MAURY USCG vessel records Sign in
← All vessels

AMARYNTHOS

AMARYNTHOS is a 1975 freight ship. The Coast Guard has recorded 24 inspections since 1988, most recently in January 1998, along with 52 deficiencies — 2 with no resolution recorded —.

Records from 1988 to 1998. Most recent: inspection, 6 January 1998.

Built
1975
Last inspected
6 January 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7429372 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
316689
Flag
COLOMBIA
—
Maury page id
psix-316689

Inspections, by type

…with no type recorded23
…past their stated due date2
Years with a record 10 calendar years (1988–1998)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6199 - Regulatory (Subpart C or D), Gross Ton
3766 - Regulatory (Subpart C or D), Net Ton
13152 - Displacement, Ton
10171 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

6 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763603
4 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 203178
4 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411447
10 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 404613
7 September 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 395148
1 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 393875
4 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 697508
16 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380047
18 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 697509
15 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 368385
15 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 872634
29 April 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366414
27 April 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358382
26 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14970
31 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 697507
19 January 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1354537
6 December 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 362935
13 December 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355065
12 December 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 12195
20 February 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 492640
25 July 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 345075
20 August 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 338925
23 May 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 337378
5 September 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 325530

Deficiency record · 52

Fire Fighting
Issued 4 January 1998 Resolved
MISSING REQUIRED NUMBER OF FIRE HOSES. NEEDS 17 ON BOARD._x001C_ _x001C_ SOLAS 74(AMENDED) REG II-2/21_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Lifesaving
Issued 4 January 1998 Resolved
STBD LIFE BOAT BRAKE SLIPS WHEN HOLDING THE WEIGHT OF THE BOAT._x001C_ _x001C_ SOLAS 74(AMENDED) REGIII/19.2
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Engineering
Issued 4 January 1998 Resolved
STBD MIDSHIPS FUEL OIL VENT FIXED CONTAINMENT WASTED/HOLED._x001C_ _x001C_ 33 CFR 155.320_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Accommodation/Occupational Safety
Issued 4 January 1998 Resolved
WASTED STEPS ON FORWARD AND AFT LADDERS ON STBD MAIN DECK._x001C_ _x001C_ ILO 147/PSWA_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Engineering
Issued 4 January 1998 Resolved
STBD FUEL OIL PURIFIER MISSING SIGHT GLASS._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Construction/Loadline
Issued 4 January 1998 Resolved
ONE HATCH COVER WASTED THRU ON #3 HOLD._x001C_ _x001C_ ILLC 66 ANNEX I/15_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Lifesaving
Issued 4 January 1998 Resolved
SEVERAL SELF IGNITING LIGHTS INOP._x001C_ _x001C_ SOLAS 60 REG III/21_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Lifesaving
Issued 4 January 1998 No resolution recorded
PORT AND STBD LIFE BOAT DAVIT LIMIT SWITCHES INOP._x001C_ _x001C_ SOLAS 60 REGIII/36(k)_x001C_
Condition: Unknown
Due 4 February 1998 — due date passed with no resolution recorded
Fire Fighting
Issued 4 January 1998 Resolved
UNABLE TO CONDUCT PROPER FIRE DRILL._x001C_ _x001C_ SOLAS 74(AMENDED) REG III/18_x001C_
