Records from 1988 to 2025. Most recent: inspection, 3 December 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 63
3 December 2025
Vessel Attendance · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8267745
21 May 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8141801
19 November 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8015853
10 October 2024
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7960145
14 February 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7865767
14 December 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7837673
15 December 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7605744
15 September 2022
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7546410
9 November 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7348437
4 June 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7215916
20 November 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7099441
4 November 2020
Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7090025
29 October 2019
COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6842488
21 August 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6795110
29 July 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6777481
16 April 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6669707
8 April 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6658472
12 February 2019
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6616445
16 May 2018
Internal Structural Exam · In-Service Inspection · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6416050
10 January 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6335238
7 November 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6046973
27 May 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5888770
12 April 2016
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5852926
28 August 2014
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4968363
1 August 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4102259
2 February 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3938209
5 March 2009
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3426646
31 October 2008
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3355292
6 May 2008
Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 3207391
15 January 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3135207
25 April 2007
Type not recorded
No type recorded · USCGC KITTIWAKE (WPB 87316) · USCG Oceania District (CGD-O) · Activity 2929402
13 September 2006
Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2777611
2 February 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2584338
17 November 2004
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2243233
19 August 2004
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2162237
30 July 2004
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2150820
11 April 2002
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1603778
27 September 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1074275
11 September 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1072899
5 July 2001
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431068
26 July 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373146
31 May 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369705
15 July 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393199
7 January 1999
Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 801979
23 December 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 807570
7 August 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1130692
6 August 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 796046
6 August 1998
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 796216
10 July 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1392948
20 May 1998
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378419
9 July 1997
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1114981
16 September 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1268560
15 May 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360519
1 May 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387958
28 February 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355676
23 July 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154308
10 December 1992
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1141869
9 December 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1257922
26 September 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1247726
11 October 1990
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1225456
12 June 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 915107
18 April 1989
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1352449
1 June 1988
COI Inspection · Plan Review "T" Boat · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341721
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical shock. The Emergency Switch for the battery installation located in the aft most container on deck was not secured to a bulkhead. Install breaker on a bulkhead to the satisfaction of the attending CG marine inspector. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 17 December 2025
Resolution: Emergency switch has been properly mounted. Picture uploaded under "documents" of this section.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2025
Resolved
The number and identification of the item stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The stowage locations for adult and children life jackets were not marked for identification, size, or number. Mark, in clearly legible letters, quantity of life jackets, and life jacket size (adult or child) to the satisfaction of the attending CG marine inspector. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 22 December 2025
Resolution: MI verified stowage and markings of life jackets, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 December 2025
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. None of the crew members on board had their marine radio operator permit on board. Provide a marine radio operator permit for a crew member to the satisfaction of the attending CG marine inspector. 47 CFR 80.159(e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 29 December 2025
Resolution: A copy of the permit was provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 November 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. (1) A space with a through-hull fitting below the deepest load waterline. Port stern compartment high level bilge alarm was inoperable. Vessel shall be operated with (1) additional deckhand while underway at all times until deficiency is rectified. Additional deckhand shall complete rounds of the port head space on at least 15 minute intervals. The deficiency shall be rectified within one week (11/26).
46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2024
Resolved 21 November 2024
Resolution: Recieved video and pictures from operator of operations bilge alarms.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 November 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Vessel was not maintaining drill log per regulatory standards. Future drill entries shall be made in accordance with appropriate regulation.
46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2024
Resolution: Conducted traning and witnessed proper drill entries after completing drills.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 November 2024
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have community service hot-line number displayed.
46 CFR 16.401
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2024
Resolved 21 November 2024
Resolution: Received photo from operator of posted hot-line number.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2023
Resolved
A submersible electric bilge pump may be used as power bilge pump required by Table 182.520(a), provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Installed (2) submersible bilge pumps are not UL 1113 rated. Install UL 1113 rated bilge pumps with appropriate overcurrent protection and demonstrate operation to attending marine inspector.
