MAURY USCG vessel records Sign in
← All vessels

LA RUMBA

LA RUMBA is a 1988 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1988, most recently in October 2024, along with 205 deficiencies, 2 operational controls and 1 casualty investigation in 2017.

Records from 1988 to 2024. Most recent: inspection, 1 October 2024.

Built
1988
Last inspected
1 October 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ3479
319822
Flag
UNITED STATES
368061230
Maury page id
psix-319822

Inspections, by type

…with no type recorded16
Years with a record 29 calendar years (1988–2024)
The 77 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 26.0 ft × 5.6 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS INC · TARPON SPRINGS, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portSAN JUAN, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK5054MMSI 368061230 · active · compulsorily equipped · granted 5 October 2018, expires 5 October 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 77

1 October 2024 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8012319
3 August 2022 Administrative Inspection · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7535136
10 December 2018 Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6595222
25 September 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6548729
20 September 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6290939
19 May 2017 In-Service Inspection · Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6124497
1 November 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033006
2 November 2015 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5755717
3 September 2015 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5238615
14 August 2015 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5215860
3 August 2015 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5204668
22 October 2014 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5009617
14 December 2009 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3649969
7 October 2008 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3351140
4 December 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3109604
17 July 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2998251
18 September 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2781006
1 September 2005 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2480900
13 July 2005 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2425195
12 April 2005 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2331826
9 November 2004 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2237475
25 November 2003 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1954004
3 September 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1895351
25 June 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1839262
24 September 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1682313
5 June 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1626551
2 January 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1474790
28 June 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405181
26 April 2001 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1437897
23 January 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1397559
29 September 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1361729
11 August 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 821729
31 July 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1464962
27 September 1999 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1395271
26 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115746
15 April 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1452493
22 October 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1454677
20 October 1998 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 803065
25 September 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1428837
1 May 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1096746
15 October 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 843865
5 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945507
30 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938316
25 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 76631
25 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 204285
25 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765417
25 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085238
12 September 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1182567
27 April 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877016
22 September 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172075
6 April 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835148
22 February 1993 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1144133
20 January 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 78768
24 September 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1267445
10 September 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947265
8 February 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 950978
30 October 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 938610
4 September 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1314226
26 June 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 935975
14 May 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1216748
10 May 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1234941
25 April 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1241712
28 January 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918215
27 August 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 911992
13 April 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 927416
21 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900657
20 November 1989 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899501
2 November 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 996132
21 September 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204356
25 August 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1202992
13 July 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1195949
20 June 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347052
27 April 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1043562
14 February 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1345647
3 February 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897900
30 November 1988 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1035445
30 November 1988 Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1348919

Deficiency record · 205

Communications › Alarms/Indicators › Bilge Alarm
Issued 6 July 2017 Resolved
Prove proper operation for all four starboadside bilge alarms for audible. 46CFR182.530.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: Tested all visual indicators. All satisfactory.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 1 November 2016 Resolved
Update Emergency Instructions.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Verified the emergency instructions were updated.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 1 November 2016 Resolved
Show completion of CPR training for crew.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Verified the CPR training was conducted.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 November 2016 Resolved
Update Charts & Nav Rules.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Verified charts and Nav. Rules book were updated.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 November 2016 Resolved
Provide Complete Medical Kit.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Verified expired first aid kit medicine was replaced.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 1 November 2016 Resolved
Replace expired ring buoy light battery.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Verified battery was replaced.
Engineering › Bilge Water Management System › Interface Detector
Issued 1 November 2016 Resolved
Visual indicator was not installed at operating station.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 17 November 2016
Resolution: visual indicators were provided and tested to the satisfaction of the attending inspectors.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 August 2015 Resolved
Installed FireBoy-Xintex system is not functioning as designed. Machinery shut down during system test, but restarted in the normal position after a 3-5 sec delay due to unapproved modifications made to de-energize the fuel solenoid to keep it from burning up after shut down. System must be installed iaw manufacturer during drydock in November 2015.
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 28 December 2015
Resolution: Verified proper operation of both MDE's shutdowns and override system panels.
Engineering › Bilge Water Management System › Piping
Issued 3 August 2015 Resolved
Properly repair bilge piping system.
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Wasted piping renewed.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 3 August 2015 Resolved
Repair and permanently affix shore power receptacle.
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Shore power properly installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 August 2015 Resolved
Remove solid type wiring for galley icemaker and renew with approved marine grade wire.
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Proper marine grade wiring installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 August 2015 Resolved
Remove temporary flexible chord for aft stern flood lights and hard wire both galley and aft lighting circuits using approved method.
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Wiring properly installed.
Stability › Watertight Integrity › General
Issued 3 August 2015 Resolved
Properly seal electrical and fuel piping openings in engine room with appropriate fire resistant and watertight material.
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Electrical and fuel piping openings properly sealed.
Engineering › Fuel Oil Service System › Filter
Issued 3 August 2015 Resolved
Properly install marine grade fuel strainers for main diesel engines and generator.
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 3 September 2015
Resolution: O/O provided and installed marine grade fuel filters.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 3 August 2015 Resolved
Provide proper locking mechanism for sewage overboard valve.
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Sewage overboard valve properly secured.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 August 2015 Resolved
Repair exhaust leak on stbd main diesel engine exhaust piping.
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Exhaust piping repaired and tested.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 22 October 2014 Resolved
PROVIDE AND DISPLAY PHONE NUMBER FOR DRUG AND ALCOHOL HOTLINE.
