KAI LANI is a 1988 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1988, most recently in July 2026, along with 262 deficiencies, 3 operational controls and 1 casualty investigation in 2021.

Records from 1988 to 2026. Most recent: inspection, 24 July 2026.

Built
1988
Last inspected
24 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB6002
319120
Flag
UNITED STATES
366916220
Maury page id
psix-319120

Inspections, by type

…with no type recorded6
Years with a record 35 calendar years (1988–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 21.5 ft × 7.0 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLIAM R. BREEZY · NAALEHU, HI, UNITED STATES · built 1988
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portHEEIA KEA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
16 - Simplified, Net Ton
16000 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB6002MMSI 366916220 · active · compulsorily equipped · granted 14 December 2023, expires 16 December 2033 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 75

24 July 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8445773
19 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8302336
14 April 2025 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8108479
19 March 2025 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8079976
29 April 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7886072
16 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7680635
13 April 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7619610
9 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7448705
6 December 2021 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7363543
6 December 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7371347
21 May 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7202885
24 March 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7162367
16 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6978833
24 March 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6926419
1 July 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6732821
24 June 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6720632
4 April 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6656038
23 April 2018 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6397618
15 June 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6176277
11 April 2017 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6122547
30 March 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5842115
30 December 2011 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4216294
10 March 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3693529
8 March 2010 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3690697
14 April 2009 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3452081
18 February 2009 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3419706
17 March 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3155452
13 March 2007 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2864895
14 February 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2584945
24 February 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2298187
8 February 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2288976
3 December 2004 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2252769
9 December 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1961315
9 October 2002 Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1686050
25 March 2002 Hull Examination · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1597482
25 March 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1597503
23 February 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1489175
27 September 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1408847
18 September 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414012
15 May 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376602
20 October 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1054736
18 September 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382032
24 November 1999 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 811530
20 October 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1384275
5 October 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372754
16 October 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1455642
19 November 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 786176
15 October 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 774871
19 September 1997 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381006
8 August 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368345
16 December 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1091529
10 October 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1409586
27 September 1996 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355966
1 February 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396446
29 January 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1467913
16 November 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1458250
20 October 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385568
21 September 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374396
25 August 1995 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363354
25 August 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371150
22 September 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354946
17 November 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385167
20 August 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1459036
27 November 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 93749
14 September 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1262443
1 November 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 934365
17 October 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 942735
27 September 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937428
26 October 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1237541
26 June 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 901798
7 May 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 919396
6 April 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1238236
11 January 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1227906
10 October 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034284
19 October 1988 Hull Examination · Plan Review "T" Boat · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1036128

Deficiency record · 262

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2026 Resolved
A vessel must carry one floating waterlight...Each light must be approved in accordance with 161.010 in subchapter Q of this chapter. Floating waterlight is not approved type under 161.010. Replace waterlight with an approved type under 161.010 within 7 days to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2026
Resolved 22 May 2026
Resolution: Provided documentation of approved type floating waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2026 Resolved
A vessel more than 26 feet in length but no more than 65 feet must carry one life buoy of not less than 24 inches in diameter. Ring life buoy found cracked and deteriorated. Replace life buoy within 7 days to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2026
Resolved 22 May 2026
Resolution: Provided documentation of new ring life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2026 Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Flame impingement bowl under starboard engine fuel filter is missing. Replace bowl to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 22 June 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2026 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without approval of the cognizant [name withheld] rot found along the perimeter of benches in main seating area and in port side aft corner of the upper deck beam. Grind areas back to good material and determine extent of rot. Upon determining extent of rot, provide repair proposal for review and approval of attending marine inspector. Once approved, make repairs to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 May 2026
Resolution: Provided repair proposal and made effective repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2026 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The battery fuses are MRBF terminal fuse block fuses. Replace with UL approved cartridge fuses of the same voltage and amperage to the satisfaction of th attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 24 July 2026
Resolution: Replaced fuses with UL approved cartridge fuses.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2025 Resolved
An adult life jacket must be provided for each person carried on-board a vessel. Attending marine inspector observed then non-serviceable life jackets. Replace with serviceable type 1 life jackets. Total persons allowed is reduced until deficiency is cleared. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 15 April 2025
Resolution: Received documentation (photos) attesting to the resolution of the life preserver deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2025 Resolved
Provisions shall be made by means of plugs, covers, etc to prevent the admission of air into the space protected. Attending marine inspector observed an unsealed opening in the stbd engine space's fwd bulkhead. Restore air-tight integrity of the bulkhead to the satisfaction of the attending marine inspector. 46 CFR 181.20-8
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2025
Resolution: Received documentation (photos) attesting to the resolution of the masthead light deficiency and the airgap in the engine room deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 April 2025 Resolved
A power driven vessel underway shall exhibit a masthead light forward. Attending marine inspector observed the forward masthead light fail to energize. Restore function to the satisfaction of the attending marine inspector. 33 CFR 83.23(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2025
Resolution: Received documentation (photos) attesting to the resolution of the masthead light deficiency and the airgap in the engine room deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 14 April 2025 Resolved
On a vessel which the number of passengers permitted on upper decks is limited by stability criteria... the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) high. Attending marine inspector identified the upper deck unlabeled with passenger count. Corrected on the spot by vessel master. 46 CFR 185.602(g)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2025
Resolution: Corrected by crew on site.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Attending marine inspector identified the forward most starboard bilge pump inoperable. Corrected on site by deckhand by pump replacement. 46 CFR 182.520(a)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2025
Resolution: Corrected on scene by crewmember prior to inspector departure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2025 Resolved
By March 15 of the year following the collection of the data in paragraph (a) of this section, marine employers must submit the data on the form titled U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form... Vessel unable to provide proof of MIS submission. Submit and provide to the attending marine inspector proof of MIS documentation. 46 CFR 16.500(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2025
Resolved 16 April 2025
Resolution: Documents received via email showing completion and submission of the MIS form.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 April 2025 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Attending marine inspector identified a section of rot in the port, aft-most, compartment on the inboard side immediately bellow the hatch. Repair in accordance with the verbally approved repair proposal to the satisfaction of the attending marine inspector. 46 CFR 177.300(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2025
Resolved 24 April 2025
Resolution: Bulkhead in the port aft-most compartment repaired satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2024 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for each vessel and its operations and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Stbd salt water hoses for the engine are collapsing just past the sea valve and chaffed just past the strainer. Replace two sections of hoses. 46 CFR 182.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2024
