MAURY USCG vessel records Sign in
← All vessels

GESHICA

GESHICA is a 1988 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1988, most recently in November 2025, along with 84 deficiencies.

Records from 1988 to 2025. Most recent: inspection, 21 November 2025.

Built
1988
Last inspected
21 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

318600
Flag
UNITED STATES
—
Maury page id
psix-318600

Inspections, by type

…with no type recorded4
Years with a record 35 calendar years (1988–2025)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 70

21 November 2025 Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8272633
8 September 2025 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8190770
8 October 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8016166
16 September 2024 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8004258
5 August 2024 Deficiency Check · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7975402
13 December 2023 Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7838888
11 December 2023 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7837330
19 December 2022 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7611485
8 December 2022 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7606110
22 October 2022 Deficiency Check · In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7583408
18 July 2022 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7509768
9 December 2021 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7367777
8 September 2020 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7053033
8 May 2020 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6950219
13 December 2019 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6873271
4 December 2018 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6591221
2 September 2018 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 6533908
5 April 2018 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6430633
6 November 2017 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6303822
23 November 2016 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6047255
16 March 2016 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5853233
20 October 2015 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5746595
2 September 2015 DAPI Audit · COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5231003
5 June 2014 DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4880008
19 March 2014 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4818926
6 March 2014 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4810900
17 August 2011 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4118547
5 March 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3690320
23 July 2009 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3543381
25 June 2008 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3253236
14 February 2008 Hull Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3150915
12 July 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2998356
28 June 2006 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2696136
28 February 2006 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2599096
11 July 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2422666
11 May 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2356004
9 February 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2292023
16 July 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2137979
5 February 2004 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2001564
25 November 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1956780
29 July 2003 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1862739
26 August 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1675087
11 July 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1647733
16 January 2002 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1488391
18 September 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1415716
7 July 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1386846
26 January 2000 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1048109
16 December 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375999
5 November 1999 Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388952
26 August 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1449228
6 November 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1434798
8 January 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364515
8 January 1998 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372087
26 November 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1453429
5 November 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1407994
23 September 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375119
26 June 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460967
1 November 1995 Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1402106
20 September 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370918
30 September 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354546
21 September 1993 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1452974
5 March 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1145632
26 October 1992 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1359458
22 August 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 229087
23 October 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 937111
11 September 1991 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1245072
3 October 1990 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1211128
3 October 1989 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1323320
31 August 1989 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1044159
14 September 1988 Initial Certification · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1194602

