← All vessels
TOPAS
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named TOPAS
TOPAS is a 1998 freight ship. The Coast Guard has recorded 36 inspections since 2000, most recently in February 2006, along with 17 deficiencies and 20 operational controls.
Records from 2000 to 2006. Most recent: inspection, 24 February 2006.
- Built
- 1998
- Last inspected
- 24 February 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9215517 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2BF
3196
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-3196
Inspections, by type
…with no type recorded30
Years with a record
6 calendar years (2000–2006)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2218 - Convention (Subpart B), Net Ton
76639 - Displacement, Ton
5094 - Dead Weight, Ton
4028 - Convention (Subpart B), Gross Ton
76639 - Displacement, Ton
5094 - Dead Weight, Ton
4028 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
24 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2591933
21 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2589235
23 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2571583
10 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2564700
7 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2562724
13 December 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2551323
28 November 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2542258
17 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2515922
16 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2515549
2 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2507474
1 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2505294
18 September 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2495355
3 September 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2482409
20 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2468823
26 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2440151
26 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2402816
11 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2386692
26 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2369461
13 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2356809
1 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2346622
29 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2345399
13 April 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2333341
3 April 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2325401
2 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2324981
16 December 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1965296
14 December 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1964116
27 March 2003
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1764201
13 August 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1660795
5 July 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1641569
1 August 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 518283
6 July 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 291677
22 June 2001
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1068630
21 June 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 291258
21 May 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 290229
26 June 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 279299
9 May 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 277758
Deficiency record · 17
Lifesaving › Lifeboat › Carriage Requirement
Issued 3 April 2005
Resolved
Replace 6 packs of food rations for the only free fall lifeboat. Rations are not airtight.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 April 2005
Resolved
Deck water is leaking onto main switchboard in control room from overhead. Make proper repairs to the satisfaction of Class / Flag state rep.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 April 2005
Resolved
Missing glass covers for light bulbs in laundry room and workshop IWO engine control room.
Navigation › Collision/Grounding Avoidance
Issued 16 December 2003
Resolved
Both radars are not working due to the power board being out of order. LEGACY COMPONENT DESC: Radar
Pollution Prevention/Response › Prevention Equipment
Issued 16 December 2003
Resolved
The ows system piping has been altered from the original arrangement. Oily water of greater than 15ppm is being directed into the engine room bilges vice the dirty water holding tank. Vessel prohibited from operating ows in U.S. waters until piping arrengement corrected and verified. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Electrical › Electrical Distribution System (service)
Issued 16 December 2003
Resolved
The 380v and 220v A/C electrical distribution systems have dead grounds. Locate grounds and make repairs. LEGACY COMPONENT DESC: Ground Detection
Pollution Prevention/Response › Prevention Equipment
Issued 5 July 2002
Resolved
Oil water separator found inoperable IAW MARPOL 73/78 Annex I/16. Vls must retain all oily bilge water on board until repairs are made to the satisfaction of class or when adequate reception facilities are available. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Electrical › Lighting (service)
Issued 5 July 2002
Resolved
Light fixture in paint locker damaged/improperly installed IAW SOLAS 74 amended II-1/45.10. LEGACY COMPONENT DESC: Lighting Fixture
Lifesaving › Lifeboat
Issued 5 July 2002
Resolved
Vsl shall replace retro reflective tape as needed on rescue boat, lifeboat, and lifebuoys IAW SOLAS 74 ammended III/20. LEGACY COMPONENT DESC: Markings
Engineering
Issued 6 July 2001
Resolved
PROVIDE CLASS REPORT TO MSO JACKSONVILLE WHEN THE CONTROLLABLE PITCH PROPELLER SYSTEM IS OPERATIONAL.
Construction/Loadline
Issued 21 June 2001
Resolved
REPLACE GASKET ON THE STBD SIDE ENGINE ROOM SOFT PATCH AND PROVE WATERTIGHT.
Engineering
Issued 21 June 2001
Resolved
PROVIDE CLASS REPORT TO MSO JACKSONVILLE CONTAINING CAUSE OF PROBLEM, REPAIR AND SATISFACTORY TEST RESULTS OF THE CPP PROPELLER.
Documentation
Issued 21 May 2001
Resolved
Provide Oil Transfer Procedures.
Navigation
Issued 9 May 2000
Resolved
Install a recorder for the echo depth sounder in accordance with 33 CFR 164.35(h)_x001C_ _x001C_ _x001C_
Navigation
Issued 9 May 2000
Resolved
Provide a maneuvering information sheet that has all the elements in accordance with 33 CFR 164.35(g).
Fire Fighting
Issued 9 May 2000
Resolved
Prove proper operation of the bridge start/stop switch for the #1 fire pump._x001C_ _x001C_ _x001C_
Electrical
Issued 9 May 2000
Resolved
Provide instructions on how to operate the emergency generator in all modesof operation.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.