MAURY USCG vessel records
← All vessels

CHABLIS

Built
1990
Last inspected
29 April 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH6250
314409
Flag
UNITED STATES
Maury page id
psix-314409

Documentation record

Registered dimensions (L × B × D)48.2 ft × 23.8 ft × 4.0 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUMBOLDT BELLE INC · FIELDS LANDING, CA, UNITED STATES · built 1990
Hull materialWood
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portMORRO BAY, CA
Endorsements, as the file codes themcw_un, rec, reg
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Gross Ton
30 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 66 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

29 April 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8127446
25 April 2024 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7902215
23 February 2024 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7867884
5 April 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7636209
5 April 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7418351
17 February 2022 In-Service Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7396182
21 June 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7189430
24 May 2021 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7205667
23 May 2021 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7205817
16 February 2021 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7140147
22 June 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6973344
11 June 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6683923
21 February 2019 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6629178
9 July 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6475993
9 October 2017 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6284314
8 October 2017 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6284240
10 April 2017 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6114522
12 January 2017 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6069631
15 June 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5900354
5 June 2016 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5900300

Deficiency record · 66

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2025 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Wiring for the Fireboy and lighting in the machinery space overhead IWO the center beam is not secure. Install metal supports at least every 24 inches to prevent damage and mitigate fire/safety hazards. 46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 18 August 2025
Resolution: Verified wiring was properly secured to overhead beam.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 29 April 2025 Resolved
The marine employer must have a sufficient number of alcohol testing devi es readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol test strips were expired. Provide testing devices for total crew onboard. 46 CFR 4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 29 April 2025
Resolution: New testing devices ordered and will be delivered prior to next trip.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 April 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Items in kit were expired/ missing. Make kit in compliance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 10 May 2023
Resolution: Made kit in compliance with regulations.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 April 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Post all required documents as required by regulation and to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 1 June 2023
Resolution: Posted all required documents as per regulation and to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2023 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in sub-chapter Q of 46 CFR, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. 01 life buoy grab-line was wasted. Make grab line satisfactory
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 10 May 2023
Resolution: Made grab line satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2023 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of 46 CFR, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlight is not of the approved type. Replace current unauthorized waterlight with correct type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 10 May 2023
Resolution: Replaced unauthorized waterlight with correct type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 April 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel's propulsion main engine began overheating while underway, forcing vessel to anchor and shutdown engine. Vessel must diagnose and submit diagnosis and repair to the USCG and perform underway operational test to the satisfaction of an attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2022
Resolution: Vessel removed air from raw water intake and performed satisfactory underway operational test. attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 April 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Vessel was not able to dewater engine room bilge or mid-ship bilge with installed bilge system. Make bilge system in compliance with regulations and to satisfaction of attending Marine Inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2022
Resolution: Made bilge system in compliance with regulations and to satisfaction of attending Marine Inspector
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 April 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation (COD) currently in effect for that vessel. Vessel did not have valid COD on board. Provide proof of valid COD to attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: Provided proof of valid COD to attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 April 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Items in kit were expired/ missing. Make kit in compliance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2022
Resolution: Made kit in compliance with regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Child size life jackets were stowed with adult life jackets. Containers for life jackets were not correctly marked. Make containers and stowage as required by regulation and attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2022
Resolution: Made containers and stowage as required by regulation and attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2022 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of 46 CFR. Waterlight had incorrect type battery. Replace battery as per manufacturer requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2022
Resolution: Replaced battery as per manufacturer requirements.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electronic control panel under helm broken. Repair broken control panel to satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2022
Resolution: Repaired broken control panel to satisfaction of attending Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 April 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessel is only allowed 56 passengers on its upper deck, but is marked for 65. Correct markings as required and to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2022
Resolution: Corrected markings as required and to the satisfaction of attending Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 April 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Post all required documents as required by regulation and to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2022
Resolution: Posted all required documents as required by regulation and to the satisfaction of the attending Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 March 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously. Rails on upper weatherdeck were not yet fully installed and required hot work. Repair/replace rails to satisfaction of attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 March 2022
Resolution: Repaired rails to satisfaction of attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 March 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Lighting around wheelhouse was in disrepair and an electrical hazard. Remove/make lighting in compliance with regulations to satisfaction of attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 March 2022
Resolution: Made lighting in compliance with regulations to satisfaction of attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2022 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Wheelhouse was not yet made weathertight after dry-docking. Make weathertight with good marine practice as required by the regulation and to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 March 2022
Resolution: Wheelhouse made weathertight with good marine practice as required by the regulation and to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 June 2021 Resolved
