MAURY USCG vessel records Sign in
← All vessels

LOVE

LOVE is a 1962 freight ship. The Coast Guard has recorded 12 inspections since 1988, most recently in September 1998, along with 73 deficiencies and 1 operational control.

Records from 1988 to 1998. Most recent: inspection, 2 September 1998.

Built
1962
Last inspected
2 September 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5251109 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
314708
Flag
PANAMA
—
Maury page id
psix-314708

Inspections, by type

…with no type recorded11
Years with a record 6 calendar years (1988–1998)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it738 - Regulatory (Subpart C or D), Gross Ton
269 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

2 September 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 420216
9 July 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 393093
12 March 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 390068
11 December 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 158598
11 January 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 847290
5 September 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 679625
6 August 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942332
20 July 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 940132
15 December 1990 Uninspected Other
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 901785
5 December 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1212685
4 December 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 341538
9 August 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 325079

Deficiency record · 73

Fire Fighting
Issued 12 March 1996 Resolved
Many of the portable fire extinguishers are empty and the vessel does not have the required spare charges.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
For the route and service intended by this vessel, lifeboats are not provided for both port and starboard sides of the vessel. Each of these life boats shall be attached to davits and shall accomodate all persons on board. SOLAS 48, CH III, Reg 32
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 12 March 1996 Resolved
The blkhd dk & dks above are not wtrtght. Hatches & doors for personnel access are wstd and will not dog tight. Holes are apparent at the fwd end of the house aft of #2 hold. The aft focsle is wstd and has no covers for cargo hold ventilation.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 12 March 1996 Resolved
The stateroom portlights below the main deck are missing the dead light covers.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 12 March 1996 Resolved
The strength moduli of the main deck, area around the cargo hatches, and cargo lifting "King Posts" are beyond the safety
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 12 March 1996 Resolved
The upper decks are wasted and covered by 2" of concrete.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Documentation
Issued 12 March 1996 Resolved
Stability test and loading information is not available on the vessel for the master.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Electrical
Issued 12 March 1996 Resolved
Vessel does not have sufficient emergency battery power for the required 36hours of emergency power.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 12 March 1996 Resolved
The skin valves throughout the vessel are missing valve handles.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Fire Fighting
Issued 12 March 1996 Resolved
The engine room fire pump is not capable of producing at least two powerfuljets of which the throw at any nozzle shall be at least 40 feet. The electrial equipment for the pump is in such dilapidated condition that the pump will not run unattended.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Fire Fighting
Issued 12 March 1996 Resolved
vessel does not have two complete fireman's outfits.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Lifesaving
Issued 12 March 1996 Resolved
Vessel does not have a Shipboard Oil Pollution Emergency Plan.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Construction/Loadline
Issued 12 March 1996 Resolved
The 100 PPM oily water separator is inoperative.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Electrical
Issued 12 March 1996 Resolved
Vessel has loose exposed wiring, broken exposed light bulbs, the fire pump motor controller is held in the open position with a manila line, and the fire pump motor windings/mommutator has no guard which leaves it open to water and falling debris.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Documentation
Issued 12 March 1996 Resolved
Vessel shall be manned in accordance with safe manning certificate.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Documentation
Issued 12 March 1996 Resolved
Vessel operators have no training certificates which are applicable to a vessel between 200 and 1600 gross tons.
Condition: Unknown
Due 9 September 1999
Resolved 26 October 1998
Fire Fighting
Issued 12 March 1996 Resolved
Muster list and emergency instructions are not available.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
No emergency lighting is available at the embarkation stations for the liferafts.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Accommodation/Occupational Safety
Issued 12 March 1996 Resolved
The sewage holding has inadequate holding capacity.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Navigation
Issued 12 March 1996 Resolved
Vessel has no pilot ladder or lighting arrangements.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 12 March 1996 Resolved
Vessel does not have two power bilge pumps which are connected to the main bilge system.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
Vessel has no line-throwing appliance of a type approved by the Administration.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
Flammable liquids and paints are stored in the fo'c's'le which is not approved nor is a fixed fire fighting system supplied.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Navigation
Issued 12 March 1996 Resolved
Steering gear motor is not operable. No low-level alarm is provided for thehydraulic fluid reservoir and no fixed storage tank for recharging the reservoir.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
The port life raft is not stowed so that it will release and inflate in theevent the ship sinks.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 12 March 1996 Resolved
Vessel is not watertight or smoke tight between the #2 cargo hold and the engine room.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Navigation
Issued 12 March 1996 Resolved
Vessel does not have the two required radar transponders.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
The vessel does not have immersion suits and thermal protective aids.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
Vessel does not have 12 parachute flares.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 12 March 1996 Resolved
Vessel does not have training manual complying with Regulation 51.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Navigation
