Records from 1999 to 2005. Most recent: inspection, 4 October 2005.
Documentation record
Registered dimensions (L × B × D)35.0 ft × 13.0 ft × 5.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH, AL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPENSACOLA, FL
Trade endorsementsFishery
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
15 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
4 October 2005
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2507808
11 January 2005
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2272659
15 January 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1943711
4 September 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1896691
5 March 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1755011
6 January 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1719493
18 December 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1476157
30 October 2001
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1417403
2 August 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1069409
11 January 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825346
4 September 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1047956
4 August 1999
Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1391119
16 June 1999
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424772
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 January 2005
Resolved
Provide proof of enrollment in a drug and alcohol program IAW 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2005
Resolution: Proof of enrollment cards were provided.
Personnel › Training › First Aid/CPR
Issued 28 January 2005
Resolved
Provide proof of CPR/First Aid training for 50% of crew IAW NVIC 1-91
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2005
Resolution: Valid CPR/first aid training cards were provided.
Engineering › Bilge Water Management System › Pump
Issued 28 January 2005
Resolved
Provide proof that at current location of bilge pumps they can effectively pump bilges IAW 46 CFR 182.530(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2005
Resolution: Bilge pumps were moved closer to keel and proved effective.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 January 2005
Resolved
Provide original COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2005
Resolution: Original COI was provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 January 2003
Resolved
Provide proof of servicing of all portable and fixed fire systems.
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 5 March 2003
Resolution: Verified portable and fixed fire fighting systems were serviced.
Navigation › Piloting/Steering
Issued 6 January 2003
Resolved
Provide current navigation publications as per 46 CFR 184.420. LEGACY COMPONENT DESC: Navigation Publications
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 5 March 2003
Resolution: Verified navigation publications were on board.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 January 2003
Resolved
Provide machinery guard on port engine as per 46 CFR 177.960. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 5 March 2003
Resolution: Verified machinery guard was installed.
Engineering › Fuel Oil Service System
Issued 6 January 2003
Resolved
Arrest and/or repair fuel leak on stbd side of engine room as per 46 CFR 176.830. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 5 March 2003
Resolution: Verified fuel leak was repaired.
Lifesaving › Lifejacket/PFD (General)
Issued 6 January 2003
Resolved
Provide additional child lifejacket to bring vessel's total to three, as per COI.
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 6 January 2003
Resolution: Child''''s lifejacket was provided, vessel now has three onboard, as per COI.
Fire Fighting › Means of Escape
Issued 6 January 2003
Resolved
Properly label emergency escape in berthing area as per 46 CFR 185.606 LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 5 March 2003
Resolution: Verified emergency escape was labeled.
Navigation
Issued 30 October 2001
Resolved
PROVIDE NAVIGATION PUBLICATIONS (US COAST PILOT, COAST GUARD LIGHT LIST) AS REQUIRED BY 46 CFR 160.041.
Condition: Unknown
Due 30 November 2001
Resolved 18 December 2001
Lifesaving
Issued 30 October 2001
Resolved
REPLACE EPIRB HYDROSTATIC RELEASE AS REQUIRED BY 46 CFR 185.728 PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 31 October 2001
Resolved 18 December 2001
Resolution: CLEARED.
Documentation
Issued 30 October 2001
Resolved
PROVIDE PROOF OF VALID FCC MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 30 November 2001
Resolved 18 December 2001
Resolution: CLEARED.
Lifesaving
Issued 30 October 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 November 2001
Resolved 18 December 2001
Resolution: CLEARED.
Documentation
Issued 30 October 2001
Resolved
PROVIDE PROOF OF VALID FCC STATION LICENSE.
Condition: Unknown
Due 30 November 2001
Resolved 18 December 2001
Resolution: CLEARED.
Documentation › Certificates/Documents
Issued 30 October 2001
Resolved
Provide valid FCC station license as set forth in 47 CFR Part 80 in accordance with 46 CFR184.502.
Due 30 November 2001
Resolved 18 December 2001
Resolution: Resolved under activity number 1476157
Documentation › Certificates/Documents
Issued 30 October 2001
Resolved
Provide vaild FCC marine radio operator permit as set forth in 47 CFR Part 80 in accordance with 46 CFR 184.502.
Due 30 November 2001
Resolved 18 December 2001
Resolution: Item resolved under activity number 1476157
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 October 2001
Resolved
Provide on board vessel the following navigation publications: U.S. Coast Pilot; CG Light List; Tide Tables; and current tables as required by 46 CFR 184.420.
Due 30 November 2001
Resolved 18 December 2001
Resolution: Item resolved under activity number 1476157.
Communications › Radio Communications › EPIRB
Issued 30 October 2001
Resolved
Renew expired hydrostatic release mechanism to EPIRB. New hydrostatic release shall be installed as per 46 CFR 185.728.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2001
Resolved 18 December 2001
Resolution: Item resolved under activity number 1476157
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 October 2001
Resolved
Renew expired first aid kit contents. First aid kit shall have all items as set forth by 46 CFR 160.041 in accordance with 46 CFR 184.710.
Due 30 November 2001
Resolved 18 December 2001
Resolution: Item resolved under activity number 1476157.
Engineering
Issued 4 August 1999
Resolved
PROVIDE AND INSTALL A GUARD OVER THE PULLY ON THE GENERATOR 46 CFR 182.100
Condition: Unknown
Due 4 September 1999
Resolved 7 April 2000
Accommodation/Occupational Safety
Issued 4 August 1999
Resolved
PROVIDE AND INSTALL A RAIL COURSE ON AFT DECK 46 CFR 177.900
Condition: Unknown
Due 4 September 1999
Resolved 7 April 2000