← All vessels
KIRSTEN
KIRSTEN is a 1988 tank ship. The Coast Guard has recorded 37 inspections since 1990, most recently in December 2008, along with 40 deficiencies and 4 operational controls.
Records from 1990 to 2008. Most recent: inspection, 28 December 2008.
- Built
- 1988
- Last inspected
- 28 December 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 40 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8614467 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LAPM5
316220
Flag
DENMARK
—
Maury page id
psix-316220
Inspections, by type
…with no type recorded18
Years with a record
14 calendar years (1990–2008)
The 37 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it44322 - Simplified, Gross Ton
44322 - Convention (Subpart B), Gross Ton
20402 - Convention (Subpart B), Net Ton
83651 - Dead Weight, Ton
20402 - Simplified, Net Ton
91273 - Displacement, Ton
44322 - Convention (Subpart B), Gross Ton
20402 - Convention (Subpart B), Net Ton
83651 - Dead Weight, Ton
20402 - Simplified, Net Ton
91273 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 37
28 December 2008
MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · Loadline Exam · COC-CHEM Renew · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3383287
6 May 2008
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3199782
24 September 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3064677
20 September 2007
ISPS II Exam · COC-TVE Renew · Deficiency Check · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3062033
18 July 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2999650
6 July 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2985424
5 July 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2984209
4 June 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2951561
7 April 2007
MARPOL Annex II Examination · MARPOL Annex I Examination · COC-CHEM Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2903453
4 April 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2901479
13 September 2005
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2491257
29 July 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2156019
10 June 2004
MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2094429
17 February 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2007479
16 January 2003
MARPOL Annex I Examination · MARPOL Annex V Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1731213
28 February 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 287678
27 February 2001
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1362001
14 January 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 158064
11 January 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 285799
24 June 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 279034
24 June 2000
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1051309
20 April 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415031
15 October 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 409009
15 October 1997
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392785
9 September 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 191835
9 September 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 767619
19 July 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 393657
19 July 1996
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1028649
19 December 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 502424
9 June 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 379051
8 June 1995
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1191338
19 April 1994
Type not recorded
No type recorded · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 366213
19 April 1994
Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396080
9 February 1993
Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 828378
26 October 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 339934
13 October 1990
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 339800
13 October 1990
Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 918563
Deficiency record · 40
Lifesaving › Lifeboat › Hull
Issued 20 September 2007
Resolved
STBD lifeboat: Soft patch on the port side forward 3 feet from the stem and 1 foot above the keel. Spot has a radius of 2''. Issue must be addressed by class prior to 24SEP2007 and or departure of Port Canaveral.
Engineering › Electric Propulsion System › Circuit Breaker (overload/over current protection)
Issued 18 July 2007
Resolved
Electronic speed setting on bridge for speed increase did not function on bridge, engine maintained full control. Engine room is manned 24hours. Request report faxed to Sector Miami upon repair. Malfunction was not logged in log books, it was logged electronically. Condition of class given; engine room must be manned 24/7 until repairs are made
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 7 April 2007
Resolved
Vessel is to discharge cargo from cargo tank #1 port, #5 stbd, and #6 stbd and inert tanks IAW approved discharge plan at Gravesend Bay Anchorage to isolate cargo contamination of #6 starboard water ballast tank. After discharging remainder of vessel cargo at berth, submit Class Society report of damage survey of affected area and a permanent repair proposal prior to departing COTP New York Zone.
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 7 April 2007
Resolved
Provide plan to dispose of any contaminated water introduced into #6 starboard water ballast tank or cargo tanks as a result of survey operations.
Deck/Cargo › Cargo Stowage › General
Issued 7 April 2007
Resolved
Provide report form your classification society Det Norske Veritas to US Coast Guard, describing damage found and repairs made to the crack in the #6 starboard ballast tank. Prior to entry into US Waters.
Deck/Cargo
Issued 28 February 2001
Resolved
GASOLINE VAPORS FOUND IN #5P BALLAST TANK. CLASS REPORT STATING FITNESS FORINTENDED ROUTE AND PURPOSE MUST BE SUBMITTED PRIOR TO NEXT CARGO AND PRIOR TO 27MAR2001.
Deck/Cargo
Issued 27 February 2001
Resolved
#5 port ballast tank found to have 65% LEL gasoline vapors while discharging cargo in port of NY. Class (DNV) issued outstanding requirementto gass free for an internal survey this ballast tanks and adjacent cargo tank for purpose of certifying fit for intended route and purpose.
Electrical
Issued 24 June 2000
Resolved
Label bus/breaker outside starboard crew laundry. SOLAS 74 amended II- 1/45.6.2.
Construction/Loadline
Issued 24 June 2000
Resolved
Vent for incinerator sludge tank wasted and needs to be renewed. ICLL 1966reg 20.
Fire Fighting
Issued 24 June 2000
Resolved
Fire box 27 missing wrench. SOLAS 74 amended II-2/7.1.
Navigation
Issued 24 June 2000
Resolved
Record/log all pre-arrival and pre-departure tests in the ship's log. 33CFR164.25.
Accommodation/Occupational Safety
Issued 24 June 2000
Resolved
Portside accomadation ladder has several broken steps. SOLAS 74 amended _x001C_ I/11
Construction/Loadline
Issued 24 June 2000
Resolved
Loadline markings must be permanently afixed and a painted a contrasting color tot he hull. ICLL 1966 reg 8.
