HAWK I is a 2001 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2002, most recently in May 2025, along with 95 deficiencies and 4 operational controls.

Records from 2002 to 2025. Most recent: inspection, 13 May 2025.

Built
2001
Last inspected
13 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA8574
Flag
UNITED STATES
369147000 (licence lapsed)
Maury page id
psix-31507

Inspections, by type

Years with a record 21 calendar years (2002–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)35.7 ft × 14.0 ft × 6.8 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA8574MMSI 369147000 · expired · compulsorily equipped · granted 21 March 2012, cancelled 6 August 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 31

13 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8140172
27 April 2025 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8123551
9 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909435
16 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684922
3 May 2022 COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436140
28 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173973
6 October 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070203
26 August 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044342
11 May 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949131
30 April 2020 Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6946507
25 June 2019 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6728024
11 June 2018 Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441465
6 June 2017 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138056
31 May 2017 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6161811
26 April 2016 DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863110
28 July 2015 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5198958
12 June 2014 Examination of Repairs · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4877823
30 May 2012 DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4327633
3 January 2012 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4217788
28 April 2009 In-Service Inspection · Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3462754
14 May 2008 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3206226
5 May 2008 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3179259
10 July 2007 COI Inspection · Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2982966
24 October 2006 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2633260
2 March 2006 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2594528
22 August 2005 Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2470690
7 September 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2188887
8 September 2003 Deficiency Check · Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1899617
27 August 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1671299
22 May 2002 Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1622843
14 March 2002 Simplified Stability Test
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1493860

