MAURY USCG vessel records
← All vessels

DANICA RAINBOW

DANICA RAINBOW is a 1987 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in February 2026, along with 12 deficiencies — 1 with no resolution recorded — and 3 operational controls, 1 with no removal date recorded.

Records from 2016 to 2026. Most recent: inspection, 17 February 2026.

Built
1987
Last inspected
17 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 February 2026
…with no type recorded18
…past their stated due date1
Operational controls 1 with no removal date recorded
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8503979
317755
Flag
DENMARK
Maury page id
psix-317755

Documentation record

Tonnage as PSIX records it1087 - Convention (Subpart B), Gross Ton
584 - Convention (Subpart B), Net Ton
1784 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

17 February 2026 PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8308850
27 February 2022 PSC B · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7399093
27 February 2022 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7399724
29 August 2021 PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7299403
11 June 2019 ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6705364
11 June 2019 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6705471
10 June 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6704391
1 May 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6672366
22 March 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6647155
23 January 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6613845
8 December 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6594118
24 October 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6567121
14 September 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6540363
14 August 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6511525
14 July 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6478975
3 May 2018 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6404479
27 April 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6400497
23 March 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6377209
9 February 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6351631
8 January 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6334217
10 December 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6321576
23 August 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6249607
25 June 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6185914
8 May 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6141488
7 April 2017 Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6119801
27 February 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6095686
20 October 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6026490
7 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5994218
14 June 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5906826

Deficiency record · 12

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 February 2026 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed a junction box improperly installed in paint locker.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2026
Resolved 4 March 2026
Resolution: Sector North Carolina Port State Control shop received pictures as proof that the vessel personnel installed a compliant junction box within the paint locker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 February 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed fuel tank vents missing flame screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2026
Resolved 4 March 2026
Resolution: Sector North Carolina Port State Control shop received pictures as proof that the vessel personnel fitted functional flame screens onto the vessels fuel tank vents.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 17 February 2026 Resolved
Every ship of 400 gross tonnage and above shall be provided with an oil record book Part I. The oil record book shall be in the form specified. No weekly soundings of the sludge tank between the dates 22JUL25 through 10SEP25.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 March 2026
Resolution: Vessels Class, PRS, conducted a survey of the vessel finding that the vessels Oil Record Book were checked and found to be in accordance with class.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 17 February 2026 Resolved
Oil residue (sludge) tank(s) shall be provided and shall be of adequate capacity, having regard to the type of machinery and length of voyage, to receive the oil residues (sludge) which cannot be dealt with otherwise in accordance with the requirements of this Annex. Oil record book entries on 23APR2025 and 08MAY2025 show the vessel pumped to drums on deck, due to not having adequate space with in the sludge tank.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 March 2026
Resolution: Vessels Class, PRS, conducted a survey of the vessel finding that the vessel operated in accordance with class having filled and then emptied the related drums with sludge.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 27 February 2022 Resolved
THE RUDDDER ANGLE INDICATOR WAS OFF BY MORE THAN 15 DEGREES PORT AND STBD 74SOLAS(20)II-1/REG 29/11.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 29 August 2021 Resolved
The rescue boat embarkartion and launching arrangments shall be such that the rescue boat can be board and launched in the shortest possible time. Rescue boat is unable to be launched in a timely manner. Additionally, crew has put patches on areas around the inflatable not approved by class.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 September 2021
Resolved 3 September 2021
Resolution: Class report was completed, and witnessed satisfactory test of launching requirements of the rescue boat
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 August 2021 No resolution recorded
The frequency of bunkerline tests and inspections required by this section must be, for vessels, annually or as part of mid period inpsections. Vessel has not tested bunker line for a pressure test.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 September 2021 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 April 2017 Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over 35 degrees on one side to 35 degrees on the other side with the ship at its deepest seagoing draught. Vessel unable to prove steering system could operate from 35 degrees to 35 degrees on the other side. 74 cons.97 II-I/29.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Received attestation for repairs, witnessed full operational test of rudder.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 March 2017 Resolved
0750 - Fire Prevention - Any fixed fire detection system shall be capable of immediate operation at all times. Smoke detection in engine room over generator #2 on starboard side is inoperable. - 74 SOLAS (97 Cons.) Ch.II-2/Reg.13.7.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2017
Resolution: Received attestation for repairs, witnessed operational test.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 March 2017 Resolved
0999 - Other(Safety in General) - Machinery shall be installed and protected to reduce to a minimum any danger to persons on board from moving parts. Fresh water pump located between the ladder and OWS on the starboard side engine room is missing a guard to protect from the belt. - 74 SOLAS (97 Cons.) Ch.II-1/Reg.26.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 April 2017
Resolution: Received attestation for repairs, sighted new guard in place.
Engineering › Generator (propulsion-electric) › Indicator Circuitry
Issued 7 March 2017 Resolved
1499 - Other(Prop. & Aux. Machinery) - The condition of the ship and its equipment shall be maintained to conform with the current regulations to ensure that the ship remains fit to proceed to sea without danger to the ship or persons on board. RPM gauges on both generators 1,2 in engine room inoperable - 74 SOLAS (97 Cons.)Ch.I Reg.11(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 April 2017
Resolution: Received attestation, indicators on bridge operational, local gauges removed.
Construction/Loadline › Markings › Winter Load Line
Issued 7 March 2017 Resolved
1220 - Freeboard Marks - The lines which indicate the loadline assignment shall be in accordance with Reg 6 of the ICLL of 1966. The winter mark is marked with a "V" and does not match the "W" on the certificate. - ICLL 66 Annex I/Reg.6
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 20 April 2017
Resolution: Received attestation for repairs.