Resolution: Replaced two salt water hoses.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 April 2024 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Air supply plugs to close off the engine spaces have lines that are too short for the forward plugs on the port and stbd side. Replace with a longer line so that ventilation plugs can be put into place with ease. 46 CFR181.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2024
Resolution: Extended lines for ventilation plugs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2024 Resolved
Check the conditions of the superstructure, flying bridge, masts, stacks, fishing platforms and similar arrangements constructed on the hull. In sailing vessels inspect all spars, running rigging, blocks, fittings, and sails. Cotter pins for all turnbuckles that attached the stays and shrouds to the chain plates were meat hooking. Ensure all cotter pins are turned inside to avoid injury or getting snagged. 46 CFR 176.25-5(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2024
Resolution: Cotter pins were turned in and corrected.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 May 2023 Resolved
Lamp, paint, and oil lockers and similar compartments shall be constructed of metal or lined with. MI discovered paint being stored in the port-side, forward compartment which is not constructed nor lined with steel. Paint stores to be removed prior to the carriage of passengers. 46 CFR 177.10-5(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2023
Resolution: Paints and cleaners removed from the port-side, forward compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy grab line is fraying. Replace grab line. 46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 21 June 2022
Resolution: Installed new ring buoy and grab line.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 May 2022 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Mesh on port and starboard flame screens were not completely attached to vent pipes. Reattach mesh to eradicate gaps. 46 CFR 182.20-35(d)"Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Flame screens attached.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 May 2022 Resolved
Wire connectors utilized in conjunction with screw type terminal blocks must be of the captive type such as the ring or the flanged spade type. Non-captive connectors on bus bar under console. Replace with approved type. 46 CFR 183.340(k)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 14 May 2022
Resolution: Replaced with captive type.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 May 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. First-aid kit is incomplete. Provide USCG-approved kit or a kit that complies with the list in 46 CFR 160.041. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 17 June 2022
Resolution: Sent picture of new first-aid kit.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 May 2022 Resolved
The owner or managing operator of a qualified servicing facility shall conduct inspections and tests as applicable for fixed gas fire extinguishing systems and must provide evidence of the required servicing to the marine inspector. Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel's fire extinguishing systems serviced but reports were missing. E-mail report detailing satisfactory evidence of required inspections, maintenance procedures, and tests by a qualified servicing facility. 46 CFR 176.810(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 12 May 2022
Resolution: Received servicing report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2022 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Company has had DAPI Audit conducted within the past year. Provide satisfactory proof that all crew onboard have passed pre-employment testing by providing company's crew list and testing results. 46 CFR 16.210(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 31 October 2022
Resolution: Annual audit was completed on February 2022.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2022 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] worn. Replace buckets. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Received photo of new buckets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2022 Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel does not have in place a preventative maintenance plan in accordance with USCG NVIC 02-16. Operator shall schedule a 3rd party rigging survey to include rigging inspection aloft, and provide the survey report prior to operating under sail to [email withheld]. 46 CFR 176.802(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2022
Resolved 17 June 2022
Resolution: Satisfactory rigging survey conducted by [name withheld].
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 May 2022 Resolved
Each vessel must have permanent draft marks at each end of the vessel or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. To be completed at next drydock but no later than 31 March 2023. 46 CFR 185.602(c)
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 9 April 2025
Resolution: Required draft marks were installed, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 December 2021 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel broke free of its mooring and was found washed ashore on 07DEC2021 on the Sand Bar located in Kaneohe Bay. Vessel is prohibited from carrying passengers until the hull is made available for inspection by USCG Marine Inspectors to determine if the hull or its appendages were damaged while drifting or during the subsequent grounding. 46CFR176.600(d)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2022
Resolution: Repairs were made IAW agreed upon proposal.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 May 2021 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. Vessel does not have a valid Safety Radiotelephony Certificate. Vessel shall not operate more than 1,000 feet from shore without a valid Safety Radiotelephony Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 May 2021
Resolution: Received FCC Safety Certificate.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2021 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Port running light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules. Vessel is restricted to day light only operations until all navigation lights are functional.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2021
Resolution: Operator provided picture of port light operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Raw water intake on the starboard engine is missing the hose clamp at the joint of the flexible hose and the metallic shutoff valve. Install hose clamp.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 10 June 2021
Resolution: Operator provided photograph of replaced hose clamp.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 May 2021 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Third step from bottom on bow embarkation ladder has a fractured weld on the starboard side. Submit a repair proposal for pitting to the satisfaction of Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2021
Resolved 11 June 2021
Resolution: Weld repaired to the satisfaction of the Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 May 2021 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Vessels 12VDC switch panels do not have overcurrent protection. Each circuit shall be protected against overcurrent’s.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2021
Resolved 10 June 2021
Resolution: Operator provided photographs of properly installed overcurrent protection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2020 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520 (a). The following fixed hand bilge pumps are not operational, port storage compartment, port forepeak, port compartment forward of the lazarette, stbd forepeak and stbd fuel tank compartment. Additionally, there was no portable hand bilge pump onboard the vessel during the inspection. Demonstrate the proper operation of the five non-operational fixed hand bilge pumps and missing portable hand bilge pump to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2020
Resolved 31 July 2020
Resolution: All fixed hand bilge pumps and portable hand bilge pump are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020 Resolved
A vessel of more the 26 Feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. The vessel's ring buoy is no longer serviceable. Provide a USCG approved 24 inch life buoy to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2020
Resolved 30 July 2020
Resolution: Serviceable 24" lifebuoy outfitted on the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The vessel's stbd running light is not operational. Demonstrate the proper operation of the vessel's stbd running light to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2020
Resolved 30 July 2020
Resolution: Vessel's starboard running light is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Each lifejacket must be approved in accordance with 160.002, 160.005 0r 160.055 in subchapter Q of this chapter. One adult life jacket's retro reflective tape is no longer serviceable. Provide a serviceable adult life jacket to the satisfaction of the attending USCG Marine Inspector. The vessel's total persons allowed has been reduced from 51 to 50 until this deficiency has been cleared by a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 July 2020
Resolved 30 July 2020
Resolution: Serviceable retroflective tape installed on the adult lifejacket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2020 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are employed. The following sail rigging components were deemed to need replacing or verification that they are suitable for continued service by conducting non-destructive testing (NDT), the upper and lower mast tang sets and the headstay delta plate. Additionally, the port and stbd aft lower shrouds are missing cotter pins. Replace or conduct NDT of the upper and lower mast tangs and headstay delta plate and replace the port and stbd aft lower shroud cotter pins to the satisfaction of the attending USCG Marine Inspector. The vessel is not authorized to operate under sail until this deficiency has been cleared by a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 16 July 2020
Resolved 30 July 2020
Resolution: The upper and lower mast tangs and headstay delta plate the port and stbd aft lower shroud cotter pins were replaced. Sail rigging survey report attached to this deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2019 Resolved
Sail rigging and components are to be maintained in accordance with good marine practice. Observed boom held in place by frayed topping lift and the tang connecting the backstay to the boom is cracked and corroded. Provide repair plan to ensure adequate rigging configuration per vessel's Preventative Maintenance Plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 31 July 2019
Resolution: Vessel submitted photograph showing repair to the shackle and tang. New shackle and tang attached to the aft end of the boom for the topping lift connection point. Repair satisfactory. Photo uploaded into MISLE. //s// [name withheld], LT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 June 2019 Resolved
A portable hand bilge pump must be capable of pumping water. Starboard aft void portable hand bilge pump was not operable. Provide operable hand pump capable of pumping water from the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 1 July 2019
Resolution: Verified proper installation and operation of stbd hand bilge pump. Photo attached in vsl documents. //s// [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2019 Resolved
Each lifejacket must be marked in legible block capital letters with the vessel's name. 18 life preservers were not labeled with vessel's name. Mark in clearly legible block letters with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 1 July 2019
Resolution: Verified proper marking of all newly purchased lifejackets on board vsl. Photograph included in vsl documents. //s// [name withheld], LT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 June 2019 Resolved
Deck hatches in the main passenger deck do not prevent the ingress of water. Hatches observed with penetrations. Properly renew hatch covers to prevent ingress of water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 1 July 2019
Resolution: Verified proper repair of all weathertight deck hatches. Photographs included in vsl documents. //s// [name withheld], LT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2019 Resolved
Vessel required to have one 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebouy found cracked and faded. Provide serviceable ring lifebuoy onboard vessel and properly arranged.