Deficiency record · 84

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 December 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed annual inspection window, vessel cannot operate until annual inspection is completed. 46CFR176.500 (b) (1)
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2023
Resolved 14 December 2023
Resolution: Annual inspection completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 December 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. VSL must undergo an annual inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2022
Resolved 19 December 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 22 October 2022 Resolved
46 CFR 15.805(a)(4) There must be an individual holding an appropriate license as or a valid MMC with endorsement as master in command of every inspected small passenger vessel. Vessel was being operated by an individual without a valid MMC while carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 23 December 2022
Resolution: Vessel owner provided MMC
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 22 October 2022 Resolved
46 CFR 16.210 No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel was being operated by an individual not subject to marine employer’s pre-employment chemical testing for dangerous drugs.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 23 December 2022
Resolution: Vessel owner provided DAPI documentation
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 9 December 2021 Resolved
46CFR184.402(a), Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Install marine compass with working light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2021 Resolved
46CFR180.71 (c) - each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter. Replace reflective tape on child Life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 December 2021 Resolved
46CFR181.500 (a) each portable fire extinguisher on a vessel must be of an approved type. Replace Fire extinguisher mounting bracket with approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2019 Resolved
Provide required items for first aid kit as required by 46 CFR 160.041 and appropiate instructions for use of items.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 December 2019 Resolved
COI not posted on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 December 2019 Resolved
Stability Letter not posted on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 December 2019 Resolved
Condemned two Type I Child Life Jackets.
Action required: 10 - Deficiency Rectified
Resolved 18 December 2019
Resolution: Vessel owner replaced life jackets during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 December 2019 Resolved
Lanyard for life ring buoy wasted.
Action required: 10 - Deficiency Rectified
Resolved 18 December 2019
Resolution: Vessel owner replaced lanyard during inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 September 2015 Resolved
Vessels waterlight was found to have incorrect style 6v replacement battery. Install correct 6v replacement battery
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 15 September 2015
Resolution: Vessel's waterlight batteries have been replaced with correct type
Lifesaving › Lifebuoys › Approval
Issued 2 September 2015 Resolved
Vessel found to have non CG approved Lifebuoy on board. Install CG Approved Lifebouy
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 15 September 2015
Resolution: CG Approved lifebouy installed on vessels
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 September 2015 Resolved
Vessel found to not have the required Lifejacket donning placard. Post Life Jacket donning placard.
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 15 September 2015
Resolution: Life Jacket donning placard posted on board the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 July 2007 Resolved
Provide a Coast Guard approved or equivalent first aid kit.
Condition: Improper/Lack of Maintenance
Due 19 July 2007
Resolved 20 July 2007
Resolution: New 1st Aid kit o/b; Meets CG standard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2007 Resolved
Make repairs to connectors to the electric wires servicing the accessories (nav lights) with pressure type connectors on each connection.
Condition: Improper Installation
Due 19 July 2007
Resolved 17 July 2007
Resolution: Connections repaired.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 July 2007 Resolved
Provide a support or brace to prevent movement of the portable fuel tank.
Condition: Improper Installation
Due 19 July 2007
Resolved 20 July 2007
Resolution: blocks installed to prevent fuel tank movement.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 July 2007 Resolved
Make repairs to the safety rails, port and starboard.
Condition: Improper/Lack of Maintenance
Due 19 July 2007
Resolved 17 July 2007
Resolution: Verified repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2005 Resolved
Replace accessories electrical wiring with 14AWG or larger of stranded copper (46CFR183.340)
Condition: Improper Installation
Due 11 August 2005
Resolved 10 August 2005
Resolution: Received invoice and statement from owner attesting to replacing of wire.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 July 2005 Resolved
Service one B-II portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Due 12 July 2005
Resolved 12 July 2005
Resolution: Serviced.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 11 May 2005 Resolved
Ensure that required crewmember is enrolled in a drug testing consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2005