Due 29 October 2014
Resolved 27 October 2014
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 October 2014 Resolved
PROVIDE UPDATED TIDES AND CURRENTS, COAST PILOT, AND LIGHTLIST.
Due 4 November 2014
Resolved 5 November 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 October 2014 Resolved
PROVIDE APPROVED (USCG) FIRST AID KIT
Due 4 November 2014
Resolved 5 November 2014
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 October 2014 Resolved
SECURE PROPERLY THE STBD AFT PASSENGER BENCH.
Condition: Improper/Lack of Maintenance
Due 29 October 2014
Resolved 27 October 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 October 2014 Resolved
PROPERLY REPLACE BRACKET FOR B-II FIRE EXTINGUISHER AT OPERATING STATION.
Condition: Improper/Lack of Maintenance
Due 29 October 2014
Resolved 29 October 2014
Electrical › Electrical Distribution System (service) › Fuse
Issued 22 October 2014 Resolved
PROVIDE/ INSTALL FUSE AT MAIN DISTRIBUTION PANEL FOR RADIO. (CITED 46CFR 183.10-20 (m))
Condition: Improper Installation
Due 29 October 2014
Resolved 29 October 2014
Engineering › Steering Gear System › Bracket/Clamp
Issued 22 October 2014 Resolved
INSTALL PROPER BRACKET FOR STBD HYDRAULIC STEERING HOSES. (CITED 46CFR182.40-1(a)(1))
Due 29 October 2014
Resolved 27 October 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 October 2014 Resolved
REPLACE WIRE CONNECTORS FOR HALOGEN LIGHTTS ON BOW AND ON STBD SIDE FIRE PUMP. (CITED 46CFR183.05-50(b))
Condition: Improper/Lack of Maintenance
Due 29 October 2014
Resolved 29 October 2014
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 October 2014 Resolved
REPLACE RIPPED LIFEJACKET (ADULT) (46CFR181.71)
Condition: Damaged By Earlier Event
Due 29 October 2014
Resolved 29 October 2014
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 October 2014 Resolved
PROVIDE EMERGENCY INSTRUCTIONS FOR MAN OVERBOARD AND FIRE AT OPERATING STATION OR OTHER CONSPICUOUS LOCATION. (CITED 46CFR185.25-1)
Due 29 October 2014
Resolved 29 October 2014
Construction/Loadline › Structures › Superstructure
Issued 22 October 2014 Resolved
REPAIR WOOD ROT IN STBD FWD ACCESS OVERHEAD. (CITED 46CFR176.25-40)
Due 20 November 2014
Resolved 5 November 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 22 October 2014 Resolved
ENSURE PROPER OPERATION OF MAST HEAD LIGHT. (CITED 46CFR183.420)
Due 29 October 2014
Resolved 27 October 2014
Fire Fighting › Fire Hoses › Material
Issued 4 December 2007 Resolved
Replace food grade fire hose with commercial grade garden hose in accordance with 46CFR181.320
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2007
Resolution: Hose replaced.
Fire Fighting › Fire Main › Material
Issued 4 December 2007 Resolved
Remove flexible hose from fire main. Replace with hard pipe. Metallic flex pipe may be used around fire pump for adjustments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2007
Resolution: Hard pipe installed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 December 2007 Resolved
Make permanent repairs to leak in port MDE exhaust cooling. Hose at MDE is leaking at coupling.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2007
Resolution: Leak secured.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 December 2007 Resolved
Make permanent repairs to hydraulic leak in steering, port side.
Action required: 705 - Other - as specified
Due 12 December 2007
Resolved 6 December 2007
Resolution: Leak secured.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 4 December 2007 Resolved
Make proper repairs to leaks in #3 injector on generator.
Action required: 705 - Other - as specified
Due 12 December 2007
Resolved 13 December 2007
Resolution: Injector repaired.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 4 December 2007 Resolved
Permanently mount sea strainers for both MDEs.
Action required: 705 - Other - as specified
Due 12 December 2007
Resolved 6 December 2007
Resolution: Sea strainers mounted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 December 2007 Resolved
Remove/splice/attach dead-end wires on stbd MDE sea strainer.
Action required: 705 - Other - as specified
Due 12 December 2007
Resolved 6 December 2007
Resolution: Sea strainers affixed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 December 2007 Resolved
Remove epoxy patch and make permanent repairs to exhaust cooling elbow on stbd MDE (inboard).
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 13 December 2007
Resolution: Elbow replaced.
Construction/Loadline › Penetrations › Pipe Flange
Issued 17 July 2007 Resolved
Replace thru hull fitting for sewage tank vent.
Action required: 705 - Other - as specified
Due 24 July 2007
Resolved 24 July 2007
Resolution: Thru hull fitting for sewage tank vent replaced
Construction/Loadline › Hull › Transverse Frame
Issued 16 July 2007 Resolved
Make proper repairs to hole,2nd transverse overhead,from bow, stbd side fore peak.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Resolution: Proper repairs made
Construction/Loadline › Hull › Side Shell
Issued 16 July 2007 Resolved
Make proper repairs to damaged FRP on exterior of port and stbd sponsons as marked.(01 stbd outboard, approx 04 stbd inbd,approx 04 port inbd.)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Resolution: Proper repairs made
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2007 Resolved
Make proper repairs to hole in decking/overhead in way of port side steering gear outboard aft corner.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Resolution: Proper repairs made
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2007 Resolved
Replace missing light fixture covers in port engine room in way of bilge pump and port stowage locker on main deck.(2 covers)
Condition: Unknown
Due 23 July 2007
Resolved 19 July 2007
Resolution: Proper electrical covers installed
Construction/Loadline › Structures › Deck Plating
Issued 16 July 2007 Resolved
Make proper repairs to broken cleat/deck port aft corner.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Resolution: Proper repairs made
Construction/Loadline › Structures › Deck Plating
Issued 16 July 2007 Resolved
Make proper repairs to water damaged overhead portside aft engine room.
