MAURY USCG vessel records Sign in
← All vessels

DANICA RAINBOW

DANICA RAINBOW is a 1987 freight ship. The Coast Guard has recorded 55 inspections since 1988, most recently in February 2026, along with 31 deficiencies — 1 with no resolution recorded — and 13 operational controls, 1 with no removal date recorded.

Records from 1988 to 2026. Most recent: inspection, 17 February 2026.

Built
1987
Last inspected
17 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8503979 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
317755
Flag
DENMARK
—
Maury page id
psix-317755

Inspections, by type

…with no type recorded38
…past their stated due date1
Years with a record 15 calendar years (1988–2026)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1087 - Convention (Subpart B), Gross Ton
584 - Convention (Subpart B), Net Ton
1784 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 55

17 February 2026 PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8308850
27 February 2022 PSC B · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7399093
27 February 2022 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7399724
29 August 2021 PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7299403
11 June 2019 ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6705364
11 June 2019 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6705471
10 June 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6704391
1 May 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6672366
22 March 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6647155
23 January 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6613845
8 December 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6594118
24 October 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6567121
14 September 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6540363
14 August 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6511525
14 July 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6478975
3 May 2018 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6404479
27 April 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6400497
23 March 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6377209
9 February 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6351631
8 January 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6334217
10 December 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6321576
23 August 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6249607
25 June 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6185914
8 May 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6141488
7 April 2017 Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6119801
27 February 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6095686
20 October 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6026490
7 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5994218
14 June 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5906826
9 December 2015 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5778034
28 August 2015 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5228931
15 December 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4204462
15 December 2011 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4208853
14 December 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4204208
22 July 2011 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4090197
3 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3936099
1 January 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3918915
10 December 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3907857
8 November 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3887286
2 November 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3883578
2 October 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3860297
2 September 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3840187
1 September 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3838634
10 March 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3691863
6 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3674365
3 February 2010 Type not recorded
No type recorded · USCGC LEGARE (WMEC 912) · Activity 3697345
6 August 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 292485
23 October 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 421904
31 October 1997 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 409342
22 April 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 204978
22 April 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 756660
21 April 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 402634
27 September 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 395907
26 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395782
17 September 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 325689