Deficiency record · 95

11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 May 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspection of life saving equipment... including the following inspection of each.. marine buoyant device. Vessel's life float found with signs of wear, effect repairs to MI satisfaction. 46 CFR 176.808(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 19 May 2025
Resolution: completed effective repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2025 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and seperated from adult life jackets. Child life jackets found stowed in same container as adult jackets. 46 CFR 180.78(a)(5)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 20 May 2025
Resolution: Placed child life jackets in seperate container.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non combustible materials with no openings in the sides or bottom. Plastic trash cans found on main passenger deck. 46 CFR 177.405(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 30 June 2025
Resolution: Operator emailed receipt for fleet order of fire resistant waste receptacles. Receipt uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2025 Resolved
Cable and wire for power and lighting circuits must: Meet Section 310-13 of NFPA 70.. Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable.. Non marine grade wire found on stbd deck speaker. Replace to MI satisfaction. 46 CFR 183.340(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 19 May 2025
Resolution: Replaced wires with marine grade wires.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 May 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings. Broken Railing discovered on stbd bow, repair to MI satisfaction. 46 CFR 176.802(a)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 19 May 2025
Resolution: Repaired railing to MI satisfaction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 April 2025 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Vessel was found with a railing on the starboard side that was disconnecting from the weather deck and need to be reconnected. 46 CFR 177.900(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2025
Resolved 13 May 2025
Resolution: MI conducting annual inspection 13MAY2025 verified correction to starboard side railing.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 April 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Vessel was found with 02 weather deck covers that were cracked and need to be replaced. 46 CFR 176.802(a)(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2025
Resolved 13 May 2025
Resolution: MI conducting annual inspection 13MAY2025 verified replacement of cracked hatch covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for reach watertight compartment. Forward bilge space not serviced by bilge pump. 46 CFR 182.25-5(a) 'Old T'
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 1 June 2024
Resolution: Forward bilge space made watertight to restore its purpose as a 'small buoyancy chamber.'
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 May 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Engine room aft bulkhead found with non-vapor tight cable penetrations. 46 CFR 177.10-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 2 July 2024
Resolution: Aft bulkhead cable penetrations made vapor tight.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 May 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Engine Room ventilation closures were ineffective. 46 CFR 182.465(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 2 July 2024
Resolution: Means for securing engine room ventilation provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at leas 1 inch high indicating purpose of the valve and direction of operation. Fuel shutoff valves were not labeled. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 2 July 2024
Resolution: Fuel shut off valves labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 April 2021 Resolved
"Condition that could adversly affect the safety of any vessel or structure. Condition could include leaking." 46 CFR 175.400 Leaking shaft seal in aft hatch
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 17 June 2021
Resolution: Provided photos of fixed leaking shaft seal. Photo is provided in the documents section.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2021 Resolved
"Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request." 46 CFR 185.520
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 11 May 2021
Resolution: Provided evidence of vessel log book onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 October 2020 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Rudder mounting bracket allowed side to side and back and forth movement of the rudder post which caused the gasket to wear prematurely allowing water intrusion at certain speeds. Owner made satisfactory temporary repairs to limit water intrusion. Permanent repairs will have to be made prior to the 2021 operating season. 46CFR182.610(a)(1)
Action required: 705 - Other - as specified
Due 1 May 2021
Resolved 3 May 2022
Resolution: No water intrusion found in vicinity of rudder post while in transit
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019 Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either 160.002, 160.005, or 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Two of vessel's adult life jackets are not of the approved type. Vessel is reduced to carriage of 18 total persons on board. 46 CFR 180.71 (c)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2019
Resolved 2 July 2019
Resolution: Vessel representative sent MI picture of two new approved lifejackets labeled with vessel name.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 June 2019 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline such as the lazarette. Bilge alarm in lazarette was not operable upon request. 46 CFR 182.530 (a)(1)
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Fixed bilge alarm and tested it in front of Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Current drill and training logs were not available upon request. 46 CFR 185.420 (c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Provided Marine Inspector with a copy of current drill and training logs.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Lifesaving equipment maintenance records were not available for inspection. 46 CFR 185.702 (d)
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Provided Marine Inspector with current lifesaving equipment maintenance records.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Vessel did not have location with number of life jackets labeled at the time of inspection. 46 CFR 185.604 (f)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Labeled location for life jackets with number of life jackets and type (adult/children).
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 June 2018 Resolved
Provisions Shall be made by means of plugs, covers, etc to prevent admission of air into the space protected. Adequate means to secure air to engine room is not provided. 46 CFR 181.10-35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 10 July 2018
Resolution: Plugs were provided and attached near vents for closure of Engineroom ventilation.
Construction/Loadline › Penetrations › Gasket
Issued 13 June 2018 Resolved
The arrangement of a vessel must allow for the safe operation of the vessel. The rudder seal is taking on excessive amounts of water. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2018
Resolved 14 June 2018