Condition: Unknown
Due 23 July 2007
Resolved 19 July 2007
Resolution: Proper repairs made
Electrical › Electric Supply System (service) › Cable
Issued 16 July 2007 Resolved
Repair /Replace broken shoretie electrical cable in portside aft storage room.
Condition: Unknown
Due 23 July 2007
Resolved 19 July 2007
Resolution: Cable replaced
Construction/Loadline › Penetrations › Valve Flange
Issued 16 July 2007 Resolved
Prove proper operation of marine sanitation device overboard valves.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Resolution: Proper repairs made
Construction/Loadline › Penetrations › Valve Flange
Issued 16 July 2007 Resolved
Attach Electric bilge suction overboard check valves directly to through hull fittings. Double clamp hose.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2007
Resolution: Proper connections made
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 July 2007 Resolved
Replace wing nuts on batteries with correct hardware.
Condition: Unknown
Due 23 July 2007
Resolved 19 July 2007
Resolution: Proper electrical connections made
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 18 September 2006 Resolved
Cover on electrical box missing.
Action required: 705 - Other - as specified
Due 25 September 2006
Resolved 21 September 2006
Resolution: Cover was placed.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 September 2006 Resolved
Fan in storage area needs cover.
Action required: 705 - Other - as specified
Due 25 September 2006
Resolved 21 September 2006
Resolution: Cover was placed.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 September 2006 Resolved
Remove or redirect electric cable.
Action required: 705 - Other - as specified
Due 25 September 2006
Resolved 21 September 2006
Resolution: Cable was placed properly.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 September 2006 Resolved
Training logs missing.
Action required: 705 - Other - as specified
Due 25 September 2006
Resolved 21 September 2006
Resolution: corrected on the spot
Fire Fighting › Fire Pumps › Impeller
Issued 1 September 2005 Resolved
Prove proper operation of fire pump
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2005
Resolved 6 September 2005
Resolution: Vsl proved proper operation of fire pump.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2005 Resolved
Provide ring bouy float light.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2005
Resolved 6 September 2005
Resolution: Replacement of ring bouy float light has been provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 September 2005 Resolved
Provide covers for all overhead lighting fixtures.
Condition: Improper/Lack of Maintenance
Due 20 September 2005
Resolved 22 September 2005
Resolution: Cleared
Stability › Watertight Integrity › General
Issued 1 September 2005 Resolved
Install new watertight seals for port and stbd room hatches and generator room hatch.
Condition: Improper/Lack of Maintenance
Due 14 September 2005
Resolved 22 September 2005
Resolution: New seals have been installed and fit properly.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 1 September 2005 Resolved
Secure volt gauge and switch for generator.
Condition: Improper/Lack of Maintenance
Due 14 September 2005
Resolved 22 September 2005
Resolution: Volt guage has been properly secured.
Stability › Watertight Integrity › General
Issued 1 September 2005 Resolved
Properly seal piping through bulkhead of compartment 3 leading to compartment 4, port side.
Condition: Improper/Lack of Maintenance
Due 14 September 2005
Resolved 22 September 2005
Resolution: New packing has been installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2005 Resolved
Secure exposed wire in port collision bulkhead.
Due 20 September 2005
Resolved 22 September 2005
Resolution: Wire has been secured.
Stability › Incline Test › General
Issued 1 September 2005 Resolved
Remove all uneccessary stored items throughout vessel.
Due 20 September 2005
Resolved 22 September 2005
Resolution: Unneccesary stored items were being removed while MI was on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2005 Resolved
Secure all wiring as per the requirements of 46 CFR subchapter J.
Condition: Improper/Lack of Maintenance
Due 20 September 2005
Resolved 22 September 2005
Resolution: Great efforts have been made to secure wiring.
Documentation › Logs/Records › Logbook (official)
Issued 1 September 2005 Resolved
Provide training logbook seperate of maintenance log.
Due 20 September 2005
Resolved 22 September 2005
Resolution: Cleared
Stability › Weathertight Integrity › General
Issued 1 September 2005 Resolved
Provide quick closing valve for all submersable bilge pumps.
Due 9 September 2005
Resolved 22 September 2005
Resolution: New quick closing valves have been installed near bulkhead.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 1 September 2005 Resolved
Replace B-1 portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2005
Resolution: New B-1 extinguisher has been provided and installed on vessel.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 1 September 2005 Resolved
Secure leakage of both shaft seals.
Condition: Unknown
Due 14 September 2005
Resolved 22 September 2005
Resolution: Packing has been tightened and has minimal leak.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 September 2005 Resolved
Provide proof that master and crew are enrolled in a chemical testing program.
Due 14 September 2005
Resolved 22 September 2005
Resolution: Vsl has provided evidence of chemical testing program.
Documentation › Certificates/Documents › FCC SSL
Issued 1 September 2005 Resolved
Provide FCC Safety Certificate.
