10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 November 2024
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: A self-propelled vessel of 65 feet or more in length, engaged in commercial service. Vessel's AIS is not operational due to inability to broadcast. Provide root cause and repair AIS to the satisfaction of the Marine Inspector. 33 CFR 164.46(b)(1)(i)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2024
Resolution: Vessel replaced antenna and VTS verified sat operation of AIS
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 November 2024
Resolved
Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. Marine inspector observed crack to corner of topmost buoyant apparatus on aft stack. 46 CFR 122.720(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 18 November 2024
Resolution: Received photograph of repair to BA. Uploaded to activity
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 November 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Operation of the fire main system. MI observed leaking valve stems at deck two fire hydrant, and in engine room at fire pump. 46 CFR 120.220(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 18 November 2024
Resolution: Witnessed repair to leaking valve stems.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 November 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified. Breaker panel in vicinity of bar on deck one has unlabeled switches. 46 CFR 115.810(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 17 January 2025
Resolution: Administratively reviewed corrective actions. Operator relabeled breakers
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 February 2024
Resolved
Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed inspection window. Receive inspection prior to carriage of passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2024
Resolution: Completed inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2024
Resolved
Each lighting fixture…must have a guard…Lazarette lighting found with holed protective cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 15 February 2024
Resolution: Operator reinstalled lighting guard.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 February 2024
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2). Vessel’s VHF radio installation consisted of a radio that was not connected to GPS. Make repairs and have inspected by FCC certified radio technician for compliance with Radio Safety Telephony Certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 15 February 2024
Resolution: Operator found a loose wire and reconnected to provide GPS.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 February 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: Charts large enough scale to make safe navigation possible. Vessel did not have a current chart onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 15 February 2024
Resolution: Current chart purchased and put onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024
Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so that the child size life jackets are not mistaken for adult life jackets. Marine Inspector found one child life jacket in box labeled for adults. Rectified prior to end of inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 February 2024
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 February 2024
Resolved
Each disposable hydrostatic release unit must be marked in clearly legible letters with an expiration date of two years after the date on which the unit was installed. Marine Inspector found HRU with incorrect dates. Master fixed prior to end of inspection.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 13 February 2024
Resolution: Corrected on the spot
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 October 2022
Resolved
A hatch exposed to the weather on a vessel that operates on protected waters must be weathertight. The vessel’s forepeak hatch was not weathertight and needs to be made as such.
46 CFR 116.1160(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 9 December 2022
Resolution: Verified water tight integrity of hatch. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2022
Resolved
Doors in “A” Class bulkheads shall have a latch with a minimum throw of ¾ inch which can be operated from either side of the door. The vessel’s fire doors for the galley and the stairways were missing a latch for the doors. Door handle and latch shall be replaced and shall be of sufficient grade to ensure "A" class fire resistance of door.
46 CFR 72.05-25 (b)(3)
46 CFR 177.10-5 (a) (OLD T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 9 December 2022
Resolution: Corrected deficiency. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2022
Resolved
Holdback hooks, or other means of permanently holding the door open, not subject to control station release, for doors in stairway enclosures and Main Vertical Zone bulkheads are not allowed. The vessel had holdback hooks for doors in stairway enclosures on the second deck and needs to be either removed or replaced with control station release device.
46 CFR 72.05-25(b)(9)(ii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 11 November 2022
Resolution: Vessel removed holdback devices.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 October 2022
Resolved
All vessels shall be provided with not less than two avenues of escape where crew may be normally employed. The Forward storeroom emergency escape scuttle dogging mechanism was inoperable and needs repaired.
46 CFR 177.15(a) OLD T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 9 December 2022
Resolution: Verified SAT operation of hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 October 2022
Resolved
6. Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due location and route of vessel. Several windows were improperly sealed exposing gaps to the weather. One window on the port side main deck has a crack in the lower left hand corner. Much of the steel that supports the windows is severely corroded to unknown conditions and need repaired due to structural deterioration and concern of strength. Vessel shall develop window replacement plan to repair/replace windows. In the mean time due to the cost and in depth scope of work, the vessel shall ensure all windows on main deck and 2nd level deck are made weather tight.
46 CFR 116.1020
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 9 December 2022
Resolution: All windows were sealed to be weathertight and vessel submitted plan to replace windows in increments.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 October 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have vessel ready for the inspection of all accessible parts of the exterior and interior of the hull. Vessels mount for the masthead light was severely deteriorated and needs replaced.
46 CFR 115.802(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 28 October 2022
Resolution: Vessel manufactured and replaced masthead light mount.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 October 2022
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. 03 Buoyant Apparatuses were found to have cracks, holes, and deterioration and need replaced with sufficient Life Floats.
