Records from 2008 to 2026. Most recent: inspection, 14 July 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 7.7 ft
Registered tonnagegross 80 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON LA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHARWICHPORT, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Simplified, Net Ton
80 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 33
14 July 2026
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8437941
14 July 2026
Type not recorded
No type recorded · Station Brant Point · USCG Northeast District (CGD-NE) · Activity 8438806
19 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8376403
30 March 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8334173
6 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8265097
6 July 2025
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8178213
6 July 2025
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8178587
15 May 2025
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8136430
13 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7909916
21 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7883025
22 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7692167
13 October 2022
Construction Oversight · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7594522
17 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7449783
15 March 2022
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7349710
8 August 2021
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7282238
8 August 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7283827
22 July 2021
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7265575
22 July 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7407447
1 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7212378
15 July 2020
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7007345
15 July 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7012534
6 May 2020
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6952638
20 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6860201
5 June 2019
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6705306
22 May 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6686280
7 December 2018
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6593672
27 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6524273
21 May 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6417833
26 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6418059
12 May 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6144566
31 March 2017
Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6116941
7 June 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5921132
22 April 2016
Internal Structural Exam · In-Service Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5860327
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 July 2026
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to: Repair of deck or hull planking, plating, and structural members; damage repair or replacement, other than replacement in kind, of propulsion and power supply systems. Vessel loss propulsion during mooring evolution and the port quarter became wedged under the pier. Vessel is to provide a diver report, tech/mechanic report, and Captain's statement prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 15 July 2026
Resolved 15 July 2026
Resolution: Completed sea trial of newly installed throttle control head.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: ...The vessel is outfitted with 02 life buoys with no line. Attach line to one to the satisfaction of the cited regulation.
46CFR 180.70.c.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 17 May 2024
Resolution: Line fitted
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The PFD's were stowed together. A new location was found to separate them. Label the locations IAW 46CFR 185.604.f.
46CFR 180.78.a.5.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 17 May 2024
Resolution: relocated
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. The distribution panel at the operating station is missing blanks to protect from accidental shock. Provide to the satisfaction of the attending marine inspector.
46CFR 183.330.b.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 17 May 2024
Resolution: blank fitted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Both
port and stbd missing screens. Provide IAW regulations.
46CFR 182.450.e.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 17 May 2024
Resolution: screens fitted
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: ...U.S. Coast Pilot [name withheld] Vessel missing both. Provide IAW regulation.
46CFR 184.420.a.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 17 May 2024
Resolution: pubs provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
Fuel lines must be annealed tubing of copper, nickel-copper, or copper-nickel having a minimum wall thickness of 0.9 millimeters (0.035 inch) except that: when used, flexible hose must meet the requirements of 46CFR 182.720(e) of this part. Vessel has conducted a non replacement-in-kind overhaul for the MDE and SSDG's. Vessel no longer exempted by Old T (pre March 1996). Vessel to provide proper installation at next drydock.
46CFR 182.455.a.1.iii.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2026
Resolved 6 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 May 2024
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel was not logging the EPIRB tests. Corrected on the spot by modifying the Drill logs to include EPIRB.
46CFR 185.728.c.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 13 May 2024
Resolved 13 May 2024
Resolution: Ammended log to add.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: ... The negative 12v cable on the STBD SSDG battery bank had come separated from the battery terminal. Corrected on the spot.
46CFR 183.340.g.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 13 May 2024
Resolved 13 May 2024
Resolution: Corrected installation.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 May 2023
Resolved
Vessel's EPIRB battery expired in March of 2023. Attending MI conducted a satisfactory test of the EPIRB during the annual inspection. Vessel may operate the vessel with existing EPIRB for the next 14 day until a new EPIRB or new EPIRB battery is obtained with the following stipulations:
1. Captain must conduct a satisfactory EPIRB test prior to loading passengers.
2. Captain must log each time the EPIR is tested in the vessel's log book.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2023
Resolution: Received an email with a photo of the new EPIRB
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 May 2023
Resolved
Obtain current alcohol testing strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2023
Resolution: received email with photo of new strips
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2020
Resolved
The owner, managing operator, or master shall report damage to a boiler, unfired pressure vessel, or machinery that renders further use of the item unsafe until repairs are made, to the OCMI at the port in which the casualty occurred or nearest the port of first arrival, as soon as practicable after the damage occurs.
Vessel reported loss of propulsion on 2 out of 3 engines. Determine source of loss of propulsion and affect repairs to the satisfaction of the Coast Guard Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2020
Resolution: Repaired to the satisfaction of the attending CGMI; Cleared CG-835V.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: Invalid MMSI and Call Sign from expired FCC License.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 18 September 2018
Resolution: Vessel rep. corrected AIS deficiency.
Lifesaving › Lifefloat › Float-free Link
Issued 21 May 2018
Resolved
Vessel's lifefloats do not have the proper weak links attached for float free arrangement. Provide proper weak links.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 22 May 2018
Resolution: Vessel provided a new weak link for float free arrangement.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 May 2017
Resolved
AVH01: Life buoy lights batteries are exired. Replace batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 23 May 2017
Resolution: Vessel replaced batteries
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 May 2017
Resolved
AVH02: Relocate life jacket donning placard on the 2nd deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 23 May 2017
Resolution: New placards have been installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 May 2017
Resolved
AVH03: Conduct MOB drills prior to carrying passengers, must be logged of min of 5 drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2017
Resolved 23 May 2017
Resolution: drill was conducted satisfactory
Operations/Management › Drills/Instruction › Fire
Issued 12 May 2017
Resolved
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2017
Resolved 23 May 2017
Resolution: drill was conducted satisfactory
Fire Fighting › Structural Fire Protection - General › Column/Stanchion Construction
Issued 22 April 2016
Resolved
Stanchion broken and cracked V/W.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 June 2016
Resolution: Vessel rep V/W the fracture and welded the stanchion back to original design.