MAURY USCG vessel records Sign in
← All vessels

NOBLE STAR

NOBLE STAR is a 1977 freight ship. The Coast Guard has recorded 133 inspections since 1984, most recently in October 2015, along with 121 deficiencies, 7 operational controls and 6 casualty investigations between 2007 and 2012.

Records from 1984 to 2015. Most recent: inspection, 8 October 2015.

Built
1977
Last inspected
8 October 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7529914 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DELETE 123
320289
Flag
UNITED STATES
368367000 (licence lapsed)
Maury page id
psix-320289

Inspections, by type

…with no type recorded63
Years with a record 28 calendar years (1984–2015)
The 133 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11366 - Regulatory (Subpart C or D), Net Ton
9589 - Convention (Subpart B), Net Ton
7116 - Dual (D), Net Ton
15918 - Regulatory (Subpart C or D), Gross Ton
16840 - Convention (Subpart B), Gross Ton
9787 - Dual (D), Gross Ton
8380 - Displacement, Ton
24400 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KRPPMMSI 368367000 · cancelled · compulsorily equipped · granted 26 November 2008, cancelled 19 November 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAIRO Industrial Vessel · MISLE 55558 · 12 March 2001 · activity 178688PACIFIC DAWN Towing Vessel · MISLE 129465 · 12 March 2001 · activity 178688

Inspection history · 133

8 October 2015 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5738252
11 July 2012 ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4466310
5 July 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4364664
25 February 2012 COE-Offshore
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4246453
18 February 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4248756
5 January 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4222435
14 December 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4205362
13 September 2011 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4144898
7 September 2011 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4138773
1 September 2011 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4133260
31 August 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4132870
25 August 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4127053
23 August 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4133666
24 February 2011 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3947862
24 February 2011 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3951791
7 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3903995
12 February 2010 Damage Survey
Physical examination · Activities Europe · Activity 3679138
1 February 2010 Type not recorded
No type recorded · Activities Europe · Activity 3714905
23 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3654865
29 July 2009 ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3549969
18 July 2008 MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3336978
26 May 2008 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3220937
20 November 2007 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3127129
21 May 2007 In-Service Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2935806
18 July 2006 Examination of Repairs · ACP COI Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2716504
6 June 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2672216
18 September 2005 ACP Annual Oversight
Administrative · Activities Europe · Activity 2486833
26 January 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2281264
22 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2246230
26 June 2004 MTSA/ISPS Verification · ACP Periodic Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2115853
1 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1957218
2 June 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1807606
23 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1799816
21 May 2003 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1802447
19 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1807543
16 March 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1758453
13 October 2002 Type not recorded
No type recorded · Activities Europe · Activity 2097589
24 June 2002 ACP COI Oversight
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1635858
16 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486687
8 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484577
8 August 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1068943
11 July 2001 COI Inspection
Physical examination · Activities Europe · Activity 1379529
12 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 178688
12 March 2001 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382158
8 December 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 435283
8 December 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 813631
22 April 1999 Type not recorded
No type recorded · Activities Europe · Activity 1360941
12 December 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 807282
16 July 1998 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 796485
25 April 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 532631
19 December 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 411477
7 December 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 215830
18 December 1996 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1094340
13 November 1996 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1176739
1 October 1996 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 833512
26 September 1996 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1141459
18 September 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 516939
28 August 1996 Hull Examination
Physical examination · Activities Europe · Activity 1374727
9 July 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1355875
31 May 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1383263
9 May 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1083304
22 April 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1081685
4 March 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459212
27 October 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 474595
5 September 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 877879
22 August 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 440486
15 May 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1238257
2 April 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 446870
23 March 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828489
21 February 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158536
20 January 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845248
20 September 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 163452
20 September 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 511294
11 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 28680
11 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 523798
14 July 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 867435
29 June 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 535800
25 May 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1181863
19 April 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859639
14 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 129991
12 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 481313
9 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 667496
8 February 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856399
22 January 1994 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856398
15 October 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 175350
9 October 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 361352
8 October 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 450931
10 June 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1150437
2 June 1993 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 842010
28 May 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 647179
27 May 1993 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 834834
8 May 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 478638
4 May 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 48647
25 March 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 839553
12 March 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1151983
2 February 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834235
18 May 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948116
18 May 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948768
14 February 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315339
30 January 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319346
29 January 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1011712
27 January 1992 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384952
16 December 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264522
12 December 1991 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 444955
3 December 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1259969
29 October 1991 Deficiency Check · Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 940610
12 June 1991 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1244982
11 June 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 453491
30 March 1991 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1226156
26 March 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 449387
8 February 1991 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1215724
5 February 1991 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1303553
9 November 1990 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 458007
31 May 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 919068
14 March 1990 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 912878
4 December 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1225865
16 June 1989 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1034479
2 June 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342702
31 May 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1042417
26 May 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1344094
17 May 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1042453
3 May 1989 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1212058
12 April 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 895637
10 March 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 964999
16 February 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 452842
22 January 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 506928
18 January 1989 Reflagging & Initial Certification · Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1203498
13 March 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 321942
13 January 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1324428
2 August 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 478878
29 July 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 310463
30 July 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 303346
10 July 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 473531