Condition: Unknown
Due 4 January 1998
Resolved 22 January 1998
Fire Fighting
Issued 4 January 1998 Resolved
EXHAUST LEAK FROM EMERGENCY FIRE PUMP IN PUMP ROOM._x001C_ _x001C_ SLOAS 60 REG I/11_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Engineering
Issued 4 January 1998 Resolved
GENERAL ENGINEROOM HOUSEKEEPING-VERY OILY BILGE, GREASY RAGS, AND LOOSE GEAR. PERSONNEL HAZARDS._x001C_ _x001C_ SOLAS 60 REG II/34_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Navigation
Issued 4 January 1998 No resolution recorded
SEVERAL HYDRAULIC LEAKS IN STEERING ROOM._x001C_ _x001C_ SOLAS 60 REG II/34_x001C_
Condition: Unknown
Due 4 February 1998 — due date passed with no resolution recorded
Unknown
Issued 4 January 1998 Resolved
NUMEROUS TEMP REPAIRS TO HYDRAULIC PIPING ON MAIN DECK._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Construction/Loadline
Issued 4 January 1998 Resolved
FOSCLE BOOM REST AND SUPPORT DAMAGED AND AFT FOCL RAILING._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_ _x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Accommodation/Occupational Safety
Issued 4 January 1998 Resolved
SIX FOOT SECTION OF LIFE RAIL MISSING STBD FANTAIL._x001C_ _x001C_ ILO 147/PWSA
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Lifesaving
Issued 4 January 1998 Resolved
UNSECURED 55 GALLON DRUM SITTING PORT SIDE LOWER ENGINE ROOM/PERSONNEL HAZARD._x001C_ _x001C_ ILO 147/PSWA_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Engineering
Issued 4 January 1998 Resolved
UNABLE TO PROVE PROPER OPERATION OF OWS._x001C_ _x001C_ 33 CFR 155.380(b)_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Fire Fighting
Issued 4 January 1998 Resolved
FIRE MAIN HOLED/WASTED STBD SIDE @ #3 HOLD._x001C_ _x001C_ SOLAS 74(AMENDED) REG II-2/21_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 18 January 1998
Fire Fighting
Issued 1 August 1996 Resolved
VESSELS EMERGENCY FIRE PUMP IS INOPERABLE.
Condition: Unknown
Due 4 August 1996
Resolved 6 August 1996
Documentation
Issued 1 August 1996 Resolved
VESSEL NOT MANNED IN ACCORDANCE WITH SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 4 August 1996
Resolved 6 August 1996
Lifesaving
Issued 1 August 1996 Resolved
VESSEL TO MAKE PROPER AND PERMANENT REPAIRS TO HANDRAILS ON PORT AND STBD LIFEBOATS.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Accommodation/Occupational Safety
Issued 16 June 1995 Resolved
TOILETS INOPERABLE IN CREWS AREA. (ILO 147)
Condition: Unknown
Due 19 June 1995
Resolved 28 June 1995
Accommodation/Occupational Safety
Issued 16 June 1995 Resolved
SCREENS/VENT COVERS MISSING ABOVE THE STOVE IN GALLEY AREA. (ILO 147)
Condition: Unknown
Due 19 June 1995
Resolved 28 June 1995
Electrical
Issued 16 June 1995 Resolved
MISSING LIGHT COVERS/PROTECTION THROUGHTOUT VESSEL. (SOLAS II-1 REG. 45 1.3)
Condition: Unknown
Due 19 June 1995
Resolved 28 June 1995
Navigation
Issued 16 June 1995 Resolved
COAST PILOT (V) OR FOREIGN EQUIVALENT NOT CURRENTLY CORRECTED (EDITION 1993WITH NO CORRECTION). CURRENT COAST PILOT REQUIRED FOR AREA OF TRANSIT._x001C_ (33 CFR 164.33(a)(2)(i)
Condition: Unknown
Due 19 June 1995
Resolved 28 June 1995
Navigation
Issued 16 June 1995 Resolved
NAVIGATIONAL CHART B.A. 3382 WAS NOT CURRENTLY CORRECTED (LAST CRRECTION NOTED 316/94), CURRENT CORRECTION REQUIRED FOR AREA OF TRANSIT. (33 CFR 164.33(a)(1)(ii)
Condition: Unknown
Due 19 June 1995
Resolved 28 June 1995
Documentation
Issued 16 June 1995 Resolved
PROVIDE (1) AB SEAMAN TO MEET MINIMUM MANNING CERTIFICATE. (ILO 147)
Condition: Unknown
Due 16 July 1995
Resolved 28 June 1995
Lifesaving
Issued 15 July 1994 Resolved
Replace the lights on the life rings located on the bridge.
Condition: Unknown
Due 15 July 1994
Resolved 15 August 1994
Navigation
Issued 15 July 1994 Resolved
The Subj Vsl's charts 3847 and 3848 B.A. were not currently corrected. The last correction was (NTM 1992).
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Lifesaving
Issued 15 July 1994 Resolved
Repair the grab rail on the port lifeboat on the outboard side.
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Engineering