Action required: 10 - Deficiency Rectified
Due 24 June 2019
Resolved 24 June 2019
Resolution: Vessel operator attached serviceable waterlight and lifeline to appropriate ring lifebuoy in good condition. Discrepancy cleared. //s// [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2019 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring underneath operating station has several exposed and dead end wires. Properly remove or cover to prevent potential shock or fire hazards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
Resolution: Verified proper electrical installation. Vsl removed old FM radio power and grounding wires, and reattached the power and grounding wires to the plug outlet where they had been pulled free. //s// [name withheld], LT
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 23 April 2018 Resolved
Code 99101: Operator does not have in place a preventative maintenance plan to adequately assess the safe condition of their sail rigging system in accordance with USCG NVIC 02-16. Provide 3rd party rigging survey to assess the condition of the sail rigging system and establish a beginning date for a PMP to be implemented. 46 CFR 176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 May 2018
Resolution: Operator hired 3rd party surveyor to assess the condition of the rigging system. 3rd party surveyor supplied a check list to the operator to complete a weekly/monthly PMP. Inspector verified weekly and monthly PMP with operator on the vessel.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 23 April 2018 Resolved
Code 08199: A vessel of 26 ft or more in length must have a visual and audible bilge high water alarm in spaces with through-hull fittings and a machinery space. High water alarm in starboard engine room found inoperable. 46 CFR 182.530(a)
Action required: 10 - Deficiency Rectified
Due 23 May 2018
Resolved 23 April 2018
Resolution: Operator replaced the high water alarm and wiring in the port engine room. High water alarm tested and found to be operational.
Electrical › Electrical Distribution System (service) › Conductor
Issued 23 April 2018 Resolved
Code 02108: Electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Observed corroded wires at terminal connections on the main deck behind the port and starboard fuse panels. Observed corroded terminal connections between the house batteries on the main deck. 46 CFR 183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 May 2018
Resolution: Electrical connections found cleaned and preventative maintenance carried out over the last 30 days. All terminal connections appeared satisfactory for service.
Sail Rigging › Chainplates › Fasteners
Issued 23 April 2018 Resolved
Code 02199: The owner/operator shall have the condition of the hull, spars, standing rigging, running rigging, blocks, and fittings ready for inspection. Observed starboard back stay chain plate fastener (upper fastener) backed out away from the hull. Removal of the fastener revealed brown rot in the wood hull core. Provide repair proposal and refasten chain plate with repaired core. 46 CFR 176.802(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 May 2018
Resolution: Operator submitted repair plan. Repair plan approved by [name withheld] removed previous fastener, grinded damaged area to good wood, repaired the damaged hull, and replaced with a new fastener.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 23 April 2018 Resolved
Code 02108: Conductors must have overcurrent protection in accordance with their current carrying capacities. Operator placed a new electrical installation onboard, DC to AC inverter. Inverter conductor between battery and inverter is missing a disconnect means on the supply side of a fuse and is also missing a UL listed class cc, g, h, j, k, RK1, RK5, or T fuse. 46 CFR 183.380(a) and (k)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 May 2018
Resolution: Operator purchased a class cc UL listed fuse and installed in between the battery disconnect and inverter to protect the conductor from the battery to inverter.
Engineering › Fuel Oil Service System › Filter
Issued 15 June 2017 Resolved
Provide drip pans for fuel filters on both engines. 46 CFR 182.455(b)(6)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 21 June 2017
Engineering › Bilge Water Management System › Interface Detector
Issued 15 June 2017 Resolved
Replace forward bilge high water alarm on starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 21 June 2017
Engineering › Bilge Water Management System › Interface Detector
Issued 15 June 2017 Resolved
Repair bilge high water level alarm on port side rudder area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 21 June 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 March 2016 Resolved
Provide a valid certificate of documentation prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 March 2016 Resolved
Post COI under transparent material
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 12 April 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 March 2016 Resolved
Provide valid FCC safety certificate
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 12 April 2016
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 March 2016 Resolved
Provide 2 adult life jackets. Passenger count will be restricted to 47 persons.
Action required: 705 - Other - as specified
Resolved 1 April 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 March 2016 Resolved
Replace retroreflective tape on both life rings
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 1 April 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 30 March 2016 Resolved
Replace retroreflective tape on identified 17 adult life jacets and 7 child life jackets
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 1 April 2016
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 March 2016 Resolved
Replace clip on 1 identified child life jacket
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 1 April 2016
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 30 March 2016 Resolved
Complete annual sail rigging survey for 2016 per proposal dated March 2015
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 13 May 2016
Resolution: Received survey report.
Documentation › Logs/Records › Drug Test Records
Issued 30 March 2016 Resolved
Provide a copy of the company's drug policy onboard.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 12 April 2016
Documentation › Logs/Records › Drug Test Records
Issued 30 March 2016 Resolved
Post drug assistance hotline numbers onboard boat
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 12 April 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 March 2016 Resolved
Provide replacement First Aid kit for expired medication
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 1 April 2016
Engineering › Bilge Water Management System › Pump
Issued 8 March 2010 Resolved
Prove proper operation of port bilge pumps in forward compartment and fuel tank space. 46CFR182.510
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2010
Construction/Loadline › Hull › Side Shell
Issued 8 March 2010 Resolved
Submit repair proposal for puncture hole in port lazarette.
Due 8 April 2010
Resolved 12 April 2010
Resolution: Repaired puncture hole by inserting plug with a back plate and epoxying over.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 March 2010 Resolved
Provide proof of master's aux sail endorsement IAW COI.
Due 8 April 2010
Resolved 12 April 2010
Documentation › Certificates/Documents › FCC SSL
Issued 8 March 2010 Resolved
Provide FCC Safety Certificate IAW 47CFR80.401
Due 8 April 2010
Resolved 12 April 2010
Lifesaving › Hand Flares › Expired
Issued 8 March 2010 Resolved
Provide 2 orange smoke flares IAW 46CFr185.612.