Deficiency record · 121

Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 11 July 2012 Resolved
Install proper rated safety relief valve on auxiliary boiler. Test to satisfaction of ACP class society (ABS).
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2012
Resolved 17 July 2012
Resolution: Examined and tested to satisfaction of class (ABS) per item no. T-531 in ABS Statutory Survey Report No. HS2173864 dated 09JUL2012.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 July 2012 Resolved
Repair and prove proper operation of installed oily water separator to satisfaction of ACP class society.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2012
Resolved 17 July 2012
Resolution: Suction filter casing was replaced with new one; unit examined and tested to satisfaction of class (ABS) per item no. T-532 in ABS Statutory Survey Report No. HS2173864 dated 09JUL2012.
Accommodation/Occupational Safety › Ventilation › General
Issued 11 July 2012 Resolved
Repair vent damper to Emergency Generator Space and reinstall missing dogs to closure device.
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 17 July 2012
Resolution: Examined and tested to satisfaction of class (ABS) per item no. T-533 in ABS Statutory Survey Report No. HS2173864 dated 09JUL2012.
Lifesaving › Lifeboat › Hull
Issued 11 July 2012 Resolved
Locate and properly repair source of leak on #2 lifeboat. Test to satisfaction of ACP class society prior to departure from the port of Houston.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2012
Resolved 17 July 2012
Resolution: Leak was located by fitting the aft plug into its place. Examined and tested to satisfaction of class (ABS) per item no. T-536 in ABS Statutory Survey Report No. HS2173864 dated 09JUL2012.
Electrical › Electric Generation Source (service) › Generator
Issued 11 July 2012 Resolved
Repair oil leak on center S/S generator.
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 17 July 2012
Resolution: Pre tube oil pressure sensor line "leak" was repaired, examined and tested to satisfaction of class (ABS) per item no. T-534 in ABS Statutory Survey Report No. HS2173864 dated 09JUL2012.
Engineering › Compressed Air System (start air) › Valve
Issued 11 July 2012 Resolved
Install proper rated/sealed safety relief valves on air receivers.
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 17 July 2012
Resolution: All air receivers (2x start, service, emerg., start air) were overhauled/tested and sealed at the proper rating to satisfaction of attending class (ABS) surveyor. (See item no. T-535 in ABS Statutory Survey Report No. HS2173864 dated 09JUL2012.)
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2009 Resolved
Loose/dead end wires present in main stair tower "B" deck. Remove or properly terminate dead end wires.
Action required: 705 - Other - as specified
Resolved 31 July 2009
Resolution: Wires were removed.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 29 July 2009 Resolved
Missing/broken wire supports along stbd side main deck at gangway. Install supports where supports are broken.
Action required: 705 - Other - as specified
Resolved 28 September 2009
Fire Fighting › Fire Hydrants › Condition
Issued 29 July 2009 Resolved
Fire hoses not rigged for service and missing spanner wrenches. Place spanners at all hydrants, and rig nozzles to hoses.
Action required: 705 - Other - as specified
Resolved 31 July 2009
Resolution: All fire stations were put back into compliance.
Construction/Loadline › Structures › Door
Issued 29 July 2009 Resolved
Aft entry to engine room, both port and stbd passageway entrances, bos'n hold, cargo deck #4 stbd, not water/weather tight. Doors did not operate properly and light was observed through the knife edge/gasket seal. #4 cargo hold port access door missing 3 of 6 striker plates. Door not water tight. All doors located on main deck. Various other doors on main deck in poor repair. Repair all doors