46 CFR 182.520(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2024
Resolved 8 January 2024
Resolution: Witnessed operation of newly installed (2) submersible pumps that are UL 1113 rated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Installed Blue Sea fuses (4) in battery compartment as well as fuse on port outboard battery are blade type. Replace blade type fuses with cartridge type fuses.
46 CFR 183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2024
Resolved 18 January 2024
Resolution: Vessel installed UL 489 breakers to replace blade-type fuses in Blue Sea system. See attached picture.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 December 2023
Resolved
Each hatch exposed to the weather must be watertight. Each hatch cover must have securing devices. Starboard aft hatch missing part of watertight gasket and securing device. Port and starboard forward hatches missing watertight gaskets. Install gasket and securing devices for starboard aft hatch. Install watertight gasket on port and starboard forward hatches.
46 CFR 177.13-1
46 CFR 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Visually verified watertight gaskets and appropriate latching devices have been installed on required hatches.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 December 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Captain's chair is mounted to a platform that is not secured to the deck nor is there any securing devices to prevent the chair from moving while the vessel is underway. Secure the chair and platform so they do not move while the vessel is underway.
46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Verifed supports were added on the deck to prevent Captain's chair from moving.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 December 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Paracord used to secure the deck netting on bow of vessel is unsuitable for supporting passengers. Replace paracord with line suitable for supporting deck nets and weight of passengers.
46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Verified new line was installed on netting. Line and netting are capable of supporting passengers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 December 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Bolt used to secure deck railing to bimini top structure on starboard side has failed at the weld. Replace hardware and reweld to the satisfaction of the attending marine inspector or install another suitable means to secure the deck railing to the bimini top structure.
46 CFR 176.800
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 8 January 2024
Resolution: Verified new weld was completed to secure deck railing and bimini top structure.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 December 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations including the requirement for maintaining current station installation certificates. The provided FCC Safety Radiotelephony Certificate was expired. Provide a valid FCC Safety Radiotelephony Certificate.
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2022
Resolved 20 December 2022
Resolution: FCC Safety Radiotelephony Certificate was provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 December 2022
Resolved
Each disposable hydrostatic release unit must replaced after having been in service for two years. The provided EPIRB disposable hydrostatic release was had passed it expiration date. Provide a new EPIRB hydrostatic release.
46 CFR 185.740
Action required: 10 - Deficiency Rectified
Resolved 15 December 2022
Resolution: A new disposable hydrostatic release for the EPRIB was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 November 2021
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC. The vessel's installation certificate was not current. Provide current, valid FCC safety certificate.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 29 November 2021
Resolution: A valid FCC Safety Certificate was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2020
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Four child size life jackets were not marked with appropriate retroreflective material. Provide appropriate markings to the satisfaction of the attending marine inspector. Child passenger count reduced to one.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 January 2021
Resolution: Attended vessel and witnessed newly installed retroreflective tape on all child size lifejackets.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 20 November 2020
Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed new operators valid MMC and medical certificate
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2020
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. The float switch on the starboard electric bilge pump is not secured, which prevents it from functioning properly. The float switch for the starboard electric bilge pump shall be secured to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed secured float switch.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 20 November 2020
Resolved
The master of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations. Garbage placard has been removed and shall be replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed installed garbage placard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 20 November 2020
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating Discharge of Oil Prohibited. The oil discharge placard has been removed and shall be replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed newly installed oil placard
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 20 November 2020
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessels emergency instructions are worn and unreadable. Replace emergency instructions poster.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed newly installed emergancy instructions
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 November 2020
