Records in 1988. Most recent: inspection, 25 August 1988.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Documentation
Issued 25 August 1988
Resolved
33CFR155.820 VESSEL OPERATOR HAD NO WRITTEN RECORD AVAILABLE FOR OIL TRANSFER OPERATIONS, SUCH AS NAME OF PERSON IN CHARGE, DATE AND RESULT OF MOST RECENT TEST, HOSE INFORMATION, AND NO DECLARATION OF INSPECTION AS REQUIRED BY 33CFR155.820(A)(B)(C)(D).
Condition: Unknown
Due 26 August 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 25 August 1988
Resolved
33CFR155.430 VESSEL WAS NOT FITTED WITH A STANDARD DISCHARGE CONNECTION FOR THE DISCHARGE TO RECEPTION FACILITY OF OILY WASTES FROM MACHINERY SPACEBILDGES OR FUEL OIL TANK BALLAST WATER AS REQUIRED BY 33CFR155.430(A)(1)(2)(3)(4)(5)(6)(B)(C).
Condition: Unknown
Due 26 August 1988
Resolved 25 August 1988
Construction/Loadline
Issued 25 August 1988
Resolved
33CFR155.360 OILY WATER SEPERATOR NOT CONNECTED BY PIPING OR ELECTRICAL MEANS WHICH WOULD PROVIDE FOR THE PROCESSING OF OILY BILDGE SLOPS OR OILY FUEL OIL TANK BALLAST AS REQUIRED BY 33CFR155.360(A).
Condition: Unknown
Due 26 August 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 25 August 1988
Resolved
33CFR157.12 CARGO MONITOR AND CONTROL SYSTEM NOT DESIGNED FOR TYPE OF CARGO THAT THE VESSEL WAS CARRYING AS REQUIRED BY 33CFR157.12(A).
Condition: Unknown
Due 26 August 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 25 August 1988
Resolved
33CFR151.19 VESSEL DID NOT HAVE AN IOPP CERTIFICATE ON BOARD.......ANY VESSEL OPERATED UNDER THE AUTHORITY OF A COUNTRY OTHER THAN THE UNITED STATES THAT IS PARTY TO MARPOL 73/78 MUST HAVE ON BOARD A VALID IOPP CERTIFICATE WHICH IS REQUIRED BY 33CFR151.19(B).
Condition: Unknown
Due 26 August 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 25 August 1988
Resolved
33CFR155.750 OIL TRANSFER PROCEDURES MISSING LIST OF EACH PRODUCT TRANSFERRED, GENERIC OR CHEMICAL NAME, LINE DIAGRAM OF THE VESSELS OIL TRANSFER PIPING AND LOCATION OF EACH VALVE, PUMP, CONTROL DEVICE, VENT, AND OVERFLOW AS REQUIRED BY 33CFR155.750(1)(I)(2)(I).
Condition: Unknown
Due 26 August 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 25 August 1988
Resolved
CARGO TANK VENTING SYSTEM PIPING HAS HOLES RUSTED THROUGH THEM. FLAME SCRE-EN & WEATHER CAP ON VENT MAST HAVE HOLES RUSTED THROUGH THEM.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Deck/Cargo
Issued 25 August 1988
Resolved
NO RECORD OF HYDROSTATIC TEST OF CARGO PIPING WITHIN LAST YEAR.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Fire Fighting
Issued 25 August 1988
Resolved
MAIN DECK FIRE HOSES NEED RENEWING AND CORRECT FIRE HOSE NOZZLES PROVIDED.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Electrical
Issued 25 August 1988
Resolved
SEVERAL DEAD-ENDED WIRES & WIRES PULLED OUT OF STUFFING TUBES IN ENG. SPACES.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Electrical
Issued 25 August 1988
Resolved
SEVERAL LIGHTS MISSING PROTECTIVE GLOBES & GUARDS.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Deck/Cargo
Issued 25 August 1988
Resolved
NO FLAME SCREENS PRESENT FOR TANK TOPS & ULLAGE OPENINGS ON CARGO TANKS ANDSTBD FUEL OIL VENT.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Deck/Cargo
Issued 25 August 1988
Resolved
RUBBER GASKETING FOR CARGO TANK TOP AND ULLAGE OPENINGS NEED RENEWING
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988