Resolution: Rudder Seal Replaced with new dripless seal. No water is currently entering vessel through seal.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2018 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in each compartment. Lazarrette high water alarm is inoperable. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2018
Resolved 14 June 2018
Resolution: New high water bilge alarm installed and tested satisfactory.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 June 2018 Resolved
An adult life jacket must be provided for each person carried onboard a vessel. Vessel is missing 4 adult life jackets as required on COI. Vessel is limited to 16 adult persons onboard until life jackets are replaced. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 10 July 2018
Resolution: Four Adult Life Jackets were added to the vessel.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 June 2018 Resolved
The number and identification of the items stowed inside and their sizes must be clearly legible letters nad numbers on each container for life jackets. Placards onboard do not reflect the reqired amount of life jackets onboard (20 Adult and 2 Child). 46 CFR 185.604 (f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2018
Resolved 21 August 2018
Resolution: Labeling was changed to reflect the required amount of life jackets.
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 June 2017 Resolved
Vessel is missing US Coast Pilot. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 14 July 2017
Resolution: US Coast Pilot was provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 June 2017 Resolved
Vessel is missing Coast Guard Light List. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Due 19 July 2017
Resolved 14 July 2017
Resolution: Coast Guard Light List was provided.
Navigation › Piloting/Steering › Marine Charts
Issued 18 June 2017 Resolved
Vessel had no charts of the local operating area. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Charts of local operating area provided.
Lifesaving › Hand Flares › Quantity
Issued 18 June 2017 Resolved
Vessel is missing 1 hand held flare. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: 01 Handheld distress signal provided.
Stability › Weathertight Integrity › General
Issued 18 June 2017 Resolved
Aft hatch contained two broken latches and gasket is not sealing. 46 CFR 171.24
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 19 July 2017
Resolution: Installed new latches.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2017 Resolved
Both Submersible bilge pumps are not UL rated. 46 CFR 182.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Bilge Pumps were replaced with UL rated ones.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 June 2017 Resolved
Space behind steering console has direct communication with Engine Room preventing it from being vapor tight. 46 CFR 177.405
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Space behind console is sealed vapor tight.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 June 2017 Resolved
Vessel is missing 05 adult size life jackets. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 June 2017
Resolution: 05 Adult Life Jackets with proper labeling were provided.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 18 June 2017 Resolved
Child Life Jackets were not labeled. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 June 2017
Resolution: Life Jackets were labeled.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 18 June 2017 Resolved
Vessel did not have chains at embarkation points. Rails were not at 36 inches. 46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 14 July 2017
Resolution: Chains were installed at imbarkation points.
Fire Fighting › Fire Bucket › Quantity
Issued 18 June 2017 Resolved
Vessel did not have any of the required firebuckets onboard. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 June 2017
Resolution: 3 firebuckets were provided. 2 1/2 gallon with handle and proper labeling.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2017 Resolved
Secondary Bilge Pump is not present IAW 46 CFR 182.520.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 June 2017
Resolution: Portable Hand Pump provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 3 May 2016 Resolved
Flexible fuel return line at fuel injector copper tubing connection fitting found loose and stressed by inproper mounting of flexible hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Remounted flexible fuel return line and tightened copper tubing connection fitting. Operational tested with no signs of leaking or stress.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 28 July 2015 Resolved
Prove that the installed fixed fire system automatically shuts down the main engine when actuated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2015
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 July 2015 Resolved
Remove all spilled diesel from the lazarette bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2015
Engineering › Bilge Water Management System › Pump
Issued 28 July 2015 Resolved
Provide proof that the installed submersible bilge pumps are UL1113 rated.
Due 29 August 2015
Resolved 28 August 2015
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 July 2015 Resolved
Provide 5 additional adult life jackets. (Vessel limited to 15 total persons.)
Action required: 705 - Other - as specified
Due 29 August 2015
Resolved 28 August 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 July 2015 Resolved
Provide replacement burn gauze and iodine applicators for the first aid kit.
Due 29 August 2015
Resolved 28 August 2015
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2015 Resolved
Ensure all wiring in the engine room has metallic wire supports at 2 foot increments.
Due 29 August 2015
Resolved 28 August 2015
Engineering › Fuel Oil Service System › Filter
Issued 30 May 2012 Resolved
Mount metal bowl onto fuel strainer 46 CFR 182.455(b)(6).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Engineering › Lubricating Oil Service System › Filter
Issued 30 May 2012 Resolved
Properly mount oil strainer in engine compartment IAW 46 CFR 182.220.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Engineering › Steering Gear System › Rudder Stock
Issued 30 May 2012 Resolved
Repair seal on rudder stock IAW 46 CFR 182.610.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Lifesaving › Lifefloat › Serviceable
Issued 30 May 2012 Resolved
Repair life float IAW manufacturer specs IAW 46 CFR 180.175 prior to carrying passengers. May operate within 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 June 2012
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 May 2012 Resolved
Replace clip on lifejacket / retroreflective tape IAW 46 CFR 180.71. Limited to 12 passengers until corrected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2012 Resolved
First aid kit, replace ammonia inhalants / burn gel IAW 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 7 June 2012
Documentation › Logs/Records › Drug Test Records
Issued 5 May 2008 Resolved
Provide evidence of drug and alcohol program
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Communications › Audible Communications › Horn/Whistle
Issued 5 May 2008 Resolved
Repair horn and mount switch
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2008
Communications › Radio Communications › EPIRB
Issued 5 May 2008 Resolved
Replace EPIRB hydro release (prior to going more than 3 miles from shore
Due 16 May 2008
Resolved 6 May 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2008 Resolved
Install missing deck rail aft port side
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Lifesaving › Lifefloat › Serviceable
Issued 5 May 2008 Resolved
Replace life float and mark with vessel name (prior to going over 3 miles
Due 16 May 2008
