← All vessels
HAWK I
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southwest District (CGD-SW) · Other hulls named HAWK I
HAWK I is a 2001 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2002, most recently in May 2025, along with 95 deficiencies and 4 operational controls.
Records from 2002 to 2025. Most recent: inspection, 13 May 2025.
- Built
- 2001
- Last inspected
- 13 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 95 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1115614
WDA8574
31507
Flag
UNITED STATES
369147000 (licence lapsed)
Maury page id
psix-31507
Inspections, by type
The 31 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)35.7 ft × 14.0 ft × 6.8 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
18 - Simplified, Net Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDA8574MMSI 369147000 · expired · compulsorily equipped · granted 21 March 2012, cancelled 6 August 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 31
13 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8140172
27 April 2025
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8123551
9 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909435
16 May 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684922
3 May 2022
COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436140
28 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173973
6 October 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070203
26 August 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044342
11 May 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949131
30 April 2020
Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6946507
25 June 2019
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6728024
11 June 2018
Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441465
6 June 2017
COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138056
31 May 2017
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6161811
26 April 2016
DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863110
28 July 2015
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5198958
12 June 2014
Examination of Repairs · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4877823
30 May 2012
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4327633
3 January 2012
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4217788
28 April 2009
In-Service Inspection · Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3462754
14 May 2008
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3206226
5 May 2008
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3179259
10 July 2007
COI Inspection · Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2982966
24 October 2006
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2633260
2 March 2006
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2594528
22 August 2005
Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2470690
7 September 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2188887
8 September 2003
Deficiency Check · Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1899617
27 August 2002
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1671299
22 May 2002
Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1622843
14 March 2002
Simplified Stability Test
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1493860
Deficiency record · 95
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 May 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspection of life saving equipment... including the following inspection of each.. marine buoyant device. Vessel's life float found with signs of wear, effect repairs to MI satisfaction.
46 CFR 176.808(a)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and seperated from adult life jackets. Child life jackets found stowed in same container as adult jackets.
46 CFR 180.78(a)(5)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non combustible materials with no openings in the sides or bottom. Plastic trash cans found on main passenger deck.
46 CFR 177.405(f)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2025
Resolved
Cable and wire for power and lighting circuits must:
Meet Section 310-13 of NFPA 70.. Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable.. Non marine grade wire found on stbd deck speaker. Replace to MI satisfaction.
46 CFR 183.340(d)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 May 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings. Broken Railing discovered on stbd bow, repair to MI satisfaction.
46 CFR 176.802(a)(4)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 April 2025
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Vessel was found with a railing on the starboard side that was disconnecting from the weather deck and need to be reconnected.
46 CFR 177.900(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 April 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Vessel was found with 02 weather deck covers that were cracked and need to be replaced.
46 CFR 176.802(a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for reach watertight compartment. Forward bilge space not serviced by bilge pump.
46 CFR 182.25-5(a) 'Old T'
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 May 2024
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Engine room aft bulkhead found with non-vapor tight cable penetrations.
46 CFR 177.10-5
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 May 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Engine Room ventilation closures were ineffective.
46 CFR 182.465(h)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at leas 1 inch high indicating purpose of the valve and direction of operation. Fuel shutoff valves were not labeled.
46 CFR 185.608
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 April 2021
Resolved
"Condition that could adversly affect the safety of any vessel or structure. Condition could include leaking." 46 CFR 175.400
Leaking shaft seal in aft hatch
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2021
Resolved
"Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request." 46 CFR 185.520
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 October 2020
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Rudder mounting bracket allowed side to side and back and forth movement of the rudder post which caused the gasket to wear prematurely allowing water intrusion at certain speeds. Owner made satisfactory temporary repairs to limit water intrusion. Permanent repairs will have to be made prior to the 2021 operating season.
46CFR182.610(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either 160.002, 160.005, or 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Two of vessel's adult life jackets are not of the approved type. Vessel is reduced to carriage of 18 total persons on board.
46 CFR 180.71 (c)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 June 2019
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline such as the lazarette. Bilge alarm in lazarette was not operable upon request.
46 CFR 182.530 (a)(1)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Current drill and training logs were not available upon request.
46 CFR 185.420 (c)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019
Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Lifesaving equipment maintenance records were not available for inspection.
46 CFR 185.702 (d)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Vessel did not have location with number of life jackets labeled at the time of inspection.
