners and aft bulkhead in port fuel oil storage void. Marked as # 2, 3, 4, 5 & 6.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2009
Resolved 21 July 2009
Construction/Loadline › Hull › Stiffener
Issued 15 July 2009 Resolved
Grind and weld fractured welds located at hull plate stiffeners and aft bulkhead in stbd fuel oil storage void. Marked as # 7 & 8.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2009
Resolved 21 July 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 July 2009 Resolved
Grind, drill stop and weld fractured bulkhead plating located immediately above outboard hull plate stiffener in stbd fuel oil storage void. Marked as # 9. NDT shall be conducted upon completion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2009
Resolved 21 July 2009
Construction/Loadline › Hull › Stiffener
Issued 15 July 2009 Resolved
Grind and weld fractured weld located at hull plate stiffener and fwd bulkhead in storage room, stbd outboard side, in vicinity of repair marked #9 (opposite side). Marked as # 10.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2009
Resolved 21 July 2009
Construction/Loadline › Structures › Scuttle
Issued 15 July 2009 Resolved
Paint all flush deck scuttle tops RED for all designated emergency escapes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2009
Resolved 29 July 2009
Stability › Unintentional Flooding › General
Issued 15 July 2009 Resolved
Upon completion of all work in forepeak and prior to closing hatch, remove all debris from bilges and ensure drain holes (rat holes) within the transverse frames at keel are free and clear.
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 21 July 2009
Electrical › Electrical Distribution System (service) › Switch
Issued 15 July 2009 Resolved
Remove or relocate breaker switch connected in way of port battery in steering gear/generator compartment.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 29 July 2009
Engineering › Bilge Water Management System › Hose
Issued 15 July 2009 Resolved
Install an additional hose clamp onto the discharge hose for the electric bilge pump in the steering gear/generator compartment.
Action required: 705 - Other - as specified
Resolved 29 July 2009
Engineering › Steering Gear System › Valve
Issued 15 July 2009 Resolved
Renew valve handle in way of drain hose for starboard rudder trunk.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 29 July 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 July 2009 Resolved
Ensure that each end of all coolant water supply hoses to both generators has been secured by two hose clamps.
Action required: 705 - Other - as specified
Resolved 29 July 2009
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 15 July 2009 Resolved
Renew missing lagging in way of port generator exhaust system.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 29 July 2009
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 28 July 2008 Resolved
Repack port shaft gland
Action required: 705 - Other - as specified
Due 4 August 2008
Resolved 7 August 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 July 2008 Resolved
Renew first aid kit equipment to original content.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 7 August 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 28 July 2008 Resolved
Renew all missing structural fire protection in engine room
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 7 August 2008
Engineering › Lubricating Oil Storage/Transfer System › Inlet
Issued 28 July 2008 Resolved
Provide lube oil fill cap
Action required: 705 - Other - as specified
Due 29 July 2008
Resolved 7 August 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 July 2008 Resolved
Provide proof of valid VI State registration.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 7 August 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 July 2008 Resolved
Ensure that all crewmembers are enrolled in a company drug testing program (sp. Peterson Eugene)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2008
Resolved 7 August 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 28 July 2008 Resolved
Renew missing lighting fixture over bilge manifold in engine room
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 7 August 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 July 2008 Resolved
Replace/renew rubber hose IWO port main diesel overboard discharge.
Action required: 705 - Other - as specified
Due 4 August 2008
Resolved 7 August 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 July 2008 Resolved
Remove/clean/reconnect 10" hose where noted leaking at overboard discharge for starboard MDE.
Action required: 705 - Other - as specified
Due 4 August 2008
Resolved 7 August 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 28 July 2008 Resolved
Prove proper operation of ventilation closure valves BTWN E/R and aft compartment (steering)
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 29 July 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 October 2007 Resolved
PROVIDE ORIGINAL, VALID CERTIFICATE OF DOCUMENTATION TO BE POSTED IN WHEELHOUSE.
Action required: 705 - Other - as specified
Due 18 October 2007
Resolved 18 October 2007
Documentation › Logs/Records › Drug Test Records
Issued 19 March 2007 Resolved
Provide proof of current enrollment for all crew in drug and alcohol testing consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2007
Resolved 17 April 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 March 2007 Resolved
Provide current navigation publications, i.e. Reed's Almanac.
Due 26 March 2007
Resolved 17 April 2007
Communications › Radio Communications › EPIRB
Issued 19 March 2007 Resolved
Renew/replace safety stopper on EPIRB.
Due 19 March 2007
Resolved 19 March 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 March 2007 Resolved
Provide 14 additional adult lifejackets.
Due 19 March 2007
Resolved 17 April 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 March 2007 Resolved
Secure mounting device for portable fire extinguisher located in aft passenger cabin area.
Due 19 March 2007
Resolved 17 April 2007
Lifesaving › Lifebuoys › Serviceable
Issued 19 March 2007 Resolved
Renew/replace two ring buoys located on foward bow area, upper deck.
Due 19 March 2007
Resolved 17 April 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 March 2007 Resolved
Renew/replace placards for lifejacket stowage.