Due 20 September 2005
Resolved 22 September 2005
Resolution: Cleared
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2005 Resolved
Crop and renew port side bow corner where hull and deck connect. Area was found to be unusable due to extensive water deterioration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: Corner has been renewed.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2005 Resolved
Crop and renew starboard side bow corner where hull and deck connect. Area was found to be unusable due to extensive water deterioration and apparent damage as a result of possible dock side allision.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: Corner has been renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 13 July 2005 Resolved
Renew first 4, from bow, transverse deck beams and overhead decking. Deck beams and deck have sustained significant water damage and appear to be not structurally sound. Beams and compartment within appear to have had long term water leakage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2007
Resolution: First 4 transverse deck beams have been replaced.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2005 Resolved
Starboard side, renew decking until "good wood" is found over compartment #2. Significant long term water damage was found.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: New decking has been installed with teak plywood panels.
Construction/Loadline › Hull › Transverse Frame
Issued 13 July 2005 Resolved
Starboard side, compartment forward of marine sanitation device (MSD), renew middle 3 transverse deck beams and associated overhead decking. Significant long term water damage was found.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: Completed
Construction/Loadline › Hull › Transverse Frame
Issued 13 July 2005 Resolved
Starboard side, compartment containing marine sanitation device, renew transverse deck beam overhead MSD and associated overhead decking. Significant long term water damage was found.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: New section of deck beams have been installed
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2005 Resolved
Starboard side, renew decking of passenger entrance. Significant long term water damage was found.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: New decking using teak plywood panels have been installed
Construction/Loadline › Hull › Transverse Frame
Issued 13 July 2005 Resolved
Starboard side eng room aft, renew transverse deck beam. Significant long term water damage was found.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: New section of deck beam has been replaced.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2005 Resolved
Port side steering gear compartment, renew overhead decking. Significant long term water damage was found.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: New decking was installed.
Construction/Loadline › Hull › Hull Plating
Issued 13 July 2005 Resolved
Renew/reglass all marked areas of outer hull.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: Completed
Stability › Watertight Integrity › Weathertight Enclosure
Issued 13 July 2005 Resolved
Replace through hull fitting from aft port steering room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2005
Resolution: New through hull fitting installed.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2005 Resolved
Renew/replace stern shelf that holds the neon sign.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2005
Resolution: New bolts attached to shelf that holds sign. Appears to be stability.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 July 2005 Resolved
Secure all wiring and ensure dead wires are removed in galley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2005
Resolution: All wires have been secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 July 2005 Resolved
Replace stbd side position light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2005
Resolution: New position light installed and works properly.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 November 2004 Resolved
Replace 5 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 2 December 2004
Electrical › Electrical Distribution System (service)
Issued 25 November 2003 Resolved
Provide three outlet boxes LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2003
Resolved 10 December 2003
Electrical › Electrical Distribution System (service)
Issued 25 November 2003 Resolved
Secures electrical cables on generator room and STBD main diesel generator. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2003
Resolved 10 December 2003
Engineering › Fuel Oil Service System
Issued 25 November 2003 Resolved
Provide diesel fuel hose on port side main engine. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2003
Resolved 10 December 2003
Lifesaving › Buoyant Apparatus
Issued 25 November 2003 Resolved
provide black UV resistant line for life line and the water line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2003
Resolved 10 December 2003
Lifesaving › Lifejacket/PFD (Type III)
Issued 25 November 2003 Resolved
Provide neccesary retro tape for five (5) Lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2003
Resolved 10 December 2003
Construction/Loadline › Hull › Bottom Plating
Issued 8 July 2003 Resolved
Grind and repair all FRP blisters throughout the vessel.
Condition: Unknown
Due 11 July 2003
Resolved 8 July 2003
Construction/Loadline › Structures
Issued 8 July 2003 Resolved
Replace rotted wood at vessel's aft wood bulkhead, and port and starboard side wood bulkheads (multiple locations). LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 11 July 2003
Resolved 25 August 2003
Engineering › Reduction Gearing/Clutches › Bearing
Issued 8 July 2003 Resolved
Replace bearing on rudders (port/starboard).
Condition: Placed in Improper Service
Due 11 July 2003
Resolved 8 July 2003
Construction/Loadline › Hull › Hull Plating
Issued 8 July 2003 Resolved
replace all zinc anodes.