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio is missing MMSI and LAT/LONG for DSC operation. Enter MSI and LAT/LONG into VHR radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed MMSI and GPS info in VHF radio
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 November 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The high level alarm for the starboard side did not provide visual indication. Repair or replace alarm to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed operational visual indicator on starboard high water alarm
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 November 2020
Resolved
All cable and wire must be installed with metal supports not more than 24 inches apart. The wiring for the port bilge pump is not properly supported and is laying in the bilge. Secure wire properly to the satisfaction of the attending USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed secured wires by port bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 20 November 2020
Resolved
At each initial and subsequent inspection for certification the marine inspector shall require all observed unsafe practices and hazardous situations be corrected. The vessels swim platform support brackets and supports are wasted beyond 25%. Submit repair proposal to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2021
Resolution: Attended vessel and witnessed repaired d-ring.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2020
Resolved
The Certificate of Inspection issued to a vessel describes the vessels minimum manning requirements and any equivalences accepted or authorized by the cognizant OCMI. The vessels Master does not hold a valid MMC due to incomplete medical certification. Vessel is required to be operated by, and shall not operate without, a Master holding a valid MMC with applicable endorsements as outlined by the vessels COI. Additionally, that Master shall possess knowledge of the vessel to include demonstrating emergency drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2021
Resolution: Attended vessel and witnessed new operators valid MMC and medical certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019
Resolved
Each ring life buoy on a vessel be approved in accordance with 46 CFR 160.050. Ring buoy grab line is falling apart, no name on the ring buoy and new battery for the floating waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2019
Resolved 12 November 2019
Resolution: New lifering with name, retroreflective tape and new battery for the floatinglight.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 30 October 2019
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2)
VHF radio missing MMSAI and LAT/LONG for DSC operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2019
Resolved 18 November 2019
Resolution: VHF radio had MMSI and LAT/LONG input.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. Supervisory personnel must receive at least 60 minutes of training. No Employee Assistance Program for licensed captain and crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 12 November 2019
Resolution: Information provided and training material reviewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019
Resolved
Conduct Chemical Testing Program Compliance Audit as required. No documentation of DAPI program requirements besides being enrolled in consortium.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2019
Resolved 13 November 2019
Resolution: Verified DAPI program and documentation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2019
Resolved
A vessel must carry either a first-aid kit, approved under approval series 160.041 or a kit with equivalent contents and instructions. Replaced expired medications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 12 November 2019
Resolution: Vessel provided new first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 October 2019
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 lbs. Deck rail are cracked in multiple locations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 12 November 2019
Resolution: All deck rails repaired.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 12 February 2019
Resolved
THE COMPASS MUST BE ILLUMINATED. COMPASS LIGHT WAS MISSING.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: New light installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 February 2019
Resolved
OPERATOR SHALL BE PREPARED TO CONDUCT TESTS AND HAVE VESSEL READY FOR INSPECTION OF THE HULL STRUCTURE AND ITS APPURTENANCES. AFT ALUMINUM HULL CROSS MEMBER SUPPORTING THE HYDRAULIC STEERING DRIVE HAVE OPENINGS ALLOWING INGRESS OF SEAWATER.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Hydraulic hoses properly supported and holes sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2019
Resolved
FLEXIBLE HOSE RUNS MUST BE VISIBLE, EASILY ACCESSIBLE, PROTECTED FROM DAMAGE. HYDRAULIC HOSE TO HYDRAULIC STEERING RAM NEEDS TO BE PROPERLY SUPPORTED TO PREVENT CHAFFING AND DAMAGE.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Hydraulic hoses properly supported with hose retainers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 February 2019
Resolved
VESSELS UNDER 65 FT IN LENGTH MUST MEET UL 1104 "STANDARDS FOR MARINE NAVIGATION LIGHTS." LENS FOR PORT, STBD AND STERN LIGHTS ARE FOGGED LIMITING REQUIRED ILLUMINATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: New working navigational lights installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2019
Resolved
A VISUAL INDICATOR MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE WHEN ANY AUTOMATIC BILGE PUMP IS OPERATING. WHEN STBD BILGE PUMP IS RUNNING IN AUTOMATIC BILGE PUMP MODE, NO INDICATION AT CONTROL CONSOLE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Alarm replaced and tested satisfactorily
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2019
Resolved
RECEPTACLE OUTLETS OF THE TYPE PROVIDING A GROUNDED POLE MUST BE OF A CONFIGURATION THAT WILL NOT PERMIT IMPROPER CONNNECTION. NON MARINE 110V RECEPTACLE AND WIRING CONNECTED TO INVERTER.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 12 March 2019
Resolution: Proper outlet with marine grade wiring installed.
