HAWK I

HAWK I is a 2001 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in May 2025, along with 37 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 13 May 2025.

Built
2001
Last inspected
13 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDA8574
Flag
UNITED STATES
Maury page id
psix-31507

Inspections, by type

Years with a record 10 calendar years (2016–2025)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)35.7 ft × 14.0 ft × 6.8 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 15

13 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8140172
27 April 2025 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8123551
9 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909435
16 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684922
3 May 2022 COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436140
28 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173973
6 October 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070203
26 August 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044342
11 May 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949131
30 April 2020 Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6946507
25 June 2019 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6728024
11 June 2018 Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441465
6 June 2017 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138056
31 May 2017 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6161811
26 April 2016 DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863110

Deficiency record · 37

11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 May 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspection of life saving equipment... including the following inspection of each.. marine buoyant device. Vessel's life float found with signs of wear, effect repairs to MI satisfaction. 46 CFR 176.808(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 19 May 2025
Resolution: completed effective repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2025 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and seperated from adult life jackets. Child life jackets found stowed in same container as adult jackets. 46 CFR 180.78(a)(5)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 20 May 2025
Resolution: Placed child life jackets in seperate container.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non combustible materials with no openings in the sides or bottom. Plastic trash cans found on main passenger deck. 46 CFR 177.405(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 30 June 2025
Resolution: Operator emailed receipt for fleet order of fire resistant waste receptacles. Receipt uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2025 Resolved
Cable and wire for power and lighting circuits must: Meet Section 310-13 of NFPA 70.. Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable.. Non marine grade wire found on stbd deck speaker. Replace to MI satisfaction. 46 CFR 183.340(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 19 May 2025
Resolution: Replaced wires with marine grade wires.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 May 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings. Broken Railing discovered on stbd bow, repair to MI satisfaction. 46 CFR 176.802(a)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 19 May 2025
Resolution: Repaired railing to MI satisfaction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 April 2025 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Vessel was found with a railing on the starboard side that was disconnecting from the weather deck and need to be reconnected. 46 CFR 177.900(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2025
Resolved 13 May 2025
Resolution: MI conducting annual inspection 13MAY2025 verified correction to starboard side railing.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 April 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Vessel was found with 02 weather deck covers that were cracked and need to be replaced. 46 CFR 176.802(a)(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2025
Resolved 13 May 2025
Resolution: MI conducting annual inspection 13MAY2025 verified replacement of cracked hatch covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for reach watertight compartment. Forward bilge space not serviced by bilge pump. 46 CFR 182.25-5(a) 'Old T'
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 1 June 2024
Resolution: Forward bilge space made watertight to restore its purpose as a 'small buoyancy chamber.'
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 May 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Engine room aft bulkhead found with non-vapor tight cable penetrations. 46 CFR 177.10-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 2 July 2024
Resolution: Aft bulkhead cable penetrations made vapor tight.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 May 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Engine Room ventilation closures were ineffective. 46 CFR 182.465(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 2 July 2024
Resolution: Means for securing engine room ventilation provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at leas 1 inch high indicating purpose of the valve and direction of operation. Fuel shutoff valves were not labeled. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 2 July 2024
Resolution: Fuel shut off valves labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 April 2021 Resolved
"Condition that could adversly affect the safety of any vessel or structure. Condition could include leaking." 46 CFR 175.400 Leaking shaft seal in aft hatch
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 17 June 2021
Resolution: Provided photos of fixed leaking shaft seal. Photo is provided in the documents section.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2021 Resolved
"Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request." 46 CFR 185.520
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 11 May 2021
Resolution: Provided evidence of vessel log book onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 October 2020 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Rudder mounting bracket allowed side to side and back and forth movement of the rudder post which caused the gasket to wear prematurely allowing water intrusion at certain speeds. Owner made satisfactory temporary repairs to limit water intrusion. Permanent repairs will have to be made prior to the 2021 operating season. 46CFR182.610(a)(1)
Action required: 705 - Other - as specified
Due 1 May 2021
Resolved 3 May 2022
Resolution: No water intrusion found in vicinity of rudder post while in transit