Action required: 705 - Other - as specified
Resolved 10 March 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 March 2010 Resolved
Renew electrical splice under portside of control station IAW 46CFR183.340(g) or 183.340(i)
Due 8 April 2010
Resolved 12 April 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 March 2010 Resolved
Renew 2 hose clamps on starboard engine raw water intake in way of shut off valve and filter 46CFR182.410(d)
Due 8 April 2010
Resolved 12 April 2010
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 8 March 2010 Resolved
Renew hose clamp on starboard sewage overboard.
Due 8 April 2010
Resolved 12 April 2010
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 8 March 2010 Resolved
Replace starboard engine air filter, make as original.
Due 8 April 2010
Resolved 12 April 2010
Stability › Weathertight Integrity › General
Issued 8 March 2010 Resolved
Renew both lazarette hatches.
Due 8 April 2010
Resolved 12 April 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 March 2010 Resolved
Store 7 lifejackets in location that doesn't block bilge hand pump and label. 46CFR180.78
Due 8 April 2010
Resolved 29 September 2017
Resolution: Changed storage location and labeled.9/29/2017: It appears this was intended to be marked resolved, COI has been conducted since this def was issued.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 March 2010 Resolved
Vessel operated with passengers for hire without a valid COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2010
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 April 2009 Resolved
Found (3) hatches missing retaining lines, provide means of retaining all hatches on board.
Due 14 April 2009
Resolved 23 April 2009
Resolution: Verified replacement of all retaining lines.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 14 April 2009 Resolved
Found paints, thinners, acetone, and gasoline in port hold, remove flammables from vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2009
Resolved 15 April 2009
Resolution: Verified master removed all flammables off of the boat. They are now stored in a shed on shore.
Deck/Cargo › Holds/Tanks › Hatch
Issued 14 April 2009 Resolved
Found wood rot in starboard aft stowage hatch shelf and port aft hatch cover, which is split along lamination. Make proper repair to hatches.
Due 14 May 2009
Resolved 23 April 2009
Resolution: Verified replacement of starboard hatch shelf. Master also reglued and resealed port hatch cover.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2009 Resolved
First-aid kit had expired Ammonia inhalants and missing pain reliever, replace expired medication.
Due 14 May 2009
Resolved 23 April 2009
Resolution: Confirmed master replaced expired and missing items in First Aid Kit.
Documentation › Certificates/Documents › FCC SSL
Issued 14 April 2009 Resolved
Station License was not on board, provide FCC Station License.
Due 14 May 2009
Resolved 27 April 2009
Resolution: Received copy of current FCC Station License.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 April 2009 Resolved
Float light for ring buoy was inoperative, provide properly operating float light, in meantime day time operations only.
Due 14 May 2009
Resolved 23 April 2009
Resolution: Witnessed proper operation of the ring buoy float light.
Engineering › Bilge Water Management System › Not Operational
Issued 14 April 2009 Resolved
Bilge alarms inoperative, make proper repair, in meantime operator is required to make (1) round every 30 minutes while operating.
Due 20 April 2009
Resolved 23 April 2009
Resolution: Witnessed proper operation of bilge alarms following replacement of the alarm panel..
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 April 2009 Resolved
Found the deckhands were covered as ranchhands for random screening and were only subjected to 25% coverage per year and screening uses the State of Hawaii DOT form vice Federal marine employee form.
Due 15 May 2009
Resolved 24 April 2009
Resolution: Director of Human Resources and QA stated all eligible deckhands are subject to random screening at 50% per year.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 April 2009 Resolved
Found 2008 MIS form due to DOT by 15Mar2009 had not been completed. Submit MIS form to DOT.
Due 15 May 2009
Resolved 24 April 2009
Resolution: Received copy of 2008 MIS form.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Damaged/cracked FRP fwd of stbd rudder. Grind to good FRP or good wood as nexessary and reglass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: Area was ground to good wood, reglassed and painted.
Construction/Loadline › Hull › Keel
Issued 18 February 2009 Resolved
Damaged FRP on both port and stbd keels below and aft of props. Remove damaged FRP to good wwod and reseal/FRP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: Ara ground to good wood, reglassed and pianted.
Engineering › Steering Gear System › Rudder
Issued 18 February 2009 Resolved
STB rudder damaged in lower fwd corner. Make repairs as identified.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: Rudder removed and repaired wiht new filler and FRP.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 February 2009 Resolved
Both drive shaft bearings worn beyond 50%. Replace same.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: New shaft water seals installed.
Engineering › Steering Gear System › Linkage
Issued 18 February 2009 Resolved
Stbd steering control linkage/ball corroded and siezed. Renew same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2009
Resolution: New steering rod end installed. Sterring system test sat.
Construction/Loadline › Hull › Bracket
Issued 18 February 2009 Resolved
Found port drive shaft strut bolts (02) severly corroded/necked, at strut housing. Replace with non-S/S fasteners.
Action required: 705 - Other - as specified
Resolved 26 February 2009
Resolution: New silicon-bronze fasteners installed.
Construction/Loadline › Hull › Bracket
Issued 18 February 2009 Resolved
Pull port drive shaft strut housing for further investigation of fatener holes and vsl's keel for damage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: Housing pulled and insepcted. No interior damage found. Holes were cleaned and lined "Z-spar" A-788 sealant to accepted the new, slightly lrgr dia fasteners.
Construction/Loadline › Hull › Sheerstrake
Issued 18 February 2009 Resolved
Pull fasteners on each hull, (I/B & O/B) to meet Wood NVIC requirements for vsl over 10 yrs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2009
Resolution: 16 fasteners pulled (04 on each side of each hull). S/S fasteners were in good shape after six years. Vsl is to have fasteners, pulled in similar fashion, below the water line at each subsequent dry-dock. See special note.
Construction/Loadline › Hull › Bottom Plating
Issued 18 February 2009 Resolved
Vsl has S/S striker plates on each stem with. Hardware appreared wasted. Pull four fasteners from each stem plate for further inspection.
Action required: 705 - Other - as specified
Due 18 February 2009
Resolved 26 February 2009
Resolution: Pulled fasteners were S/S with a large proportion having wasted heads. All fasteners were voluntarily pulled and renewed.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Evidence of deteriorated FRP and wood around port eng exhaust. Grind to good wood, investigate and repair as necessary.
Due 18 February 2009
Resolved 26 February 2009
Resolution: Deterioration consisted of damage to wood approx 1/8" of depth. Area was ground out, sealed, glassed and painted.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Damage FRP 5' from stem on port (o/b) side 1' below the water line. Grind to good wood and repair as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2009
Resolved 27 February 2009
Resolution: Area ground down dried out, sealed, reglassed and painted.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Damaged FRP on port keel 18' from stem at w/l. Grind to good wood. Repair as necessary. Call Cg if extensive damage is discovered.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2009
Resolved 27 February 2009
Resolution: Area ground down dried out, sealed, reglassed and painted.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Dealinated FRP on port keel approx 25' from stem. Grind to good wood and repair as nessecary. Call CG if evidence of extensive damage exists.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2009
Resolved 27 February 2009
Resolution: Area ground down dried out, sealed, reglassed and painted.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Soft and weeping FRP approx 12' from stern and 2' (b/l/w) on stb (o/b) hull.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2009
Resolved 20 February 2009
Resolution: Area ground-down dried out, sealed, reglassed and painted.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Owner identified and was making repairs to damaged aft cabin (port & stbd, outside of cabin) vertical wings from previously discovered and treated termite damage. Cut to good wood and renew.
