02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical shock. The Emergency Switch for the battery installation located in the aft most container on deck was not secured to a bulkhead. Install breaker on a bulkhead to the satisfaction of the attending CG marine inspector. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 17 December 2025
Resolution: Emergency switch has been properly mounted. Picture uploaded under "documents" of this section.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2025
Resolved
The number and identification of the item stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The stowage locations for adult and children life jackets were not marked for identification, size, or number. Mark, in clearly legible letters, quantity of life jackets, and life jacket size (adult or child) to the satisfaction of the attending CG marine inspector. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 22 December 2025
Resolution: MI verified stowage and markings of life jackets, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 December 2025
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. None of the crew members on board had their marine radio operator permit on board. Provide a marine radio operator permit for a crew member to the satisfaction of the attending CG marine inspector. 47 CFR 80.159(e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 29 December 2025
Resolution: A copy of the permit was provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 November 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. (1) A space with a through-hull fitting below the deepest load waterline. Port stern compartment high level bilge alarm was inoperable. Vessel shall be operated with (1) additional deckhand while underway at all times until deficiency is rectified. Additional deckhand shall complete rounds of the port head space on at least 15 minute intervals. The deficiency shall be rectified within one week (11/26).
46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2024
Resolved 21 November 2024
Resolution: Recieved video and pictures from operator of operations bilge alarms.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 November 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Vessel was not maintaining drill log per regulatory standards. Future drill entries shall be made in accordance with appropriate regulation.
46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2024
Resolution: Conducted traning and witnessed proper drill entries after completing drills.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 November 2024
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have community service hot-line number displayed.
46 CFR 16.401
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2024
Resolved 21 November 2024
Resolution: Received photo from operator of posted hot-line number.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2023
Resolved
A submersible electric bilge pump may be used as power bilge pump required by Table 182.520(a), provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Installed (2) submersible bilge pumps are not UL 1113 rated. Install UL 1113 rated bilge pumps with appropriate overcurrent protection and demonstrate operation to attending marine inspector.
46 CFR 182.520(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2024
Resolved 8 January 2024
Resolution: Witnessed operation of newly installed (2) submersible pumps that are UL 1113 rated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Installed Blue Sea fuses (4) in battery compartment as well as fuse on port outboard battery are blade type. Replace blade type fuses with cartridge type fuses.
46 CFR 183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2024
Resolved 18 January 2024
Resolution: Vessel installed UL 489 breakers to replace blade-type fuses in Blue Sea system. See attached picture.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 December 2023
Resolved
Each hatch exposed to the weather must be watertight. Each hatch cover must have securing devices. Starboard aft hatch missing part of watertight gasket and securing device. Port and starboard forward hatches missing watertight gaskets. Install gasket and securing devices for starboard aft hatch. Install watertight gasket on port and starboard forward hatches.
46 CFR 177.13-1
46 CFR 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Visually verified watertight gaskets and appropriate latching devices have been installed on required hatches.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 December 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Captain's chair is mounted to a platform that is not secured to the deck nor is there any securing devices to prevent the chair from moving while the vessel is underway. Secure the chair and platform so they do not move while the vessel is underway.
46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Verifed supports were added on the deck to prevent Captain's chair from moving.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 December 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Paracord used to secure the deck netting on bow of vessel is unsuitable for supporting passengers. Replace paracord with line suitable for supporting deck nets and weight of passengers.
46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Verified new line was installed on netting. Line and netting are capable of supporting passengers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 December 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Bolt used to secure deck railing to bimini top structure on starboard side has failed at the weld. Replace hardware and reweld to the satisfaction of the attending marine inspector or install another suitable means to secure the deck railing to the bimini top structure.
46 CFR 176.800
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Verified new weld was completed to secure deck railing and bimini top structure.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 December 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations including the requirement for maintaining current station installation certificates. The provided FCC Safety Radiotelephony Certificate was expired. Provide a valid FCC Safety Radiotelephony Certificate.
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2022
Resolved 20 December 2022
Resolution: FCC Safety Radiotelephony Certificate was provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 December 2022
Resolved
Each disposable hydrostatic release unit must replaced after having been in service for two years. The provided EPIRB disposable hydrostatic release was had passed it expiration date. Provide a new EPIRB hydrostatic release.