Due 19 March 2007
Resolved 17 April 2007
Fire Fighting › Firemans Outfit › Axe
Issued 19 March 2007 Resolved
Label fire axe with vessel's name.
Due 19 March 2007
Resolved 17 April 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 March 2007 Resolved
INSTALL LAGGING ON PMDE TURBOCHARGER OUTLET ELBOW
Due 19 March 2007
Resolved 17 April 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 March 2007 Resolved
INSTALL LAGGING ON INBOARD SMDE TURBOCHARGER OUTLET PIPING
Due 19 March 2007
Resolved 17 April 2007
Electrical › Electric Generation Source (service) › Generator
Issued 19 March 2007 Resolved
CLEAN OIL FROM GENERATOR WINDINGS BOTH SHIPS SERVICE GENERATORS
Due 20 April 2007
Resolved 17 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 March 2007 Resolved
REPAIR FRAYED WIRING CONNECTIONS TO PORT GENERATOR BATTERY
Due 19 March 2007
Resolved 17 April 2007
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 19 March 2007 Resolved
REMOVE OILY WATER FROM GENERATOR ROOM BILGES AND PRESSURE WASH ALL DEBRIS FROM BILGE PLATING SURFACES FOR FURTHER INSPECTION.
Due 19 March 2007
Resolved 17 April 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 24 July 2006 Resolved
SERVICE OR REPLACE INTERIOR PASSENGER SALON FORWARD PORTABLE FIRE EXTINGUISHER.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2006
Resolved 29 August 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 24 July 2006 Resolved
AT NEXT HULL EXAMINATION, RECONFIGURE CURRENT SEWAGE TANK DISCHARGE PIPING TO REFLECT REMOVAL OF TRANSOM OVERBOARD IN ITS ENTIRETY. OVERBOARD SHALL BE RELOCATED WITHIN THE PORT OR STARBOARD SIDES OF HULL WELL ABOVE VESSELS WATERLINE. THE DESIGN, MATERIALS AND INSTALLATION SHALL BE CG APPROVED PRIOR TO STARTING WORK.
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 2 November 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 29 June 2006 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF SEWAGE DISCHARGE VALVE AT TRANSOM AND PROVIDE MEANS TO LOCK IN CLOSED POSITION. BOTH AFT RESTROOMS ARE TO BE CLOSED FOR USE UNTIL COMPLETED TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2006
Resolved 30 June 2006
Resolution: Installed new valve and new lock.
Stability › Watertight Integrity › General
Issued 29 June 2006 Resolved
PRIOR TO CARRYING PASSENGERS, REMOVE ALL INTERFERENCES FROM AFT ENGINEERING BULKHEAD WATERTIGHT DOOR THRU-WAY TO ALLOW PROPER CLOSURE AT ALL TIMES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2006
Resolved 30 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 29 June 2006 Resolved
CORRECT ALL PORTABLE FIRE EXTINGUISHER SERVICE TAGS THAT DO NOT REFLECT THE ACTUAL SERVICING YEAR.
Action required: 705 - Other - as specified
Due 14 July 2006
Resolved 24 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 June 2006 Resolved
RENEW PORT MAIN ENGINE EXHAUST FLEXIBLE RUBBER.
Action required: 705 - Other - as specified
Due 14 July 2006
Resolved 24 July 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 June 2006 Resolved
PRIOR TO CARRYING PASSENGERS, REMOVE ALL EXCESS MARINE BATTERIES FOUND ON THE DECK IN THE MAIN DECK INTERIOR PASSENGER SALON, ENGINE ROOM AND STEERING GEAR ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2006
Resolved 30 June 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 29 June 2006 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF ALL INSTALLED ELECTRICAL BATTERY CHARGERS AND REMOVE ALL PORTABLE BATTERY CHARGERS FROM VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2006
Resolved 30 June 2006
Stability › Unintentional Flooding › General
Issued 29 June 2006 Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO SEWAGE IN-LINE SWING CHECK VALVE FLANGE LEAK IN STEERING GEAR ROOM AND REMOVE ALL LIQUIDS FROM BILGES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2006
Resolved 30 June 2006
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 29 June 2006 Resolved
PRIOR TO CARRYING PASSENGERS, ISOLATE ALL FITTINGS IN LINE OF SEWAGE PIPING TO PREVENT OPENING AND/OR INTRODUCING OTHER LIQUIDS/DEBRIS INTO SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2006
Resolved 30 June 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 May 2006 Resolved
RENEW HOLED, WASTED SEA-WATER EXHAUST PIPE FOR PORT GENERATOR EXHAUST AT TRANSOM, IN ITS ENTIRETY.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 24 July 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 April 2006 Resolved
RENEW HOLED, AND TEMPORARILY PATCHED, STARBOARD GENERATOR EXHAUST PIPE AT TRANSOM IN ITS ENTIRETY.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 10 May 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 April 2006 Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHT FIXTURES.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 13 April 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2006 Resolved