Action required: 705 - Other - as specified
Due 18 February 2009
Resolved 20 February 2009
Resolution: Wings were cut and renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 February 2009 Resolved
Vsl indentified loose hand rail on deck ladder. Provide repair/strengthening proposal.
Action required: 705 - Other - as specified
Due 18 February 2009
Resolved 6 March 2009
Resolution: Reviewed proposal authorized to include horizontal bar at center of ladder stantion and to the vsl cabin''s exterior. Repair all SAT.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Pull lower fasteners on stbd aft and stbd fwd chain plates and 2nd fastener from, bottom on port aft and stb fwd chain plates on upper deck for examination.
Action required: 705 - Other - as specified
Due 18 February 2009
Resolved 20 February 2009
Resolution: Fasteners were made of S/S and in good condition. Fasteners were reinstalled 5200 as a sealant.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2009 Resolved
Found (06) upper deck chain plate fasteners recessed or not extending beyond the retaining hardware (nuts). Renew all fasteners to extend at least two thread lengths beyond nut.
Action required: 705 - Other - as specified
Due 26 February 2009
Resolved 6 March 2009
Resolution: Fasteners renewed.
Construction/Loadline › Structures › Superstructure
Issued 18 February 2009 Resolved
Mast and Rigging: Found (01) cracked clevis pin and (01) pitted clevis pin on lower mast shroud tangs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2009
Resolution: Both pins renewed along with (02) additional pins on stay tangs at mast head. Recomened rep include replacement within inspection schedule for future info.
Construction/Loadline › Structures › Superstructure
Issued 18 February 2009 Resolved
Mast/Rigging- found signs of corrosion on lower mast shroud tangs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2009
Resolution: Tangs were removed and brushed/cleaned for further inspection. Under microscope tangs appeared good for continued use. No evidence of deterioration discovered.
Construction/Loadline › Hull › Transverse Frame
Issued 18 February 2009 Resolved
Port hull - Fwd compartment. Found 10"x12" hole approx 12" above keel, inboard side. compared to stbd side - intact. Repair as necessary (crop and renew) to make water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2009
Resolution: Access was made through bottom of chain locker for ease of maintenance. Rep found deteriorated wood. Suspected existing small hole and moisture caused slow rot. Repair entailed cropping to good wood and renewing with a "California Lip", (sealed hatch)
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 February 2009 Resolved
Remove wire nut splices from water pump connections and renew with properly sealed splices
Due 20 March 2009
Resolved 5 March 2009
Resolution: Proper splices installed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 18 February 2009 Resolved
Three way discharge valve not properly secured.
Due 20 March 2009
Resolved 5 March 2009
Resolution: Chain and locked installed in the closed postiion.
Construction/Loadline › Penetrations › Valve Flange
Issued 18 February 2009 Resolved
Make sewage through hull valves available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2009
Resolution: Valve was removed, inspected sat and reinstalled with new spool pieces.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 18 February 2009 Resolved
Replace/renew fwd eng bulkhead to make space vapor tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2009
Resolution: Existing bulkhead was reinstalled and vapor sealed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 February 2009 Resolved
Stbd Eng bilge alarm switch not permanently secured.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2009
Resolution: Switch secured in bilge.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 February 2009 Resolved
Angel hair in stbd eng space, inboard, above bilge overboard discharge.. Sand to good wood and protect.
Due 20 March 2009
Resolved 26 February 2009
Resolution: Sanded to good wood and resealed.
Engineering › Bilge Water Management System › Pump
Issued 18 February 2009 Resolved
Stbd, aft, fixed hand bilge pump deteriorated. Renew same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2009
Resolution: New pump installed.
Engineering › Bilge Water Management System › Hose
Issued 18 February 2009 Resolved
Remove electrical tape from bilge overboard discharge line in stbd eng space for further investigation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2009
Resolution: Found tape to be unnecessary and not used as a hole stop. Owner removed tape and shortened length of line.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 18 February 2009 Resolved
Renew/replace missing lighting fixture covers in fwd two spaces of stbd hull.
Due 20 March 2009
Resolved 5 March 2009
Resolution: Covers reinstalled.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 February 2009 Resolved
Provide Rigging Inspection/Replacement schedule IAW CID Note #13.
Due 5 April 2009
Resolved 14 April 2009
Resolution: Verified that master had created rigging inspection plan.
Construction/Loadline › Structures › Superstructure
Issued 18 February 2009 Resolved
Vessel had previously removed aft railing for ease of operations (snorkeling) and provided line across aft cabin/deck accesses to prohibit pax movement. Provide request to remain removed and alterative level of safety suggestion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2009
Resolution: Authorized arrangement was to install three wire courses on each side of vessel across cabin/deck access and install a warning sign.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 March 2008 Resolved
Found 42 adult life jackets aboard vessel vice the 52 life jackets required by the COI. Provide 10 more adult life jackets to bring the total count to 52 as required. Vessel is restricted to the carriage of no more than 40 passengers.
Condition: Improper/Lack of Maintenance
Due 19 March 2008
Resolved 22 March 2008
Resolution: Sighted new lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 18 March 2008 Resolved
Found (4) child size life jackets on vessel with faded and non-reflective retro material. Apply retro-reflective material to (4) child sized life jackets. Note: Vessel required to carry (6) child life jackets and there were (10) child jackets aboard including (6) with acceptably reflective material.
Due 24 March 2008
Resolved 22 March 2008
Resolution: Okay per master''s word.
Operations/Management › Drills/Instruction › Fire
Issued 18 March 2008 Resolved
The attending deckhand was unfamiliar with procedures for fighting a fire. Corrected on the spot, but vessel is manned from a pool of employees of the Kualoa Ranch and there is no record of recent fire-fighting or man overboard training. Conduct and document fire and man overboard drills for those Kualoa Ranch employees expected to act as crew on the vessel.
Due 31 March 2008
Resolved 14 April 2008
Resolution: Sighted logs docuemting completed drills.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 March 2008 Resolved
Provide 2008 tide tables (calendar will suffice).
Condition: Improper/Lack of Maintenance
Due 24 March 2008
Resolved 22 March 2008
Resolution: Sighted 2008 tide tables.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 18 March 2008 Resolved
The Navigation Rules book carried aboard the vessel dates back to 1990. Provide a new Navigation Rules (COLREGS) book.
Due 24 March 2008
Resolved 22 March 2008
Resolution: Sighted new Navigation Rules book (COMDTINST M16672.2D)
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 March 2008 Resolved
The port running light is obscured by a small dive platform added to the vessel after initial construction. Remove the dive platform or move running light to provide the proper arc of visibility in accordance with the NAVRULES.
Due 24 March 2008
Resolved 22 March 2008
Resolution: The platform was removed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 March 2008 Resolved
The first aid kit has expired items. Provide a properly replenished first aid kit.
