Inspection record

Last inspected 13 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2706
315936
Flag
UNITED STATES
Maury page id
psix-315936

Documentation record

Registered dimensions (L × B × D)77.7 ft × 28.6 ft × 8.4 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBUILDING · SOMERSET, MA, UNITED STATES · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 29 inspections, each with its date, unit and type; 69 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

13 February 2026 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8310510
18 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8160153
19 August 2024 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7984732
8 August 2024 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7976898
18 April 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7897345
17 January 2024 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7850477
26 December 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7842566
19 October 2023 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7811555
7 July 2023 Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7736220
13 April 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7668243
27 March 2023 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7650594
27 March 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7660252
31 January 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7629602
15 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7476123
18 January 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7380554
19 June 2021 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7229326
15 April 2021 Plan Review (Other than "T")
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7176644
5 March 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7150775
14 January 2021 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7207632
8 January 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7153765
29 January 2019 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6616843
27 June 2018 Internal Structural Exam · Drydock Exam · Examination of Repairs · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6458360
17 January 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6338933
22 September 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6272312
3 February 2017 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6081558
4 January 2017 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6066160
2 December 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6064816
7 November 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036541
23 March 2016 Uninspected Other
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5849133

Deficiency record · 69

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Starboard side's transmission, overboard discharge pipe for raw cooling water was found severely deteriorated. Instead of renewing the pipe, a piece of flexible hose with two clams at each end was installed. Crop and renew damaged section of pipe and test for the satisfaction of an attending USCG Marine Inspector. 46 CFR 115.830 Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2025
Resolution: A section was welded in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Starboard side's main diesel engine , overboard discharge pipe for raw cooling water was found corroded with penetration. Instead of renewing the pipe, a piece of flexible hose with two clams at each end was installed. Crop and renew damaged section of pipe and test for the satisfaction of an attending USCG Marine Inspector. 46 CFR 115.830 Code 17C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 3 July 2025
Resolution: A new segment of pipe was prepared and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2025 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (3) A means to reset devices used to automatically shut down ventilation systems and engines. Starboard side main diesel engine emergency override actuator device failed to operate upon actuation, and engine couldn't be re-started from the local control at the operating station. 46 CFR 118.420 Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2025
Resolution: Tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 18 June 2025 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Starboard side engine room (CO2 protected space) forward watertight bulkhead piping, penetrating the bulkhead towards the forward void (diesel fuel tanks)was found to have a gap. Properly seal with an approved fire retardant filler material and make water & airtight. 46 CFR 116.415 & 46 CFR 171.114 Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2025
Resolution: Penetration was corrected with filler material that is fireproof.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2025 Resolved
Exhaust gas must not leak from the piping or any connections. Exhaust leak was found in stbd side pipe riser, above the engine room access hatch. 46 CFR 119.430 Code 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 3 July 2025
Resolution: A new exhaust flexible below was installed, with a gasket. Previous one was found fractured.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 June 2025 Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors. (b) If twist-on type of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. (c) Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Several cables were found not connected (dead-end),and other with twist-on connectors in the following locations: 1. underneath the operating station. 2. portside engine room adjacent to the engine controls in the aft watertight bulkhead. 46 CFR 111.60-17 Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 3 July 2025
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The selector knob for generator 1 and 2, in the electrical cabinet located at the main deck was missing, and a metallic conducting wrench is being used as a substitute of a non-conducting electrical selector knob. 46 CFR 115.830 code 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 8 July 2025
Resolution: A new non conductive knob was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2024 Resolved
46 CFR 182.100 This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vsl conducted repairs to steering system. Schedule sea trial with SSJ Prevention. Conduct underway test of steering system repairs to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2024