Condition: Placed in Improper Service
Due 11 July 2003
Resolved 8 July 2003
Electrical › Lighting (service)
Issued 8 July 2003 Resolved
Provide glass shield for the aft lights(glass broken) LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 14 July 2003
Resolved 10 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 8 July 2003 Resolved
Secure ladder for the first void starboard side vessel. LEGACY COMPONENT DESC: Hand Grab
Condition: Damaged By Earlier Event
Due 11 July 2003
Resolved 10 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 8 July 2003 Resolved
Provide support for the frame forward the ladder, first void starboard side. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Design Flaw
Due 11 July 2003
Resolved 25 August 2003
Construction/Loadline › Hull
Issued 8 July 2003 Resolved
Replace rotted wood in the frame forward the ladder in the way of the exterior hull,second void starboard side. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 11 July 2003
Resolved 25 August 2003
Construction/Loadline › Structures
Issued 8 July 2003 Resolved
Seal forward superstructure aluminum bulkhead, separated during the voyage from San Juan to Puerto Del Rey. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Placed in Improper Service
Due 11 July 2003
Resolved 25 August 2003
Construction/Loadline › Structures
Issued 8 July 2003 Resolved
Repair hole in top deck at the third void {battery room) starboard side, third frame from forward bulkhead. LEGACY COMPONENT DESC: Deck Plating
Condition: Damaged By Earlier Event
Due 11 July 2003
Resolved 10 July 2003
Pollution Prevention/Response › Prevention Equipment
Issued 8 July 2003 Resolved
Remove fuel oil and oily water spilled in the fuel tank at the generater room. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Condition: Improper/Lack of Maintenance
Due 11 July 2003
Resolved 10 July 2003
Operations/Management › Drills/Instruction
Issued 24 September 2002 Resolved
Log all drills monthly when practical, but not less than eery three months in accordance with 46 CFR 185.520 and 46 CFR 185.524. LEGACY COMPONENT DESC: Fire
Due 16 October 2002
Resolved 22 October 2002
Documentation › Certificates/Documents
Issued 24 September 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 16 October 2002
Resolved 22 October 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 September 2002 Resolved
Profice evidence that 50% of teh crew has received First Aid/CPR training.
Due 16 October 2002
Resolved 22 October 2002
Documentation › Manuals/Policy Documentation
Issued 24 September 2002 Resolved
Provide current training logbook IAW 46 CFR 185.420. LEGACY COMPONENT DESC: Training Manual (lifesaving)
Due 16 October 2002
Resolved 4 October 2002
Documentation › Logs/Records
Issued 24 September 2002 Resolved
Include passenger count with all voyages per 46 CFR 185.504. LEGACY COMPONENT DESC: Logbook (official)
Due 16 October 2002
Resolved 22 October 2002
Navigation › Piloting/Steering
Issued 24 September 2002 Resolved
Provide teh following navigation publications for San Juan Bay area (b through e could be supplement with a current Reeds Nautical Alminac): a. Current and corrected San Juan Bay chart. b. US Coast Pilot. c. Coast Guard Light List d. Tide Tables e. Tidal Current Tables LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 15 November 2002
Resolved 6 December 2002
Navigation › Piloting/Steering
Issued 24 September 2002 Resolved
Install light for magnetic compass IAW 46 CFR 184.402. LEGACY COMPONENT DESC: Magnetic Compass
Due 22 October 2002
Resolved 22 October 2002
Communications › Audible Communications
Issued 24 September 2002 Resolved
Procure a battery bulhorn IAW 46 CFR 176.802. LEGACY COMPONENT DESC: SPD (Other)
Due 16 October 2002
Resolved 22 October 2002
Construction/Loadline › Hull
Issued 24 September 2002 Resolved
Seal water leak on starboard side main deck to prevent the ingress of water into the hull in way of the second bulkhead. LEGACY COMPONENT DESC: Side Shell
Due 16 October 2002
Resolved 22 October 2002
Operations/Management › Drills/Instruction
Issued 24 September 2002 Resolved
Update the passenger safety orientatino to include all elements of 46 CFR 185.506. LEGACY COMPONENT DESC: Safety Orientation
Due 16 October 2002
Resolved 22 October 2002
Engineering › Sea-water System (primary cooling)
Issued 24 September 2002 Resolved
Replace engine exhaust flexible hoses on port and starboard engines with appropriate arrangement. Fax this office a repair proposal prior to installation for approval. LEGACY COMPONENT DESC: Piping
Due 16 October 2002
Resolved 22 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 24 September 2002 Resolved
Install mahcinery guards on port and starboard main engines IAW 46 CFR 177.960 and 46 CFR 177.35-15. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 16 October 2002
Resolved 22 October 2002
Communications › Alarms/Indicators
Issued 24 September 2002 Resolved
Repair/replace the foward port high bilge alarm float switch IAW 46 CFR 182.530. LEGACY COMPONENT DESC: Bilge Alarm
Due 16 October 2002
Resolved 22 October 2002
Electrical › Electrical Distribution System (service)
Issued 24 September 2002 Resolved
Install two blanks in switchboard panel in galley area. LEGACY COMPONENT DESC: Switchboard
Due 16 October 2002
Resolved 22 October 2002
Electrical › Electrical Distribution System (service)
Issued 24 September 2002 Resolved
Replace the wirining on the deck o fthe bridge with approved mareine wiring IAW 46 CFR 183.340 and configure it such that that it doesn't generate a tripping hazard. Fax the propsed arrangement to this office prior to installation. LEGACY COMPONENT DESC: Cable
Due 16 October 2002
Resolved 22 October 2002
Electrical › Lighting (emergency)
Issued 24 September 2002 Resolved
Repair/replace the forward port emergency light on the main deck. LEGACY COMPONENT DESC: Lighting Fixture
Due 16 October 2002
Resolved 22 October 2002
Navigation › Collision/Grounding Avoidance
Issued 24 September 2002 Resolved
Reconfigure teh stern light arrangement such that when traniting without passengers, the sign on the stern does not obstrcut any of the stern light's field of view. LEGACY COMPONENT DESC: Navigation Lights
Due 15 November 2002
Resolved 6 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 24 September 2002 Resolved
Install nonskid on wooden steps leading to upper deck to remove slip-hazard during rain.