MAKE PERMANENT REPAIRS TO HOLED GENERATOR ENGINE EXHAUST PIPING AT TRANSOM, PORT AND STARBOARD, AS SHOWN.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 13 April 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2006 Resolved
RENEW PORT AND STARBOARD GENERATOR ENGINE RAW WATER EXHAUST COOLING HOSES AT TRANSOM PIPE AND DOUBLE UP WITH STEEL CLAMPS.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 13 April 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2006 Resolved
DOUBLE UP STEEL CLAMPS FOR STARBOARD MAIN ENGINE RAW WATER COOLING PIPING HOSES.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 13 April 2006
Documentation › Certificates/Documents › Stability Letter
Issued 11 April 2006 Resolved
PERMANENT DISPLAY STABILITY LETTER IN ITS ENTIRETY UNDER GLASS IN THE WHEELHOUSE.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 13 April 2006
Documentation › Certificates/Documents › FCC SSL
Issued 11 April 2006 Resolved
PROVIDE COPY OF FCC VESSEL BRIDGE TO BRIDGE CERTIFICATE.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 13 April 2006
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF THAT CREW IS ENROLLED IN DRUG CONSORTIUM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL VESSELS NAME ON PORT AND STARBOARD FORWARD HULL AND VESSELS NAME AND HAILING PORT ON VESSELS STERN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Electrical › Lighting (emergency) › Lighting Feeder
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF ALL EMERGENCY LIGHT FIXTURES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Fire Fighting › Nozzles › Type
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF APPROVED FIRE HOSE NOZZLE FOR EACH FIRE STATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Engineering › Bilge Water Management System › Not Installed
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF VISUAL AND AUDIO ALARM FOR THE ENGINE ROOM AND RUDDER ROOM HIGH BILGE WATER LEVEL ALARM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Engineering › Bilge Water Management System › Not Installed
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROPERLY IDENTIFY AND LABEL THE HIGH BILGE WATER LEVEL ALARMS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Personnel › Training › First Aid/CPR
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF THAT FIFTY (50) PERCENT OF CREW HAS CURRENT CPR TRAINING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 August 2004 Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT SATISFACTORY UNDERWAY FIRE, MAN OVERBOARD/RECOVERY AND ABANDON SHIP DRILLS IN THE PRESENCE OF THE U. S. COAST GUARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2004
Resolved 20 August 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 April 2003 Resolved
PROVIDE EVIDENCE OF LIFESAVING AND FIREFIGHTING EQUIPMENT MAINTENANCE
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 April 2003 Resolved
RENEW FIRE EXTINGUISHER BRACKET IN MAIN DECK AFT PASSENGER CABIN
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Fire Fighting › Fire Pumps
Issued 14 April 2003 Resolved
REPAIR ENGINE DRIVEN FIRE PUMP
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Lifesaving › Buoyant Apparatus
Issued 14 April 2003 Resolved
COMPLETELY RENEW 2 PORT BOW LIFEFLOATS AND 1 STBD BOW LIFEFLOAT PRIOR TO THE CARRIAGE OF PASSENGERS
Due 14 April 2003
Resolved 1 May 2003
Lifesaving › Buoyant Apparatus
Issued 14 April 2003 Resolved
RENEW ALL GRAB LINES ON STBD BOW LIFEFLOAT
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Lifesaving › Buoyant Apparatus
Issued 14 April 2003 Resolved
REMOVE OR RENEW UPPER DECK BOUYANT APPARATUS
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 14 April 2003 Resolved
LABEL ALL SUCTION AND DISCHARGE VALVES ASSOCIATED WITH ENGINE DRIVEN BILGE/FIRE PUMP
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 April 2003 Resolved
ATTACH LIFERING TO LIGHT AND MAKE LIGHT OPERABLE
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 14 April 2003 Resolved
REPAIR LEAKING BILGE DISCHARGE PIPING IN ENGINE ROOM IWO BILGE MANIFOLD
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 April 2003 Resolved
INSTALL EXHAUST LAGGING IN VICINITY OF TURBO CHARGER EXHAUST PIPING ON STBD AND PORT OUTBOARD ENGINES
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Fire Fighting › Fire Hoses › Condition
Issued 14 April 2003 Resolved
RENEW FIRE HOSE IN FORWARD ENGINE ROOM
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Engineering › Steering Gear System › Bracket/Clamp
Issued 14 April 2003 Resolved
TIGHTEN PORT AND STBD RUDDER ARMS