46 CFR 185.740
Action required: 10 - Deficiency Rectified
Resolved 15 December 2022
Resolution: A new disposable hydrostatic release for the EPRIB was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 November 2021
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC. The vessel's installation certificate was not current. Provide current, valid FCC safety certificate.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 29 November 2021
Resolution: A valid FCC Safety Certificate was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2020
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Four child size life jackets were not marked with appropriate retroreflective material. Provide appropriate markings to the satisfaction of the attending marine inspector. Child passenger count reduced to one.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 January 2021
Resolution: Attended vessel and witnessed newly installed retroreflective tape on all child size lifejackets.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 20 November 2020
Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed new operators valid MMC and medical certificate
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2020
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. The float switch on the starboard electric bilge pump is not secured, which prevents it from functioning properly. The float switch for the starboard electric bilge pump shall be secured to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed secured float switch.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 20 November 2020
Resolved
The master of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations. Garbage placard has been removed and shall be replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed installed garbage placard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 20 November 2020
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating Discharge of Oil Prohibited. The oil discharge placard has been removed and shall be replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed newly installed oil placard
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 20 November 2020
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessels emergency instructions are worn and unreadable. Replace emergency instructions poster.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed newly installed emergancy instructions
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 November 2020
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio is missing MMSI and LAT/LONG for DSC operation. Enter MSI and LAT/LONG into VHR radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed MMSI and GPS info in VHF radio
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 November 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The high level alarm for the starboard side did not provide visual indication. Repair or replace alarm to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed operational visual indicator on starboard high water alarm
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 November 2020
Resolved
All cable and wire must be installed with metal supports not more than 24 inches apart. The wiring for the port bilge pump is not properly supported and is laying in the bilge. Secure wire properly to the satisfaction of the attending USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed secured wires by port bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 20 November 2020
Resolved
At each initial and subsequent inspection for certification the marine inspector shall require all observed unsafe practices and hazardous situations be corrected. The vessels swim platform support brackets and supports are wasted beyond 25%. Submit repair proposal to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed repaired d-ring.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2020
Resolved
The Certificate of Inspection issued to a vessel describes the vessels minimum manning requirements and any equivalences accepted or authorized by the cognizant OCMI. The vessels Master does not hold a valid MMC due to incomplete medical certification. Vessel is required to be operated by, and shall not operate without, a Master holding a valid MMC with applicable endorsements as outlined by the vessels COI. Additionally, that Master shall possess knowledge of the vessel to include demonstrating emergency drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2021
Resolution: Attended vessel and witnessed new operators valid MMC and medical certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019
Resolved
Each ring life buoy on a vessel be approved in accordance with 46 CFR 160.050. Ring buoy grab line is falling apart, no name on the ring buoy and new battery for the floating waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2019
Resolved 12 November 2019
Resolution: New lifering with name, retroreflective tape and new battery for the floatinglight.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 30 October 2019
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2)
VHF radio missing MMSAI and LAT/LONG for DSC operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2019
Resolved 18 November 2019
Resolution: VHF radio had MMSI and LAT/LONG input.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. Supervisory personnel must receive at least 60 minutes of training. No Employee Assistance Program for licensed captain and crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 12 November 2019
Resolution: Information provided and training material reviewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019
Resolved
Conduct Chemical Testing Program Compliance Audit as required. No documentation of DAPI program requirements besides being enrolled in consortium.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2019
Resolved 13 November 2019
Resolution: Verified DAPI program and documentation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019
Resolved
A vessel must carry either a first-aid kit, approved under approval series 160.041 or a kit with equivalent contents and instructions. Replaced expired medications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 12 November 2019
Resolution: Vessel provided new first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 October 2019
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 lbs. Deck rail are cracked in multiple locations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 12 November 2019
Resolution: All deck rails repaired.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 12 February 2019
Resolved
THE COMPASS MUST BE ILLUMINATED. COMPASS LIGHT WAS MISSING.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: New light installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 February 2019
Resolved
OPERATOR SHALL BE PREPARED TO CONDUCT TESTS AND HAVE VESSEL READY FOR INSPECTION OF THE HULL STRUCTURE AND ITS APPURTENANCES. AFT ALUMINUM HULL CROSS MEMBER SUPPORTING THE HYDRAULIC STEERING DRIVE HAVE OPENINGS ALLOWING INGRESS OF SEAWATER.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Hydraulic hoses properly supported and holes sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2019
Resolved
FLEXIBLE HOSE RUNS MUST BE VISIBLE, EASILY ACCESSIBLE, PROTECTED FROM DAMAGE. HYDRAULIC HOSE TO HYDRAULIC STEERING RAM NEEDS TO BE PROPERLY SUPPORTED TO PREVENT CHAFFING AND DAMAGE.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Hydraulic hoses properly supported with hose retainers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 February 2019
Resolved
VESSELS UNDER 65 FT IN LENGTH MUST MEET UL 1104 "STANDARDS FOR MARINE NAVIGATION LIGHTS." LENS FOR PORT, STBD AND STERN LIGHTS ARE FOGGED LIMITING REQUIRED ILLUMINATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: New working navigational lights installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2019
Resolved
A VISUAL INDICATOR MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE WHEN ANY AUTOMATIC BILGE PUMP IS OPERATING. WHEN STBD BILGE PUMP IS RUNNING IN AUTOMATIC BILGE PUMP MODE, NO INDICATION AT CONTROL CONSOLE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Alarm replaced and tested satisfactorily
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2019
Resolved
RECEPTACLE OUTLETS OF THE TYPE PROVIDING A GROUNDED POLE MUST BE OF A CONFIGURATION THAT WILL NOT PERMIT IMPROPER CONNNECTION. NON MARINE 110V RECEPTACLE AND WIRING CONNECTED TO INVERTER.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Proper outlet with marine grade wiring installed.