Condition: Improper/Lack of Maintenance
Due 15 November 2002
Resolved 6 December 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 September 2002 Resolved
Install proper retaining clips on the pins that connect the throttle cables to each engine and remove the plastic tie wraps. LEGACY COMPONENT DESC: Governor
Condition: Improper Installation
Due 22 October 2002
Resolved 6 December 2002
Electrical › Lighting (service)
Issued 2 January 2002 Resolved
Numerous lightbulbs of the "decorative" lighting were missing creating a safety hazard common areas such as the upper deck. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 19 January 2002
Resolved 28 January 2002
Operations/Management › Drills/Instruction
Issued 2 January 2002 Resolved
Drills have not been logged. Instructed owner that MSO rep would attend vessel in approx. 2 months for a follow-up to view logbook to check for entries. LEGACY COMPONENT DESC: Fire
Condition: Improper/Lack of Maintenance
Due 19 February 2002
Resolved 28 January 2002
Operations/Management › Drug and Alcohol Testing
Issued 2 January 2002 Resolved
Enroll 1st mate into drug consortium no later than 26DEC01. Provide MSO with fax copy of enrolment at [phone withheld].
Due 26 January 2002
Resolved 26 January 2002
Resolution: Received fax of enrollment.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 2 January 2002 Resolved
Fax captain's license to MSO no later than 26DEC01.
Due 2 January 2002
Resolved 2 January 2002
Resolution: Captain came to MSO with origional copy of license. All Sat.
Electrical
Issued 28 June 2001 Resolved
Replace cable and wire supports with metal supports of spacing not more than 24 inches apart in accordance with 46 CFR 183.340(b)4.
Condition: Unknown
Due 3 October 2001
Resolved 3 October 2001
Documentation
Issued 23 January 2001 Resolved
Master License expired - 20 Dec 00
Condition: Unknown
Due 25 January 2001
Resolved 25 January 2001
Documentation
Issued 23 January 2001 Resolved
Vessel name is no on vessel other than in lights.
Condition: Unknown
Due 26 April 2001
Resolved 9 May 2001
Documentation
Issued 23 January 2001 Resolved
Hull identification number not permanently affixed, just painted on.
Condition: Unknown
Due 26 April 2001
Resolved 9 May 2001
Electrical
Issued 31 July 2000 Resolved
Repair shield for electrical section of generator no later than 27AUG00.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Construction/Loadline
Issued 31 July 2000 Resolved
Plug holes from missing rub rail in port collision space no later than 27AUG00.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Fire Fighting
Issued 31 July 2000 Resolved
Provide proff of annual service for fixed fire extinguishing system prior to carrying passengers.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Unknown
Issued 31 July 2000 Resolved
Provide CPR Certification for at least 50% of the crew no later than 27 AUG00.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Unknown
Issued 31 July 2000 Resolved
Provide FCC operators permit for each master onboard no later than 27AUG00.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Engineering
Issued 31 July 2000 Resolved
Renew flexible cooling hose from sea strainer to cooling pump on electricalgenerator prior to carrying passengers.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Construction/Loadline
Issued 31 July 2000 Resolved
Repair high bilge level alarm switch in stbd storage compartment prior to carrying passengers.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Engineering
Issued 31 July 2000 Resolved
Properly mount main engine sea strainer assemblies no later than 27AUG00.
Condition: Unknown
Due 27 August 2000
Resolved 1 August 2000
Construction/Loadline
Issued 31 July 2000 Resolved
Repair ALL high bilge level alarms prior to carrying passengers.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Fire Fighting
Issued 31 July 2000 Resolved
Repair engine shutdowns for fixed fire fighting system prior to carrying passengers.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Unknown
Issued 31 July 2000 Resolved
Provide evidence of a random chemical test program IAW 46CFR16 no later than 27AUG00.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Lifesaving
Issued 27 September 1999 Resolved
Prior to 30Sep99, properly label number of life preservers in each box.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 27 September 1999 Resolved
Prior to 30Sep99, properly provide retro reflective tape on ring life buoy.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 27 September 1999 Resolved
Prior to 30Sep99, provide donning instructions for all life preserver box's.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 27 September 1999 Resolved
Prior to 30Sep99, demonstrate the proper operation of the fixed fire extinguishing system.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 27 September 1999 Resolved
Prior to 30Sep99, remove locking device off of life preserver box's.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 27 September 1999 Resolved
Prior to 30Sep99, have all portable fire extinguishers inspected.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Construction/Loadline
Issued 15 April 1999 Resolved
PROVIDE PROPER REPAIR TO PLATFORM AND SUPPORTS.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Documentation
Issued 15 April 1999 Resolved
PROVIDE FCC SAFETY RADIOTELEPHONY CERTIFICATE, FCC STATION LICENSE AND FCC OPERATORS PERMIT.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Construction/Loadline
Issued 15 April 1999 Resolved
PROVIDE PORPER FRP REPAIRS TO BLISTERS AND PEELING PREVIOUS REPAIRS IN WAY OF CHALKED AREAS.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Engineering
Issued 15 April 1999 Resolved
RENEW STBD WATERLUBE BEARING.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Engineering
Issued 15 April 1999 Resolved
RENEW OR REPLACE PORT WHEEL.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Construction/Loadline
Issued 20 October 1998 Resolved
PRIOR TO 22JAN99, PROVIDE A BILGE PUMPING SYSTEM IAW 46CFR182.500.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Construction/Loadline
Issued 20 October 1998 Resolved
PRIOR TO 22JAN99, PROVIDE 6 INCH SILLS UNDER ALL BOARDING PORTS.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Documentation
Issued 25 September 1997 Resolved
PROVIDE VALID FCC SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Lifesaving
Issued 25 September 1997 Resolved
PROVIDE VESSEL SPECIFIC EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Electrical
Issued 25 September 1997 Resolved
PROVIDE AND POST RADIO EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Lifesaving
Issued 25 September 1997 Resolved
PROVIDE RETROREFLECTIVE TAPE FOR RING BUOYS.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Construction/Loadline
Issued 25 September 1997 Resolved
SEAL ALL PENETRATIONS IN BULKHEADS TO MAKE WATERTIGHT.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Engineering
Issued 25 September 1997 Resolved
PROVIDE DOUBLE CLAMPS FOR MACHINERY CONNECTIONS AND THROUGH HULL FITTINGS.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Construction/Loadline
Issued 25 September 1997 Resolved
SEAL ALL SCREW HOLES IN HULL.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Lifesaving
Issued 25 September 1997 Resolved
PROVIDE WRITTEN SAFETY ORIENTATION FOR PASSENGERS.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Navigation
Issued 25 September 1997 Resolved
PROVIDE VALID NAVIGATION CHARTS AND PUBLICATIONS.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Documentation
Issued 25 September 1997 Resolved
PROVIDE VALID FCC RADIO OPERATORS PERMIT.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Fire Fighting
Issued 5 September 1996 Resolved
SERVICE THE B-I FIRE EXT. AT HELM, AND THE B-II STDB HULL, AMIDSHIPS._x001C_ TO BE COMPLETED BEFORE OPS WITH PASSENGERS.