Fire Fighting › Fire Bucket › Quantity
Issued 10 January 2018
Resolved
Provide three fire buckets IAW 46 CFR 181.610.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 10 January 2018
Resolution: Provided three fire buckets.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 January 2018
Resolved
Provide name of vessel on life ring IAW 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 10 January 2018
Resolution: Provided name of vessel on life ring.
Navigation › Piloting/Steering › Marine Charts
Issued 10 January 2018
Resolved
Provide updated navigation chart, current tables, tide tables, coast pilot, and light list IAW 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 10 January 2018
Resolution: Provided updated navigation chart, current tables, tide tables, coast pilot, and light list.
Engineering › Bilge Water Management System › Interface Detector
Issued 10 January 2018
Resolved
Prove proper operation of port and starboard bilge visual indicators IAW 46 CFR 182.530(c).
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Proved proper operation of port and starboard bilge visual indicators.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 January 2018
Resolved
Provide securing devices for each hatch on deck IAW 46 CFR 179.360.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Provided securing devices for all hatch on deck.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 January 2018
Resolved
Provide separate stowage of life jackets from additional personal flotation devices IAW 46 CFR 180.78(b).
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Provided separate stowage of life jackets from additional personal flotation devices.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 January 2018
Resolved
Provide one additional adult life vest IAW 46 CFR 180.71. Passenger count is reduced to 36 until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Provided one additional adult life vest. Passenger count is back to 37 IAW COI.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 January 2018
Resolved
Ensure life jackets match donning placard IAW 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 February 2018
Resolution: Installed life jacket donning placard that matches vest.
Communications › Radio Communications › EPIRB
Issued 7 November 2016
Resolved
Relocate EPIRB to float-free location.
Due 7 December 2016
Resolved 28 November 2016
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 7 November 2016
Resolved
Rewrite emergency procedures to reflect vessel's current arrangement and post them in a location available to passengers.
Due 7 December 2016
Resolved 28 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 November 2016
Resolved
Accurately label life jacket stowage for child-sized PFD's.
Due 7 December 2016
Resolved 28 November 2016
Engineering › Fuel Oil Service System › Hose
Issued 7 November 2016
Resolved
Reconnect fuel lines and add double hose clamps on port and stbd engines.
Due 7 December 2016
Resolved 28 November 2016
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 7 November 2016
Resolved
Replace in kind corroded bus bar behind steering console.
Due 7 December 2016
Resolved 28 November 2016
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 7 November 2016
Resolved
Replace in kind corroded bus bar in battery box and reattach broken grounding wire.
Due 7 December 2016
Resolved 28 November 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 November 2016
Resolved
Replace corroded fire extinguisher bracket located in port hull.
Due 7 December 2016
Resolved 28 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 May 2016
Resolved
No life jacket donning placard
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 31 May 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 May 2016
Resolved
Not present
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 May 2016
Resolved
not present
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Lifesaving › Lifebuoys › Immediately Available
Issued 27 May 2016
Resolved
retroreflective tape needs to be replaced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Communications › Audible Communications › Horn/Whistle
Issued 27 May 2016
Resolved
Missing
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 31 May 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 27 May 2016
Resolved
emergency broadcast placard missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 May 2016
Resolved
Not operational
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 May 2016
Resolved
not mounted
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 May 2016
Fire Fighting › Fire Bucket › Availability
Issued 27 May 2016
Resolved
Not on board
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 May 2016
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 May 2016
Resolved
Circuits not marked
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 May 2016
Stability › Watertight Integrity › Weathertight Enclosure
Issued 27 May 2016
Resolved
Hatch not watertight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 27 May 2016
Resolved
missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2016
Communications › Radio Communications › EPIRB
Issued 5 March 2009
Resolved
PROVIDE PROOF OF UPDATED EPIRB REGISTRATION.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: PROVIDED PROOF OF EPIRB REGISTRATION
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 5 March 2009
Resolved
PROVE PROPER OPERATION OF PORT SIDE HIGH WATER ALARM LIGHT.