Resolution: New crewmembers and new certificate provided.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 9 February 2005 Resolved
Provide a fuse in series as close to the battery as possible, to protect the accesories (ie nav lights, radio, and appliances).
Condition: Improper Installation
Due 10 February 2005
Resolved 11 February 2005
Resolution: Fuse provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 February 2005 Resolved
Secure battery tray to deck.
Condition: Improper Installation
Due 10 February 2005
Resolved 11 February 2005
Resolution: Secured.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 9 February 2005 Resolved
Replace electrical wires with stranded copper suitable for system to be used.
Condition: Improper Installation
Due 10 February 2005
Resolved 11 February 2005
Resolution: Wires replaced.
Electrical › Electric Supply System (service) › Cable
Issued 9 February 2005 Resolved
Make all electrical connections with connectors that have enclosure.
Condition: Improper Installation
Due 10 February 2005
Resolved 11 February 2005
Resolution: Connectors replaced.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 9 February 2005 Resolved
Provide hose clamp to fuel hose connection to gasoline portable tank.
Condition: Improper Installation
Due 10 February 2005
Resolved 11 February 2005
Resolution: Provided.
Engineering › Gasoline Engine (propulsion) › Hose, Cooling System (4 cycle)
Issued 9 February 2005 Resolved
Provide hose clamps to fuel hose primer pump (2 each).
Condition: Improper Installation
Due 9 February 2005
Resolved 11 February 2005
Resolution: Provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 February 2005 Resolved
Re-isntall B-II portable fire extinguisher.
Condition: Improper Installation
Due 9 February 2005
Resolved 11 February 2005
Resolution: Re-install.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 9 February 2005 Resolved
label vessel name on all lifejackets.
Condition: Improper/Lack of Maintenance
Due 10 February 2005
Resolved 11 February 2005
Resolution: Done.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 July 2004 Resolved
Stencil vessel name on lifebuoy.
Condition: Improper/Lack of Maintenance
Due 23 July 2004
Resolved 23 July 2004
Resolution: Done.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 16 July 2004 Resolved
Stencil vessel name on all lifejackets.
Condition: Improper/Lack of Maintenance
Due 23 July 2004
Resolved 23 July 2004
Resolution: Done.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 July 2004 Resolved
Stencil storage location for lifejackets.
Condition: Improper/Lack of Maintenance
Due 23 July 2004
Resolved 23 July 2004
Resolution: Done.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 July 2004 Resolved
Separate adult from child lifejackets.
Condition: Improper Installation
Due 23 July 2004
Resolved 23 July 2004
Resolution: Done.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 July 2004 Resolved
Properly secure cover to main battery tray. Ensure cables are not crimped.
Condition: Improper Installation
Due 23 July 2004
Resolved 23 July 2004
Resolution: Tray secured.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 July 2004 Resolved
Provide a Coast Guard or equivalent first aid kit.
Condition: Improper/Lack of Maintenance
Due 23 July 2004
Resolved 23 July 2004
Resolution: Provided.
Engineering › Gasoline Engine (propulsion)
Issued 25 November 2003 Resolved
Secure gasoline tank to deck. LEGACY COMPONENT DESC: Gasoline Tank
Condition: Improper Installation
Due 28 November 2003
Resolved 28 November 2003
Resolution: Witnessed correction.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 November 2003 Resolved
Secure battery to deck.
Condition: Improper Installation
Due 28 November 2003
Resolved 28 November 2003
Resolution: Corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 November 2003 Resolved
Provide a corrosion resistant tray to battery.
Condition: Improper Installation
Due 28 November 2003
Resolved 28 November 2003
Resolution: Provided.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 11 July 2002 Resolved
Provide evidence that all crewmembers are enrolled in an annual drug and alcohol program consortium.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2002
Resolution: Evidence from the consortium was provided via fax.
Construction/Loadline › Hull
Issued 11 July 2002 Resolved
Repair 2nd rail support to starboard side of rail forward.
Condition: Damaged By Earlier Event
Due 18 July 2002
Resolved 26 August 2002
Resolution: Rail repaired.
Lifesaving › Lifebuoys
Issued 11 July 2002 Resolved
Provide corrosion resistant clip to waterlight. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper Installation
Due 18 July 2002
Resolved 26 August 2002
Resolution: Clip provided and properly installed.
Electrical › Electric Generation Source (service)
Issued 11 July 2002 Resolved
Provide overload protection to battery (a fuse in series) as close as possible to the battery as per 46CFR183.350(g) and 380(g). LEGACY COMPONENT DESC: Overcurrent Device
Condition: Improper Installation
Due 18 July 2002
Resolved 26 August 2002
Resolution: Fuse provided to protect electrical wiring.
Construction/Loadline
Issued 18 September 2001 Resolved
Prove proper operation of/ or replace 5 gallon hand pump.
Condition: Unknown
Due 19 September 2001
Resolved 2 November 2001
Accommodation/Occupational Safety
Issued 16 December 1999 Resolved
Secure loose port side liferail
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Engineering
Issued 16 December 1999 Resolved
Replace missing nut IWO outboard engine mount
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Construction/Loadline
Issued 16 December 1999 Resolved