Action required: 705 - Other - as specified
Resolved 31 July 2009
Resolution: All dogs were properly worked and new gasket materials in place. Welders put in place new striker plates where needed. All doors were chalk tested and accepted as being satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 July 2009 Resolved
Repair broken deck rail, mid deck port side, fwd of main diesel engine.
Action required: 705 - Other - as specified
Resolved 31 July 2009
Resolution: Rails were rewelded.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 July 2009 Resolved
Repair broken deck rail port side bridge deck, just aft of bridge wing.
Action required: 705 - Other - as specified
Resolved 31 July 2009
Resolution: Rail was rewelded.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 July 2009 Resolved
Fire screen doors on "B" deck stair tower did not close and latch properly. Adjust doors for proper operation.
Action required: 705 - Other - as specified
Resolved 28 September 2009
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 July 2009 Resolved
Remove hazmat from fidley ventilation space. Remove oil soaked rags from fidley ventilation space.
Action required: 705 - Other - as specified
Resolved 31 July 2009
Resolution: Space was cleaned and made safe.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 July 2009 Resolved
Repair hanging light fixture port side of bridge deck.
Action required: 705 - Other - as specified
Resolved 28 September 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 29 July 2009 Resolved
Repair light in fidley ventilation space, port side bridge deck.
Action required: 705 - Other - as specified
Resolved 28 September 2009
Fire Fighting › Fire Hydrants › Condition
Issued 18 September 2005 Resolved
RENEW/REPAIR THREADS ON FIRE STATION 29 TO ENSURE FIRE HOSE CAN BE PROPERLY ATTACHED.
Due 18 November 2005
Resolved 26 September 2005
Resolution: RECEIVED EMAIL FROM THE MASTER ATTESTING THAT THE REPAIRS WERE MADE.
Lifesaving
Issued 11 July 2001 Resolved
CONDUCT FIRE AND BOAT DRILL FOR USCG AT NEXT U.S. PORT. RESOLVE PROBLEM WITH SPEED ON THE PORT BOAT WHICH CURRENTLY MAKES APPROX. 3 KNOTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Documentation
Issued 11 July 2001 Resolved
PROVIDE FAXED COPY OF THE FOLLOWING ABS ISSUED DOCUMENTS PRIOR TO SAILING: SEC, SEC SUPP, SCC, IOPP, ILL, ANNUAL CARGO SHIP SURVEY CERTIFICATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 July 2001
Resolved 7 August 2001
Engineering
Issued 31 May 1996 Resolved
Repair HFO viscosity meter and temperature regulator.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Construction/Loadline
Issued 31 May 1996 Resolved
Install remotely controlled valve control for emergency bilge suction valve.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Engineering
Issued 31 May 1996 Resolved
Provide copies of maintenance schedules and daily checklist.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Engineering
Issued 4 March 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Documentation
Issued 4 March 1996 Resolved
PROVIDE EVIDENCE THAT VSL OPERATOR HAS AN EMPLOYEE ASSISTANCE PROGRAM IN ACCORDANCE WITH 46 CFR PART 16.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Engineering
Issued 21 February 1995 Resolved
CONDUCT THE FOLLOWING MAIN ENGINE TESTS WHILE UNDER WAY: A) LOW OIL ALARM, B) LOW LUBE OIL TRIP, C) HIGH TEMP SLOWDOWN, D) OVER SPEED TRIP, E) WRONG DIRECTION ALARM. RESULTS OF ABOVE TESTS SHALL BE SENT IN WRITING, SIGNED BY THE CHIEF ENGINEER, TO THE [name withheld], INSPECTION DIVISION.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Electrical
Issued 20 January 1995 Resolved
IN PIPE TUNNEL, REPLACE GLOBES AND GUARDS AS NEEDED.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Electrical
Issued 20 January 1995 Resolved
REPLACE WASTED JUNCTION BOX IN 3A/3B CABLE PEDESTAL.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Electrical