Issued 12 March 1996 Resolved
Vessel has no means for taking a bearing over a 360 degree horizon.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Navigation
Issued 12 March 1996 Resolved
Vessel does not fully comply with radio communication requirements in forceprior to 1 February 1992.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Documentation
Issued 12 March 1996 Resolved
Crew licenses or documents not issued under the authority of the Administration or recognized by the Administration.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO THE AFT OVERHEAD TO THE SATISFACTION OF THE COGNIZANT OCMI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO PLUMBING IN THE CREWS WASHROOM AND LAUNDRY ROOM PRIOR TO RETURN TO A U.S. PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO THE GALLEY REFRIGERATION SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO WASTED AREAS IN WAY OF THE STEEL DECK ABOVE CREWSQUARTERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO WASTED DECK IN CREWS QUARTERS PRIOR TO RETURN TO A U.S. PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO WASTED MAIN DECK PASSAGEWAY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Construction/Loadline
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO THE AFT WASTED AREAS IN THE DECK HOUSE'S AFTER BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Construction/Loadline
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO WASTED AREAS IN WAY OF THE FORECASTLE AFTER BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Construction/Loadline
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO WASTED AREAS IN WAY OF THE PART HAWSEPIPE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Construction/Loadline
Issued 15 December 1990 Resolved
INSTALL STARBOARD ANCHOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
INSTALL AND REPAIR ALL LIFE RAILS PRIOR TO RETURN TO A U.S. PORT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO THE WASTED AREAS OF THE ENGINE ROOM VENTILATION DUCTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO CREW'S WATER CLOSET BULKHEADS PRIOR TO RETURN TO A U.S. PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
INSTALL WATER SUPPLY LINE TO CREWS TOILET._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Lifesaving
Issued 15 December 1990 Resolved
SUPPLY EACH CREW MEMBER WITH THE APPROPRIATE TYPE OF PFD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Electrical
Issued 15 December 1990 Resolved
INSTALL LIGHT BULBS IN ALL LIGHT FIXTURES._x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Lifesaving
Issued 15 December 1990 Resolved
PROFESSIONALLY SERVICE AND PROPERLY INSTALL ALL LIFERAFTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Accommodation/Occupational Safety
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO DAMAGED STAIRBOARD STAIRS TO THE FORECASTLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Construction/Loadline
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO THE WEATHER DECK OF THE FORECASTLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Fire Fighting
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO THE FIREMAIN WHICH HAS BEEN SHEARED OFF AT THE FRONT OF CARGO HATCH NUMBER ONE PORT SIDE.
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Fire Fighting
Issued 15 December 1990 Resolved
PROVE PROPER OPERATION OF THE SHIP'S MAIN FIRE PUMP.
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Fire Fighting
Issued 15 December 1990 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Navigation
Issued 15 December 1990 Resolved
PROVE PROPER OPERATION OF EMERGENCY STEERING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Engineering
Issued 15 December 1990 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Navigation
Issued 15 December 1990 Resolved
PROVE PROPER OPERATION OF THE MARINE NAVIGATION RADAR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Lifesaving
Issued 15 December 1990 Resolved
INSTALL LAUNCHING EQUIPMENT AND PROVE PROPER OPERATION OF EQUIPMENT FOR THERESCUE BOAT.
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Electrical
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO ELECTRICAL BOX AND REPLACE WIRING TO BOX LOCATED IN ENGINE ROOM, STARBOARD SIDE LOWER LEVEL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Electrical
Issued 15 December 1990 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD GENERATOR ON THE LOWER LEVEL PRIOR TO RETURN TO A U.S. PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 15 December 1990 Resolved
INSTALL FIRE HOSES AT ALL FIRE FIGHTING STATIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Electrical
Issued 15 December 1990 Resolved
INSTALL COVER TO FUSE BOX ON THE PORT SIDE ENGINE MIDDLE LEVEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Fire Fighting
Issued 15 December 1990 Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS PROFESSIONALLY SERVICED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Electrical
Issued 15 December 1990 Resolved
INSTALL SAFETY GUARDS ON ROTATING MACHINERY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1990
Resolved 15 December 1990
Accommodation/Occupational Safety
Issued 4 December 1990 Resolved
33CFR151.67 IMPROPER DISPOSAL OF PLASTICS AT SEA._x001C_ _x001C_ _x001C_ AUTH: 33USC1903 PENALTY: 33USC1908_x001C_
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Documentation
Issued 4 December 1990 Resolved
33CFR151.25(H) NO SIGNATURE OF PERSON IN CHARGE AFTER EACH ENTRY IN VESSEL'S OIL RECORD BOOK._x001C_ _x001C_ AUTH: 33USC1321 PENALTY: 33USC1321_x001C_
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Documentation
Issued 4 December 1990 Resolved
33CFR155.450(A) NO "DISCHARGE OF OIL PROHIBITED" PLACARD POSTED IN THE ENGINE ROOM._x001C_ _x001C_ AUTH: 33USC1321 PENALTY: 33USC1321_x001C_
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Accommodation/Occupational Safety
Issued 4 December 1990 Resolved
33CFR159.7(C)(1) NO MARINE SANITATION DEVICE._x001C_ _x001C_ _x001C_ AUTH: 33USC1322 PENALTY: 33USC1322(J)_x001C_
Condition: Unknown
Due 17 December 1990
Resolved 4 December 1990
Engineering
Issued 4 December 1990 Resolved
33CFR155.430(A) NO STANDARD DISCHARGE CONNECTION FOR OILY WASTES._x001C_ _x001C_ _x001C_ AUTH: 33USC1321 PENALTY: 33USC1321_x001C_
Condition: Unknown
Due 17 December 1990
Resolved 4 December 1990
Documentation
Issued 4 December 1990 Resolved
33CFR155.750(A)(6),(A)(9) INCOMPLETE OIL TRANSFER PROCEDURES._x001C_ _x001C_ _x001C_ AUTH: 33 USC1321 PENALTY: 33USC1321_x001C_
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Engineering
Issued 4 December 1990 Resolved
33CFR155.350(A)(2) NO OPERABLE OILY WATER SEPARATOR._x001C_ _x001C_ _x001C_ AUTH: 33USC1321 PENALTY: 33USC1321_x001C_
Condition: Unknown
Due 17 December 1990
Resolved 4 December 1990
Documentation
Issued 9 August 1988 Resolved
VSL'S TRANSFER PROCEDURES CONTAINED ONLY NO. OF PERSONS REQUIRED, DUTIES BYTITLE OF OFFICERS, ETC, PROCEDURES FOR TENDING MOORING AND COMMS PROCEDURESVSL'S OIL CAPACITY IS 45,150 GALS
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.