46 CFR 117.175(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 2 November 2022
Resolution: Vessel replaced 03 BA's with lifefloats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2022
Resolved
A weather tight door must be provided for each opening located in a deck house or companionway. The STBD side galley door is not weather tight and needs to be made as such.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 9 December 2022
Resolution: Vessel replaced seals on STBD galley door. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2022
Resolved
A weather tight door must be provided for each opening located in a deck house or companionway. STBD aft door on the 2nd deck is not weather tight and needs to be made as such. 46 CFR 116.1160(a)(2)
46 CFR 116.1160(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 9 December 2022
Resolution: Vessel replaced door seals. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2022
Resolved
Alterations to equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel to submit plans for the installation of the electric powered horn.
46 CFR 115.700 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 21 May 2024
Resolution: Vessel installed horn properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 October 2022
Resolved
The installation of portable fire extinguishers must be to the satisfaction of the cognizant [name withheld] extinguisher in upperdeck bar was loose and sitting on the deck. Fire extinguisher needs to be mounted.
46 CFR 118.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 28 October 2022
Resolution: Vessel mounted fire extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2022
Resolved
An exterior lighting fixture in an electrical system operating at more than 50 volts must comply with the requirements of UL 595. The glass globe for the port aft deck light on the stern is missing and needs replaced.
46 CFR 120.410(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 9 December 2022
Resolution: Glass globe is repalced. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 October 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have vessel ready for the inspection of all accessible parts of the exterior and interior of the hull. The vessel’s frames for the two exterior forward doors on the second deck showed significant deterioration near bottom and around window.
Vessel made temp repairs to framing and will make permanent repairs at next drydock.
46 CFR 115.802(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 7 November 2024
Resolution: MI observed area free of deterioration during annual exam. Rep states areas were repaired during dry dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 October 2022
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Numerous pieces of steel lattice used in beteween rail courses was loose or popping out posing a threat to passengers and crew. Deckhands sufficiently secured the lattice once identified during the inspection. All SAT. 46 CFR 177.35-1(a) OLD T
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 May 2023
Resolution: This deficiency was corrected on the spot during the previous inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 December 2021
Resolved
Kerosene and commercial standard fuel oil No.1, NO2, and No 3 are prohibited for cooking, heating or lighting on ferry or passenger vessels. Vessel must supply letter from Coast Guard approving tea lights by December 10 2021 in order to not receive action 60 or to remove all tea lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 December 2021
Resolution: Vessel Rep e-mailed MI to notify CG that the vessel would be removing all tea ligths on vessel to come into compliance.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 December 2021
Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas where crew may be normally employed. The door that separated galley to main salon had 1 bolt missing in the hinge. The door was able to close and open with manipulation by lining up the hinges. The door leading from galley to stores below that led to engine room was sticking and hard to open. Vessel will be completing drydock on January 3 2021 and will be required to address structural issues that are placing weight on doors that are dis-aligning hinges. Vessel will be required to temporarily fix the doors to provider easier move-ability to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2021
Resolved 16 December 2021
Resolution: MI attened vessel to view repairs, 02 bolts were replaced on hinges and paint build up was sanded down to prevent from sticking. Doors operated easily with little effort. All SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 December 2021
Resolved
Vessels operated solely within 20 nautical miles must be equipped with a VHF-DSC radiotelephone installation. This vessel is required to carry 02 VHF-DSC installations. One of the vessel's radios is not connected to GPS and therefore rendering DSC inoperable. The 2nd radio has a screen that is unreadable due to damage and it is unclear as to what channels and functions the radio is operating on. Repair 1st radio to conform to DSC. Repair or replace second radio and ensure compliance to DSC capability. 47 CFR 80.905
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2021
Resolved 16 December 2021
Resolution: Vessel Rep sent pcture of final installation of new radio; showing vessel information on screen and on chart plotter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 November 2021
Resolved
"All vessels shall be provided with not less than two avenues of escape from all general areas where crew may ne quartered or normally employed." Stbd main deck galley escape door; emergency door seized. Fix prior to Jan 2022 dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 January 2022
Resolution: Bottom framing cropped and renewed, and door replaced in-kind - 2022 DD
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 November 2021
Resolved
"Each item of survival craft equipment must be efficient for the purpose it is intended to serve." Light for floats inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 November 2021
Resolved 17 November 2021
Resolution: Replaced battery.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 November 2021
Resolved
"Each item of survival craft equipment must be efficient for the purpose it is intended to serve." Expired hydrostatic release.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 November 2021
Resolved 17 November 2021
Resolution: Replaced hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 November 2020
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each buoyant apparatus. The number of persons capacity must be marked or painted in clearly legible letters and numbers on each buoyant apparatus. Vessel had 02 BA without the vessel's name and capacity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 22 February 2021
Resolution: Rep provided pictures of proper markings on BA's.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 June 2020
Resolved
Rugs and carpets shall not extend up vertical surfaces more than 4". Carpets are not permitted where the spillage or leakage of flammable liquids is possible including areas immediately adjacent to bar service areas. Carpet in excess of 4" around outboard seating and carpet around bar areas on both interior decks. Make proper repairs to satisfaction of attending marine inspector.