Condition: Unknown
Due 12 September 1996
Resolved 7 September 1996
Electrical
Issued 5 September 1996 Resolved
SECURE ALL LOOSE LIGHT FIXTURES.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
REMOVE ALL UN-APPROVED WIRING & LIGHT FIXTURES. SUBMIT PLANS TO MSO FOR APPROVAL TO HARD WIRE ALL ELE. ITEMS. REMOVE ALL OUTLET MULTIPLIERS, AND EXTENSION CORDS FROM VESSEL.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
PROVIDE ELE. DIAGRAM SHOWING LOAD ANALYSIS. HARD WIRE ALL ELE. ITEMS TO JUNCTION BOSESS. PROVIDE OVERLOAD PROTECTION. SUBMIT PLANS TO CORRECT. 30 DAYS TO BE COMPLETED, INCLUDING PLAN REVIEW.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Electrical
Issued 5 September 1996 Resolved
PROVIDE LIGHT GUARDS ON ALL EXPOSED BULBS. REPLACE FIXTURES AS NEEDED TO CORRECT.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Engineering
Issued 25 August 1996 Resolved
Prove proper operation of port main engine in the presence of a CG Marine Inspector. Engine lost oil during operation due to damaged o-ring on oil filter.
Condition: Unknown
Due 25 August 1996
Resolved 25 August 1996
Lifesaving
Issued 12 September 1995 Resolved
Label child's life preserver storage.
Condition: Unknown
Due 17 September 1995
Resolved 17 September 1995
Fire Fighting
Issued 12 September 1995 Resolved
Provide firehose nozzle IAW 46 CFR 181.15-10.
Condition: Unknown
Due 17 September 1995
Resolved 17 September 1995
Electrical
Issued 12 September 1995 Resolved
Provide cover for electical outlet at steering station.
Condition: Unknown
Due 17 September 1995
Resolved 17 September 1995
Documentation
Issued 12 September 1995 Resolved
Provide current copy of 46 CFR parts 175, subchapter T.
Condition: Unknown
Due 17 September 1995
Resolved 17 September 1995
Lifesaving
Issued 12 September 1995 Resolved
Provide approved flares IAW 46 CFR 180.35-1.
Condition: Unknown
Due 17 September 1995
Resolved 17 September 1995
Documentation
Issued 22 September 1994 Resolved
Provide documentation of a drug testing program conducted in accordance with 46 CFR Part 16.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Documentation
Issued 22 September 1994 Resolved
Provide Certificate of Documentation showing new vessel owner/operator.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Navigation
Issued 22 February 1993 Resolved
Properly install mounting brackets on sidelights.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Accommodation/Occupational Safety
Issued 22 February 1993 Resolved
Pump out sewage tank.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Construction/Loadline
Issued 22 February 1993 Resolved
Install metallic cap on unused sewage overboard valve.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Documentation
Issued 22 February 1993 Resolved
Provide copy of FCC certificate.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Electrical
Issued 8 February 1992 Resolved
PROVIDE EMERGENCY LIGHTING FOR VESSEL IN THE FORM OF TWO HAND HELD FLASHLIGHTS.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Engineering
Issued 8 February 1992 Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM. SUCH A WARNING SHALL BE VISIBLE OR AUDIBLE AT THE ENGINE OPERATING STATION.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Accommodation/Occupational Safety
Issued 8 February 1992 Resolved
INSTALL HAND RAILS ON STERN OF VESSEL ACCESSIBLE TO CREW.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Lifesaving
Issued 8 February 1992 Resolved
PROVIDE ONE ADDITIONAL LIFE PRESERVER. UNTIL ADDITIONAL LIFE PRESERVERS PROVIDED, TOTAL PERSONS ALLOWED IS DECREASED TO 149.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Lifesaving
Issued 8 February 1992 Resolved
PROVIDE 18 FT OF LINE TO WATERLIGHTS THAT ATTACH TO BUOYANT APPARATUS.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Lifesaving
Issued 8 February 1992 Resolved
INSTALL 60 FEET OF LINE TO RING BUOYS.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Accommodation/Occupational Safety
Issued 8 February 1992 Resolved
REPAIR/REPLACE MSD PUMP.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Accommodation/Occupational Safety
Issued 8 February 1992 Resolved
PIPE BATHROOM TOILET DRAINS TO MSD TANK.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Engineering
Issued 8 February 1992 Resolved
PROVE OPERATION OF GENERATOR EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Navigation
Issued 8 February 1992 Resolved
PROVIDE APPROPRIATE CHARTS AND NAUTICAL PUBLICATIONS FOR OPERATING AREA IN ACCORDANCE WITH 46 CFR 185.20-25 AND 33 CFR 164.33.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Documentation
Issued 8 February 1992 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH 46 CFR PART 16, CHEMICAL TESTING OF EMPLOYEES.