Resolved 19 August 2024
Resolution: Conducted a sea trial for over 45 minuts while conducting "S" and "8" manouvers at different speeds and found steering system in good operating condition.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 April 2024 Resolved
46 CFR 119.430(b) Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. High levels of CO2 and H2S was discovered in the port engine room causing inspectors 4 gas meters to alarm. Properly correct exhaust leaks the satisfaction of the marine inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2024
Resolved 26 April 2024
Resolution: New flexible bellow was installed in the riser outside of the engine room and adjacent to the blower, fire protection lagging was installed as well.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 April 2024 Resolved
46 CFR 115.830(b) At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Stbd side engine room, outboard bulkhead has oil leaking behind the engine room insulation from an unknown source. Find source of oil leak and repair to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2024
Resolved 22 April 2024
Resolution: Two sets of screws at the base of the turbo were replaced for proper seal preventing oil leak.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 April 2024 Resolved
46 CFR 117.205 Each vessel operating in warm water may be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. 46 CFR 117.205 Vessel is required in accordance with the Certificate of Inspection to have 03 Survival crafts (inflatable Buoyant Apparatus (IBA) on board, however, currently only have 02 installed with a total capacity for 100 Persons. Vessel is restricted to carrying a total of 200 persons on board including crew and passengers, until the additional required IBA is installed for service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2024
Resolved 28 August 2024
Resolution: A new IBA was received and installed on board for servfice, IBA serial number is 13163255 Manufactured 04/2024. Passenger carriage restriction has been released.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 April 2024 Resolved
46 CFR 115.814 At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Pump #2 low level hydraulic fluid audio alarm was found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: Both audio and visual low level steering fluid was replaced and workinbg for pump number 2.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 April 2024 Resolved
46 CFR 174.220 Each hatch exposed to the weather must be watertight. The lazzarette starboard side access hatch was found with worn gasket seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2024
Resolution: Tested the hatch for water intrusion as it was fixed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2024 Resolved
46 CFR 115.830 (b) At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Oily rags have been found in both port and starboard engine rooms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2024
Resolved 23 April 2024
Resolution: Debris and rags have been removed from the engine rooms port and starboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2024 Resolved
46 CFR 115.830 At each inspection for certification and at every other 46 vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Portside engine room fuel filter flame arrester metallic bowl was found with diesel fuel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: All fluids have been removed from the flame arrester bowl.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 April 2024 Resolved
46 CFR 11.840 The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Clean corrosion of portside fuel tank top for detailed inspection by USCG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: Fuel tank was cleaned, cooper piping removed, tank aluminium top was found still in good condition.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 April 2024 Resolved
46 CFR 115.816 The owner or managing operator shall be prepared to test and make available for inspection all items in the ship's outfit, such as ground tackle, navigation lights and equipment, markings, and placards, which are required to be carried by the regulations in this subchapter, as necessary to determine that they are fit for the service intended. The switchboards located at the operating station Nav pannel I, Nav Panel II, and 12V DC, were found several closed circuit "red LED" indication light inoperable and two incorrectly connected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: Tested all switches and indication LED lights were tested and found fully operational.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 18 April 2024 Resolved
46 CFR 122.420 The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including the duties listed in the station bill required by § 122.514. Provide crewmember training in their assigned duties as stated in the posted station bill, provide evidence of training to the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 26 April 2024
Resolution: Evidence of training was presented upon request.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 April 2024 Resolved
46 CFR 121.420 As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. (b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Publication have been found last updated in YR2022. Deficiency was corrected prior finishing the exam.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2024
Resolved 18 April 2024
Resolution: Charts were updated on the spot as it was electronical.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operation at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of power on the starboard engine. Engine unable to maintain operation under load. 46 CFR 119.200(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2023
Resolved 19 July 2023
Resolution: Vessel identified issue as the fuel pump. Replaced part in kind. Witnessed pump operation and conducted sea trial. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2023 Resolved
07199: At each subsequent inspection for certification a vessel shall be prepared to conduct operational tests of all valves and fuel lines by operating locally and at remote operating positions. Fuel shut off valves for both diesel engines and generators were unable to be tested.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 April 2023