46 CFR 185.604 (f)
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 June 2018
Resolved
Provisions Shall be made by means of plugs, covers, etc to prevent admission of air into the space protected. Adequate means to secure air to engine room is not provided. 46 CFR 181.10-35
Construction/Loadline › Penetrations › Gasket
Issued 13 June 2018
Resolved
The arrangement of a vessel must allow for the safe operation of the vessel. The rudder seal is taking on excessive amounts of water. 46 CFR 177.100
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2018
Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in each compartment. Lazarrette high water alarm is inoperable. 46 CFR 182.530
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 June 2018
Resolved
An adult life jacket must be provided for each person carried onboard a vessel. Vessel is missing 4 adult life jackets as required on COI. Vessel is limited to 16 adult persons onboard until life jackets are replaced. 46 CFR 180.71
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 June 2018
Resolved
The number and identification of the items stowed inside and their sizes must be clearly legible letters nad numbers on each container for life jackets. Placards onboard do not reflect the reqired amount of life jackets onboard (20 Adult and 2 Child). 46 CFR 185.604 (f)
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 June 2017
Resolved
Vessel is missing US Coast Pilot. 46 CFR 184.420
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 June 2017
Resolved
Vessel is missing Coast Guard Light List. 46 CFR 184.420
Navigation › Piloting/Steering › Marine Charts
Issued 18 June 2017
Resolved
Vessel had no charts of the local operating area. 46 CFR 184.420
Lifesaving › Hand Flares › Quantity
Issued 18 June 2017
Resolved
Vessel is missing 1 hand held flare. 46 CFR 180.68
Stability › Weathertight Integrity › General
Issued 18 June 2017
Resolved
Aft hatch contained two broken latches and gasket is not sealing. 46 CFR 171.24
Engineering › Bilge Water Management System › Pump
Issued 18 June 2017
Resolved
Both Submersible bilge pumps are not UL rated. 46 CFR 182.520
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 June 2017
Resolved
Space behind steering console has direct communication with Engine Room preventing it from being vapor tight. 46 CFR 177.405
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 June 2017
Resolved
Vessel is missing 05 adult size life jackets. 46 CFR 180.71
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 18 June 2017
Resolved
Child Life Jackets were not labeled. 46 CFR 185.604
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 18 June 2017
Resolved
Vessel did not have chains at embarkation points. Rails were not at 36 inches. 46 CFR 177.35-1
Fire Fighting › Fire Bucket › Quantity
Issued 18 June 2017
Resolved
Vessel did not have any of the required firebuckets onboard. 46 CFR 181.610
Engineering › Bilge Water Management System › Pump
Issued 18 June 2017
Resolved
Secondary Bilge Pump is not present IAW 46 CFR 182.520.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 3 May 2016
Resolved
Flexible fuel return line at fuel injector copper tubing connection fitting found loose and stressed by inproper mounting of flexible hose.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 28 July 2015
Resolved
Prove that the installed fixed fire system automatically shuts down the main engine when actuated.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 July 2015
Resolved
Remove all spilled diesel from the lazarette bilge.
Engineering › Bilge Water Management System › Pump
Issued 28 July 2015
Resolved
Provide proof that the installed submersible bilge pumps are UL1113 rated.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 July 2015
Resolved
Provide 5 additional adult life jackets. (Vessel limited to 15 total persons.)
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 July 2015
Resolved
Provide replacement burn gauze and iodine applicators for the first aid kit.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2015
Resolved
Ensure all wiring in the engine room has metallic wire supports at 2 foot increments.
Engineering › Fuel Oil Service System › Filter
Issued 30 May 2012
Resolved
Mount metal bowl onto fuel strainer 46 CFR 182.455(b)(6).
Engineering › Lubricating Oil Service System › Filter
Issued 30 May 2012
Resolved
Properly mount oil strainer in engine compartment IAW 46 CFR 182.220.
Engineering › Steering Gear System › Rudder Stock
Issued 30 May 2012
Resolved
Repair seal on rudder stock IAW 46 CFR 182.610.
Lifesaving › Lifefloat › Serviceable
Issued 30 May 2012
Resolved
Repair life float IAW manufacturer specs IAW 46 CFR 180.175 prior to carrying passengers. May operate within 3 NM from shore.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 May 2012
Resolved
Replace clip on lifejacket / retroreflective tape IAW 46 CFR 180.71. Limited to 12 passengers until corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2012
Resolved
First aid kit, replace ammonia inhalants / burn gel IAW 46 CFR 184.710.
Documentation › Logs/Records › Drug Test Records
Issued 5 May 2008
Resolved
Provide evidence of drug and alcohol program
Communications › Audible Communications › Horn/Whistle
Issued 5 May 2008
Resolved
Repair horn and mount switch
Communications › Radio Communications › EPIRB
Issued 5 May 2008
Resolved
Replace EPIRB hydro release (prior to going more than 3 miles from shore
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2008
Resolved
Install missing deck rail aft port side
Lifesaving › Lifefloat › Serviceable
Issued 5 May 2008
Resolved
Replace life float and mark with vessel name (prior to going over 3 miles
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 May 2008
Resolved
Mount holder for life float water light (prior to going more 3 miles from shore)
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 May 2008
Resolved
Install whistle on (4) life jackets (prior to going more than 3 miles from shore)
Documentation › Markings/Placards › Lifejacket Placard
Issued 5 May 2008
Resolved
Post life jacket donning placards
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2008
Resolved
Replace items first aid kit
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 May 2008
Resolved
Demonstrate proper operation of fixed extinguishing system
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 May 2008
Resolved
Mark bilge high level alarms
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 July 2007
Resolved
Install retro reflective tape on (2) lifejackets.