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 April 2003 Resolved
MAKE WATERTIGHT DOOR ALARMS OPERABLE
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 April 2003 Resolved
RELABEL LIFEJACKET STORAGE BOXES ON UPPER DECK
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 21 April 2003
Communications › Radio Communications › EPIRB
Issued 14 April 2003 Resolved
RENEW HYDROSTATIC RELEASE
Due 30 April 2003
Resolved 21 April 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 April 2003 Resolved
LABEL EMERGENCY ESACPE LADDER FOR UPPER DECK WITH LARGER LETTERS
Due 30 April 2003
Resolved 21 April 2003
Electrical › Lighting (emergency)
Issued 14 April 2003 Resolved
RENEW ELECTRICAL DECK LIGHT FIXTURE ABOVE PORT MAIN FWD CABIN DOOR AND ON BOW FOREDECK CENTER LEGACY COMPONENT DESC: Lighting Fixture
Due 14 May 2003
Resolved 14 April 2003
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 April 2003 Resolved
REPAIR/RENEW ROTTED BATTERY BOXES IN FWD ENGINE ROOM
Due 14 April 2003
Resolved 21 April 2003
Engineering › Steering Gear System › Actuator
Issued 14 April 2003 Resolved
REPAIR LEAKING HYDRAULIC STEERING CYLINDER SEAL
Due 22 April 2003
Resolved 21 April 2003
Engineering › Steering Gear System
Issued 14 April 2003 Resolved
ADJUST RUDDER STOPS TO MAXIMUM HYDRAULIC RAM TRAVEL AT NEXT DRY-DOCKING LEGACY COMPONENT DESC: Rudder
Due 1 July 2003
Resolved 14 April 2003
Lifesaving › Buoyant Apparatus
Issued 14 April 2003 Resolved
DUE TO THE LACK OF SUFFICIENT LIFEFLOATS, VESSEL IS RESTRICTED TO USVU NOT MORE THAN 3 MILES FROM LAND
Due 21 April 2003
Resolved 1 May 2003
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 14 April 2003 Resolved
VESSEL FAILED TO PROVIDE REQUIRED RECORDS OF LIFESAVING AND FIREFIGHTING EQUIPMENT MAINTENANCE. INTERNATIONAL ROUTE HAS BEEN REVOKED
Due 14 April 2003
Resolved 21 April 2003
Documentation › Logs/Records › Drug Test Records
Issued 17 April 2002 Resolved
PROVIDE CONSORTIUM CERTIFICATION FOR 1 CREWMEMBER
Due 17 April 2002
Resolved 17 April 2002
Documentation › Certificates/Documents
Issued 17 April 2002 Resolved
POST ALL REQUIRED CERTIFICATES
Due 24 April 2002
Resolved 14 April 2003
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 April 2002 Resolved
PROVIDE 1 ADDITIONAL PORTABLE LIGHT
Due 17 April 2002
Resolved 17 April 2002
Fire Fighting › Firemans Outfit
Issued 17 April 2002 Resolved
LABEL FIRE AXE WITH VESSEL'S NAME LEGACY COMPONENT DESC: Axe
Due 24 April 2002
Resolved 14 April 2003
Lifesaving › Lifebuoys
Issued 17 April 2002 Resolved
RENEW 2 RING BUOYS AS IDENTIFIED
Due 17 April 2002
Resolved 17 April 2002
Communications › Radio Communications › EPIRB
Issued 17 April 2002 Resolved
REPAIR BRACKET FOR EPIRB
Due 17 April 2002
Resolved 17 April 2002
Electrical › Lighting (service)
Issued 17 April 2002 Resolved
INSTALL COVERS ON LIGHT FIXYURES IN ENGINE ROOM AND FORWARD COMPARTMENT LEGACY COMPONENT DESC: Lighting Fixture
Due 24 April 2002
Resolved 14 April 2003
Engineering › Shafting/Propeller Arrangements
Issued 17 April 2002 Resolved
RENEW BROKEN HOSE CLAMP ON STBD INBOARD ENGINE STERN TUBE HOSE LEGACY COMPONENT DESC: Stern Gland
Due 24 April 2002
Resolved 14 April 2003
Engineering
Issued 21 August 2001 Resolved
REPAIR INBOARD AND OUTBOARD PROPELLERS.
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Navigation
Issued 21 August 2001 Resolved
REPLACE PORT RUDDER ARM CAP.
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Engineering
Issued 21 August 2001 Resolved
RENEW STBD OUTBOARD SHAFT CUTLASS BEARING.
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Navigation
Issued 21 August 2001 Resolved
RENEW PORT AND STBD RUDDER BEARINGS
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Lifesaving
Issued 21 August 2001 Resolved
INSTALL BRACKETS FOR LIFEFLOAT STROBES TO PERMIT FLOAT-FREE OPERATION.
Condition: Unknown
Due 21 September 2001
Resolved 4 December 2001
Electrical
Issued 21 August 2001 Resolved
INSTALL GLOBES AND GUARDS ON ALL OVERHEAD LIGHTING.
Condition: Unknown
Due 21 September 2001
Resolved 4 December 2001
Construction/Loadline
Issued 21 August 2001 Resolved
RENEW TWO FORWARD VALVES LABELED BALLAST TANK.
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Construction/Loadline
Issued 21 August 2001 Resolved
OVERHAUL ALL 4 MAIN ENGINE SEA SUCTION VALVES.
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Engineering
Issued 21 August 2001 Resolved
REPACK ALL 4 SHAFT PACKING GLANDS.
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Construction/Loadline
Issued 21 August 2001 Resolved
OVERHAUL GENERATOR SEA SUCTION VALVES.
Condition: Unknown
Due 21 August 2001
Resolved 4 December 2001
Documentation
Issued 24 April 2001 Resolved
PROVIDE CPR CERTIFICATION FOR AT LEAST 50% OF THE CREW.