Issued 20 January 1995 Resolved
IN "STOLKEN HOUSE" MG ROOM, REATTACH DOOR/FRONT PLATE FOR FUSE BOX.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Construction/Loadline
Issued 20 January 1995 Resolved
AT MAIN DECK HATCH C/L VOID,JUST AFT OF CARGO HOLD 4 IWO CRANE 3,AT STBD 3-STEP LADDER,C/R THE FOLLOWING:VOID OUTER BLKHD AT THE PEDESTAL PLATFORM IWOAN EXISTING CRACK.THE INSERT SHALL BE 6" UP FROM THE DECK OF THE PEDESTAL PLATFORM,EXTEND 6" FWD OF VERTICAL EDGE AND EXTEND 12" DOWN.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Unknown
Issued 20 January 1995 Resolved
PROVIDE COVERS OR REPLACE LIGHTING FIXTURES IN STEVEDORE ROOMS ON MAIN DECKPORT SIDE.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Lifesaving
Issued 20 January 1995 Resolved
PROVIDE PROOF OF HYDROSTATIC TEST FOR 2 SCBA BOTTLES IN DC LOCKER.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Fire Fighting
Issued 20 January 1995 Resolved
REPAIR DAMAGED FIRE DOOR LATCHES IN WAY OF BOTH FORWARD MACHINERY SPACE ENTRANCES AT THE "A" DECK LEVEL.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Lifesaving
Issued 20 January 1995 Resolved
MAKE PROPER PERMANENT REPAIRS TO PORT MOTOR LIFEBOAT ENGINE BOX.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Lifesaving
Issued 20 January 1995 Resolved
PROVIDE INSTRUCTION/WARNING PLACARD FOR PORT BOAT RELEASE LEVER.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Lifesaving
Issued 20 January 1995 Resolved
RE-ATTACH ALARM BELL TO GUNWHALE ON FOC'S'LE.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Documentation
Issued 20 January 1995 Resolved
PROVIDE PROOF OF ABS CARGO GEAR CERTIFICATION.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Accommodation/Occupational Safety
Issued 20 January 1995 Resolved
REPLACE NYLON/POLY LIFELINES WITH CHAIN ON P AND S BOAT DECKS IWO LIFERAFT STATIONS.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Electrical
Issued 20 January 1995 Resolved
REATTACH GROUNDING STRAP FOR STBD LIFEBOAT WINCH.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Engineering
Issued 20 January 1995 Resolved
CONDUCT THE FOLLOWING MAIN ENGINE TESTS WHILE UNDERWAY: A)LOW LUBE OIL ALARM,B)LOW LUBE OIL TRIP,C)HIGH TEMP SLOW DOWN,D)OVER SPEED TRIP,E)WRONG DIRECTION ALARM. RESULTS OF ABOVE TESTS SHALL BE SENT IN WRITING, SIGNED BY THE CHIEF ENGINEER, TO THE [name withheld], INSPECTIONS DIVISION.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Engineering
Issued 19 April 1994 Resolved
PROVE PROPER OPERATION OF NEW OWS.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Electrical
Issued 19 April 1994 Resolved
PROVE PROPER OPERATION OF OVERSPEEDS ON S/S GENERATORS #1, 2, & 3.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Engineering
Issued 19 April 1994 Resolved
PROVE PROPER OPERATION OF RELIEF VALVES ON THE MAIN AIR BOTTLE 1, MAIN AIR BOTTLE 2 AND SHIP SERVICE AIR. VALVES LEAK.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Electrical
Issued 27 May 1993 Resolved
REMOVE ALL SO TYPE ELECTRICAL CABLE ON NEW BLOWER INSTALLATION AN INSTALL APPROVED WIRING, PRIOR TO LOADING CARGO.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Construction/Loadline
Issued 27 May 1993 Resolved
MAKE OPERATIONAL AND TEST BILGE SUCTION VALVES FOR #1 CARGO HOLD, PRIOR TO LOADING CARGO.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Electrical
Issued 27 May 1993 Resolved
SUBMIT PLANS TO THE COAST GUARD MARINE SAFETY CENTER FOR REVIEW ON THE NEW DUCTING AND ELECTRICAL INSTALLATION FOR THE EMERGENCY GENERATOR._x001C_
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Electrical
Issued 27 May 1993 Resolved
PROVE OPERATION OF EMERGENCY GENERATOR HIGH TEMPERATURE ALARM PRIOR TO LOADING CARGO.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Documentation
Issued 2 February 1993 Resolved