Resolution: Voids were opened to allow MI to verify Fuel shut-off valve operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 April 2023 Resolved
CG001: The Certificate of Inspection (COI) must be posted. The vessel did not have the most current COI posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 27 April 2023
Resolution: The vessel was issued a new and current COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 April 2023 Resolved
01119: Each vessel must ensure the following document is carried on board and made available to the Coast Guard upon request: a letter signed by the vessel owner stating which alternative security program (ASP) the vessel is using and certifying that the vessel is in full compliance with that program. The vessel is not listed on the current ASP.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 27 April 2023
Resolution: SUMMER WIND was seen listed on the ASP.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 13 April 2023 Resolved
01209: No vessel may be navigated unless it has in its service and on board the crew complement required by the COI. The Senior Deckhand was not designated in writing as indicated on the COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 27 April 2023
Resolution: The list of Senior deckhands has been updated by the company.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 April 2023 Resolved
09112: A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first-aid kit did not contain the required contents.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 27 April 2023
Resolution: Vessel purchased a new USCG approved first-aid kit
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 13 April 2023 Resolved
04101: On a vessel of more than 65 ft in length, the public address (PA) system must be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members [name withheld] speaker on the port side outer deck was not operational.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 27 April 2023
Resolution: PA speaker was found fully operational.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 March 2023 Resolved
Proposed alterations must be approved by the OCMI before work is started. 1. Found that port ship generator exhaust lagging was installed incorrectly which left a gap in two areas that exposed the underside of the two boxes to melt, the dripping plastic contacted the hot exhaust piping causing a fire. 2. The lagging prevents the pressure cap on the diesel generator cooling expansion tank from being removed. 3. Both batteries are required to be relocated. 17C 46 CFR 115.700(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2023
Resolution: Plans for relocation of batteries have been submitted by vessel owner/operator and approved locally. Batteries have been relocated, lagging was reinstalled. pressure cap is accessible.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2023 Resolved
Proposed alterations must be approved by OCMI before work is started. Found that battery acid had spilled on the port generator and migrated to the bilge. The battery acid to be removed from the generator and the hull plating so the hull plating can be evaluated for damage. 17C 46CFR115.840.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2023
Resolution: Battery acid was removed, bilges was cleaned, verified the condition of the hull plating and found no evidence of damage at the moment of the deficiency check. Recommend to continue to verify the condition of the hull plating at each examination.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 March 2023 Resolved
Proposed alterations must be approved by OCMI prior work is started. 1. Found that the two steering pumps/tanks had been replaced, provide specifications on the old and new units, i.e. weight of units, electrical specifications. 2. Found non-metallic hose had been replaced with stainless steel piping, provide specifications showing the piping meets the requirements in 46 CFR Subpart G. 3. Found that the stainless steel piping that replaced the non-metallic piping for the steering system was not properly supported; piping flexed 2-3 inches when moved by hand. 17C 46CFR115.700
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2023
Resolution: Plans submitted to SSJ OCMI and approved localy and pumps and electrical were found in compliance. Proper support was provided to the stainless steel piping.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2023 Resolved
Found that all voids aft of the port & starboard engine rooms exhibited excessive aluminum salt forming on overhead, longitudinals, and hull plating, all areas to be cleaned for evaluation. Remove nuts and bolts and miscellaneous items on the longitudinal bilges. 46CFR115.840 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2023
Resolution: Both compartments were found cleaned, with no deposit of aluminum salts; deck, hull plating and longitudinals have been found with minimal pitting. A special note will be added to observe any changes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2023 Resolved
A dry chemical chemical extinguisher had to be used to put out a fire in way of the diesel generator, open port generator for inspections. 46CFR115.840 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2023
Resolution: Witnessed the operation of port diesel generator under load. Mechanic stated that the generator was cleaned prior to return to service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 March 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel was taken out of service to prepare for COI annual. Vessel operator rescheduled inspection date on multiple occasions. On 27MAR23, a further postponing of the annual inspection was requested. At that time it was reported to the USCG that work was being done to the vessel's steering assembly. Additionally, it was reported that damage was sustained to a battery bank resulting in melting and lagging onboard the vessel within a machinery space. The SUMMER WIND shall be made available for inspection the morning of the 28th of MARCH for the purpose of conducting a damage survey/in service inspection. 46 CFR 115.840
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2023
