Records from 2001 to 2004. Most recent: inspection, 21 October 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
21 October 2004
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2225181
25 August 2003
In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1890596
4 December 2002
In-Service Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1714071
7 September 2002
Quarterly Examination · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1662191
21 May 2002
Quarterly Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1616427
6 April 2002
Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1601373
5 April 2002
Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1601387
25 March 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1597928
21 February 2002
Control Verification · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1487990
27 January 2002
Periodic Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1488331
1 November 2001
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1076445
29 October 2001
Quarterly Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1376808
15 October 2001
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1074911
26 July 2001
MARPOL Annex I Examination · Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366491
18 July 2001
MARPOL Annex I Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1370297
Lifesaving
Issued 29 November 2002
No resolution recorded
Prior to carrying passengers but in no case later than January 15, 2003 make permanent repairs to Starboard aft MES Bosn line where it is hanging up on the catwalk support.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2003 — due date passed with no resolution recorded
Lifesaving
Issued 29 November 2002
No resolution recorded
Prior to carrying passengers but in no case later than January 15, 2003 provide current servicing certificates for all four MES units.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2003 — due date passed with no resolution recorded
Documentation › Certificates/Documents
Issued 29 November 2002
No resolution recorded
Prior to carrying passengers but in no case later than January 15, 2003 provide proof of current Certificate of Registry.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2003 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 7 September 2002
Resolved
Prior to carrying passengers in accordance with plans submitted to class society provide class report verifying satisfactory completion of modifications of vessel.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 September 2002
Resolved
Prior to carrying passengers provide class society report verifying proper medical facility and supplies. LEGACY COMPONENT DESC: Hospital Space
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 19 February 2002
Resolved
Bulkhead sheathing at starboard mezzanine deck/amidships was damaged by shifting cargo and presents a safety hazard.
Action required: 705 - Other - as specified
Resolved 21 May 2002
Resolution: During first Quarterly Control Verification Exam noted repaired bulkhead sheathing at starboard mezzanine deck amidships.
Communications › Alarms/Indicators
Issued 19 February 2002
Resolved
The general alarm rotating beacon in the port upper generator room is not working. LEGACY COMPONENT DESC: General Alarm
Action required: 15 - Rectify deficiencies by next port
Resolved 25 March 2002
Resolution: Cleared by [name withheld] Guam
Fire Fighting
Issued 1 November 2001
Resolved
PROVE/PROVIDE FIRE RATING FOR FLEXIBLE HOSES USED IN CARGO DECK FIXED FIRE FIGHTING SPRINKLER SYSTEM.
Condition: Unknown
Due 3 November 2001
Resolved 12 September 2002
Fire Fighting
Issued 26 July 2001
No resolution recorded
PROVE THAT "FIRE LOADS" IN AREAS CONTAINING CREW'S BERTHING AND THE DOCTOR'S BERTH IS NO HIGHER THAN ALLOWED FOR CATEGORY "C" SPACES.
Condition: Unknown
Due 26 October 2001 — due date passed with no resolution recorded
Lifesaving
Issued 26 July 2001
Resolved
MAKE PROPER REPAIRS TO DECK PLATING, PORT, AFT CARGO DECK. REPAIRS TO BE COMPLETED TO SATISFACTION OF FLAG STATE.
Condition: Unknown
Due 26 October 2001
Resolved 19 February 2002
Resolution: Conducted hose test of area, no leaks detected.
Engineering
Issued 26 July 2001
Resolved
INSTALL SFP TO RAW WATER PIPING UNDER ALL GENERATORS (12" IN LENGTH)
Condition: Unknown
Due 26 October 2001
Resolved 19 February 2002
Resolution: Piping satisfactorily insulated
Fire Fighting
Issued 26 July 2001
No resolution recorded
SUBMIT PROPOSAL TO USCG MSC FOR STRUCTURAL FIRE PROTECTION OF STORAGE ROOMS, LOGISTICS OFFICE AND PORT, AFT STAIRTOWER STOREROOMS.
Condition: Unknown
Due 26 October 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 26 July 2001
Resolved
PROVE/PROVIDE FIRE RATING FOR FLEXIBLE HOSES USED IN CARGO DECK FIXED FIRE FIGHTING SPRINKLER SYSTEM.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Lifesaving
Issued 26 July 2001
No resolution recorded
USCG INSPECTOR IS TO BE PRESENT DURING NEXT SCHEDULED TEST OF MARINE EVACUATION SYSTEM (MES).
Condition: Unknown
Due 30 April 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 26 July 2001
Resolved
INSTALL DRAIN PORT "BLIND ENDS" IN FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 26 October 2001
Resolved 12 September 2001
Documentation
Issued 26 July 2001
Resolved
PROVIDE FINITE ELEMENT MODEL OF VARIOUS BRACKET DETAILS.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Fire Fighting
Issued 26 July 2001
Resolved
SUBMIT CLASSIFICATION SOCIETY APPROVAL LETTER FOR FIRE DOORS IN CLASS "A" SPACES. CURRENT DOORS ARE NOT SELF CLOSING.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001