MYSTIC is a 1988 freight ship. The Coast Guard has recorded 20 inspections since 1988, most recently in August 2005, along with 12 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1988 to 2005. Most recent: inspection, 16 August 2005.

Built
1988
Last inspected
16 August 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8609929 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
318829
Flag
NETHERLANDS
—
Maury page id
psix-318829

Inspections, by type

…with no type recorded14
…past their stated due date1
Years with a record 10 calendar years (1988–2005)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3341 - Regulatory (Subpart C or D), Net Ton
6105 - Dead Weight, Ton
3898 - Convention (Subpart B), Gross Ton
5089 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

16 August 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2464649
15 August 2005 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2463842
10 August 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2460424
14 June 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2390088
10 May 2005 Deficiency Check · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2354452
4 May 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2348906
2 February 2005 ISPS II Exam · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2285002
12 June 2004 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2095842
22 April 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2049810
22 February 2000 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 275037
3 April 1999 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 427211
31 December 1998 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 424196
20 January 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 411890
17 June 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404701
2 March 1996 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 388517
16 August 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 522405
3 February 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 335165
14 May 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 469415
24 April 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 440931
30 September 1988 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 326172

Deficiency record · 12

Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 August 2005 No resolution recorded
Lloyd's surveyor imposed the following Conditions of Class on the vessel: 1) No. 2 center Fuel Oil double bottom tank to be internally inspected for possible fuel leaks into the three bilge wells and pipe connections between these bilge wells. (2) Meantime, this tank is not to be used to carry fuel oil and level of bilge well to be closely monitored by ships staff. 3) Clean aft bilge sounding
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2005 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 May 2005 Resolved
Oily water separator does not have means to determine that discharge from separator does not exceed 15 parts per million as required by MARPOL 73/78 ANnex I Reg 16 (4). Provide class report to coast guard attesting to fulfillment of requirement. Vessel is not to use oily water separator until addressed by class.
Action required: 705 - Other - as specified
Due 17 May 2005
Resolved 13 June 2005
Resolution: Class report provided attesting to requirements of MARPOL 73/78 Annex I Reg. 16 (4)
Electrical › Electric Generation Source (emergency) › Switch
Issued 10 May 2005 Resolved
Prove proper operation of emergency generator shut off. Currently RPMs of engine increase when generator is supposed to shut down, generator does not shut down. SOLAS CH II-1/44
Action required: 15 - Rectify deficiencies by next port
Resolved 10 May 2005
Resolution: Generator now shuts off, but trips overspeed alarm on start-up. Issuing separate deficiency for over speed alarm.
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 May 2005 Resolved
Replace clamps where deteriorated on cooling system of emergency generator. SOLAS 74 CH II-1/44
Action required: 15 - Rectify deficiencies by next port
Resolved 12 May 2005
Resolution: Clamps replaces
Operations/Management › Drills/Instruction › Fire
Issued 10 May 2005 Resolved
Perform satisfactory drills, crew fire drills need improvement. SOLAS CH III reg 19/3.4 Inadequate communication between Master and what was happening onscene.
Action required: 705 - Other - as specified
Resolved 13 June 2005
Resolution: Drills performed satisfactory in accordance with SOLAS Ch. III/Reg. 19.3.4
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 10 May 2005 Resolved
Emergency generator trips overspeed alarm on every start.
Action required: 705 - Other - as specified
Resolved 12 May 2005
Resolution: Generator runs properly with no alarms
Lifesaving
Issued 31 December 1998 Resolved
VESSELS LINE THROWING APPLIANCE WAS NOT OUTFITTED WITH FOUR PROJECTILES ANDFOUR LINES AS REQUIRED BY SOLAS 74 CHAPTER III, REGULATION 49. CORRECTION IS REQUIRED PRIOR TO 31JAN99.
Condition: Unknown
Due 3 April 1999
Resolved 3 April 1999
Engineering
Issued 31 December 1998 Resolved
VESSEL IS TO REPLACE THE EXISTING 100 PPM OIL WATER SEPERATOR WITH AN APPROVED 15 PPM OIL WATER SEPERATOR AND AMMEND THE IOPP CERTIFICATE TO REFLECT THE INSTALLED EQUIPMENT IAW MARPOL 73/78 ANNEX I, REGULATION 16 NLT31JAN99.
Condition: Unknown
Due 3 April 1999
Resolved 3 April 1999
Fire Fighting
Issued 31 December 1998 Resolved
VESSEL IS TO PROVIDE CLASS ACCEPTANCE OF THE FIRE EXTINGUISHING ARRANGEMENTIN THE FOC'SLE PAINT LOCKER NLT 31JAN99.
Condition: Unknown
Due 3 April 1999
Resolved 3 April 1999
Navigation
Issued 17 June 1997 Resolved
A violation of SOLAS 74 Ammended in that the required nonslip surface around steering gear machinery was not in place
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Navigation
Issued 2 March 1996 Resolved
Current tidal current tables not available.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Navigation
Issued 2 March 1996 Resolved
Current tidal current tables not available
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998

Ownership record