Action required: 705 - Other - as specified
Due 5 April 2009
Resolved 6 April 2009
Resolution: Replaced wiring and proved proper operation of port high water alarm light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 March 2009
Resolved
PROVIDE UPDATED ITEMS TO FIRST AID KIT.
Action required: 705 - Other - as specified
Due 5 April 2009
Resolved 6 April 2009
Resolution: Provided replacement for all expired items.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 March 2009
Resolved
PROVIDE UPDATED LIGHT LIST.
Action required: 705 - Other - as specified
Due 5 April 2009
Resolved 6 April 2009
Resolution: Provided updated light list.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 5 March 2009
Resolved
PROVIDE RECENT LOCAL NOTICE TO MARINERS CHART UPDATES.
Action required: 705 - Other - as specified
Due 5 April 2009
Resolved 6 April 2009
Resolution: Recent local notice to mariners is on vessel.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 March 2009
Resolved
PROVIDE NEW RETRO-REFLECTIVE FOR LIFEJACKETS
Action required: 705 - Other - as specified
Due 5 April 2009
Resolved 6 April 2009
Resolution: Retro replaced on all required lifejackets.
Engineering › Steering Gear System › Rudder
Issued 5 March 2009
Resolved
REPLACE BOTTOM BRACKET ATTATCHMENT BOLTS FOR PORT AND STARBOARD RUDDERS. MAKE REPAIRS IF NECCESSARY.
Action required: 705 - Other - as specified
Due 5 April 2009
Resolved 6 April 2009
Resolution: Found crack in weld on stbd rudder. Made proper repairs. Replaced all 4 bolts on stbd side and 2 bolts on port side rudder attachment points.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 5 March 2009
Resolved
PROVIDE REQUESTED DOCUMENTATION FOR DAPI AUDIT.
Action required: 705 - Other - as specified
Due 5 April 2009
Resolved 17 April 2009
Resolution: Company rep provided all necessary drug audit paperwork. All sat.
Construction/Loadline › Structures › Superstructure
Issued 31 October 2008
Resolved
Make proper repairs to delaminated areas, port and stbd side of operators station.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Construction/Loadline › Hull › Side Shell
Issued 31 October 2008
Resolved
Make proper repairs to all gelcoat delaminated areas on exterior hull.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Construction/Loadline › Hull › Strut/Cross Tie
Issued 31 October 2008
Resolved
Replace wood brace holding stbd bow net in place.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Construction/Loadline › Structures › Superstructure
Issued 31 October 2008
Resolved
Replace port aft watertight hatch. Repair or replace all watertight hatch hardware.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Construction/Loadline › Structures › Superstructure
Issued 31 October 2008
Resolved
Replace both port and stbd inboard portholes.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Engineering › Steering Gear System › Linkage
Issued 31 October 2008
Resolved
Replace steering hardware from rudder post to hydraulic ram extension.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Resolution: Steering hardware renewed.
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 31 October 2008
Resolved
Repair both port and stbd outboard engine mounts.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Resolution: Engine mounts repaird.
Stability › Incline Test › General
Issued 31 October 2008
Resolved
Submit deadweight survey to Marine Safety Center in accordance with 46 CFR Subchapter S, Subpart F.
Due 15 December 2008
Resolved 30 June 2009
Resolution: USCG MSC issued new Stability Letter.
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 2 February 2006
Resolved
Fuel system placed in boxes that didn't provide either ventilation nor properly installed firefighting system.
Due 17 February 2006
Resolved 23 March 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 February 2006
Resolved
Required to show log showing proper maintenance as per 185.702
Condition: Unknown
Due 17 February 2006
Resolved 23 March 2006
Documentation › Certificates/Documents › FCC SSL
Issued 22 November 2004
Resolved
Provide FCC Safety Certificate.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided FCC safety certificate
Communications › Alarms/Indicators › High Water Alarm
Issued 17 November 2004
Resolved
Provide visual indicator for highwater light at operating station.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided operable visual indicator for highwater light at operating station.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 November 2004
Resolved
Provide x1 B-1 extinguisher.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided B-1 extinguisher.