Deficiency record · 31

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 February 2026 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed a junction box improperly installed in paint locker.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2026
Resolved 4 March 2026
Resolution: Sector North Carolina Port State Control shop received pictures as proof that the vessel personnel installed a compliant junction box within the paint locker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 February 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed fuel tank vents missing flame screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2026
Resolved 4 March 2026
Resolution: Sector North Carolina Port State Control shop received pictures as proof that the vessel personnel fitted functional flame screens onto the vessels fuel tank vents.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 17 February 2026 Resolved
Every ship of 400 gross tonnage and above shall be provided with an oil record book Part I. The oil record book shall be in the form specified. No weekly soundings of the sludge tank between the dates 22JUL25 through 10SEP25.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 March 2026
Resolution: Vessels Class, PRS, conducted a survey of the vessel finding that the vessels Oil Record Book were checked and found to be in accordance with class.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 17 February 2026 Resolved
Oil residue (sludge) tank(s) shall be provided and shall be of adequate capacity, having regard to the type of machinery and length of voyage, to receive the oil residues (sludge) which cannot be dealt with otherwise in accordance with the requirements of this Annex. Oil record book entries on 23APR2025 and 08MAY2025 show the vessel pumped to drums on deck, due to not having adequate space with in the sludge tank.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 March 2026
Resolution: Vessels Class, PRS, conducted a survey of the vessel finding that the vessel operated in accordance with class having filled and then emptied the related drums with sludge.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 27 February 2022 Resolved
THE RUDDDER ANGLE INDICATOR WAS OFF BY MORE THAN 15 DEGREES PORT AND STBD 74SOLAS(20)II-1/REG 29/11.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 29 August 2021 Resolved
The rescue boat embarkartion and launching arrangments shall be such that the rescue boat can be board and launched in the shortest possible time. Rescue boat is unable to be launched in a timely manner. Additionally, crew has put patches on areas around the inflatable not approved by class.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 September 2021
Resolved 3 September 2021
Resolution: Class report was completed, and witnessed satisfactory test of launching requirements of the rescue boat
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 August 2021 No resolution recorded
The frequency of bunkerline tests and inspections required by this section must be, for vessels, annually or as part of mid period inpsections. Vessel has not tested bunker line for a pressure test.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 September 2021 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 April 2017 Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over 35 degrees on one side to 35 degrees on the other side with the ship at its deepest seagoing draught. Vessel unable to prove steering system could operate from 35 degrees to 35 degrees on the other side. 74 cons.97 II-I/29.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Received attestation for repairs, witnessed full operational test of rudder.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 March 2017 Resolved
0750 - Fire Prevention - Any fixed fire detection system shall be capable of immediate operation at all times. Smoke detection in engine room over generator #2 on starboard side is inoperable. - 74 SOLAS (97 Cons.) Ch.II-2/Reg.13.7.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Received attestation for repairs, witnessed operational test.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 March 2017 Resolved
0999 - Other(Safety in General) - Machinery shall be installed and protected to reduce to a minimum any danger to persons on board from moving parts. Fresh water pump located between the ladder and OWS on the starboard side engine room is missing a guard to protect from the belt. - 74 SOLAS (97 Cons.) Ch.II-1/Reg.26.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 April 2017
Resolution: Received attestation for repairs, sighted new guard in place.
Engineering › Generator (propulsion-electric) › Indicator Circuitry
Issued 7 March 2017 Resolved
1499 - Other(Prop. & Aux. Machinery) - The condition of the ship and its equipment shall be maintained to conform with the current regulations to ensure that the ship remains fit to proceed to sea without danger to the ship or persons on board. RPM gauges on both generators 1,2 in engine room inoperable - 74 SOLAS (97 Cons.)Ch.I Reg.11(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 April 2017
Resolution: Received attestation, indicators on bridge operational, local gauges removed.
Construction/Loadline › Markings › Winter Load Line
Issued 7 March 2017 Resolved
1220 - Freeboard Marks - The lines which indicate the loadline assignment shall be in accordance with Reg 6 of the ICLL of 1966. The winter mark is marked with a "V" and does not match the "W" on the certificate. - ICLL 66 Annex I/Reg.6
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 April 2017
Resolution: Received attestation for repairs.
Construction/Loadline › Hull › Girder
Issued 14 December 2015 Resolved
0938 - Hull Damage Impairing - The condition of the ship and its equipment shall bemaintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. Starboard aft quarter of the stern outside of the steering gear room has a significant sized inset effecting multiple frames. - 74 SOLAS '14 con. CH. I Reg. 11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Resolution: Class attestation provided (see attached class document). Per class attestation "indentation to be addressed during nearest drydocking by placing an insert. Indentation at present stage creates no hazard to the ships hull integrity and ships safety."