Fire Fighting › Fire Bucket › Quantity
Issued 10 January 2018
Resolved
Provide three fire buckets IAW 46 CFR 181.610.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 10 January 2018
Resolution: Provided three fire buckets.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 January 2018
Resolved
Provide name of vessel on life ring IAW 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 10 January 2018
Resolution: Provided name of vessel on life ring.
Navigation › Piloting/Steering › Marine Charts
Issued 10 January 2018
Resolved
Provide updated navigation chart, current tables, tide tables, coast pilot, and light list IAW 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 10 January 2018
Resolution: Provided updated navigation chart, current tables, tide tables, coast pilot, and light list.
Engineering › Bilge Water Management System › Interface Detector
Issued 10 January 2018
Resolved
Prove proper operation of port and starboard bilge visual indicators IAW 46 CFR 182.530(c).
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Proved proper operation of port and starboard bilge visual indicators.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 January 2018
Resolved
Provide securing devices for each hatch on deck IAW 46 CFR 179.360.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Provided securing devices for all hatch on deck.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 January 2018
Resolved
Provide separate stowage of life jackets from additional personal flotation devices IAW 46 CFR 180.78(b).
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Provided separate stowage of life jackets from additional personal flotation devices.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 January 2018
Resolved
Provide one additional adult life vest IAW 46 CFR 180.71. Passenger count is reduced to 36 until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Provided one additional adult life vest. Passenger count is back to 37 IAW COI.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 January 2018
Resolved
Ensure life jackets match donning placard IAW 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Installed life jacket donning placard that matches vest.
Communications › Radio Communications › EPIRB
Issued 7 November 2016
Resolved
Relocate EPIRB to float-free location.
Due 7 December 2016
Resolved 28 November 2016
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 7 November 2016
Resolved
Rewrite emergency procedures to reflect vessel's current arrangement and post them in a location available to passengers.
Due 7 December 2016
Resolved 28 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 November 2016
Resolved
Accurately label life jacket stowage for child-sized PFD's.
Due 7 December 2016
Resolved 28 November 2016
Engineering › Fuel Oil Service System › Hose
Issued 7 November 2016
Resolved
Reconnect fuel lines and add double hose clamps on port and stbd engines.
Due 7 December 2016
Resolved 28 November 2016
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 7 November 2016
Resolved
Replace in kind corroded bus bar behind steering console.
Due 7 December 2016
Resolved 28 November 2016
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 7 November 2016
Resolved
Replace in kind corroded bus bar in battery box and reattach broken grounding wire.
Due 7 December 2016
Resolved 28 November 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 November 2016
Resolved
Replace corroded fire extinguisher bracket located in port hull.
Due 7 December 2016
Resolved 28 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 May 2016
Resolved
No life jacket donning placard
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 31 May 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 May 2016
Resolved
Not present
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 May 2016
Resolved
not present
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Lifesaving › Lifebuoys › Immediately Available
Issued 27 May 2016
Resolved
retroreflective tape needs to be replaced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Communications › Audible Communications › Horn/Whistle
Issued 27 May 2016
Resolved
Missing
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 31 May 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 27 May 2016
Resolved
emergency broadcast placard missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 May 2016
Resolved
Not operational
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 May 2016
Resolved
not mounted
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 May 2016
Fire Fighting › Fire Bucket › Availability
Issued 27 May 2016
Resolved
Not on board
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 May 2016
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 May 2016
Resolved
Circuits not marked
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 May 2016
Stability › Watertight Integrity › Weathertight Enclosure
Issued 27 May 2016
Resolved
Hatch not watertight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 27 May 2016
Resolved
missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016