MAURY USCG vessel records Sign in
← All vessels

MONTROSE

MONTROSE is a 2001 freight ship. The Coast Guard has recorded 24 inspections since 2002, most recently in December 2018, along with 8 deficiencies and 4 operational controls.

Records from 2002 to 2018. Most recent: inspection, 27 December 2018.

Built
2001
Last inspected
27 December 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9223813 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
CYPRUS
—
Maury page id
psix-31638

Inspections, by type

…with no type recorded6
Years with a record 11 calendar years (2002–2018)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17944 - Convention (Subpart B), Gross Ton
9697 - Convention (Subpart B), Net Ton
34934 - Displacement, Ton
27028 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

27 December 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6603341
3 December 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6590927
17 July 2018 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6481085
1 January 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6331066
6 June 2014 Administrative Inspection · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4881032
4 February 2012 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4230962
2 November 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3883025
28 October 2010 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3876084
23 October 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3876094
4 March 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3679808
9 December 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3376799
20 November 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3101555
9 May 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2926011
8 May 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2925021
14 March 2007 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2888910
13 March 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2887295
3 June 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2669063
10 June 2005 ISPS II Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2386103
1 December 2004 PII Safety Exam · Spot Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2247101
30 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2250794
27 April 2004 MTSA/ISPS Verification · Annual Inspection
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2053657
12 June 2003 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1814733
14 April 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1773658
6 June 2002 Ballast Water Examination · Periodic Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1627379

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 December 2018 Resolved
The function of fixed fire detection and fire alarm system shall be periodically tested to the satisfaction of the administration by means of producing hot air at the appropriate temperature. Vessel did not have heat producing gun required by Administration, despite 02 requisition requests to company.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 27 December 2018
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 July 2018 Resolved
01 - Fire protection systems and fire fighting systems and appliances shall be maintained and ready for use. The PSCO found four remote fuel oil quick-closing valves blocked in the open position. The crew explained that two of the valves were blocked in preparation to test with superintendent on 07JUN2018 and forgot to remove. The other two valves have been blocked by previous crew and went unnoticed during monthly tests. The crew would not have been able to isolate fuel oil or diesel oil remotely in the event of a fire in the engine room. - 74/78 SOLAS (2014 CONS.) II-2/14.1.1 - 30ac
Action required: 30 - Ship detained
Resolved 20 July 2018
Resolution: Received class survey stating that the attending surveyor has verified that all blocking devices have been removed from quick closing valves in the engine room and all quick closing valves have been tested and confirmed fully operational.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 July 2018 Resolved
02 - Fire fighting systems shall be maintained ready for use. PSCO found the remote actuator for CO2 discharge valve to the engine room with the safety pin in place. The safety pin must be removed to actuate the valve remotely. the chief engineer explained he forgot to remove after giving familiarization training to the crew on 09JUL2018. - 74/78 SOLAS (2014 CONS) II-2/14.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2018
Resolution: Received class survey stating that the attending surveyor has verified that ship's CO2 firefighting system has been returned to normal operation and is fully operational and ready for use including remote operation.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 July 2018 Resolved
03 - The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea. PSCO observed the rudder hunting five degrees with both pumps operable. Captain stated they use both pumps when maneuvering. - 74/78 SOLAS (2014 CONS) I/11.a - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2018
Resolution: Received class survey stating that a shore technician was arranged and adjustments to the ship's steering system were carried out. The satisfactory operation of the steering system was carried out and verified by the attending surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 17 July 2018 Resolved
04 - The company should establish procedures for key shipboard operations. There are no procedures for testing the vessel's remote quick-closing valves. - 74/78 SOLAS (2014 CONS) XI-I/1 ISM CODE PART A/7 - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 July 2018
Resolution: Class survey states that the company has provided revision to the ship's SMS and provided instructions for testing of ship's remotely operated quick closing valves in the engine room. The SMS revision was verified this time by the attending surveyor.
Electrical › Lighting (emergency) › Outlet Box
Issued 1 January 2018 Resolved
j
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 January 2018
Resolution: Corrected on the spot.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 October 2010 Resolved
0611 - Lifeboat Inventory - It was observed that all 23 air tight food rations for the life boat are no longer air tight, replace all food rations as original. - LSA Code 4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 29 October 2010
Resolution: Recieved delivery receipt for lifeboat food rations.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 4 March 2010 Resolved
Ship's free-fall lifeboat battery was found in need of replacement during operational test of lifeboat engine. Ship to supply purchase order receipt to the satisfaction of the Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2010
Resolved 4 March 2010
Resolution: MSU Savannah received an invoice from vessel agent attesting to the purchase of marine batteries for the free-fall lifeboat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.