Records from 1992 to 2002. Most recent: inspection, 8 April 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
8 April 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1602434
15 February 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 287031
30 November 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 385392
3 April 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 689541
28 January 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 374800
23 June 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 689542
9 June 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 358923
21 April 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 357759
23 November 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 689543
27 October 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 354193
Lifesaving
Issued 15 February 2001
Resolved
Install lights on each life preserver IAW 46 CFR 25.25-13.
Condition: Unknown
Due 15 February 2001
Resolved 26 March 2001
Lifesaving
Issued 15 February 2001
Resolved
Install retro-reflective tape on all life preservers IAW 46 CFR 25.25-15.
Condition: Unknown
Due 16 February 2001
Resolved 8 April 2002
Accommodation/Occupational Safety
Issued 15 February 2001
Resolved
Properly placard MSD IAW 33 CFR 159.59 prior to next U.S. port.
Condition: Unknown
Due 16 February 2001
Resolved 8 April 2002
Accommodation/Occupational Safety
Issued 15 February 2001
Resolved
Provide certification of the MSD by USCG or MARPOL IAW 33 CFR 159.7 prior to next U.S port.
Condition: Unknown
Due 16 February 2001
Resolved 8 April 2002
Documentation
Issued 15 February 2001
Resolved
Prove that the garbage log is maintained in Japanese IAW MARPOL V, Regulation 9(3).
Condition: Unknown
Due 16 February 2001
Resolved 8 April 2002
Documentation
Issued 15 February 2001
Resolved
Prove that the garbage log has been maintained onboard for two years IAW MARPOL V, Regulation 9(3).
Condition: Unknown
Due 16 February 2001
Resolved 8 April 2002
Engineering
Issued 15 February 2001
Resolved
Modify the standard discharge connection to meet the requirements of 33 CFR155.430 prior to next U.S port.
Condition: Unknown
Due 16 February 2001
Resolved 8 April 2002
Lifesaving
Issued 21 April 1993
Resolved
BOARDED VESSEL FOR DISCREPANCY FOLLOWUP. FOUND PFD'S TO NOT HAVE THE REQUIRED AMOUNT OF RETRO REFLECTIVE MATERIAL ATTACHED.
Condition: Unknown
Due 20 June 1993
Resolved 20 June 1993
Lifesaving
Issued 21 April 1993
Resolved
BOARDED VESSEL FOR DISCREPANCY FOLLOWUP. FOUND PFD'S TO BE STOWED IN THE EXTREME FORWARD SECTION OF THE VESSEL. PFD'S WERE VERY HARD TO LOCATE AND RETRIEVE.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Accommodation/Occupational Safety
Issued 27 October 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 June 1993
Resolved 20 June 1993
Lifesaving
Issued 27 October 1992
Resolved
Conducted an annual examination of the F/V Kyoshin maru no.8,found that theowner failed to provide the proper emergency lighting on the vessels P.F.D.s.
Condition: Unknown
Due 20 June 1993
Resolved 20 June 1993