Condition: Unknown
Due 8 March 1992
Resolved 6 March 1992
Lifesaving
Issued 8 February 1992 Resolved
ENSURE ALL BUOYANT APPARATUS PENDANTS ARE 12 FEET LONG AND ARE NOT SECURED BY MORE THAN TWO TURNS OF LIGHT TWINE.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Deck/Cargo
Issued 8 February 1992 Resolved
PROVIDE AT LEAST 270 FEET OF LINE FOR ANCHOR.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Accommodation/Occupational Safety
Issued 8 February 1992 Resolved
PROVIDE LOCKING DEVICE FOR MSD OVERBOARD DISCHARGE VALVE ON STARBOARD SIDE OF VESSEL.
Condition: Unknown
Due 8 February 1992
Resolved 8 February 1992
Construction/Loadline
Issued 14 May 1991 Resolved
MARK VESSELS STERN WITH EITHER HOMEPORT OR HAILING PORT IN ACCORDANCE WITH 46CFR PARTS 67 AND 68._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Accommodation/Occupational Safety
Issued 14 May 1991 Resolved
PROVIDE MEANS TO LOCK SEWAGE DISCHARGE VALVES IN THE LOCKED POSITION
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Accommodation/Occupational Safety
Issued 14 May 1991 Resolved
PROVIDE MEANS TO PROPERLY SECURE CO2 BOTTLES FOR SOFT DRINKS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Electrical
Issued 14 May 1991 Resolved
REMOVE EXISTING NON U/L APPROVED FOR MARINE USE FUEL FILTER FOR GENERATOR AND INSTALL SUITABLE MARINE TYPE STRAINER/FILTER IN ACCORDANCE WITH 46CFR 182.20-40(B)(5)
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Documentation
Issued 14 May 1991 Resolved
PROVIDE DOCUMENTATION FOR VESSELS OWNER ADDRESS TO DETERMINE PROPER HOMEPORT_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Lifesaving
Issued 14 May 1991 Resolved
CONSPICUOUSLY MARK RING BUOY WITH VESSEL'S NAME_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1991
Resolved 14 May 1991
Engineering
Issued 27 August 1990 Resolved
REPAIR DAMAGED STBD SKEG AND PROPELLER.
Condition: Unknown
Due 27 August 1990
Resolved 27 August 1990
Electrical
Issued 27 August 1990 Resolved
REMOVE NON APPROVED ELECTRICAL INSTALLATIONS CONSISTING OF ADDITIONAL CONVENIENCE RECEPTICALS BEING FED FROM ENGINEROOM OUTLETS.
Condition: Unknown
Due 27 August 1990
Resolved 27 August 1990
Engineering
Issued 20 November 1989 Resolved
INSTALL SHUTOFF VALVE IN THE FUEL OIL SUPPLY LINE AT THE STBD FUEL TANK.
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Engineering
Issued 20 November 1989 Resolved
INSTALL REMOTE FUEL SHUTOFFS ON THE FUEL SUPPLY LINES (PORT MN, STBD MN & GEN.) VALVES AT THE TANK.
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Documentation
Issued 25 August 1989 Resolved
CREDIT DRYDOCK DUE 25FEB91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Unknown
Issued 30 November 1988 Resolved
BUILDER, CORINTHIAN YACHTS INC IS TO SUBMIT CALCULATIONS CONCERNING STABILITY OF THE VESSEL DUE TO WEIGHT CHANGES DIFFERENT FROM ORIGINAL HULL 65-5. UNTIL THESE CALCULATIONS ARE PROVIDED, THE TOTAL NUMBER OF PASSENGERSIS REDUCED TO 100 (NO MORE THAN 50 ARE PERMITTED ON THE UPPER DECK)
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Accommodation/Occupational Safety
Issued 30 November 1988 Resolved
INSTALL SAFETY CHAIN AND WARNING SIGN AT AT DOOR PRIOR TO CARRYING PASSENGER.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Documentation
Issued 30 November 1988 Resolved
OBTAIN AND MAINTAIN ON BOARD AN FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Documentation
Issued 30 November 1988 Resolved
NEXT DRYDOCK DUE 30MAY90.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Accommodation/Occupational Safety
Issued 30 November 1988 Resolved
INSTALL OUTSIDE GRAB RAIL FROM P&S SIDE DOORS TO AFT CLEATS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988

Casualty record · 1

20 September 2017Routine · role: Involved in a Marine Casualty · activity 6290939
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CRAZY CLAM (2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.