Resolved 29 May 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 May 2008 Resolved
Mount holder for life float water light (prior to going more 3 miles from shore)
Due 16 May 2008
Resolved 5 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 May 2008 Resolved
Install whistle on (4) life jackets (prior to going more than 3 miles from shore)
Due 16 May 2008
Resolved 5 May 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 5 May 2008 Resolved
Post life jacket donning placards
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2008 Resolved
Replace items first aid kit
Due 16 May 2008
Resolved 5 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 May 2008 Resolved
Demonstrate proper operation of fixed extinguishing system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 May 2008 Resolved
Mark bilge high level alarms
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 July 2007 Resolved
Install retro reflective tape on (2) lifejackets.
Due 17 July 2007
Resolved 19 July 2007
Engineering › Bilge Water Management System › Not Installed
Issued 10 July 2007 Resolved
Re-install bilge high level alarm with visible/audible alarm at operating station
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 July 2007 Resolved
Remove wing nuts on batteries, install hex nuts
Due 17 July 2007
Resolved 19 July 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 10 July 2007 Resolved
Provide CG license for Master.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Documentation › Logs/Records › Drug Test Records
Issued 24 October 2006 Resolved
Provide serious marine incident test kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2006
Resolved 1 November 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 October 2006 Resolved
Provide original certificated of documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 October 2006 Resolved
Repair compass light.
Due 2 November 2006
Resolved 1 November 2006
Lifesaving › Hand Flares › Storage
Issued 24 October 2006 Resolved
Mark distress signal box.
Due 2 November 2006
Resolved 1 November 2006
Communications › Radio Communications › EPIRB
Issued 24 October 2006 Resolved
EPIRB. Service EPIRB hydro date expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2006
Resolved 1 November 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 October 2006 Resolved
Install keeper for engine room compartment.
Due 2 November 2006
Resolved 1 November 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 October 2006 Resolved
Replace six adults and two children life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2006
Resolved 1 November 2006
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 October 2006 Resolved
Mark storage bins for adult and child PFD's Ensure child PFD stored in a separate location
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 October 2006 Resolved
Replace expired items in first-aid kit.
Due 2 November 2006
Resolved 1 November 2006
Engineering › Fuel Oil Service System › Filter
Issued 24 October 2006 Resolved
Install flame bowl on fuel filters.
Due 2 November 2006
Resolved 1 November 2006
Engineering › Bilge Water Management System › Not Operational
Issued 24 October 2006 Resolved
Install visible and audible bilge high level alarms at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 October 2006 Resolved
Conduct underway drills.
Action required: 705 - Other - as specified
Resolved 1 November 2006
Lifesaving › Lifebuoys › Serviceable
Issued 29 September 2005 Resolved
Provide non-corrosive clip with appropriate lifeline for ring buoy
Due 15 October 2005
Resolved 16 November 2005
Resolution: replaced
Communications › Audible Communications › Horn/Whistle
Issued 29 September 2005 Resolved
Make ships horn audible/operational. Provide alternative means of sound signal while being repaired.
Due 15 October 2005
Resolved 16 November 2005
Resolution: cleared
Lifesaving › Lifefloat › Markings
Issued 29 September 2005 Resolved
Stencil vessel name on life float.
Due 29 September 2005
Resolved 29 September 2005
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2005 Resolved
Repair chips in gelcoat through to glass in bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2005
Resolution: Cleared
Engineering › Bilge Water Management System › Strainer
Issued 22 August 2005 Resolved
Clean out external sea strainer STBD outboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2005
Resolution: Cleared
Deck/Cargo › Ballast › Valves
Issued 22 August 2005 Resolved
Reseal STBD aft overboard fitting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2005
Resolution: Cleared
Documentation › Logs/Records › Logbook (official)
Issued 7 September 2004 Resolved
Record testing of EPIRB monthly as well as lifesaving maintenance.
Action required: 705 - Other - as specified
Due 7 September 2004
Resolved 7 September 2004
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 September 2004 Resolved
Replace worn retro tape on lifefloat.
Action required: 705 - Other - as specified
Due 15 September 2004
Resolved 7 September 2004
Lifesaving › Lifebuoys › Serviceable
Issued 7 September 2004 Resolved
Replace lifering (line deteriorated). Attach waterlight with 3' of polypropelyne line and clip.
Action required: 705 - Other - as specified
Due 15 September 2004
Resolved 7 September 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2004 Resolved
Replace expired eye wash and ammonia inhalants.
Action required: 705 - Other - as specified
Due 15 September 2004
Resolved 7 September 2004
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 7 September 2004 Resolved
Provide list of employees covered under current contract.
Action required: 705 - Other - as specified
Due 15 September 2004
Resolved 7 September 2004
Stability › Freeing Ports
Issued 8 September 2003 Resolved
Open up area of freeing port "cap" to equal size of original area
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 18 September 2003
Resolution: owner drilled holes in "bubble" flapper.
Communications › Radio Communications
Issued 8 September 2003 Resolved
Re-locate EPIRB so it may float free LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2003
Resolved 18 September 2003
Communications › Alarms/Indicators
Issued 8 September 2003 Resolved
Test high water alarm (audible & visual) located in engine space to attending inspector. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 18 September 2003
Documentation › Logs/Records
Issued 8 September 2003 Resolved
Provide and keep up to date livesaving maintenance log.
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 18 September 2003
Operations/Management › Drills/Instruction
Issued 8 September 2003 Resolved
Contact MSD Ft. Myers to conduct underway portion of annual inspection as well as conduct drills.
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 18 September 2003
Resolution: Drills not conducted due to time constraints.
Engineering › Fuel Oil Service System
Issued 8 September 2003 Resolved
Provide ventilation for fuel tank space IAW 46 CFR 182.470 LEGACY COMPONENT DESC: Vent Pipe
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 7 October 2003
Resolution: Installed 1.5" goose neck pipe into fuel tank space
Stability › Watertight Integrity
Issued 8 September 2003 Resolved
Provide watertight closure for engine hatch cover IAW 46 CFR 179.360
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 18 September 2003
Resolution: Owner provided gasket and recessed latches on engine space entry hatch.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 September 2003 Resolved
Provide rail height of 36" LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 7 October 2003
Resolution: Provided rail of 36". Gaps between rails made no more han 12" by installing chain.