Engineering › Bilge Water Management System › Not Installed
Issued 10 July 2007
Resolved
Re-install bilge high level alarm with visible/audible alarm at operating station
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 July 2007
Resolved
Remove wing nuts on batteries, install hex nuts
Personnel › Certificates/Documents/Licenses › License, Master
Issued 10 July 2007
Resolved
Provide CG license for Master.
Documentation › Logs/Records › Drug Test Records
Issued 24 October 2006
Resolved
Provide serious marine incident test kit.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 October 2006
Resolved
Provide original certificated of documentation.
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 October 2006
Resolved
Repair compass light.
Lifesaving › Hand Flares › Storage
Issued 24 October 2006
Resolved
Mark distress signal box.
Communications › Radio Communications › EPIRB
Issued 24 October 2006
Resolved
EPIRB. Service EPIRB hydro date expired.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 October 2006
Resolved
Install keeper for engine room compartment.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 October 2006
Resolved
Replace six adults and two children life jackets.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 October 2006
Resolved
Mark storage bins for adult and child PFD's Ensure child PFD stored in a separate location
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 October 2006
Resolved
Replace expired items in first-aid kit.
Engineering › Fuel Oil Service System › Filter
Issued 24 October 2006
Resolved
Install flame bowl on fuel filters.
Engineering › Bilge Water Management System › Not Operational
Issued 24 October 2006
Resolved
Install visible and audible bilge high level alarms at operating station.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 October 2006
Resolved
Conduct underway drills.
Lifesaving › Lifebuoys › Serviceable
Issued 29 September 2005
Resolved
Provide non-corrosive clip with appropriate lifeline for ring buoy
Communications › Audible Communications › Horn/Whistle
Issued 29 September 2005
Resolved
Make ships horn audible/operational. Provide alternative means of sound signal while being repaired.
Lifesaving › Lifefloat › Markings
Issued 29 September 2005
Resolved
Stencil vessel name on life float.
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2005
Resolved
Repair chips in gelcoat through to glass in bow.
Engineering › Bilge Water Management System › Strainer
Issued 22 August 2005
Resolved
Clean out external sea strainer STBD outboard.
Deck/Cargo › Ballast › Valves
Issued 22 August 2005
Resolved
Reseal STBD aft overboard fitting.
Documentation › Logs/Records › Logbook (official)
Issued 7 September 2004
Resolved
Record testing of EPIRB monthly as well as lifesaving maintenance.
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 September 2004
Resolved
Replace worn retro tape on lifefloat.
Lifesaving › Lifebuoys › Serviceable
Issued 7 September 2004
Resolved
Replace lifering (line deteriorated). Attach waterlight with 3' of polypropelyne line and clip.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2004
Resolved
Replace expired eye wash and ammonia inhalants.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 7 September 2004
Resolved
Provide list of employees covered under current contract.
Stability › Freeing Ports
Issued 8 September 2003
Resolved
Open up area of freeing port "cap" to equal size of original area
Communications › Radio Communications
Issued 8 September 2003
Resolved
Re-locate EPIRB so it may float free LEGACY COMPONENT DESC: EPIRB
Communications › Alarms/Indicators
Issued 8 September 2003
Resolved
Test high water alarm (audible & visual) located in engine space to attending inspector. LEGACY COMPONENT DESC: Bilge Alarm
Documentation › Logs/Records
Issued 8 September 2003
Resolved
Provide and keep up to date livesaving maintenance log.
Operations/Management › Drills/Instruction
Issued 8 September 2003
Resolved
Contact MSD Ft. Myers to conduct underway portion of annual inspection as well as conduct drills.
Engineering › Fuel Oil Service System
Issued 8 September 2003
Resolved
Provide ventilation for fuel tank space IAW 46 CFR 182.470 LEGACY COMPONENT DESC: Vent Pipe
Stability › Watertight Integrity
Issued 8 September 2003
Resolved
Provide watertight closure for engine hatch cover IAW 46 CFR 179.360
Accommodation/Occupational Safety › Occupational Safety
Issued 8 September 2003
Resolved
Provide rail height of 36" LEGACY COMPONENT DESC: Deck Rail
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.