SEACOR CHAMPION is a 2001 offshore supply vessel. The Coast Guard has recorded 7 inspections since 2016, most recently in May 2019, along with 2 deficiencies and 3 casualty investigations between 2005 and 2014.

Records from 2005 to 2019. Most recent: inspection, 24 May 2019.

Built
2001
Last inspected
24 May 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2019
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8765034
WDG3598
Flag
NIGERIA
Maury page id
psix-31896

Documentation record

Tonnage as PSIX records it284 - Regulatory (Subpart C or D), Gross Ton
1312 - Convention (Subpart B), Gross Ton
193 - Regulatory (Subpart C or D), Net Ton
393 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

24 May 2019 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6698255
6 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6367085
6 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6367150
10 October 2017 Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6284740
2 March 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6097850
7 February 2017 MTSA Verification · Administrative Inspection · COI Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6084284
11 March 2016 Annual Inspection · MTSA Verification · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5826314

Deficiency record · 2

Engineering › Compressed Air System (start air) › Valve
Issued 11 March 2016 Resolved
All three PR vlvs on air receivers are set at 195PSI and did not relieve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 15 March 2016
Resolution: Three PR vlv rated at 175psi added to system and all tested SAT.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 11 March 2016 Resolved
PSI gauge not approved for system pressures as per regulations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 15 March 2016
Resolution: Vsl added psi gauge of 250 psi.

Casualty record · 3

18 January 2005Routine · role: Involved in a Marine Casualty · activity 2280393
14 July 2006Routine · role: Involved in a Marine Casualty · activity 2718093
10 January 2014Routine · role: Involved in a Marine Casualty · activity 4784315
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SUPERIOR CHAMPION (2005–2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.