Remove paint stored below decks or provide paint locker.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 29 July 2021
Resolution: Vessel removed excess paint and hazardous supplies.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 June 2021 Resolved
Provide alcohol testing devices.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 24 September 2021
Resolution: Vessel sent pictures of provided alcohol test strips.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2021 Resolved
Fire hose leaking. Deonstrate proper operation of fire hose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 19 August 2021
Resolution: Vessel purchased new fire hose.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 June 2020 Resolved
First aid kit contained expired items. Provide current and complete first aid kit that meets 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 21 July 2020
Resolution: Vessel provided replacement items.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 June 2020 Resolved
Fire drills and abandon ship drills were not logged. Log drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 21 July 2020
Resolution: Vessel provided logs showing completion of drills.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2020 Resolved
Plastic (combustible) garbage can found behind bar. Remove combustible garage receptacles from accommodation spaces.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 21 July 2020
Resolution: Vessel replaced trash can with a metallic one.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 July 2018 Resolved
Renew COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 16 July 2018
Resolution: New COD issued
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2018 Resolved
Provide 7 additional adult lifejackets for a total of 98; vessel restricted to 91 passengers until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 22 August 2018
Resolution: O/O decided to not provide additional lifejackets and reduce passenger count; amended COI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2018 Resolved
Provide 04 servicable fire extinguishers and provide service report prior to operating with passengers.
Action required: 10 - Deficiency Rectified
Due 9 July 2018
Resolved 9 July 2018
Resolution: Fire extinguishers were serviced same day.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 July 2018 Resolved
Post stability letter at operating station.
Action required: 10 - Deficiency Rectified
Due 9 August 2018
Resolved 9 July 2018
Resolution: Stability letter posted on the same day.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2018 Resolved
Properly mark lifejacket storage with proper count.
Action required: 10 - Deficiency Rectified
Due 9 August 2018
Resolved 9 July 2018
Resolution: Lifejacket storage marked on the same day.
Engineering › Steering Gear System › Rudder
Issued 9 October 2017 Resolved
Make vessel available for dockside & underway inspection of hull and steering gear by a USCG Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2017
Resolved 19 October 2017
Resolution: No sign of damage to hull; repaired rudder tested underway, all sat.
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 10 April 2017 Resolved
Properly rig ring buoy, line and electric waterlight, and place on station.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 11 April 2017
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 10 April 2017 Resolved
Prove proper operation of waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 10 April 2017
Engineering › Bilge Water Management System › Pump
Issued 10 April 2017 Resolved
Securely mount the lazarette high bilge alarm float switch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Fire Fighting › Fire Pumps › Pressure
Issued 10 April 2017 Resolved
Troubleshoot fire pump to improve pressure/water flow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 10 April 2017 Resolved
Display EAP info & 800 hotline number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 April 2017 Resolved
Provide company drug policy info.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 April 2017 Resolved
Repair anchor light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 April 2017 Resolved
Provide log of drills/training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Documentation › Certificates/Documents › Stability Letter
Issued 10 April 2017 Resolved
Post stability letter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 January 2017 Resolved
Thoroughly clean E/R bilge and remove standing water.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Engineering › Bilge Water Management System › Piping
Issued 12 January 2017 Resolved
E/R: Fwd bilge pipe inboard – clean with wire brush & inspect
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Construction/Loadline › Hull › Side Shell
Issued 12 January 2017 Resolved
Port & stbd sewage compt: address weeping aft overhead/bulkhead seam
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Construction/Loadline › Hull › Side Shell
Issued 12 January 2017 Resolved
Port aft sideshell: submit plans for sideshell repair (impact damage)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 12 January 2017 Resolved
MDE starting battery circuit: replace cartridge fuse breaker with appropriate circuit breaker.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 10 April 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 January 2017 Resolved
Reefer room: remove power strip and install accessible receptacle
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Construction/Loadline › Hull › Side Shell
Issued 12 January 2017 Resolved
Repair decayed plywood at port transom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 12 January 2017 Resolved
Remove/replace inboard pipe for generator keel cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 12 January 2017 Resolved
Cap unused penetration of port fwd bulkhead in void under salon
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 January 2017 Resolved
Remove dead-end wire in #2 void
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Construction/Loadline › Hull › Side Shell
Issued 12 January 2017 Resolved
Dry/treat decayed plywood in #2 void, stbd side
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 10 April 2017
Stability › Watertight Integrity › General
Issued 12 January 2017 Resolved
Locate/repair water leak (from exterior) in #2 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Engineering › Steering Gear System › Rudder Stock
Issued 12 January 2017 Resolved
Repair or replace bent rudder stock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2017 Resolved
Complete post-drydock check-ride
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 23 February 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 June 2016 Resolved
Re-wrap generator exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 June 2016 Resolved
Stabilize E/R deck board (port side).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Engineering › Steering Gear System › Piping
Issued 15 June 2016 Resolved
Laz: Replace crimped copper line and check all fittings for weeps.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Engineering › Steering Gear System › Pin
Issued 15 June 2016 Resolved
Install chafing gear on steering hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 15 June 2016 Resolved
Install blanks on shore power box (3 total)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 June 2016 Resolved
Bar: Repair receptacle near fridge, and secure wires entering junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 15 June 2016 Resolved
Remove flammables (paints, epoxies) from vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 15 June 2016 Resolved
Post EAP 800 #
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 June 2016 Resolved
Service f/f equipment
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 15 June 2016 Resolved
Secure engine mounts to engine bed to prevent engine movement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 21 July 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 June 2016 Resolved
Attach 60-ft of line and electric waterlight to ring buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Construction/Loadline › Hull › Side Shell
Issued 6 June 2016 Resolved
Make in-kind repairs to port side boarding door jamb and window frames.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 9 June 2016
Construction/Loadline › Hull › Side Shell
Issued 5 June 2016 Resolved
Vessel may not operate with passengers until a USCG MI has attended the vessel to conduct a damage survey, and any required repairs are completed to the satisfaction of the attending USCG MI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 6 June 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.