Due 24 March 2008
Resolved 22 March 2008
Resolution: Sighted updated items for the 1st aid kit.
Construction/Loadline › Structures › Superstructure
Issued 13 March 2007 Resolved
Conduct rigging survey.
Due 31 May 2007
Resolved 7 May 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 March 2007 Resolved
Certificate of Documentation (CG-1270) - Missing
Due 31 May 2007
Resolved 7 May 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 March 2007 Resolved
Mounting Bracket - Missing
Due 31 May 2007
Resolved 7 May 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 13 March 2007 Resolved
Interface Detector - Fractured
Due 31 May 2007
Resolved 7 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2007 Resolved
Wiring - Loose
Due 31 May 2007
Resolved 7 May 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 13 March 2007 Resolved
Lighting Fixture - Missing
Due 31 May 2007
Resolved 7 May 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 14 February 2006 Resolved
Repair leaking high pressuer fuel lines on both main engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2006
Resolved 15 February 2006
Resolution: Corrected.
Engineering › Fuel Oil Service System › Filter
Issued 14 February 2006 Resolved
Provide mechanical plugs for fuel filter bowls.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 15 February 2006
Resolution: Corrected
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 February 2006 Resolved
Remove excess fuel oil from fuel tank space bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2006
Resolved 15 February 2006
Resolution: Corrected
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 February 2005 Resolved
Provide sailing endorsement to Master's license IAW 46 CF 15.805.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 24 February 2005 Resolved
Provide a waste management plan IAW 33 CFR 151.57.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 24 February 2005 Resolved
Provide First Aid/CPR cards for 50% of crew IAW NVIC 1-91.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 February 2005 Resolved
Provide hull markings (vessel name) IAW 46 CFR 67.123.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 February 2005 Resolved
Prove proper operation of the stern light IAW COLREGS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 February 2005 Resolved
Prove proper operation of the compass light IAW 46 CFR 184.402.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 February 2005 Resolved
Provide (5) additional adult PFD's IAW COI. Vessel restricted to 44 passengers until provided.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 24 February 2005 Resolved
Prove proper operation of the high water level alarms in the port and starboard aft compartments IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 24 February 2005 Resolved
Make forward bulkheads in the port and starboard engine rooms vapor tight IAW 46 CFR 182.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 February 2005 Resolved
Complete training of new crew members and conduct fire, man overboard and abandon ship drills in the presence of a USCG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Communications › Alarms/Indicators
Issued 9 October 2002 Resolved
Prove bilge high level alarms. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Due 9 November 2002
Resolved 7 November 2002
Engineering › Fuel Oil Service System › Filter
Issued 9 October 2002 Resolved
Provide flame impingement bowls for the port and stbd main eng. fuel filters.
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 7 November 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 October 2002 Resolved
Provide mounting bracket for the portable fire extinguisher at the operating station.
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 7 November 2002
Engineering › Fuel Oil Service System › Filter
Issued 9 October 2002 Resolved
Provide a cap and plug on the fuel filter drains in accordance with 46 CFR 184.40 - 20 (b) (7)
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 7 November 2002
Documentation › Certificates/Documents
Issued 9 October 2002 Resolved
Provide FCC radio Station License. (Vessel limited to 1000 feet from shore). LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Due 9 November 2002
Resolved 7 November 2002
Navigation › Collision/Grounding Avoidance
Issued 9 October 2002 Resolved
Prove navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 7 November 2002
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 October 2002 Resolved
Provide navigation publications per 46 CFR 184.420
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 7 November 2002
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 9 October 2002 Resolved
Provide life line on the stbd side forward (main deck).
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 7 November 2002
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 9 October 2002 Resolved
Provide a life line on the lower rail course for the slide.
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 7 November 2002
Documentation › Certificates/Documents
Issued 9 October 2002 Resolved
Provide a valid Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2002
Resolved 7 November 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 March 2002 Resolved
Prove proper operation of main engines, rudders, propellers, and shafts in accordance with 46 CFR 182.220, 46 CFR 182.610. LEGACY COMPONENT DESC: Operation
Condition: Improper/Lack of Maintenance
Due 15 April 2002
Resolved 7 November 2002
Fire Fighting
Issued 18 September 2001 Resolved
Provide proper portable fire extinguishers as required on COI in accordancewith 46 CFR 181.500(a) table prior to operating with passengers.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Documentation
Issued 18 September 2001 Resolved
Provide original COI to vessel in accordance with 46 CFR 176.107.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Construction/Loadline
Issued 18 September 2001 Resolved
Make repairs in kind to cracked and seperating decking forward of the port sewage tank in accordance with 46 CFR 176.802.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Accommodation/Occupational Safety
Issued 18 September 2001 Resolved
Make repairs in kind or replace the port sewage tank in accordance with 46 CFR 184.704.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Lifesaving
Issued 18 September 2001 Resolved
Provide a new ring life buoy in accordance with 46 CFR 180.70.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Fire Fighting
Issued 18 September 2001 Resolved
Provide documentation for annual service of fixed fire fighting system (in port and starboard engine compartments), in accordance with 46 CFR 176.810.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Engineering
Issued 18 September 2001 Resolved
Repair/replace handle for port engine sea water intake valve in accordance with 46 CFR 176.610.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Construction/Loadline
Issued 18 September 2001 Resolved
Prove proper operation of the port hull bilge audible alarm in accordance with 46 CFR 182.530 prior to operating with passengers.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Construction/Loadline
Issued 18 September 2001 Resolved
Pump out bilges in accordance with 46 CFR 176.830.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
System not recorded
Issued 18 September 2001 Resolved
Provide documentation of drug screening program and employee assistance program in accordance with 46 CFR Part 16.
Condition: Unknown
Due 26 September 2001
Resolved 7 November 2002
Documentation
Issued 18 September 2001 Resolved
Provide sailing endorsement to Master's license in accordance with 46 CFR 15.805.
Condition: Unknown
Due 18 October 2001
Resolved 7 November 2002
Fire Fighting
Issued 18 September 2001 Resolved
Complete minor corrective maintenance to fixed fire fighting system bottleswhich have some surface rust and dirty heads in accordance with 46 CFR 176.810.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Fire Fighting
Issued 18 September 2000 Resolved
Provide documentation of annual servicing of fixed fire fighting system to include documentation of qualification of company mechanic who performed installation and servicing IAW 46 CFR 176.810(b)(2).
Condition: Unknown
Due 20 October 2000
Resolved 20 October 2000
Engineering
Issued 18 September 2000 Resolved
Gauge and/or replace starboard fuel tank which shows deep scaling, especially in vicinity of unused mounting bracket inboard IAW 46 CFR 182.440. If installing a new tank, it must be constructed and tested IAW 46CFR 182.440.
Condition: Unknown
Due 20 October 2000
Resolved 20 October 2000
Lifesaving
Issued 18 September 2000 Resolved
Provide sign limiting the upper deck to the carriage of no more than 31 passengers IAW 46 CFR 185.602(g).
