Records from 2016 to 2026. Most recent: inspection, 9 June 2026.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 June 2024
Resolved
COD not onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 12 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2024
Resolved
Electrical- Vessel has dead end wires that need to be removed from port bilge. Main deck refrigerator needs permanent outlet installed. Marine radio in stbd fwd cabin has speaker wire running to it as 12v power wire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 22 August 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 June 2024
Resolved
Captain's Medical Certificate not onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 29 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2024
Resolved
Liferings are not CG approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 29 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2023
Resolved
Found an extension cord routed through an old electrical access being used to power the bar area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 13 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2023
Resolved
Found both liferings heavily UV damaged and in need of replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 13 September 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 20 June 2023
Resolved
Found one high water alarm not functioning.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 13 September 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2022
Resolved
Port sponson bilge alarm functions but is barely audible, must be made functional.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 28 July 2022
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2022
Resolved
Large life jacket container on port side of main deck must be properly labeled and have donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 28 July 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2022
Resolved
Both gas tank vents must have 30x30 flame screen installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 28 July 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2022
Resolved
Batteries need chocks and covers. Starboard battery area must have all the alcohol removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 28 July 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2021
Resolved
Label fire buckets appropriately "FIRE BUCKET".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 19 July 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2021
Resolved
Portable fire extinguishers need to be mounted in the correct manufacturers recommended brackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 19 July 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2021
Resolved
Type I PFDs need to be labeled with the name of the vessel in clearly legible block lettering.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 19 July 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2021
Resolved
Each ring life buoy must be marked with retro reflective material of sufficient width, 2 in. should be applied around or on both sides of the body of the life buoy at 4 evenly spaced points.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 19 July 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2021
Resolved
Each floating waterlight on a vessel must be attached to the lanyard with a corrosive resistant clip. Currently the light has alkaline batteries. The model of light carried onboard this vessel is only authorized with lithium AA batteries. Change batteries to lithium.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 19 July 2021
Resolution: cORRECTED.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 June 2021
Resolved
Stability letter is required to be posted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 19 July 2021
Resolution: Corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 15 June 2021
Resolved
Port sponson has been deemed inaccessible to passengers forward of the head by the Captain of the vessel. Employ a lanyard and signage to reflect crew only beyond this point.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 19 July 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 June 2020
Resolved
properly mark RLB with vessel name
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 25 June 2020
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 June 2020
Resolved
replace missing electrical outlet cover - port sponson, fwd compartment, inboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 25 June 2020
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 22 July 2019
Resolved
Vessel port and starboard bows must be clearly marked with the vessel name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 18 September 2019
Resolution: Corrected
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 22 July 2019
Resolved
Stability letter (or a copy of) must be posted at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 18 September 2019
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2019
Resolved
Port sponson adult PFD stowage must be properly marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 18 September 2019
Resolution: Corrected
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 July 2019
Resolved
Starboard side bilge alarm light is inop, repair and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 18 September 2019
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2019
Resolved
Starting batteries need to be secured to protect against shifting within the engine space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 18 September 2019
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 26 June 2018
Resolved
Post emergency instructions at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 June 2018
Resolved
Post no smoking signs.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 June 2018
Resolved
Properly label emergency fuel shutoff valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2018
Resolved
Replace 1 missing 2.5 gallon fire bucket and install line on 2 buckets. Buckets must be marked with the words "FIRE BUCKET" in a contrasting color.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 June 2018
Resolved
Coast pilot & light list must be updated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2018
Resolved
All batteries must be properly chocked to protect against shifting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2018
Resolved
Starting batteries must be properly secured to protect against shifting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2018
Resolved
Properly secure fuel filter lines in engine compartments.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 June 2018
Resolved
Complete temporary repairs to stbd sponson access hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 30 July 2018
Resolution: Received photo evidence and e-mail attesting to full compliance.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 June 2018
Resolved
Complete permanent repairs to stbd sponson access hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 22 May 2019
Resolution: repaired.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 8 June 2017
Resolved
Post no smoking signage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 21 June 2017
Resolution: posted.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 8 June 2017
Resolved
Post EPs at operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 21 June 2017
Resolution: posted.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 June 2017
Resolved
Properly mark emergency fuel shut-off valves.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 21 June 2017
Resolution: marked.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 June 2017
Resolved
Post PFD donning placard in child PFD cabinets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 21 June 2017
Resolution: posted.
Lifesaving › Lifebuoys › Size
Issued 8 June 2017
Resolved
Replace 20 inch RLB with proper size and properly marked/outfitted/mounted RLB.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: completed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 8 June 2017
Resolved
properly chock gas tanks and batteries
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 21 June 2017
Resolution: chocked both gas tanks and all batteries
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 8 June 2017
Resolved
replace combustible trash cans with non-combustible type
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: replaced
Navigation › Piloting/Steering › Marine Charts
Issued 8 June 2017
Resolved
replace outdated charts and Nav Rules
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 21 June 2017
Resolution: replaced
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 June 2017
Resolved
properly mount portable fire extinguishers with appropriate marine type brackets
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: mounted
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 June 2017
Resolved
properly display EAP info
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 21 June 2017
Resolution: posted
Construction/Loadline › Hull › Side Shell
Issued 12 May 2016
Resolved
Rotten wood found on shelf forward of port side chainstay and in way of stern port side chainstay. Provide repair plan to [name withheld] accepted make all repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2016
Resolution: Received acceptable plan.
Construction/Loadline › Structures › Deck Plating
Issued 12 May 2016
Resolved
Make permanent repairs to damage in the following areas:
a. Starboard bow and cross beam to hull connection
b. port hull, forward of chain plate connection
c. port aft cleat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 24 June 2016
Resolution: made repairs as per their accepted plan
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 12 May 2016
Resolved
Remove rust and paint 3 fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 18 May 2016
Resolution: replaced with new
Sail Rigging › Running Rigging › Shackles
Issued 12 May 2016
Resolved
replace bent shackle for jib clew
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 18 May 2016
Resolution: replaced with new
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 12 May 2016
Resolved
Repalce netting in bow sprit. Permitted to carry passengers in all other areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 18 May 2016
Resolution: replaced with new
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2016
Resolved
Replace conductors for horn. Reduce connections and use crimp type connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 18 May 2016
Resolution: rewired, reduced to two fewer connections, used crimp type connectors.