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019 Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either 160.002, 160.005, or 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Two of vessel's adult life jackets are not of the approved type. Vessel is reduced to carriage of 18 total persons on board. 46 CFR 180.71 (c)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2019
Resolved 2 July 2019
Resolution: Vessel representative sent MI picture of two new approved lifejackets labeled with vessel name.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 June 2019 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline such as the lazarette. Bilge alarm in lazarette was not operable upon request. 46 CFR 182.530 (a)(1)
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Fixed bilge alarm and tested it in front of Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Current drill and training logs were not available upon request. 46 CFR 185.420 (c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Provided Marine Inspector with a copy of current drill and training logs.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Lifesaving equipment maintenance records were not available for inspection. 46 CFR 185.702 (d)
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Provided Marine Inspector with current lifesaving equipment maintenance records.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Vessel did not have location with number of life jackets labeled at the time of inspection. 46 CFR 185.604 (f)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Labeled location for life jackets with number of life jackets and type (adult/children).
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 June 2018 Resolved
Provisions Shall be made by means of plugs, covers, etc to prevent admission of air into the space protected. Adequate means to secure air to engine room is not provided. 46 CFR 181.10-35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 10 July 2018
Resolution: Plugs were provided and attached near vents for closure of Engineroom ventilation.
Construction/Loadline › Penetrations › Gasket
Issued 13 June 2018 Resolved
The arrangement of a vessel must allow for the safe operation of the vessel. The rudder seal is taking on excessive amounts of water. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2018
Resolved 14 June 2018
Resolution: Rudder Seal Replaced with new dripless seal. No water is currently entering vessel through seal.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2018 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in each compartment. Lazarrette high water alarm is inoperable. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2018
Resolved 14 June 2018
Resolution: New high water bilge alarm installed and tested satisfactory.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 June 2018 Resolved
An adult life jacket must be provided for each person carried onboard a vessel. Vessel is missing 4 adult life jackets as required on COI. Vessel is limited to 16 adult persons onboard until life jackets are replaced. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 10 July 2018
Resolution: Four Adult Life Jackets were added to the vessel.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 June 2018 Resolved
The number and identification of the items stowed inside and their sizes must be clearly legible letters nad numbers on each container for life jackets. Placards onboard do not reflect the reqired amount of life jackets onboard (20 Adult and 2 Child). 46 CFR 185.604 (f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 21 August 2018
Resolution: Labeling was changed to reflect the required amount of life jackets.
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 June 2017 Resolved
Vessel is missing US Coast Pilot. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 14 July 2017
Resolution: US Coast Pilot was provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 June 2017 Resolved
Vessel is missing Coast Guard Light List. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Due 19 July 2017
Resolved 14 July 2017
Resolution: Coast Guard Light List was provided.
Navigation › Piloting/Steering › Marine Charts
Issued 18 June 2017 Resolved
Vessel had no charts of the local operating area. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Charts of local operating area provided.
Lifesaving › Hand Flares › Quantity
Issued 18 June 2017 Resolved
Vessel is missing 1 hand held flare. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: 01 Handheld distress signal provided.
Stability › Weathertight Integrity › General
Issued 18 June 2017 Resolved
Aft hatch contained two broken latches and gasket is not sealing. 46 CFR 171.24
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 19 July 2017
Resolution: Installed new latches.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2017 Resolved
Both Submersible bilge pumps are not UL rated. 46 CFR 182.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Bilge Pumps were replaced with UL rated ones.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 June 2017 Resolved
Space behind steering console has direct communication with Engine Room preventing it from being vapor tight. 46 CFR 177.405
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Space behind console is sealed vapor tight.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 June 2017 Resolved
Vessel is missing 05 adult size life jackets. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 June 2017
Resolution: 05 Adult Life Jackets with proper labeling were provided.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 18 June 2017 Resolved
Child Life Jackets were not labeled. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 June 2017
Resolution: Life Jackets were labeled.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 18 June 2017 Resolved
Vessel did not have chains at embarkation points. Rails were not at 36 inches. 46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Chains were installed at imbarkation points.
Fire Fighting › Fire Bucket › Quantity
Issued 18 June 2017 Resolved
Vessel did not have any of the required firebuckets onboard. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 June 2017
Resolution: 3 firebuckets were provided. 2 1/2 gallon with handle and proper labeling.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2017 Resolved
Secondary Bilge Pump is not present IAW 46 CFR 182.520.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 June 2017
Resolution: Portable Hand Pump provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 3 May 2016 Resolved
Flexible fuel return line at fuel injector copper tubing connection fitting found loose and stressed by inproper mounting of flexible hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Remounted flexible fuel return line and tightened copper tubing connection fitting. Operational tested with no signs of leaking or stress.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.