Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
25 March 2026
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8331349
5 June 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8152097
22 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8116469
16 May 2024
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7908219
4 May 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7681000
11 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7666379
18 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7531540
29 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7240119
6 May 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7277228
10 August 2020
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7030045
20 May 2019
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6692391
6 May 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6686245
18 October 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6563576
22 May 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6152055
12 May 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6163465
23 June 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5915300
28 April 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5864426
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2024
Resolved
A VESSEL ON WHICH A PRE-ENGINEERED FIXED GAS FIRE EXTINGUISHING SYSTEM IS INSTALLED MUST HAVE THE FOLLOWING AT THE OPERATING STATION; (1) A LIGHT TO INDICATE DISCHARGE (2) AN AUDIBLE ALARM THAT SOUNDS UPON DISCHARGE...DURING INSPECTION, NO AUDIBLE ALARM WAS OBSERVED / HEARD DURING TESTING. REMAINDER OF SYSTEM OPERATED PROPERLY. CONSULT FIRE INSPECTION SERVICE TO REPAIR / REPLACE BY QUALIFIED PERSON.
46 CFR 181.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2024
Resolution: Rcvd satisfactory evidence of Fire-Boy working as designed w/ audible alarm functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 August 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. M/E machinery belt not covered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2022
Resolved 7 September 2022
Resolution: Operator submitted photographs of satisfactory machinery guard installed. See deficiencies documents for uploaded photograph.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 June 2021
Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with 160.050 in subchapter Q of this chapter.
Grab-line: The grab line shall have a minimum breaking strength of 1,350 pounds.
Vessel's grab line was deteriorated. Vessel must replace within 14 days.
Cite: 46CFR180.70(b)(1)/46CFR160.050-3(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2021
Resolved 2 July 2021
Resolution: Vessel provided pictures of new ring life buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 August 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessels first aid kit was not Q spec approved and had expired items.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 26 August 2020
Resolution: Vessel provided receipt for new approved first aid kit.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 19 October 2018
Resolved
Vessel did not have an updated DAPI crew list. Only crew members in compliance may work until a new crew list is provided.
Action required: 705 - Other - as specified
Resolved 20 May 2019
Resolution: Vsl provided updated DAPI crew list
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 October 2018
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is outside scope of annual inspection window and shall complete annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
Resolution: Completed annual inspection.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 22 May 2017
Resolved
Vessle needs to post emergency instructions on vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 2 June 2017
Resolution: Vessel posted emergency instructions.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 22 May 2017
Resolved
Vessel needs to establish passenger count system.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 2 June 2017
Resolution: Vessel established passenger count.