Fire Fighting › Fire Bucket › Quantity
Issued 17 November 2004
Resolved
Provide x3 2.5 gal. fire buckets with markings & lanyards.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided x3 2.5 gal. fire buckets with markings & lanyards.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 17 November 2004
Resolved
Provide lifering with retroreflective tape, waterlight with 3 ft. lanyard & corrosion-clip.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided lifering with retroreflective tape, waterlight with 3 ft. lanyard & corrosion-clip.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 November 2004
Resolved
Provide NOAA registration sticker for EPIRB.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided NOAA registration sticker for EPIRB.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 November 2004
Resolved
Provide "emergency" marking for fuel shut off.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided "emergency" marking for fuel shut off.
Stability › Severe Wind/Roll › General
Issued 17 November 2004
Resolved
Provide rigging survey. Vessel not allowed to carry passengers while under sail.
Condition: Improper/Lack of Maintenance
Due 2 February 2006
Resolved 2 February 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 November 2004
Resolved
Make PORT / STBD collision bulkhead watertight.
Condition: Improper/Lack of Maintenance
Due 22 December 2004
Resolved 6 December 2004
Resolution: Provided PORT / STBD watertight collision bulkhead .
Stability › Severe Wind/Roll › General
Issued 17 November 2004
Resolved
Master to provide sail endorsement prior to "sailing" operations.
Condition: Improper/Lack of Maintenance
Due 2 February 2006
Resolved 2 February 2006
Construction/Loadline › Hull › Bracket
Issued 19 August 2004
Resolved
Provide survey of all rigging prior to operating the sails.
Due 22 November 2004
Resolved 2 February 2006
Lifesaving
Issued 5 July 2001
Resolved
PROVIDE PROOF OF NOAA REGISTRATION FOR EPIRB IAW 46CFR184.502 NLT 05AUG01.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Lifesaving
Issued 23 December 1998
Resolved
Prove presence of additional primary lifesaving equipment and personal floatation devices for 6 additional persons allowed to the satisfaction of the attending marine inspector. This is in response to the operator's request to increase persons allowed to 32 in a letter dated Dec 1, 1998.
Condition: Unknown
Due 28 December 1998
Resolved 28 December 1998
Engineering
Issued 10 July 1998
Resolved
Effect repairs and prove operation of port outboard engine.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 10 July 1998
Resolved
Effect repairs to overhead lighting in both accomodation spaces.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Documentation
Issued 10 July 1998
Resolved
Provide evidence of a valid FCC safety radio certificate.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Construction/Loadline
Issued 20 May 1998
Resolved
Renew hatch cover chains where missing or corroded.
Condition: Unknown
Due 30 June 1998
Resolved 3 August 1998
Construction/Loadline
Issued 20 May 1998
Resolved
Renew aft port butt block for cleat.
Condition: Unknown
Due 30 June 1998
Resolved 3 August 1998
Construction/Loadline
Issued 20 May 1998
Resolved
Reglass frame in port pontoon, located in the center compartment, on the aftermost frame.
Condition: Unknown
Due 30 June 1998
Resolved 3 August 1998
Deck/Cargo
Issued 20 May 1998
Resolved
Install cotter pins in rigging where missing or worn.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Construction/Loadline
Issued 20 May 1998
Resolved
Properly secure port and stbd bilge pump wiring within junction boxes.