Lifesaving › Lifebuoys › Immediately Available
Issued 14 December 2015 Resolved
0650 - Lifebouys - All lifebouys shall be so placed as to be readily accessible to the persons onboard and shall be capable of quick release from the navigation bridge. The port side quick release lifebouy is blocked by the rescue boat. - 74 SOLAS 97 cons. CH. III Reg. 7.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Resolution: Class provided attestation (see attached class document). "Rescue boat was moved about 2.5ft towards SB creating this way easy access to the lifebouy."
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 14 December 2015 Resolved
1551 - Signaling Lamp - A daylight signaling lamp shall be equiped using an energy source of electrical power not solely dependent upon the ships power supply. The daylight signaling lamp doesnt have an independent power supply. 74 SOLAS 14 cons. CH. V Reg. 19.2.2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2015
Resolution: Class issued attestation. (see attached class document)"Surveyor checked both PS and SB bridge sockets supplying power to Aldis Lamps and found them being fed from independent 24V power source from emergency batteries.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 9 December 2015 Resolved
0710 - Fire Prevention - In a ship in which oil fuel is used, the arrangements for the utilization of the fuel shall be such as to ensure the safety of the ship and persons on board. There was fuel leak found on the supply piepline for the port auxilary generator in the engine room. 74 SOLAS 97 cons. CH II-2 Reg. 15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2015
Resolution: Class attestation provided (see attached class document). "Surveyor did check on the issue and found new fuel pump installed and leak eliminated."
Operations/Management › Drills/Instruction › Abandon Ship
Issued 14 December 2011 Resolved
Each crewmember is required to participate in one abandon ship drill every month in accordance with 74SOLASIII/19.3.3. The vessel has not conducted an abandon ship drill since 07 AUG 2011.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2011
Resolved 14 December 2011
Resolution: Vessel conducted a satisfactory abandon ship drill on 14DEC11.
Operations/Management › Drills/Instruction › Fire
Issued 14 December 2011 Resolved
Each Crewmember is required to participate in one fire drill each month as required by 74SOLASIII/19.3.3. The vessel has not conducted a fire drill since 07AUG 2011.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2011
Resolved 14 December 2011
Resolution: Vessel conducted a satisfactory fire drill on 14 DEC 2011.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 14 December 2011 Resolved
Before the ship leaves port, and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use in accordance with 74SOLASIII/20.2. The rescue boat cannot be started.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2011
Resolved 15 December 2011
Resolution: Vessel installed new engine on the rescue boat. All sat.
Navigation › Piloting/Steering › Gyro Compass
Issued 22 July 2011 Resolved
Ships of 500 GT and over constructed on or after 1984 shall be fitted with a gyrocompass. The master gyro or a gyro repeater shall be clearly readable by helmsman. Gyrocompass on vessel is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2011
Lifesaving › Rescue Boat › Hull (inflated)
Issued 8 November 2010 Resolved
RESCUE BOAT HAS A LEAK AND CANNOT SUSTAIN ITS AIR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2010
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 8 November 2010 Resolved
Vessel departed Gonaives, Haiti on 30OCT10 (1800) inbound for COTP zone Miami, Miami River. ENOA submitted 01NOV10 (2258). Vessel entered anchorage 03NOV10 (0900). Vessel failed to submit ENOA prior to departure for a voyage of less than 96 hours in duration.
Due 8 November 2010
Resolved 11 March 2011
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 6 August 2001 Resolved
Update Fire Control Plan to indicate paint locker location to satisfaction of Class.
Condition: Unknown
Due 6 September 2001
Resolved 3 August 2010
Navigation
Issued 31 October 1997 Resolved
Correct applicable charts, Coast Pilot, and Light List prior to departure.
Condition: Unknown
Due 9 November 1997
Resolved 6 November 1997
Fire Fighting
Issued 31 October 1997 Resolved
Install self closing devices on doors in stairwells between decks IAW SOLAS74, Chapter II-2, regulation 46.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 31 October 1997 Resolved
Provide proper stowage area for flammables.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Construction/Loadline
Issued 21 April 1997 Resolved
SOLAS II-2/42.4: MAIN ENGINE EXHAUST TRUNK, STBD SIDE MAIN DECK FRACTURED AND WASTED. CLASS TO ADDRESS AND RECOMMEND REPAIRS NOT LATER THAN 15AUG97.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Navigation
Issued 27 September 1996 Resolved
Provide emergency steering instructions in English and working language in steering gear compartment, prior to next US port.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Documentation
Issued 27 September 1996 Resolved
Provide original certificate of financial responsibility prior to next US port; non-certified copy onboard at time of boarding.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Documentation
Issued 17 September 1988 Resolved
A VIOLATION OF 33 CFR 155.450 IN THAT THE VESSEL DID NOT HAVE THE REQUIRED POLLUTION PREVENTION PLACARD POSTED.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Documentation
Issued 17 September 1988 Resolved
A VIOLATION OF 33 CFR 130.1(A)(1) IN THAT THE VESSEL DID NOT HAVE ON BOARD A CERTIFICATE OF FINANCIAL RESPONSIBILITY. VESSEL DID PROVIDE PROOF OF APPLICATION AND A VALID CERTIFICATE NUMBER.
Condition: Unknown
Due 20 September 1988
Resolved 17 September 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.