46 CFR 116.423
Action required: 705 - Other - as specified
Due 16 September 2020
Resolved 17 November 2021
Resolution: Carpet around seating and bars on both decks cut back to acceptable level.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 December 2019
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.050. Ring life buoy line on the second deck is worn and must be replaced. Vessel must rectify deficiency within 7 days.
46 CFR 117.70 (b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2019
Resolved 19 December 2019
Resolution: Vessel rep sent MI picture of new ring life buoy line.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 December 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Deck directly under urinal in men's restroom has been been temporarily patched with a hard putty. Restore deck to original condition at next drydock period.
46 CFR 115.802 (a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 January 2020
Resolved 16 June 2020
Resolution: Verified permanent repairs to wasted deck.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 17 December 2019
Resolved
The master or person in charge of a ship to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Vessel was missing garbage placard at the time of inspection.
33 CFR 151.59
Action required: 10 - Deficiency Rectified
Due 17 December 2019
Resolved 17 December 2019
Resolution: Vessel rep sent MI a picture of a newly purchased garbage placard.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 January 2019
Resolved
46CFR 177.10-5 & 46CFR 72.05 - The general constuction of hte vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Insulation missing from underneath a portion of the forward stairway.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 25 January 2019
Resolution: Photo submitted by operator shows new insulation installed underneath forward stairway.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 January 2019
Resolved
46CFR 171.124(b) - Each hatch cover must have a securing device. Forward deck hatch missing securing device.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 25 January 2019
Resolution: Operator submitted photo showing an appropriate retention device (chain) secured from the hatch to the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 January 2019
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Marking for fuel shutoff station was hidden underneath the deck plate. Marking must be moved to be in a visible location.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 January 2019
Resolved 25 January 2019
Resolution: Operator submitted photo displaying new signage for remote fuel shutoff in an appropriate conspicuous location.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 January 2019
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Stowed so that when the vessel sinks the survival craft floats free and inflates automatically. Vessel IBA painter line was attached to the deck of the vessel and not to the float free link. Preventing the IBA to float free as designed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 3 October 2018
Resolved
CLSN: Vsl is broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 December 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 October 2017
Resolved
First Aid Kit contained expired medicines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 26 October 2017
Resolution: Expired Medicines were removed from the vessel.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 October 2017
Resolved
PORT AND STARBOARD MAIN DIESEL ENGINE SHAFTING DOES NOT HAVE SUITABLE GUARDS INSTALLED. SUITABLE GUARDS SHALL BE INSTALLED IN WAY OF EXPOSED HAZARDS. INSTALL GUARDS OVER PORT AND STARBOARD PROPULSION SHAFTING AND ROTATING PARTS.46 CFR 177.35-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 30 November 2017
Resolution: Guards were installed over rotating machinery.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 26 October 2017
Resolved
ELECTRICAL OUTLET COVERS BROKEN IN THE TOP DECK STORAGE ROOM PORT BULKHEAD AND ON BULKHEAD IN STORAGE ROOM NEXT TO 2ND DECK BAR. EXPOSED WIRES ARE PRESENT ON THE FORWARD SECTION OF THE SUPERSTRUCTURE AT THE BOW ON THE MAIN DECK AND EXPOSED WIRES IN THE STORAGE SPACE AFT OF THE ENGINE ROOM ON THE UPPER STARBOARD AFT BULKHEAD BENEATH THE SPACE ENTRANCE. INSTALLATION SHOULD BE SAFE FROM FIRE AND/OR ELECTRICAL SHOCK.REPLACE 110V OUTLET COVERS AND ADDRESS EXPOSED WIRING TO MEET 46 CFR 183.46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 8 December 2017
Resolution: Both Receptacle covers were replaced.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 October 2017
Resolved
SEWAGE PIPE LEAKING ON GALLEY STORES IN STORAGE ROOM AFT OF ENGINE ROOM ON STARBOARD SIDE. STORAGE SPACES ARE REQUIRED TO BE IN A SANITARY CONDITION. REMOVE AND CLEAN SEWAGE COVERED ITEMS. REPAIR LEAKING PIPE. PERMANENT REPAIR OF PIPING MUST BE COMPLETED PRIOR TO CREDIT DRY-DOCK. 46 CFR 176.25-45 (a). Temporary Repair completed to make it to drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 22 February 2018
Resolution: Pipe tested and determined to be intact. Leak from unknown source cleaned up.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 October 2017
Resolved
ALL 5 HIGH WATER BILGE ALARM INDICATION LIGHTS ILLUMINATE WHEN ANY ONE SPACE IS TESTED. A VISUAL ALARM MUST BE PROVIDED THAT INDICATES A HIGH WATER LEVEL IN EACH REQUIRED SPACE. WIRE EACH INDIVIDUAL INDICATOR LIGHT TO ILLUMINATE ONLY WHEN ITS CORRESPONDING SPACE IS ACTIVATED.46 CFR 119.115 (c)
46 CFR 119.530.(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 8 December 2017
Resolution: Bilge Alarm Panel was rewired and all alarms now work individually.
