Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 4.0 ft
Registered tonnagegross 9 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS INC · TARPON SPRINGS, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portPLACIDA, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 4 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
8 - Simplified, Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
7 May 2026
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8368539
12 February 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8305553
9 June 2025
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8153464
17 May 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7912848
2 August 2023
Simplified Stability Test · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7758058
12 June 2023
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7713429
20 October 2022
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7581065
18 October 2022
Damage Survey · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579491
18 November 2021
DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7352969
1 November 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7341975
11 January 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7119142
9 October 2020
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7073697
2 February 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6904738
30 September 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6821422
30 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6616526
31 January 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6346843
25 September 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6272412
3 October 2016
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6014713
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 June 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.(b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication.
Vessel is missing an up to date: navigation chart, light list and coast pilot. Provide evidence of updated documents to the USCG Marine Inspector.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2025
Resolution: Provided evidence of an up to date: navigation chart, light list and coast pilot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
Portable fire extinguishers are missing safety pins and tamper seals. Install safety pins and tamper seals on all portable fire extinguishers onboard the vessel.
46CFR181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2025
Resolution: Installed safety pins and tamper seals on all portable fire extinguishers onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 June 2025
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump.
Vessel is missing (1) portable hand bilge pump. Install a portable hand bilge pump on board the vessel.
46CFR182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2025
Resolution: Installed a portable hand bilge pump on board the vessel.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 June 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements.
The starboard fuel tank vent flame screen is non-satisfactory. Clean, repair, or replace the starboard fuel tank vent flame screen with corrosion resistant wire of at least 30 × 30 mesh.
46CFR182.450
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2025
Resolution: Replaced the starboard fuel tank vent flame screen with corrosion resistant wire of at least 30 × 30 mesh.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 June 2023
Resolved
Vessel is overdue for annual inspection. Vessel must undergo satisfactory inspection by a USCG marine inspector prior to returning to service.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 May 2024
Resolution: Due to the length of time the vessel was out of service, a new full scope COI inspection was conducted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 October 2022
Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 18 October 2022
Resolved 20 February 2024
Resolution: Vessel completed approved satisfactory repairs, credit dry dock granted this date.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2021
Resolved
COI expires 02NOV2021. Do not carry passengers until a satisfactory COI inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2021
Resolved 18 November 2021
Resolution: Completed satisfactory COI inspection.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 January 2021
Resolved
Starboard bilge alarm is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 24 January 2021
Resolution: Received email confirmation that bilge alarm was repaired. A broken wire was found and replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 January 2021
Resolved
Light for ring life buoy is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 24 January 2021
Resolution: New light for ring buoy provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 11 January 2021
Resolved
Replace expired aspirin in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 24 January 2021
Resolution: Aspirin replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 February 2020
Resolved
HIDEAWAY ONE is overdue for the annual inspection, invalidating the COI per 46CFR176.502. Issued CG835, carriage of passengers not authorized.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2020
Resolution: Vessel underwent required Coast Guard inspection.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 February 2020
Resolved
Vessel is required to have up-to-date publications, vessel has publications over 3 years old, must provide proof of obtaining up-to-date publications onboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 20 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 February 2020
Resolved
Vessel is required to provide two portable battery lights one at op station and one near machinery station. Vessel does have any portable lighting (flashlights). Must provide proof obtaining and outfitting of two flashlights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 20 February 2020
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 2 February 2020
Resolved
Vessel does not have required MARPOL V (Garbage) Placard posted. Vessel must provide proof of obtaining and posting MARPOL V Placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 20 February 2020
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 January 2018
Resolved
COD is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2018
Resolution: COD has been updated and posted to MISLE.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 31 January 2018
Resolved
B-II fire extinguisher cylinder is wasted at neck and bottom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2018
Resolution: New extinguisher purchased and mounted.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 January 2018
Resolved
2017 emergency drills not logged.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 20 February 2018
Resolution: Received email from vessel representative drill logs have been started.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 January 2018
Resolved
Ring buoy grab line and life line are frayed/breaking.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 1 February 2018
Resolution: Approved ring buoy purchased with new grab and life lines.
Navigation › Piloting/Steering › Marine Charts
Issued 31 January 2018
Resolved
Correct charts to lastest notice to mariners.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 26 February 2018
Resolution: Received emailed copy of chart invoice.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 January 2018
Resolved
Provide current first aid kit.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 20 February 2018
Resolution: First aid kit purchased.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 31 January 2018
Resolved
Provide lastest MIS report.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 20 February 2018
Resolution: Latest MIS report provided.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 31 January 2018
Resolved
Provide EAP policy statement, substance abuse professional contact, and hotline number.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 20 February 2018
Resolution: EAP policy statement, and substance abuse professional contact, and hotline number all provided.