Behind this panel: 4 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 4
27 December 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6603341
3 December 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6590927
17 July 2018
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6481085
1 January 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6331066
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 December 2018
Resolved
The function of fixed fire detection and fire alarm system shall be periodically tested to the satisfaction of the administration by means of producing hot air at the appropriate temperature. Vessel did not have heat producing gun required by Administration, despite 02 requisition requests to company.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 27 December 2018
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 July 2018
Resolved
01 - Fire protection systems and fire fighting systems and appliances shall be maintained and ready for use. The PSCO found four remote fuel oil quick-closing valves blocked in the open position. The crew explained that two of the valves were blocked in preparation to test with superintendent on 07JUN2018 and forgot to remove. The other two valves have been blocked by previous crew and went unnoticed during monthly tests. The crew would not have been able to isolate fuel oil or diesel oil remotely in the event of a fire in the engine room. - 74/78 SOLAS (2014 CONS.) II-2/14.1.1 - 30ac
Action required: 30 - Ship detained
Resolved 20 July 2018
Resolution: Received class survey stating that the attending surveyor has verified that all blocking devices have been removed from quick closing valves in the engine room and all quick closing valves have been tested and confirmed fully operational.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 July 2018
Resolved
02 - Fire fighting systems shall be maintained ready for use. PSCO found the remote actuator for CO2 discharge valve to the engine room with the safety pin in place. The safety pin must be removed to actuate the valve remotely. the chief engineer explained he forgot to remove after giving familiarization training to the crew on 09JUL2018. - 74/78 SOLAS (2014 CONS) II-2/14.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2018
Resolution: Received class survey stating that the attending surveyor has verified that ship's CO2 firefighting system has been returned to normal operation and is fully operational and ready for use including remote operation.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 July 2018
Resolved
03 - The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea. PSCO observed the rudder hunting five degrees with both pumps operable. Captain stated they use both pumps when maneuvering. - 74/78 SOLAS (2014 CONS) I/11.a - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2018
Resolution: Received class survey stating that a shore technician was arranged and adjustments to the ship's steering system were carried out. The satisfactory operation of the steering system was carried out and verified by the attending surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 17 July 2018
Resolved
04 - The company should establish procedures for key shipboard operations. There are no procedures for testing the vessel's remote quick-closing valves. - 74/78 SOLAS (2014 CONS) XI-I/1 ISM CODE PART A/7 - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 July 2018
Resolution: Class survey states that the company has provided revision to the ship's SMS and provided instructions for testing of ship's remotely operated quick closing valves in the engine room. The SMS revision was verified this time by the attending surveyor.
Electrical › Lighting (emergency) › Outlet Box
Issued 1 January 2018
Resolved
j
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 January 2018
Resolution: Corrected on the spot.