Operations/Management › Drills/Instruction › Fire
Issued 26 October 2017
Resolved
Vessel did not conduct a fire drill since March 2017.
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 26 October 2017
Resolution: Completed fire drill with crew.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 26 October 2017
Resolved
Crew has not conducted an abandon ship drill since March 2017.
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 26 October 2017
Resolution: Conducted abandon ship drill with crew.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 October 2017
Resolved
Vessel has not conducted a MOB since June 2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 26 October 2017
Resolution: Conducted successful MOB drill.
Engineering › Bilge Water Management System › Piping
Issued 26 October 2017
Resolved
MECHANICAL COUPLING USED IN FWD ENGINEROOM BILGE SUCTION LINE IS NOT ALLOWED IN A VITAL SYSTEM IAW WITH 46 CFR 56.30-35. REMOVE COUPLING AND REPAIR SECTION BACK TO ORIGINAL PRIOR TO NEXT CREDIT DRY DOCK. 46 CFR 182.40-5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 23 February 2018
Resolution: (6) gasketed mechanical couplings removed, pipe unions and new pipe added.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 26 October 2017
Resolved
1 of 6 Buoyant Apparatus did not have reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 26 October 2017
Resolution: Retroflective Tape was added to the buoyant apparatus.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 26 October 2017
Resolved
2 water lights had expired batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 26 October 2017
Resolution: Battery was replaced in both lights.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 18 October 2017
Resolved
PLASTIC WASTE RECEPTACLES ARE BEING USED THROUGHOUT THE VESSEL. COVERED METAL TRASH CONTAINERS SHALL BE PROVIDED IN LOUNGE AREAS AND THE SPACES SHALL BE MAINTAINED TO MINIMIZE FIRE AND SAFETY HAZARDS AND TO PRESERVE SANITARY CONDITIONS. REPLACE PLASTIC WASTE RECPTACLES WITH METAL RECEPTACLES. 46 CFR 177.30-7 (d)
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 30 November 2017
Resolution: Waste receptacles have been replaced.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 18 October 2017
Resolved
CATHODIC PROTECTION SYSTEM IN ENGINEROOM WIRING IS EXPOSED AND TAPED UP AND NOT CURRENTLY IN USE. APPEARS TO BE A NEW INSTALLATION IN PROGRESS. NO MAJOR REPAIRS OR ALTERATIONS AFFECTING THE SAFETY OF THE VESSEL SHALL BE MADE WITHOUT THE KNOWLEDGE AND APPROVAL OF THE [name withheld] APPROVAL OR SUBMIT PLAN REVIEW DOCUMENTATION AS REQUIRED PRIOR TO COMPLETION OF INSTALLATION. 46 CFR 176.20-1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 22 February 2018
Resolution: Cathodic system was existing, accepted tech report showing system returned to operational status.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 October 2017
Resolved
GALLEY HOOD EXHAUST HAS EXCESSIVE AMOUNTS OF COOKING GREASE ON THE WALLS OF THE EXHAUST PIPING CREATING A FIRE HAZARD. REMOVE GREASE FROM ALL EXHAUST PIPING OF GALLEY HOOD. 46 CFR 176.25-50 (b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 31 October 2017
Resolution: AAA Fire Protection Services Steam cleaned exhaust system.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 October 2017
Resolved
Battery expired in light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 26 October 2017
Resolution: Battery was replaced and corrected on the spot.