Condition: Unknown
Due 20 May 2001
Resolved 7 June 2001
Documentation
Issued 24 April 2001 Resolved
PROVIDE LIFESAVING AND FIREFIGHTING EQUIPMENT MAINTENANCE LOGS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Navigation
Issued 24 April 2001 Resolved
PROVIDE COPY OF INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 24 April 2001 Resolved
RENEW EPIRB HYDROSTATIC RELEASE NO LATER THAN 20MAY01.
Condition: Unknown
Due 20 May 2001
Resolved 7 June 2001
Engineering
Issued 24 April 2001 Resolved
LABEL EMERGENCY FUEL SHUT-OFF VALVES WITH 1" HIGH LETTERS AT EACH DECK ACCESS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Fire Fighting
Issued 24 April 2001 Resolved
LABEL ALL SUCTION AND DISCHARGE VALVES ASSOCIATED WITH THE ENGINE DRIVEN FIRE/BILGE PUMP PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 24 April 2001 Resolved
REPAIR ALL LIFEFLOATS THAT HAVE EXPOSED FLOTATION DUE TO GOUGES, RIPS, AND TEARS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Electrical
Issued 24 April 2001 Resolved
REMOVE DEAD ENDED WIRE IN FOREPEAK NO LATER THAN 20MAY01.
Condition: Unknown
Due 20 May 2001
Resolved 7 June 2001
Lifesaving
Issued 24 April 2001 Resolved
TIGHTEN WEAK LINK BRACKETS FOR LIFEFLOATS LOCATED ON PORT AND STARBOARD BOWPRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Fire Fighting
Issued 24 April 2001 Resolved
RENEW FIRE EXTINGUISHER BRACKET IN MAIN DECK FORWARD PASSENGER AREA PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Electrical
Issued 24 April 2001 Resolved
REPAIR ALL EMERGENCY LIGHTING PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Fire Fighting
Issued 24 April 2001 Resolved
REPAIR ENGINE DRIVEN FIRE PUMP PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 24 April 2001 Resolved
RENEW ALL LIFEJACKETS AS DESIGNATED BY THE CG INSPECTOR. ALL LIFEJACKET LIGHTS ARE TO BE CHECKED BY THE CREW PRIOR TO REINSPECTION.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Construction/Loadline
Issued 15 February 2000 Resolved
Repair indicator light for bilge high level alarm in the engineroom.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Construction/Loadline
Issued 15 February 2000 Resolved
Properly wire bilge high level alarm in the rudder room.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 15 February 2000 Resolved
Re-stencil emergency fuel shutoffs.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Engineering
Issued 15 February 2000 Resolved
Double clamp exhaust hose for port inboard engine.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 15 February 2000 Resolved
Provide 8 additional adult PFD's. Vessel is limited to not more than 280 total persons until corrected.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 15 February 2000 Resolved
Provide lights and/or whistles for 31 adult & 1 child PFDs.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 15 January 1999 Resolved
Provide lights and whistles for 15 adult PFD's.
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Fire Fighting
Issued 15 January 1999 Resolved
Perform annual servicing on all 6 portable fire extinguishers.
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Electrical
Issued 15 December 1997 Resolved
Repair announcing system prior to loading passengers.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Construction/Loadline
Issued 15 December 1997 Resolved
Clean and gas free P/S ballast tanks prior to loading passengers. (To the satisfaction of the attending marine inspector.)
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Engineering
Issued 24 June 1997 Resolved
CROP AND RENEW PORT SIDE GENERATOR EXHAUST.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Construction/Loadline
Issued 24 June 1997 Resolved
CONTACT COAST GUARD MSO NEW ORLEANS UPON ARRIVAL TO THEIR ZONE TO CORDINATEALL ALUMINUM REPAIRS. REMOVE STRUCTUAL FIRE PROTECTION FOR THE INSPECTION OF SIDE SHELL AND ASSOCATED FRAME DAMAGE BY WAY OF ENGINE ROOM AND GEN ROOM. ATTENDING INSPECTOR MAY REQUIRE MORE SIDE SHELL/FRAME RENEWAL
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Fire Fighting
Issued 24 June 1997 Resolved
RENEW ALL STRUCTURAL FIRE PROTECTION ON VESSEL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Construction/Loadline
Issued 24 June 1997 Resolved
CROP AND RENEW PORT AND STARBOARD SIDE SHELL AND ALL ASSOCIATED FRAMING FROM SECOND EXISTING SHELL PLATE - AFT 40 FEET AND FROM WATERLINE TO DECK LEVEL. CROP AND RENEW DECK UPSET -- PORT SIDE BY WAY OF WHEEL HOUSE. CROP AND RENEW BOTH STERN CORNERS AND FORWARD ON PORT SIDE 4'.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Construction/Loadline
Issued 24 June 1997 Resolved
PROVIDE BILGE STRAINERS FOR ALL BILGE SUCTIONS.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Navigation
Issued 2 August 1996 Resolved
REPAIR OR REPLACE HYDRAULIC PACKING SEAL IN STEERING RAM.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Engineering
Issued 2 August 1996 Resolved
INSTALL MISSING BOLTS IN ALL FOUR ENGINES MOTOR MOUNTS AS NEEDED.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Documentation
Issued 2 August 1996 Resolved
LOG EMERGENCY CREW DRILLS IN ACCORDANCE WITH NEW INTERIM FINAL RULE.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Lifesaving
Issued 2 August 1996 Resolved
