NQ BELLIS is a 2000 tank ship. The Coast Guard has recorded 12 inspections since 2017, most recently in January 2025, along with 5 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 2017 to 2025. Most recent: inspection, 29 January 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it15200 - Dead Weight, Metric Ton 20974 - Displacement, Metric Ton 11287 - Convention (Subpart B), Gross Ton 4633 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Deficiency Code- 12106
Deficiency Category - Dangerous Goods
PRESSURE SENSORS SHALL PROVIDE AN ALARM FACILITY WHICH IS ACTIVATED BY DETECTION OF OVER-PRESSURE OR UNDER-PRESSURE CONDITIONS WITHIN A TANK.
PSCO OBSERVED THE PRESSURE READING FOR CARGO TANK 4P WAS WITHIN NORMAL RANGE OF 200-550 MBAR (CURRENTLY 362 MBAR) BUT HIGH ALARM WAS ACTIVE AND COULD NOT BE RESET. TANK 5S LOW PRESSURE ALARM DID NOT ACTIVATE DURING TEST. TANK 9S READ -(NEG)564 MBAR, WHICH WAS NOT ACCURATE BASED ON SET POINT OF P/V VALVE NOT BEING PHYSICALLY REACHED.
Deficiency Cite/Regulation-
74SOLAS(14)VII/10.1
IBC Code 8.3.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Resolution: Vessel submitted Class Report attesting to satisfactory repairs. Crew recalibrated pressure sensor for 4P and 5S. Tested sat. Crew replaced IG sensor for 9S and tested sat.
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 April 2017Resolved
1499(Other)- When the emergency source of electrical power is a generator, it shall be started automatically upon failure of the main source of electrical power supply. The temporarily installed generator is not automatically started upon failure of main source of electrical power. Manual operation is required. 74SOLAS(04)II-1/43.1.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2017
Resolved 7 April 2017
Resolution: Received class report attesting to the proper operation of the emergency generator automatic start.
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 April 2017Resolved
1499 (Other)- The electrical power available shall be sufficient to supply all these services that are essential for safety in an emergency period of 18 hours. The fuel provided will not supply the required 18 hours of power needed for emergency services, only for approximately 15 hours. 74SOLAS(04)II-1/43.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2017
Resolved 7 April 2017
Resolution: Received class report clarifying fuel consumption for emergency generator.
0999 (Other, Safety in General)- Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. The fixed lights above the starboard manifold and the forward light above the port manifold are compromised in their cable installations and not prevent cargo vapors from entering the casing. 74SOLAS(14)VII/10.1 IBC Code 10.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2017
Resolved 7 April 2017
Resolution: Received class report attesting to repairs of lights near manifolds.
Deck/Cargo › Cargo Stowage › General
Issued 6 April 2017Resolved
1899 (Other, Tankers)- Cargo piping systems must be arranged so that operations necessary to provide seperate systems can be accomplished in a cargo handling space or on the weather deck. Appoximtatly 50% of the valve indicators on both the port and starboard manifold were wasted and the crew were unable to determine postion of over 20 manifold valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 April 2017
Resolution: Deficienty rectified on spot.