Records from 2016 to 2026. Most recent: inspection, 4 June 2026.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 14.0 ft × 5.0 ft
Registered tonnagegross 62 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWATERHOUSE CRUISERS INC · MUNCIE, IN, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUGHTON, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 29 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
4 June 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8391045
4 August 2025
Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8188117
14 August 2024
Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7981370
2 May 2024
Examination of Repairs
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7905994
2 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7877740
23 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7694906
10 May 2022
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7448249
25 May 2021
COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7201147
9 July 2020
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7001994
28 August 2019
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6797452
30 October 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6571137
28 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6458837
3 August 2017
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6177944
31 May 2016
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5876468
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 August 2025
Resolved
Each U.S. flag vessel of less than 38 meters (124 feet) in length while subject to this subpart must have a radiotelephone meeting the provisions of this subpart in addition to the other rules in this part governing ship stations using telephony. Each U.S. flag vessel subject to this subpart must have an inspection of the required radiotelephone installation at least once every 48 months. This inspection must be made while the vessel is in active service or within not more than one month before the date on which it is placed in service.
Vessel did not have a radiotelephone certificate or any proof of proper installation of the radiotelephone onboard.
47 CFR 80.955(a)
47 CFR 80.953(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 10 September 2025
Resolution: Vessel received a radio telephone cert for great lakes use.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2022
Resolved
Vessels must have 2 independent means of shutting down the engines. Operator did not know if exercising the fuel shutoff valves would shutdown the engine. Provide proof that exercising the fuel shutoff valves will shutdown the engines
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 11 May 2022
Resolution: Diesel mechanic attended vessel and applied lubircant to the fuel shutoff valves. Mechanic exercised the fuel shutoff valves and the engines shut down.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 May 2022
Resolved
Fuel hose on generator must meet SAE J-1942 standards. When originally installed, met SAE J-1942, but has deteriorated over the years rendering the generator inoperable. Replace fuel line with new SAE J-1942 fuel line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 11 May 2022
Resolution: Diesel mechanic attended vessel and replaced old fuel lines with new SAE J-1942 fuel lines.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 May 2021
Resolved
071020 - Recharge or replace if the pressure loss exceeds 10 percent. The vessel's halon system was 50% charged at the time of inspection. Have system serviced through a qualified technician and provide proof of service the to local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2022
Resolution: Technician attended vessel and replaced system. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2021
Resolved
02199 - Inspect all railings and bulwarks and their attachment to the hull structure. The fiberglass at the installation points of the deckrails on the top deck are wasted and the hand rails are loose. Install handrails to ensure secure attachment to the hull.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2022
Resolution: Owner replaced all railings and bulwarks and their attachments to the hull structure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2018
Resolved
Installed outlet in head is not a GFCI. Needs to be a GFCI. Also 1 switch and 2 outlets in the galley need cover plates.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2018
Resolved 20 July 2018
Resolution: outlet covers replaced and GFCI installed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 August 2017
Resolved
label adult/child lifejacket stowage for those kept in the wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2017
Resolved 5 September 2017
Resolution: Stowage has been marked properly.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 August 2017
Resolved
Mount all fire extinguishers in brackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2017
Resolved 5 September 2017
Resolution: fire extinguishers have been mounted in brackets
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 3 August 2017
Resolved
provide appropriate amount/sizes of fire extinguishers per the COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2017
Resolved 5 September 2017
Resolution: owner has sufficient amount of fire extinguishers.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 August 2017
Resolved
Repair broken weld on starboard bow hand rail.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2017
Resolved 5 September 2017
Resolution: railing has been welded.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 August 2017
Resolved
Fix engine compartment bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 3 August 2017
Resolution: Rcvd video evidence of alarm activating
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 August 2017
Resolved
Cover the battery in the engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2017
Resolved 5 September 2017
Resolution: battery now has a cover.