INSTALL ONE FLASHLIGHT EACH AT THE OPERATING STATION AND ENTRANCE TO ENGINEROOM.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Accommodation/Occupational Safety
Issued 2 August 1996 Resolved
REPLACE PVC VALVE ON MSD OVERBOARD WITH A METALLIC VALVE
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Documentation
Issued 2 August 1996 Resolved
Create a log book and record all drills, training, etc. per interm final rule.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Accommodation/Occupational Safety
Issued 2 August 1996 Resolved
REPAIR CRACK IN PORT BRIDGE HAND RAIL.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Accommodation/Occupational Safety
Issued 2 August 1996 Resolved
INSTALL RADIO PLACARD IN ACCORDANCE WITH NEW INTERIM FINAL RULE.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Accommodation/Occupational Safety
Issued 2 August 1996 Resolved
INSTALL A MSD TANKWATCH SYSTEM IN ACCORDANCE WITH 33 CFR 159.83.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Lifesaving
Issued 2 August 1996 Resolved
NO LATER THAN 11 MARCH 1997, INSTALL ON BOARD IN A FLOAT FREE ARRANGEMENT, A FCC ACCEPTED, CATEGORY 1, 406MHZ EPIRB.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Lifesaving
Issued 2 August 1996 Resolved
INSTALL DISTRESS FLARES IN A BRIGHT COLORED CONTAINER, AND MARK CONTAINER DISTRESS SIGNALS.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Fire Fighting
Issued 2 August 1996 Resolved
MOUNT BRIDGE B-I FIRE EXTINGUISHER IN A MARINE TYPE BRACKET.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Construction/Loadline
Issued 2 August 1996 Resolved
MAKE VSL AVAILABLE FOR REPAIRS TO DAMAGED SIDESHELL AND INTERNAL FRAMING ASDESCRIBED IN YOUR LETTERS DATED 15MAY96 AND 17JUN96._x001C_
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Lifesaving
Issued 2 August 1996 Resolved
INSTALL B/As PAINTER LINES IN FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 2 September 1996
Resolved 12 August 1996
Construction/Loadline
Issued 11 June 1996 Resolved
REPAIR FRACTURES ON LOWER TRANSVERSE FRAME AS MARKED BY CG IN THE FOREPEAK.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Engineering
Issued 11 June 1996 Resolved
REPLACE UPPER AND LOWER CUTLASS BEARING ON PORT OUTBOARD PROPELLER.
Condition: Unknown
Due 15 June 1996
Resolved 15 June 1996
Engineering
Issued 11 June 1996 Resolved
REPLACE STARBOARD INBOARD PROPELLER.
Condition: Unknown
Due 15 June 1996
Resolved 15 June 1996
Fire Fighting
Issued 11 June 1996 Resolved
RENEW STRUCTUAL FIRE PROTECTION IN THE GENERATOR COMPARTMENT AS NEEDED IN WAY OF THE STERN CORNERS.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Construction/Loadline
Issued 11 June 1996 Resolved
PROVIDE CG A PROPOSAL TO REPAIR DEFLECTED TRANSVERSE FRAMES IN COMPARTMENT #3 PORT AND STARBOARD SIDES.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Fire Fighting
Issued 11 June 1996 Resolved
TEMPORARILY REMOVE STRUCTUAL FIRE PROTECTION AT FRAME #3 THRU STERN CORNER IN GENERATOR COMPARTMENT FOR CG INSPECTION OF SIDESHELL AND DEFLECTED FRAMES.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Construction/Loadline
Issued 11 June 1996 Resolved
RENEW EXHAUST WATER HOSE CLAMPS IN LAZARETTE. HOSES TO BE DOUBLE CLAMPED AT BOTH ENDS.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Engineering
Issued 11 June 1996 Resolved
REPLACE PORT AND STARBOARD GENERATOR MACHINERY GUARDS.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Construction/Loadline
Issued 11 June 1996 Resolved
PROVIDE CG A PROPOSAL TO REPAIR INSETS AND DEFLECTED FRAMING IN #2 COMPARTMENT - STARBOARD SIDE AT AFT BULKHEAD.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Fire Fighting
Issued 11 June 1996 Resolved
TEMPORARILY REMOVE STRUCTUAL FIRE PROTECTION IN GENERATOR COMPARTMENT FROM THE OVERHEAD/SIDESHELL TRANSITION AND HALF WAY DOWN FOR CG INSPECTION OF SIDESHELL PLATTING.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Documentation
Issued 11 June 1996 Resolved
PROVIDE DOCUMENTATION OF ORGINAL SCANTLING OF HULL/SIDESHELL.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Documentation
Issued 11 June 1996 Resolved
PROVIDE CG A REPORT OF HULL GAUGING FROM A COMPETENT MARINE SURVEYOR._x001C_ GAUGINGS TO BE DONE IN THE PRESENCE OF CG AND IN WAY OF PITTING IN LAZARETTE AND ENGINE ROOM. DECK PLATING TO BE REMOVED FOR FURTHER INSPECTION._x001C_
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Documentation
Issued 11 June 1996 Resolved
PROVIDE COAST GUARD A PROPOSAL TO REPAIR ANY WASTAGE OF HULL OVER .25 PER CENT.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Fire Fighting
Issued 3 August 1995 Resolved
PROVIDE PROOF OF SERVICING OR 3 ADDITIONAL TYPE B-II FIRE EXTINGUISHERS, PRIOR TO VESSEL OPERATING WITH PASSENGERS.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Lifesaving
Issued 3 August 1995 Resolved
PROVIDE FCC EXEMTPTION FOR EPIRB OR REPLACE BATTERY BEFORE SAILING ON AN INTERNATIONAL VOYAGE.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Electrical
Issued 3 August 1995 Resolved
INSTALL MACHINERY GUARDS ON ALL GENERATORS.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Accommodation/Occupational Safety
Issued 3 August 1995 Resolved
PROVIDE AN MSD POLLUTION SIGN LOCATED ADJACENT TO THE MSD OVERBOARD VALVES.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 3 August 1995 Resolved
MAKE REPAIRS TO MARKED WELDS AND FRAMES IN FOREPEAK (3 CRACKED WELDS AND 2 CRACKED FRAMES).