Condition: Unknown
Due 20 October 2000
Resolved 20 October 2000
Fire Fighting
Issued 20 October 1999 Resolved
Provide and properly mount (3) B-II portable fire extinguishers in accordance with 46 CFR 181.500 prior to sailing with passengers.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Navigation
Issued 20 October 1999 Resolved
Provide a light for the magnetic compass in accordance with 46 CFR 184.402 (c).
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Documentation
Issued 20 October 1999 Resolved
Provide proof of compliance with an approved drug and alcohol program in accordance with 46 CFR 16.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Navigation
Issued 20 October 1999 Resolved
Provide a U.S. Coast Pilot and Tide Tables in accordance with 46 CFR 184.420.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Engineering
Issued 5 October 1999 Resolved
Obtain approval of the OCMI for installation of new engines, shafts, and propellers in accordance with 46 CFR 176.700 prior to sailing with passengers.
Condition: Unknown
Due 5 October 1999
Resolved 24 November 1999
Fire Fighting
Issued 5 October 1999 Resolved
Install fixed firefighting systems in the port and starboard machinery spaces in accordance with 46 CFR 181.400 prior to sailing with passengers.
Condition: Unknown
Due 5 October 1999
Resolved 21 October 1999
Fire Fighting
Issued 5 October 1999 Resolved
Provide readily available closure devices for ventilation ducts and the wing areas adjacent to the machinery spaces in accordance with 46 CFR 182.465 prior to sailing with passengers.
Condition: Unknown
Due 5 October 1999
Resolved 21 October 1999
Accommodation/Occupational Safety
Issued 19 September 1997 Resolved
Install deck rails at P & S quarters, outboard of boarding ladders and lazaret hatches, as required by 46 CFR 177.900.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Lifesaving
Issued 19 September 1997 Resolved
Apply vessel name and retroreflective material on ring life buoy, as required by 46 CFR 185.604(b) and 186.604(i).
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Navigation
Issued 19 September 1997 Resolved
Prove proper operation of navigation lights, as required by 46 CFR 183.420.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Navigation
Issued 19 September 1997 Resolved
Prove proper operation of installed VHF-FM radio. 46 CFR 184.502
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Documentation
Issued 19 September 1997 Resolved
Have all vessel documents updated to indicate the current owner & operator name and address.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Documentation
Issued 19 September 1997 Resolved
Show that current vessel master has a valid USCG Masters license and FCC Radio Operator permit. 46 CFR 184.502 and 185.402
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Documentation
Issued 19 September 1997 Resolved
Provide evidence of full compliance with the USCG Chemical Testing Program,as required by 46 CFR 16.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Documentation
Issued 19 September 1997 Resolved
Conduct and log crew training and drills as required by 46 CFR 185.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Navigation
Issued 19 September 1997 Resolved
Install steering limit stops, P & S, as required by 46 CFR 182.620(e).
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Remove rotten wood in the port engine room hatch area, port aft chain locker, and stbd lazarette compartment, treat existing wood, and renew as original.
Condition: Unknown
Due 8 September 1997
Resolved 26 September 1997
Electrical
Issued 8 August 1997 Resolved
Remove erroneous wiring from the 12-volt batteries and properly install a terminal board with overload protection for vessel power and lighting systems.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Remove rotted wood on stbd skeg and renew as original.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Grind and properly repair numerous blisters on the port and stbd hulls.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Properly repair cracks in bow area on both hulls.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Properly repair the puncture in the stbd hull.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Properly repair two storm damaged areas on the outboard side of the stbd hull.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Properly repair the damaged wooden ribs (longitudinal stiffeners) under thewing area.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Grind and properly repair the holes in the outside aft section of the port hull.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Properly repair the 3 ft. crack in the outboard side of the stbd storage compartment hull.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Engineering
Issued 8 August 1997 Resolved
Replace both cutlass bearings.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Engineering
Issued 8 August 1997 Resolved
Renew the ventilation piping in the stbd engine room.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Renew or remove the inoperable bilge high water level alarms from the port and stbd fuel tank compartments.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Remove rotten wood flooring, treat existing wood, renew flooring as_x001C_ original in the port and stbd storage compartments.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Demonstrate proper operation of the stbd lazarette bilge pump.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Properly repair the 3 ft. crack in the outboard side of the engine room hull.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Pull all 4 sea valves for inspection by USCG Marine Inspector.
Condition: Unknown
Due 26 August 1997
Resolved 27 August 1997
Navigation
Issued 8 August 1997 Resolved
Renew the wasted steering arm connection and bolt (hime joint) in the stbd lazarette.
Condition: Unknown
Due 8 September 1997
Resolved 26 September 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Remove oil from the bilges in the engine compartments and fuel tank compartments of both hulls.
Condition: Unknown
Due 8 September 1997
Resolved 26 September 1997
Construction/Loadline
Issued 8 August 1997 Resolved
Demonstrate proper operation of the bilge high water level alarm in the port engine room.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Engineering
Issued 8 August 1997 Resolved
Provide 30 x 30 mesh flame screens for both fuel tank vents.
Condition: Unknown
Due 8 September 1997
Resolved 26 September 1997
Engineering
Issued 8 August 1997 Resolved
Make tight all engine mount bolts on both engines.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Engineering
Issued 8 August 1997 Resolved
Renew exhaust header pipes and provide lagging for both engines.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Documentation
Issued 27 September 1996 Resolved
PROVIDE PROOF OF COMPLETION OF THE CHEMICAL TESTING PROGRAM'S 60 MINUTE SUPERVISOR TRAINING IAW 46 CFR 16.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Engineering
Issued 27 September 1996 Resolved
INSTALL NON-CORROSIVE AND REMOVABLE 30 X 30 MESH FLAME SCREENS ON BOTH FUELTANK VENTS IAW 46 CFR 182.20-35(d).
