Records from 2009 to 2026. Most recent: inspection, 24 February 2026.
Inspection history · 29
24 February 2026
Vessel Attendance · Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8309441
20 January 2026
Annual Survey · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8299022
1 March 2025
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 8086877
24 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8084044
7 December 2024
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 8044719
4 March 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7874080
23 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7869374
12 February 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864510
2 February 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7859793
13 December 2023
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7838415
7 August 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7762425
27 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7642782
15 February 2022
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7394166
7 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7392208
22 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7181203
12 March 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6924247
11 February 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6907258
16 September 2019
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6812992
16 September 2019
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6900489
14 March 2019
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6645034
19 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570668
8 March 2018
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364970
6 February 2018
Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6346238
19 March 2017
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6107575
9 March 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6101652
17 January 2017
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6071990
19 April 2016
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 5870412
14 April 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5847257
2 February 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5807794
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 February 2024
Resolved
Properly connect weak link to life float.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 4 March 2024
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 February 2024
Resolved
Relocate EPIRB to float free location.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 4 March 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 February 2024
Resolved
Provide Type I PFD donning placard for each style of Type I PFD carried onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 4 March 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2023
Resolved
Inspect steering componenets in accordance with 46 CFR 176.814. Stbd rudder gland was leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2023
Resolution: Owner provided proof of securing the leak at the rudder packing gland.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 February 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 February 2023
Resolution: Owner provided proof of an installed interconneccted fire detection system.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 15 February 2022
Resolved
Potable water tanks in engine room have significant deterioration in supporting frame. Renew in kind at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2024
Resolved 8 February 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 February 2022
Resolved
Smoke detector in forward accomodation space needs battery replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2022
Resolved 28 February 2023
Resolution: Owner provide proof of operational smoke detector.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 15 February 2022
Resolved
Forward escape hatch not operational from outside space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2022
Resolved 28 February 2023
Resolution: Owner provided proof of operational escape hatch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Remove excess fuel lines from starboard fuel tank
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2022
Resolved 28 February 2023
Resolution: Owner removed excess fuel lines.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 February 2022
Resolved
Properly label center fuel tank remove shutoff valve
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 28 February 2023
Resolution: Owner provided proof labeled shut off valve.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 15 February 2022
Resolved
Secure port engine exhaust hanger
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 28 February 2023
Resolution: Owner provided proof of exhaust hanger.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 February 2020
Resolved
Replace canvas damper covers with wood or metal.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 12 March 2020
Resolution: Verified metal dampners were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 March 2019
Resolved
Port clutch cable not properly secured to reduction gear. Vessel operator needs to properly secure cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 21 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 March 2019
Resolved
Broken battery post on generator start battery. Vessel operator needs to to reapir broken post.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 21 March 2019
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 14 March 2019
Resolved
Smoke detector is not mounted in accomodation space. Vessel operator need to mount detector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 21 March 2019
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 14 March 2019
Resolved
Globe covers are missing from lighting fixtures in cabin and engine room. Vessel operator needs to affix globes to fixtures.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2019
Resolved 21 March 2019
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 March 2018
Resolved
Provide valid FCC safety telephony certificate
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2018
Resolved 20 March 2018
Construction/Loadline › Penetrations › Gasket
Issued 8 March 2018
Resolved
Replace aft scuttle gasket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2018
Resolved 20 March 2018
Resolution: Vessel replaced gasket
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 6 February 2018
Resolved
Conduct operational test of the vessel underway once shafts and rudders are installed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2018
Resolved 8 March 2018
Resolution: operational tests completed, all SAT.
Engineering › Fuel Oil Service System › Hose
Issued 13 February 2017
Resolved
Fuel line fittings need to meet J1475
Condition: Improper Installation
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel installed proper fuel lines
Construction/Loadline › Structures › Scuttle
Issued 13 February 2017
Resolved
Aft hatch must have a device to prevent its loss.
Condition: Improper/Lack of Maintenance
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel installed hatch captive device
Engineering › Bilge Water Management System › Interface Detector
Issued 13 February 2017
Resolved
Label bilge system alarm panel on bridge.
Condition: Improper/Lack of Maintenance
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel labeled alarm panel
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 February 2017
Resolved
Seal hole on forward bulkhead in engine room.
Condition: Improper Installation
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel sealed hole
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 February 2017
Resolved
Vessel has two FCC call signs, need to to have one FCC call sign, and be reflected the same on all paperwork IAW 47 CFR 80
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel has corrected call sign issue
Navigation › Piloting/Steering › Marine Charts
Issued 13 February 2017
Resolved
Charts must be current and up-to-date.
Condition: Improper/Lack of Maintenance
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel provided up to date charts
Lifesaving › Lifefloat › Lifeline
Issued 17 January 2017
Resolved
Water light line for life float needs to be 18 feet or greater.
Condition: Improper Installation
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel properly replaced line