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 12 June 1995 Resolved
Secure hatch to storage compartment with a suitable chain or cable.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Accommodation/Occupational Safety
Issued 12 June 1995 Resolved
Install operating instruction signs adjacent to Marine Sanitation Device overboard discharge valves stating valves must be closed while within 3 miles of a U.S. shoreline and that discharge within 3 miles of a U.S. shoreline is illegal.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Construction/Loadline
Issued 12 June 1995 Resolved
Repair 2" crack on port side below rubrail under breast cleat.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Construction/Loadline
Issued 12 June 1995 Resolved
Repair cracked welds on port side in storage compartment marked by the Coast Guard with yellow crayon.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 5 August 1994 Resolved
PROVIDE FLOAT LIGHTS FOR ALL BUOYANT APPARATUS.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Fire Fighting
Issued 12 August 1993 Resolved
PROVIDE PROPER BRACKETS FOR PORTABLE EXTINGUISHERS LOCATED IN ENGINE ROOM AND GENERATOR SPACE.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Documentation
Issued 12 August 1993 Resolved
Obtain exemption certificate for newly required NAVTEX equipment from FCC.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Lifesaving
Issued 12 August 1993 Resolved
INSTALL RACKS TO PROPERLY STOW BOUYANT APARATUS ON BOW.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Electrical
Issued 12 August 1993 Resolved
REPAIR ALL MALFUNCTIONING EMERGENCY LIGHTS.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Fire Fighting
Issued 12 August 1993 Resolved
PROVIDE PROPER LABALING FOR FIRE/BILGE MANIFOLD.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Construction/Loadline
Issued 12 August 1993 Resolved
PROVIDE MANUFACTURERS DATA ON ALL ELECTRICAL BILGE PUMPS TO MSD_x001C_ ST. THOMAS FOR CG FILES.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Lifesaving
Issued 12 August 1993 Resolved
PROVIDE DIVIDERS BETWEEN STACKS OF BOUYANT APPARATUSs.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Lifesaving
Issued 25 November 1992 Resolved
Provide additional primary lifesaving equipment to agree with vessel's COI.The vessel presently has adequate primary lifesaving equipment for the Coastwise route, but is restricted to 188 passengers on the International route.
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Lifesaving
Issued 25 November 1992 Resolved
Provide weak links for Buoyant Apparatus and Liferafts where missing.
Condition: Unknown
Due 28 November 1992
Resolved 27 November 1992
Electrical
Issued 14 August 1992 Resolved
Provide rating plate for both generators for an ambient temperature of 50 degrees Centigrade OR provide documentation that the generator space is a 40 degree space.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Construction/Loadline
Issued 14 August 1992 Resolved
Provide strainers for bilge suctions located in #2 P and #2 S compartments.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Construction/Loadline
Issued 14 August 1992 Resolved
Provide hold back device for watertight hatch leading into forepeak.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Electrical
Issued 14 August 1992 Resolved
Remove dead end wiring under bridge console and re-wire temporarily wired equipment to good marine practice.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Lifesaving
Issued 14 August 1992 Resolved
Provide 3 additional orange smoke flares for a total of 6.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Lifesaving
Issued 14 August 1992 Resolved
Stencil name of vessel on all ring buoys.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Lifesaving
Issued 14 August 1992 Resolved
In the presence of a Coast Guard marine inspector, conduct a satisfactory man overboard drill and fire drill.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Electrical
Issued 14 August 1992 Resolved
Provide protective guards on belts on port side generator.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Engineering
Issued 14 August 1992 Resolved
Identify and repair leaks in exhaust system in way of cooling water injection for all engine exhaust systems.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Engineering
Issued 14 August 1992 Resolved
Clean oil and sludge from exhaust ventilation ducting in engine room.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Accommodation/Occupational Safety
Issued 14 August 1992 Resolved
Provide door handles for women's head and port side main passenger entrance/exit.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Lifesaving
Issued 14 August 1992 Resolved
Provide lifejacket donning placard and emergency instructions for each passenger area.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Lifesaving
Issued 14 August 1992 Resolved
Provide shackle for weak link on forward starboard liferaft.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Construction/Loadline
Issued 16 August 1991 Resolved
REPAIR 2" CRACK IN #2 WEB FRAME WELD IN FORWARD PEAK.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Construction/Loadline
Issued 16 August 1991 Resolved
PROPERLY SEAL WATERTIGHT DOOR IN FORWARD ENGINE ROOM.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Construction/Loadline
Issued 18 June 1991 Resolved
GOUGE-OUT AND REWELD RUB RAIL ON PORT QUARTER AT THE SHEER WHERE IT IS CRACKED IN APPROXIMATELY THREE AREAS. GOUGE-OUT AND REWELD REINFORCING STRAPS ON PORT STERN CORNER.