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Lifesaving
Issued 27 September 1996 Resolved
PROVIDE 4 RED AND 6 ORANGE APPROVED DISTRESS SIGNALS IAW 46 CFR 180.35-5.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Engineering
Issued 27 September 1996 Resolved
INSTALL PROPER VERTICAL VENTILATION DUCTING IN BOTH ENGINE ROOMS IAW _x001C_ 46 CFR 182.20-45.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Unknown
Issued 20 October 1995 Resolved
Prior to carrying passengers, provide proof of charters drug testing program and conduct underway machinery trials and emergency drills with thecharterers hired Master and crew in the presence of a CG Marine Inspector.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 25 August 1995 Resolved
Provide USCG approved water light for ring buoy.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Documentation
Issued 25 August 1995 Resolved
Maintain garbage log and post Waste Management Plan visible to crew and passengers.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Documentation
Issued 25 August 1995 Resolved
Provide valid FCC Safety Certificate Form 824. Vessel is restricted to 1000 ft from shore until this item is completed.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Documentation
Issued 25 August 1995 Resolved
Post stability letter with all pages visible.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
Prior to carrying passengers, provide a total of six servicable red and_x001C_ six servicable orange smoke flares.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
Provide 32 servicable adult type I life preservers and six child type I life preservers. Passenger capacity reduced to 17 adults only until this item is completed. Presently, reflective tape is defective on subject lifepreservers.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
Prior to carrying passengers, conduct underway machinery trials and emergency drills in the presence of a USCG marine inspector.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Documentation
Issued 25 August 1995 Resolved
Prior to carrying passengers, provide Master License, FCC Operator's License, and drug testing policy and results for 50% of the crew within thelast year.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
Permanently repair lifelines at entrance to slide.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Electrical
Issued 25 August 1995 Resolved
Properly deadend stray wiring in junction boxes located in the operating station console.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Provide one hand portable bilge/fire pump with suitable suction and discharge hoses.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Navigation
Issued 25 August 1995 Resolved
Provide current editions of the following nautical publications: Navigation Rules, Tide and Current Tables and charts of operational area.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Navigation
Issued 25 August 1995 Resolved
Install at the operating station a suitable magnetic compass with light.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Navigation
Issued 25 August 1995 Resolved
Install at the operating station an 8" bell with it's bracket.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Electrical
Issued 25 August 1995 Resolved
Properly deadend stray wiring in junction boxes in port and starboard engine rooms.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Fire Fighting
Issued 25 August 1995 Resolved
Make engine room boundaries gas tight, fixed-fire extinguishing system to be properly sized for engine room spaces; extinguishing system must have manual pull, indicating light and activation alarm.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Fire Fighting
Issued 25 August 1995 Resolved
Provide documentation that vessel was constructed with fire-retardant resinor meets fire protection equivalencies of NVIC 8-87. Provide fixed-fire extinguishing system, heat detection system and non-combustible linings forengine room boundaries.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 25 August 1995 Resolved
Prior to carrying passengers, renew or repair defective fresh water pump onport main diesel engine.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Fire Fighting
Issued 25 August 1995 Resolved
Prior to carrying passengers, conduct annual servicing on portable fire extinguishers (3 each) and Halon cylinders (2 each).
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Permanently repair and prove operation of hand bilge pump in forward port compartment.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Fire Fighting
Issued 25 August 1995 Resolved
Provide two additional B-II portable fire extinguishers for a total of two for each engine room.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
Prior to carrying passengers, remove plastic fuel tanks, charcoal lighter fluid and household BBQ grill from vessel.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Relocate port and starboard high level bilge alarms to engine compartments and prove operation of audible and visual alarms at operating station. Remove wire nuts from high level bilge alarm wiring and install pressure type connectors.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Permanently repair delaminated bonding angles on under deck longitudinal stiffeners at bow (7 each).
Condition: Unknown
Due 25 August 1995
Resolved 30 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Remove rotten wood flooring, treat existing wood, renew flooring as original in the port and starboard berthing compartments._x001C_ _x001C_
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Prove operation of all sea valves (4 each).
Condition: Unknown
Due 25 August 1995
Resolved 31 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Provide capture devices for forward and aft main deck hatch covers _x001C_ (8 each).
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Accommodation/Occupational Safety
Issued 25 August 1995 Resolved
Remove and plug 1 1/2" PVC piping in overhead of port engine room.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 25 August 1995 Resolved
Renew fractured wood support for reduction gear lube oil cooler saltwater hoses in port engine room.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 22 September 1994 Resolved
MISSING EMERGENCY CHECK-OFF LIST. 835 ISSUED 22SEP94.
Condition: Unknown
Due 29 September 1994
Resolved 26 September 1994
Lifesaving
Issued 17 November 1993 Resolved
Properly stow lifering buoy and waterlight.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Fire Fighting
Issued 17 November 1993 Resolved
Provide a B-I extinguisher at the helm station.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Construction/Loadline
Issued 17 November 1993 Resolved
Install bilge pumps in both engine compartments.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Accommodation/Occupational Safety
Issued 17 November 1993 Resolved
Relabel remote fuel shut-off valves and PFD stowage areas.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Lifesaving
Issued 17 November 1993 Resolved
Conduct drills with crew for man overboard, fire, and flooding.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Accommodation/Occupational Safety
Issued 17 November 1993 Resolved
Install rails and lines on stern area.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Engineering
Issued 17 November 1993 Resolved
Install correct propellers on both shafts.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Electrical
Issued 17 November 1993 Resolved
Complete rewiring of vessel in accordance with current plans.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Navigation
Issued 17 November 1993 Resolved
Prove proper operation of the running lights.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Navigation
Issued 17 November 1993 Resolved
Prove proper operation of the VHF-FM radio.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Documentation
Issued 17 November 1993 Resolved
Provide current FCC certificates.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Documentation
Issued 17 November 1993 Resolved
Provide proof of compliance with random drug testing regulations.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Navigation
Issued 17 October 1991 Resolved
REPLACE THE STEERING TRANSFER ARM TO BOTH RUDDER ASSEMBLIES.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Engineering
Issued 17 October 1991 Resolved
RENEW THE HANDLE ON THE STARBOARD MAIN ENGINE COOLING SEA VALVE.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Documentation
Issued 6 April 1990 Resolved
CONDUCT A SIMPLIFIED STABILITY TEST IN ACCORDANCE WITH 46 CFR 171.030 IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 6 April 1990
Resolved 6 April 1990
Electrical
Issued 10 October 1989 Resolved
PLACE A LEAD, PLASTIC OR FIBERGLASS LINING IN BOTH BATTERY TRAYS ( 46 CFR 183.05-20(D).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989 Resolved
REPACK THE PORT AND STARBOARD RUDDER POST STUFFING BOXES.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Documentation
Issued 10 October 1989 Resolved
PLACE THE ORIGIONAL CERTIFICATE OF DOCUMENTATION ON BOARD THE VESSEL.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Engineering
Issued 10 October 1989 Resolved
REPLACE ALL NON METALLIC FLEXIBLE FUEL HOSES FOR THE FUEL SYSTEMS WITH ONESOF AN APPROVED TYPE. AEROQUIP FC300 IS NOT ACCEPTED FOR FUEL SERVICE.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989 Resolved
PROPERLY MOUNT A SUITABLE MAGNETIC COMPASS AT THE STEERING STATION (46 CFR 184.20-1).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Construction/Loadline
Issued 10 October 1989 Resolved
PROVIDE SUITABLE INSPECTION ACCESSES FOR THE FOREPEAK COMPARTMENTS, FORWARDCOMPARTMENTS AND THE AFT COMPARTMENTS IN BOTH HULLS. ACCESSES ARE TO BE LARGE ENOUGH FOR A PERSON TO ENTER. SUBMIT A WRITTEN PROPOSAL FOR APPROVALPRIOR TO PERFORMING ANY ALTERATIONS.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Construction/Loadline
Issued 10 October 1989 Resolved
INSTALL A SUITABLE BILGE PUMP IN THE FORWARD COMPARTMENTS AND AFTER COMPARTMENTS IN EACH HULL (46 CFR 182.25).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989

Casualty record · 1

6 December 2021Routine · role: Involved in a Marine Casualty · activity 7371347
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.