MAURY USCG vessel records
← All vessels

FT. MORGAN

Built
1988
Last inspected
4 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 June 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE4893
318121
Flag
UNITED STATES
Maury page id
psix-318121

Documentation record

Registered dimensions (L × B × D)140.0 ft × 30.0 ft × 7.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD INDUSTRIES, INC · MORGAN CITY, LA, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOBILE, AL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 41 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 41

4 June 2026 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8369386
28 June 2025 Damage Survey · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8169279
28 June 2025 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8227114
17 June 2025 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8160972
27 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8133224
2 January 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8056687
22 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7917356
25 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7696604
11 January 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619974
31 October 2022 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7592768
1 September 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7552374
18 July 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7510327
5 July 2022 Administrative Inspection · In-Service Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7504023
25 June 2022 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7486615
4 June 2022 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7477198
2 May 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7448939
9 August 2021 Administrative Inspection · Damage Survey · Examination of Repairs · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7282261
9 August 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7282811
7 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7191774
7 January 2021 Drydock Exam · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7138291
13 June 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6976995
13 June 2020 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6985027
4 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6948112
9 March 2020 Examination of Repairs · In-Service Inspection · Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6922937
8 March 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6923139
18 December 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6955476
8 November 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6851999
13 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6682808
7 February 2019 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6621988
29 June 2018 Deficiency Check · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6459434
28 June 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6469673
25 June 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6456405
14 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6414092
15 August 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6241802
23 February 2017 Examination of Repairs · COI Inspection · Internal Structural Exam · Hull Examination · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6093729
12 October 2016 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6021938
11 October 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6019947
10 June 2016 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5906168
26 January 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5803799
22 January 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5801969
12 January 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796028

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 June 2026 Resolved
On vessels carrying vehicles, suitable chains, cable, or other barriers shall be installed at the ends of each vehicle runways. MI observed a 6 foot crack on the hinged plate of the ferry vessel's ramp. Vessel is restricted from on loading & off loading vehicles on the cracked ramp until permanent repairs are affected. Submit a permanent repair proposal for MI review within 7 days. 46 CFR 177.35-10 (a) (Old-T)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 June 2026
Resolution: Recieved repair report and attended to verify SAT repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 June 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel operator reported loss of propulsion due to broken propeller shaft for #2 aft engine. Repair propeller shaft to the satisfaction of the Marine Inspector. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2025
Resolution: Sea trials were conducted of the new shaft underway, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2025 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Vessel experienced loss of steering at the dock. Prior to departure, vessel will repair and O/O will demonstrate proper operation of steering system to satisfaction of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2025
Resolution: Satisfactory sea trials in 8169279 completed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 May 2025 Resolved
A hatch exposed to the weather must be watertight. MI observed that the gaskets on the engine room escape hatches were damaged. 46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 9 June 2025
Resolution: Received photo evidence of new gaskets installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2025 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. MI observed that the generator fuel filter was missing a bowl.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 9 June 2025
Resolution: Received photo evidence of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2025 Resolved
All safety and relief valves for use on pressure vessels or piping systems must be designed to meet the protection and service requirements for which they are intended and must be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel or piping system. MI was unable to verify the setting on the on the air compressor's safety relief valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 9 June 2025
Resolution: Received photo evidence of new safety relief valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 May 2023 Resolved
Flexible nonmetallic hose must meet SAE J-1942 or be specifically approved by the Commandant. Fuel hose on generator was not marked. Replace fuel hose with approved hose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2023
Resolved 28 June 2023
Resolution: New fuel lines installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 October 2022 Resolved
Shaft cutlass bearing interior rubber was missing thus allowing the shaft to have excessive movement with no support.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2022
Resolved 31 October 2022
Resolution: Deficiencies rectified and documenarty evidence provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2022 Resolved
Need to conduct Sea Trials with CG onboard prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2022
Resolved 25 July 2022
Resolution: Witnessed sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel fwd shaft broke. Vessel shall not depart pier in Dauphin Island until shipyard and transit plan are approved by a Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2022
Resolution: Shaft repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2020 Resolved
At approximately 1718 on 13JUN2020 the Ft. Morgan ferry suffered a loss of propulsion. All main propulsion machinery is required to be maintained so as to prevent machinery failure. Provide technician's report indicating adequate repairs have been completed and that the engine is fully operational prior to the carriage of passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2020
Resolved 30 June 2020
Resolution: Vessel was operationally tested to the satisfaction of the attending inspectors to ensure M/E was fully functional after top end overhaul
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2020 Resolved
01-13199-A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Vessel struck debris and sheered bolts causing the rudder to be inoperable.-46CFR182.610(a)(1)- 17C
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2020
Resolved 10 March 2020
Resolution: Replaced all bolts with grade 8 bolts.
Engineering › Fuel Oil Service System › Hose
Issued 14 May 2018 Resolved
Fule hose on both generators does not meet SAE J-1942 and does not have apprpriate hose end fittings. Provide proper hoses and fittings.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 25 June 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 May 2018 Resolved
Battery terminals are secured with wing nuts. Provide permanent type connections.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 25 June 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 May 2018 Resolved
Dead end wire passing through machinery/steering bulkhead. remove dead end wire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 25 June 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 14 May 2018 Resolved
MMSI not programmed into VHF radio installation. Provide proof of programming and GPS integration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 25 June 2018
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 30 May 2017 Resolved
Both engines gauges in engine room need to be operational. IAW 46 CFR 182.20-5(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 27 June 2017
Resolution: Vessel replaced J/W temp gauge with new, sat.
Electrical › Electric Generation Source (emergency) › Overcurrent Device
Issued 30 May 2017 Resolved
Show proof of both generators being properly derated and provide name plate for emergency generator. IAW 46 CFR 183.10-5/10-5(f)(2)
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 15 August 2017
Resolution: Attested to the de-rating of generators and plate placement.
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 May 2017 Resolved
Need updated Coast Pilot. IAW 46 CFR 184.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 27 June 2017
Resolution: Vessel provided current Coast Pilot.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 30 May 2017 Resolved
Need company drug policy onboard, Employee Assistance information posted and proof of supervisor training. IAW 46 CFR 16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 27 June 2017
Resolution: Vessel rep provided documentation for DAPI program.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 October 2016 Resolved
Wastage found in watertight bulkhead between fwd port engine room and fwd port ballast tank. Make temporary repairs to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2016
Resolved 14 October 2016
Resolution: Temporary repair made via doubler plate.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 October 2016 Resolved
Wastage found in watertight bulkhead between fwd port engine room and fwd port ballast tank. Make permanent repairs to the satisfaction of attending CG Marine Inspector at next scheduled dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 19 May 2017
Resolution: wasted area cropped and renewed. Tested via soap and blow.

Ownership record