MAURY USCG vessel records Sign in
← All vessels

CHARLEY

CHARLEY is a 1985 passenger vessel (uninspected). The Coast Guard has recorded 27 inspections since 1989, most recently in July 2025, along with 18 deficiencies.

Records from 1989 to 2025. Most recent: inspection, 10 July 2025.

Built
1985
Last inspected
10 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM3323
317660
Flag
UNITED STATES
368196260
Maury page id
psix-317660

Inspections, by type

…with no type recorded2
Years with a record 21 calendar years (1989–2025)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)51.0 ft × 13.9 ft × 8.1 ft
Registered tonnagegross 28 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDANIEL L STONER · AVILLA, IN, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSUPERIOR, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM3323MMSI 368196260 · active · compulsorily equipped · granted 30 April 2021, expires 30 April 2031
WCQ8251MMSI 367030880 · expired · compulsorily equipped · granted 31 January 2015, cancelled 24 May 2025 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

10 July 2025 Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8182915
15 July 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7958819
17 June 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6985581
2 June 2014 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4870781
4 June 2012 Administrative Inspection · Annual Inspection · Simplified Stability Test · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4326957
9 September 2011 Type not recorded
No type recorded · Station Marblehead · USCG Great Lakes District (CGD-GL) · Activity 4144462
12 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3234996
28 May 2008 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3214347
11 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2958608
29 June 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2695378
1 May 2006 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2621178
20 June 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2396198
12 April 2005 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2332344
5 October 2004 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2214178
16 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2135376
13 January 2004 Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1982871
27 August 2003 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1888623
9 June 2003 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1813407
7 June 2002 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1632689
1 June 2001 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1472695
7 April 2000 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1458743
16 June 1999 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 809980
5 June 1998 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1127690
2 July 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1392723
14 May 1996 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1082374
14 June 1995 Initial Certification · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1353740
18 December 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 923910

Deficiency record · 18

Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 May 2008 Resolved
Provide circuit protection to positive wiring from aux battery to selector switches in accordance with 46 CFR 183.05-15(c).
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 11 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 1 May 2006 Resolved
Repair heat exchanger leaks (2).
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 29 June 2006
Resolution: Repaired the leaks on the exchanger.
Stability › Severe Wind/Roll › General
Issued 1 May 2006 Resolved
Replace froat on fwd mast port side, can temp install through bolt till new froat is ready for installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 29 June 2006
Resolution: Vessels rep repalced the port side froat, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 July 2004 Resolved
Ensure engine room installed fire system instantaneously shuts down the engine upon discharging.
Condition: Improper Installation
Due 16 July 2004
Resolved 16 July 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 June 2004 Resolved
Ensure the installed engineroom fire suppression system instantaneously shuts down the engine upon discharge. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 15 July 2004
Resolved 16 July 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 June 2004 Resolved
Troubleshoot and repair system automatic engine shutdown. LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2004
Resolved 15 June 2004
Communications › Automatic Identification System (AIS)
Issued 10 June 2004 Resolved
Remove expired hydrostatic release and install new one.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2004
Resolved 15 June 2004
Operations/Management › Drills/Instruction
Issued 10 June 2004 Resolved
Conduct man overboard drill to satisfaction of marine inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 10 July 2004
Resolved 15 June 2004
Engineering › Fuel Oil Service System
Issued 10 June 2004 Resolved
Ensure all fuel hoses are double hose clamped. LEGACY COMPONENT DESC: Hose
Due 10 July 2004
Resolved 15 June 2004
Engineering › Fuel Oil Service System
Issued 10 June 2004 Resolved
Label emergency fuel shut-off valve in main cabin. LEGACY COMPONENT DESC: Valve
Due 10 July 2004
Resolved 15 June 2004
Engineering › Fuel Oil Service System
Issued 10 June 2004 Resolved
Install fuel shut-off valve near engine. LEGACY COMPONENT DESC: Valve
Due 10 July 2004
Resolved 15 June 2004
Communications › Radio Communications
Issued 9 June 2003 Resolved
Updated GLA certificate not onboard.
Due 9 July 2003
Resolved 10 June 2003
Resolution: GLA certificate was marina office, owner was never told. It is onboard vessel.
Communications › Radio Communications › EPIRB
Issued 9 June 2003 Resolved
Batteries in EPIRB were outdated. Need to install new batteries in EPIRB.
Due 9 June 2003
Resolved 9 June 2003
Resolution: Owner of vessel purchased new batteries and installed them into EPIRB.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 9 June 2003 Resolved
System would not shutdown engine in the event it was discharged, and the system's visual alarm does not work. Owner needs to ensure system operates properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2003
Resolved 17 July 2003
Resolution: Owner properly wired system to shutdown engine in the event of system discharge. The over ride switch also worked properly.
Electrical › Lighting (service)
Issued 9 June 2003 Resolved
The electrical wires that run up the mast to the light are unapproved extension cord type wires. Owner to renew wires with approved wires.
Due 9 July 2003
Resolved 17 July 2003
Engineering › Steering Gear System
Issued 7 June 2002 Resolved
MOUTNING BOLT FOR RUDDER POST STABILZER SHEARED IN HALF ALLOWING RUDDER POST TO WOBBLE WHEN STEERING CABLE OPERATED. LEGACY COMPONENT DESC: Fastener
Condition: Unknown
Due 7 June 2002
Resolved 7 June 2002
Resolution: REMOVED OLD BOLTS AND REPLACED WITH NEW LONGER STAINLESS STEEL BOLTS.
Engineering
Issued 7 April 2000 Resolved
Fuel Valves: Repipe shut off valves to position them adjacent to fuel tanks prior to operating season 2001.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Engineering
Issued 14 June 1995 Resolved
INSTALL SOUNDING DEVICE IN BOTH FUEL TANKS, EITHER OF AN ELECTRONIC OR A MANUAL TYPE. SUBMIT PLANS TO COGNIZANT [name withheld]._x001C_
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.