Resolution: Verified the new installation of the battery bank, in accordance with the approved plans, verified the proper installation of exhaust piping lagging. Verified the proper installation and tested during sea trials the steering pumps. All found satisfactor
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 June 2022 Resolved
A self-priming power driven fire pump must be provided on each vessel. The fire pump must provide a steady stream of at least 50 psi. The starboard hull’s fire pump was not easily primed and the gauge showed a pressure of 30 psi while testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 5 August 2022
Resolution: Vessel fire pump was repaired and adequate pressure was shown at the gauge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts or wires. There were several loose wires located at the port engine compartment in-way-of the generator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 14 July 2022
Resolution: Loose wires were properly secured.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 June 2022 Resolved
The bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard. On the port hull engine compartment there was an excessive amount of oily water noticed on the bilges.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 June 2022
Resolved 16 June 2022
Resolution: Bilges cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2022 Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The starboard main engine had noticeable oil and fuel leaks throughout the engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 15 September 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 June 2022 Resolved
Each EPIRB must be tested monthly to determine that it is operative. The EPIRB test required shall be logged or otherwise documented. The last 02 logged EPIRB monthly tests were in June 2022 and Sep 2021.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 5 August 2022
Resolution: Monthly EPIRB tests properly logged for July and August to satisfaction of the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 June 2022 Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: A self-propelled vessel of 65 ft or more in length engaged in commercial service and a propelled vessel that is certificated to carry more that 150 passengers. The installed AIS is not fully operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 14 July 2022
Resolution: Vessel AIS was updated and accurate information is now being transmitted.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. The required public address system was not operational.
Action required: 10 - Deficiency Rectified
Resolved 16 June 2022
Resolution: PA system is operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2022 Resolved
At each initial and subsequent inspection for certification, the owner or operator shall have the vessel ready for inspection of its fire protection equipment to check for excessive corrosion and general condition. The portable fire extinguisher in the starboard engine room was found with a broken nozzle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 14 July 2022
Resolution: Vessel replaced fire extinguisher nozzle.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2022 Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corrected. There was a fuel leak identified on the fill pipe on the port hull, void space no. 2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 16 June 2022
Resolution: Fuel leak has been corrected.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 June 2022 Resolved
A fire control plan must show the location of fire protection and emergency equipment. The current posted fire control plan does not correctly identify the number of heat detectors installed on board. In addition, the heat detector on the port side, above the engine room ventilation is missing.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 15 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2022 Resolved
An adult life jacket must be provided for each person carried on board the vessel. In addition, child life jackets equal to at least 10% of the passenger carrying capacity of the vessel must be provided on the vessel. There were two (02) adult life jackets and four (04) child sized life jackets need to be replaced as they were in an unserviceable condition.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 15 June 2022
Resolution: Life jackets were replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 June 2022 Resolved
All observed unsafe practices or other hazardous situations must be corrected. There are several fractured welds on void spaces 1P, 2P & 2S. Submit repair proposal prior to starting repair process.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 15 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2022 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. Shaft should be pull out and inspected to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 10 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 June 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Vessel port side battery bank was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2021
Resolution: Vessel replaced port side battery bank with new batteries, operational test satisfactory. Vessel rep and company mechanic attest to proper operations and batteries installed/receipts/statements were reviewed by Duty MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 22 April 2021 Resolved
Each vessel msut have permanent draft marks at each end of the vessel. The aft port draft marks are missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2022
Resolved 24 January 2022
Resolution: Markings were placed and observed by attending MI's during DDE.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2021 Resolved
Structural fire protection, general arrangement/outfitting. Properly insulate fire boundary between main deck and operating station, class A boundary
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 22 April 2021
Resolution: New insulation inatalled.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2021 Resolved
Structural fire protection, general arrangement/outfitting. Properly insulate fire boundary in the Port MDE space and adjoining ladder well bottom, class A boundary
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 22 April 2021
Resolution: New insulaiton installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2021 Resolved