Lifesaving
Issued 24 June 2000
Resolved
Fix frozen shieve on starboard lifeboat davit. SOLAS 74 amended III/19.2.
Deck/Cargo
Issued 24 June 2000
Resolved
Repair sensor for low seawater level in deck water seal sealing pipe. SOLAS 74 amended II-2/62.19.1.
Deck/Cargo
Issued 24 June 2000
Resolved
Replace all inoperative lamps on IGS panel board.
Construction/Loadline
Issued 24 June 2000
Resolved
Renew wasted ares of overhead in crew laundry, starboard side. SOLAS 74 amended II-2/58.3.
Construction/Loadline
Issued 24 June 2000
Resolved
Plug the opening that leads from the cargo control room down to the firefighting plant space with approved fire stopper. SOLAS 74 amended II- 1/25.9.
Documentation
Issued 24 June 2000
Resolved
Ensure SOLAS training manual includes crew familiarization, all firefighting equipment and document crew members training. SOLAS 74 amended III/18.
Lifesaving
Issued 15 October 1997
Resolved
Repair starboard lifeboat engine. Engine will only operate in forward gear.
Lifesaving
Issued 15 October 1997
Resolved
Repair leaking damaged areas on bottom of starboard lifeboat hull.
Deck/Cargo
Issued 15 October 1997
Resolved
Demonstrate proper operation of inert gas system prior to moving to berth or transferring cargo.
Deck/Cargo
Issued 15 October 1997
Resolved
Provide certificate of training for vapor control system prior to operatingsystem.
Deck/Cargo
Issued 15 October 1997
Resolved
Vapor control system missing locating pin at manifold flange. Provide locating pins prior to operating vapor control system.
Engineering
Issued 15 October 1997
Resolved
Demonstrate proper operation of 15ppm engine room bilge oil water separator. The overboard recirculation valve does not work. Oil water separator must be repair before vessel returns to U.S. waters.
Documentation
Issued 19 July 1996
Resolved
WHILE CONDUCTING AN EXAM OF THE VESSEL FOUND THAT THE OIL TRANSFER PROCEDURES WERE MISSING THE PROCEDURES FOR EMPTYING THE MANIFOLD CONTAINMENT AS REQUIRED UNDER 33CFR155.750(a)(2)(iii)._x001C_ _x001C_
Documentation
Issued 19 July 1996
Resolved
WHILE CONDUCTING AN EXAM OF THE VESSEL FOUND THAT THE OIL TRANSFER PROCEDURES WERE NOT IN THE ORDER LISTED OR HAVE A CROSS REFERENCE INDEX PAGE AS REQUIRED UNDER 33CFR155.750(a).
Documentation
Issued 19 July 1996
Resolved
WHILE CONDUCTING AN EXAM OF THE VESSEL FOUND THAT THE OIL TRANSFER PROCEDURES WERE MISSING THE LIST OF THE PRODUCTS TRANSFERED AS REQUIRED UNDER 33CFR155.750(A)(1).
Lifesaving
Issued 9 June 1995
Resolved
THE SHIP'S NAME WAS NOT STENCILED ON THE LIFE BOAT OARS OR THE LIFEJACKETS.
Accommodation/Occupational Safety
Issued 9 June 1995
Resolved
THERE WAS RAT POISON STORED IN THE MEDICAL SPACES.
Deck/Cargo
Issued 26 October 1990
Resolved
33CFR156.120(e) VESSEL FAILED TO CLOSE THE VALVES TO SLOP TANK AFTER TANK CLEANING WAS DONE. THESE VALVES WERE NOT NEEDED FOR THE TRANSFER OF CARGO.WHEN VESSEL STARTED TRANSFERRING CARGO, THE SLOP TANK WAS BEING LOADED AND IT WAS OVER PRESSURED CAUSING THE RELEASE OF CARGO FROM THE SLOP TANK.
Documentation
Issued 13 October 1990
Resolved
VSL WAS MISSING OIL TRANSFER PROCEDURES, WHICH ARE REQUIRED BY 33 CFR 155.720. THE CAPACITY FOR CARGO WAS IN EXCESS OF 250 BBLS.
Deck/Cargo
Issued 13 October 1990
Resolved
CARGO HOSES NOT MARKED IAW 33 CFR 154.500 (F)(1-4)._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 13 October 1990
Resolved
VSL MISSING SIMPLE INSTRUCTIONS AND BLOCK DIAGRAM SHOWING THE CHANGEOVER PROCEDURES FOR REMOTE STEERING ON THE BRIDGE AS REQUIRED BY 33 CFR 164.35(K). VESSEL IS 44322 GT.
Deck/Cargo
Issued 13 October 1990
Resolved
DEMONSTATE PROPER OPERATION OF PORTABLE OXYGEN AND EXPLOSIVE GAS METERS.
Fire Fighting
Issued 13 October 1990
Resolved
LABEL VALVES IN FIREFIGHTING FOAM SYSTEM AS PER INSTRUCTION PLACARD.
Documentation
Issued 13 October 1990
Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR CARGO OIL SYSTEM.
Deck/Cargo
Issued 13 October 1990
Resolved
MARK CARGO HOSES WITH TEST AND SERVICE DATA.
Engineering
Issued 13 October 1990
Resolved
PROVE OPERATION OF 15 PPM ALARM AND MONITOR FOR OILY WATER SEPERATOR.
Navigation
Issued 13 October 1990
Resolved
POST INSTUCTIONS FOR EMERGENCY STEERING AT BRIDGE STEERING STATION.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.