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Accommodation/Occupational Safety
Issued 18 June 1991 Resolved
PROVIDE NEW VALVE HANDLES FOR ALL SEA VALVES WHICH DO NOT HAVE HANDLES AND REPLACE ALL VALVE HANDLES WHICH ARE BROKEN.
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Lifesaving
Issued 17 August 1990 Resolved
PERMANENTLY MOUNT PORT L/R RACK.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Lifesaving
Issued 17 August 1990 Resolved
OBTAIN FIVE ADDITIONAL CHILD'S SIZE PFD'S.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Accommodation/Occupational Safety
Issued 17 August 1990 Resolved
PROVIDE SIGNS WHICH STATE, "WTD KEEP CLOSED AT ALL TIMES" AND "EMERGENCY ESCAPE KEEP CLEAR", FOR ENGINE DOORS AND ESCAPE SCUTTLE.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Lifesaving
Issued 17 August 1990 Resolved
PROVIDE THREE ADDITIONAL PARACHUTE FLARES FOR A TOTAL OF TWELVE FOR INTERNATIONAL ROUTE.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Navigation
Issued 17 August 1990 Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Fire Fighting
Issued 17 August 1990 Resolved
MOUNT FIRE AXE AND PAINT VESSEL'S NAME ON HANDLE.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Fire Fighting
Issued 17 August 1990 Resolved
PROVIDE UL APPROVED BRACKETS FOR PORTABLE CO2 EXTINGUISHERS.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Fire Fighting
Issued 17 August 1990 Resolved
PROVIDE A HAND OPERATED FIRE AND BILGE PUMP.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Construction/Loadline
Issued 17 August 1990 Resolved
SECURE 1 1/2" HOLE BETWEEN E/R AND GEN. SPACE LOCATED STBD. SIDE.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Lifesaving
Issued 17 August 1990 Resolved
SERVICE TWO 25 MAN LIFE RAFTS.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Engineering
Issued 17 August 1990 Resolved
REPAIR PINHOLE LEAK ON STBD GENERATOR HEAT EXCHANGER.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Electrical
Issued 17 August 1990 Resolved
PROVIDE METALLIC GUARD OVER LIGHT FIXTURE SO GLASS GLOBE IS NOT EXPOSED.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Electrical
Issued 17 August 1990 Resolved
PROVIDE RUBBER ELECTRICAL SAFETY MAT IN FRONT OF ELECTRICAL SWITCH BOARD.
Condition: Unknown
Due 17 August 1990
Resolved 17 August 1990
Unknown
Issued 18 June 1990 Resolved
REPLACE ELEVEN WINDOWS IN THE MAIN ACCOMODATION AREA THAT ARE CRACKED DUE TO IMPROPER CLAMPS.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 18 June 1990 Resolved
MAKE REPAIRS TO THE 2 INCH CRACK IN THE PORT BALLAST COMPARTMENT BETWEEN FRAME 3 AND THE AFT BULKHEAD OF THIS COMPARTMENT. THE HOLE MUST BE DRILL STOPPED AT EACH END OF THE CRACK AND THE HOLE WELDED FOR COMPLETE PENERTA- TION.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 18 June 1990 Resolved
PROVIDE A LADDER OR OTHER SUITABLE MEANS TO ENTER THE STARBOARD BALLAST TANK FOR INSPECTION. MAKE THE SPACE AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 22 August 1989 Resolved
COMPLETE ANNUAL SERVICING ON ONE 20 MAN INFLATABLE LIFERAFT OR PROVIDE ONBOARD A 20 MAN RAFT WITH A VALID SERVICE INTERVAL.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Construction/Loadline
Issued 9 August 1988 Resolved
REPAIR OR REPLACE COAMING OF TONNAGE OPENING(LOCATED AT TRANSVERSE BULKHEADFRAME 22 BETWEEN MAIN AND BRIDGE DECK) TO MEET REQUIRED HEIGHTH OF SIX(6) INCHES AS REQUIRED BY 46 CFR 171.124
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Documentation
Issued 9 August 1988 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988

Casualty record · 1

9 March 2001Routine · role: Involved in a Marine Casualty · activity 46837
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record