Condition: Unknown
Due 30 June 1998
Resolved 3 August 1998
Documentation
Issued 15 May 1996
Resolved
Provide proof of application for FCC Safety Certificate.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Electrical
Issued 1 May 1996
Resolved
Prove operation of the compass light in accordance with 46 CFR 184.402.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Electrical
Issued 1 May 1996
Resolved
INSTALL COVER ON OVERHEAD LIGHT FIXTURE, LOCATED ON CABIN TOP OVERHEAD.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Navigation
Issued 1 May 1996
Resolved
Renew in kind the hydraulic flexible hoses connected to the steering ram.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Electrical
Issued 1 May 1996
Resolved
PROVE OPERATION OF OVERHEAD LIGHT FIXTURES IN BOTH ACCOMODATION SPACES.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE PROOF OF APPLICATION OF FCC SAFETY CERTIFICATION.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Electrical
Issued 1 May 1996
Resolved
Provide portable lights in accordance with 46 CFR 183.430.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Conduct and log crew training in accordance with 46 CFR 185.420.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Navigation
Issued 1 May 1996
Resolved
Post a radio emergency broadcast placard in accordance with 46 CFR 184.506.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Post PFD placards in accordance with 46 CFR 185.516.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Provide passenger count lists in accordance with 46 CFR 185.504.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Conduct passenger safety orientation in accordance with 46 CFR 185.506.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE PROOF OF 60 MINUTE SUPERVISOR TRAINING.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Conduct and log abandon ship and man overboard drills and training in accordance with 46 CFR 185.520.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Fire Fighting
Issued 1 May 1996
Resolved
Conduct and log fire fighting drills and training in accordance with 46 CFR185.524.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Properly label all lifesaving equipment in accordance with 46 CFR 185.604.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Install retroreflective tape on the life ring buoy in accordance with 46 CFR 185.604(i).
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Accommodation/Occupational Safety
Issued 1 May 1996
Resolved
Properly label emergency escape hatches and emergency exits in accordance with 46 CFR 185.606.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
Properly label watertight hatches in accordance with 46 CFR 185.610.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Provide a suitable watertight container for the distress signals in accordance with 46 CFR 185.614.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Provide manufacturer maintenance instructions for the survival craft in accordance with 46 CFR 185.702.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Conduct and log weekly maintenance and inspection of the survival craft in accordance with 46 CFR 185.720.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 1 May 1996
Resolved
Conduct and log monthly inspection of the survival craft in accordance with46 CFR 185.722.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Deck/Cargo
Issued 1 May 1996
Resolved
PROPERLY RIG VESSEL WITH SAILS AND PROVE UNDERWAY OPERATION IN THE PRESCENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 28 February 1996
Resolved
Make trampoline available for inspection.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 28 February 1996
Resolved
Renew port forward hatch coaming.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Deck/Cargo
Issued 28 February 1996
Resolved
Properly mouse anchor chain shackles.
Condition: Unknown
Due 30 March 1996
Resolved 30 March 1996
Navigation
Issued 28 February 1996
Resolved
Make steering hydraulic lines/fittings available for inspection.
Condition: Unknown
Due 30 March 1996
Resolved 30 March 1996
Lifesaving
Issued 28 February 1996
Resolved
Renew reflective tape for the buoyant apparatus and lifefloat.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 28 February 1996
Resolved
Renew or repair as original stern cross member where holed.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Accommodation/Occupational Safety
Issued 28 February 1996
Resolved
Make repairs to rail aft of passenger access port and starboard side. (Top rail and post have separated).
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 28 February 1996
Resolved
Make all hatches exposed to weather watertight with securing devices and beattached by hinges, captive chains or other device to prevent its loss. Vessel restricted to protected waters as defined by 46 CFR 170.050(j) untilcorrected.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 28 February 1996
Resolved
Make chain plates and chain plate fasteners available for inspection.
Condition: Unknown
Due 30 March 1996
Resolved 30 March 1996
Construction/Loadline
Issued 28 February 1996
Resolved
Submit for approval plans for modifications to bring the bilge system into compliance with the regulations.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 28 February 1996
Resolved
Install bilge system in accordance with the approved plans.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 28 February 1996
Resolved
Renew starboard forward hatch cover.
Condition: Unknown
Due 30 March 1996
Resolved 30 March 1996
Lifesaving
Issued 28 February 1996
Resolved
Provide pendants, 18 inches apart, 12 feet long secured in the middle, madeup in a hank IAW 46 CFR 160.010.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996