Repair hull underneath rub railing, port and starboard sides.
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Construction/Loadline
Issued 16 December 1999 Resolved
Re-attach forward center cleat
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Navigation
Issued 16 December 1999 Resolved
Replace and secure corroded mount IWO stern light
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Construction/Loadline
Issued 16 December 1999 Resolved
Re-attach aft port side cleat
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Navigation
Issued 16 December 1999 Resolved
Replace corroded steering wheel base / mount
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Documentation
Issued 5 November 1999 Resolved
PROVIDE EVIDENCE OF SATISFACTORY DRUG TESTING PROGRAM
Condition: Unknown
Due 5 December 1999
Resolved 7 December 1999
Lifesaving
Issued 26 August 1999 Resolved
PROVIDE A WATERPROOF BOX FOR STORAGE OF FLARES.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Unknown
Issued 26 August 1999 Resolved
PROVIDE EVIDENCE OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Engineering
Issued 26 August 1999 Resolved
COMPLETE REPAIR OF LOWER UNIT.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Unknown
Issued 26 August 1999 Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Lifesaving
Issued 26 August 1999 Resolved
PROVIDE 60 FEET OF DARK COLOR LINE TO RING BUOY.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Lifesaving
Issued 26 August 1999 Resolved
PROVIDE A TOTAL OF 19 ADULT AND 2 CHILD LIFEJACKETS. PRIOR TO VESSEL OPERATION.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Lifesaving
Issued 26 August 1999 Resolved
PROVIDE THREE HAND HELD RED FLARES.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Lifesaving
Issued 6 November 1998 Resolved
PROVIDE LIFEJACKET PLACARD.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Documentation
Issued 6 November 1998 Resolved
PROVIDE LOG TO DOCUMENT REQUIRED CREW TRAINING.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Lifesaving
Issued 6 November 1998 Resolved
PROVIDE THREE (3) HAND HELD RED FLARES.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Navigation
Issued 26 November 1997 Resolved
RENEW BOLT AND NUT FOR STEERING WHEEL.
Condition: Unknown
Due 30 December 1997
Resolved 12 January 1998
Construction/Loadline
Issued 26 November 1997 Resolved
REPAIR FRACTURE STARBOARD AFT CABLE PIPE.
Condition: Unknown
Due 30 December 1997
Resolved 12 January 1998
Construction/Loadline
Issued 26 November 1997 Resolved
RE-TIGHTEN LOOSE SCREWS FOR PILOT STATION SEAT.
Condition: Unknown
Due 26 November 1997
Resolved 26 November 1997
Accommodation/Occupational Safety
Issued 26 November 1997 Resolved
REPLACE LIFE RAILS PORT AND STARBOARD.
Condition: Unknown
Due 26 November 1997
Resolved 26 November 1997
Construction/Loadline
Issued 26 November 1997 Resolved
RENEW WOOD FOR SEATING BENCHES.
Condition: Unknown
Due 30 December 1997
Resolved 12 January 1998
Documentation
Issued 26 June 1997 Resolved
PROVIDE LOG BOOK TO RECORD REQUIRED FIRE FIGHTING AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Construction/Loadline
Issued 26 June 1997 Resolved
INSTALL ALUMINUM BACKING PLATE ON TRANSOM WITH WELDED GUSSET TO THE DECK AND THROUGH-BOLTED TO THE OUTBOARD.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Construction/Loadline
Issued 26 June 1997 Resolved
REPAIR FRACTURE IN TOP OF TRANSOM.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Fire Fighting
Issued 1 November 1995 Resolved
INSTALL PROPER BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Electrical
Issued 1 November 1995 Resolved
REMOVE ALL UNUSED WIRES FROM IN STEERING STATION
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Lifesaving
Issued 1 November 1995 Resolved
RENEW REFLECTIVE MATERIAL ON ALL LIFE JACKETS.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Documentation
Issued 20 September 1994 Resolved
PROVIDE PROOF OF PRE-EMPLOYMENT AND RANDOM DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 C.F.R. PART 16.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Navigation
Issued 21 September 1993 Resolved
Post emergency check-off list as per 46CFR185.25-1.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Lifesaving
Issued 21 September 1993 Resolved
Provide proper battery for water light.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Fire Fighting
Issued 21 September 1993 Resolved
Provide 2 B-II fire extinguishers to bring the total fire extinguishers on board to 2 B-II and 1 B-I prior to carrying passengers.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Documentation
Issued 21 September 1993 Resolved
Provide documentation that a drug testing program that complies with 46 CFR16 is in place.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Lifesaving
Issued 11 September 1991 Resolved
RENEW LIFERING GRABLINE AND STEWCIL VSL NAME ON IT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Unknown
Issued 11 September 1991 Resolved
CONDUCT UNDERWAY DRILLS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Fire Fighting
Issued 11 September 1991 Resolved
PERMANENTLY MOUNT FIRE EXTINGUISHER BRACHET TO VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Engineering
Issued 11 September 1991 Resolved
PERMANENTLY SECURE BATTERY BOX DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Navigation
Issued 11 September 1991 Resolved
PERMANENTLY MOUNT STERN LIGHT TO VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Lifesaving
Issued 11 September 1991 Resolved
STENCIL VESSEL NAME ON ALL PFD'S AND ATTACH RETROTAPE TO SAME. VESSEL IS LIMITED TO 15 TOTAL PERSONS UNTIL REQUIREMENT IS CLEARED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991

Ownership record