Structural fire protection, general arrangement/outfitting. Properly insulate fire boundary in the STBD MDE space and adjoining ladder well bottom, class A boundary
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 22 April 2021
Resolution: New insulation installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2021 Resolved
Structural fire protection, general arrangement/outfitting. Properly insulate fire boundary under the ladder well leading from the pilot house deck to the 01 deck, class A boundary
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 22 April 2021
Resolution: New insulaiton installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2021 Resolved
In the presence of a Marine Inspector complete the testing of the Propulsion Control Qualitative Failure Analysis (QFA) and Design Verification and Periodic Test(DVTP) procedures per MSC Plan review letter E2-2100376 dated February 17, 2021. Provide all references listed in the letter prior to conducting the testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2021
Resolved 28 July 2021
Resolution: Documentary evidence received proving completion in Sector New York prior to the vessels arrival.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 February 2019 Resolved
Each survival craft shall be secured to the vessel by a painter with a float free link permanently attached to the vessel. The painter line for each IBA is set up incorrectly. The painter line for each IBA was secured straight to the vessel. The painter line must be attached to the weak link.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
Resolution: Secured IBAs properly
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 1 February 2019 Resolved
The vessel owner must ensure restricted areas are designated on board the vessel. The navigation bridge is identified as a restricted area and is not properly marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
Resolution: Properly marked nav bridge with restricted access signage
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 February 2019 Resolved
The ASP is sensitive security information and must be protected in accordance with 49 CFR 1520. Sensitive security information must be stored in a secured container. ASP does not have a designated secured container.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
Resolution: provided ASP lock box
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 February 2019 Resolved
Vessel is required to carry at a minimum 40-B;C type portable fire extinguishers in each machinery space. Vessel did not have the correct type of fire extinguisher in the machinery spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
Resolution: provided proper portable fire extingushing equipment for engine rooms.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 1 February 2019 Resolved
Supervisory personnel must receive 60 minutes of training in regard to the Employee Assistance Program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2019
Resolved 22 February 2019
Resolution: provided proof of training.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 February 2019 Resolved
Vessel's ground detection meter is inoperable. Once ground detection meter is operational, vessel must prove proper operation by introducing a ground.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
Resolution: proved proper operation of ground detection equipment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 February 2019 Resolved
Due to repair/installation of new engine propulsion equipment, vessel must provide a statement of all propulsion equipment removed, rebuilt, and replaced, and in addition, a bill of materials including spec sheets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2019
Resolution: Vessel provided statement.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 June 2018 Resolved
Port and Stbd E/R: Fire dampers inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
Resolution: Port and Stbd fire dampners operable
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2018 Resolved
Stbd E/R: Improper patch w/ hose clamp on bilge pump discharge pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 February 2019
Resolution: Discharge bilge pipe repaired properly
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 June 2018 Resolved
Port E/R: Replace broken pressure gauge on fire pump disharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 February 2019
Resolution: Pressure gauge installed
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 27 June 2018 Resolved
Port E/R: Replace deteriorated fuel lines on generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
Resolution: Fuel lines replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2018 Resolved
Isolate ground on main switchboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 February 2019
Resolution: Ground isloated.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 June 2018 Resolved
2nd Deck, Aft Weather Deck: Provide missing cover on electrical junction box @ outboard stbd overhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 February 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 June 2018 Resolved
Conduct drills in the presence of a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 22 September 2017 Resolved
One of the vessel's 50-person inflatable buoyant apparatus has been removed for annual servicing. Total persons allowed on board when operating on a Limited Coastwise route beyond three nautical miles from shore is limited to 200 prior to 1 October and 150 from 1 October on until the IBA has been re-installed to the satisfaction of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 November 2017
Resolved 21 November 2017
Resolution: The IBA was properly installed and back onboard the vessel.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 February 2017 Resolved
Prove proper operation of heat detectors in port and STBD engin rooms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 24 March 2017
Resolution: Vessel rep. provided tech report.
Engineering › Fuel Oil Service System › Valve
Issued 3 February 2017 Resolved
Install manual fuel shutoff valves for port and stbd fuel lines at or near the fwd fuel tanks.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 24 March 2017
Resolution: Verified proper operation of fuel shut off valves on both port and stbd hulls.