Issued 15 July 1994 Resolved
Repair the fixed containment port and stbd for the double bottom fuel oil vents.
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Documentation
Issued 29 April 1994 Resolved
EXPIRED SAFETY EQIPMENT CERTIFICATE.
Condition: Unknown
Due 1 May 1994
Resolved 1 May 1994
Lifesaving
Issued 19 January 1994 Resolved
PROVIDE LINES FOR TWO LIFE RING BUOYS.
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Fire Fighting
Issued 19 January 1994 Resolved
VERIFY ALL FLEXIBLE LOOPS ON CO2 FIXED SYSTEM BOTTLES ARE TIGHT. (4 FOUND LOOSE USING HAND)
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Construction/Loadline
Issued 19 January 1994 Resolved
REPAIR OR PLUG THE TWO OPEN WIRE PENETRATIONS IN THE STARBOARD SIDE OF THE FORECASTLE BULKHEAD.
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Fire Fighting
Issued 19 January 1994 Resolved
PROVIDE PROPER FIREHOSE NOZZLES THAT FIT THE FIREHOSE COUPLINGS._x001C_ (SOME NOZZLES MISSING AND FITTINGS DON'T CONNECT WELL)
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Lifesaving
Issued 19 January 1994 Resolved
DEMONSTRATE OPERATION OF THE MOTOR FOR THE STARBOARD LIFEBOAT. (COULD NOT START DUE TO COLD)
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Lifesaving
Issued 19 January 1994 Resolved
MARK THE HOMEPORT ON THE STARBOARD LIFEBOAT.
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Lifesaving
Issued 19 January 1994 Resolved
PROVIDE ADDITIONAL RETROREFLECTIVE TAPE TO THE GUNWALE OF THE STARBOARD LIFEBOAT. (PARTLY PAINTED OVER)
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Lifesaving
Issued 19 January 1994 Resolved
MAKE ALL FOUR LIFERAFTS AT THE HOUSE FLOAT FREE. (FOUND TIED DOWN, HYDRO RELEASES IN PAINTER CONNECTION)
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Fire Fighting
Issued 19 January 1994 Resolved
PROVIDE COMBINATION FIRE NOZZLES IN THE ENGINEROOM.
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Fire Fighting
Issued 19 January 1994 Resolved
PROVIDE A SECOND SELF CONTAINED BREATHING APPARATUS OR A CYPRUS ACCEPTANCE OF THE FRESH AIR DEVICE. (SECOND SCBA WAS AIR PUMP WITH HOSE, ACCEPTABLE UNDER SOLAS IF ADMIN SAYS SO)
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Fire Fighting
Issued 19 January 1994 Resolved
PROVIDE CYPRUS ACCEPTANCE OF 1974 HYDROTEST OF FIXED CO2 BOTTLES. (SOLAS DOES NOT SPECIFY HYDRO INTERVAL BUT 20 YEARS IS EXCEPTIONALLY LONG, COUPLE BOTTLES HAVE RUSTING NECKS)
Condition: Unknown
Due 20 January 1994
Resolved 22 January 1994
Navigation
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD TIDE CURRENT TABLES AS REQUIRED BY 33 CFR 164.30 (a)(2).
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Navigation
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD COMPLETE MANEUVERING FACT SHEET AS REQUIRED BY33 CFR 164.30 (a)(7).
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Documentation
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.720.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Engineering
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD OPERABLE OILY WATER SEPARATOR AS REQUIRED BY 33 CFR 155.360.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Documentation
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD VALID SOLAS RADIO TELEGRAPHY CERTIFICATE AS REQUIRED BY SOLAS REG 12, CHAPT.1.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Accommodation/Occupational Safety
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD AN OPERABLE MARINE SANITATION DEVICE AS REQUIRED BY 33 CFR 159.7 (c).
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Navigation
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD CHART #11347, 11341 AS REQUIRED BY 33 CFR 164.30(a)(1)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Navigation
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD A COAST GUARD LIGHT LIST OR FOREIGN EQUIVELANTAS REQUIRED BY 33CFR164.30(a)(2).
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Navigation
Issued 23 May 1990 Resolved
VESSEL DID NOT HAVE ON BOARD TIDE TABLES AS REQUIRED BY 33CFR164.30(a)(2)
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.