PROVIDE A COPY OF A CURRENT VALID ABS ISSUED CARGO GEAR CERTIFICATE FOR VESSELS BOOMS, CRANES AND DERRICKS TO THE [name withheld] OR COMPLY WITH THE REQUIREMENTS OF 46 CFR 91.37-5.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Fire Fighting
Issued 2 February 1993 Resolved
HYDRO TEST SCBA OXYGEN BOTTLE NO 114970.
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Engineering
Issued 2 February 1993 Resolved
TEST WASTE HEAT BOILER RELIEF VALVE DURING NEXT UNDERWAY PERIOD. RECORD POPPING AND SEATING PRESSURES IN OFFICIAL ENGINEERING LOG BOOK AND FAX COPIES OF INFORMATION, LOG BOOK ENTRY, AND CG-835 FORM TO [name withheld] US PORT OR COAST GUARD INSP HAVE SAFETY VALVE SEALED BY USCG INSPECTOR.
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Electrical
Issued 2 February 1993 Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY GENERATOR COOLING AIR EXHAUST DUCT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Engineering
Issued 2 February 1993 Resolved
REPAIR OR REPLACE STEAM PIPE LOCATED ABOVE LADDER BY OIL FIRED AUX BOILER. REPAIR/REPLACEMENT TO BE DONE IN ACCORDANCE WITH ASME TO COAST GUARDS SATISFACTION._x001C_ _x001C_
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Fire Fighting
Issued 2 February 1993 Resolved
IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PROVE THE PROPER OPERATION OF ALL VESSEL'S FIRE DETECTION SYSTEMS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Lifesaving
Issued 2 February 1993 Resolved
PROVIDE AN AUDIBLE ALARM AS REQUIRED BY 46 CFR 113.45-5(C) ON VESSEL'S BRIDGE OR ENGINE CONTROL ROOM FOR THE VESSEL'S REFRIGERATION SPACES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Lifesaving
Issued 2 February 1993 Resolved
REPAIR SHIP SERVICE AIR RECEIVER. DEFECT NOTED INSIDE ON LEFT SIDE WHEN LOOKING IN THROUGH ACCESS COVER. UNTIL REPAIRS MADE MAWP LIMITED TO 90 PSI.
Condition: Unknown
Due 19 April 1993
Resolved 21 June 1993
Deck/Cargo
Issued 2 February 1993 Resolved
PROVE THE PROPER OPERATION OF ALL CARGO HOLDS BILGE ALARMS AND BILGE SYSTEMIN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Documentation
Issued 29 January 1992 Resolved
PRIOR TO DEPARTURE OF SAN FRANCISCO BAY, CA. PROVIDE A COPY OF VESSEL'S CERTIFICATE OF FINANCIAL RESPONSIBILITY SHOWING COMPLIANCE WITH THE LAW.
Condition: Unknown
Due 31 January 1992
Resolved 31 January 1992
Construction/Loadline
Issued 27 January 1992 Resolved
MAKE THE TEMPORARY REPAIR TO THE HIGH SEACHEST STARBOARD SIDE IN ACCORDANCEWITH MARINE SAFETY OFFICE SAN FRANCISCO BAY LETTER OF 16 DEC 1991 (SUBJ: NOBLE STAR, O.N. 941410, PROPOSED REPAIRS TO HIGH SEACHEST IN ENGINEROOM).
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Construction/Loadline
Issued 27 January 1992 Resolved
PROVIDE A COPY OF UNDERWATER MARKING PLAN FROM THE 1989 DRYDOCKING AS REQUIRED BY MARINE SAFETY OFFICE SAN FRANCISCO BAY LETTER OF 02 JAN 1992 (SUBJ: UNDERWATER SURVEY PROGRAM).
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 27 January 1992 Resolved
REPAIR AS ORIGINAL PORT ANCHOR WINDLASS HYDRAULIC RETURN LINE.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 27 January 1992 Resolved
(CONT. 4A) TO INSPECT AND MAKE AN ENTRY IN THE SHIPS LOG AS TO ITS CONDITION. AT LEAST EVERY 60 DAYS A COPY OF SHIPS LOGS CONTAINING FRACTURE CONDITION ENTRIES SHALL BE SENT TO MSO SAN FRANCISCO BAY UNTIL FRACTURED REPAIRED OR NEXT DRYDOCKING, WHICH EVER OCCURS FIRST.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 27 January 1992 Resolved
MAKE PERMANENT REPAIR TO FRACTURED PORT LONGITUDINAL DECK BEAM IN NO. 3 CARGO HOLD AT THE FIRST AVAILABLE SAFE OPPORTUNITY OR NEXT DRYDOCKING, WHICHEVER OCCURS FIRST. UNTIL THIS REQUIREMENT IS ACCOMPLISHED TO THE SATISFACTION OF THE COGNIZANT [name withheld] WILL BE REQUIRED (SEE 4B).
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 3 December 1991 Resolved
MARK ENDS OF WELD FRACTURE IN PINTLE NUT INSPECTION INSERT, INWAY OF RUDDERPORT SIDE. AT NEXT INSPECTION FOR CERTIFICATION, HAVE FRACTURE EXAMINED, TOINSURE FRACTURE DOSE NOT PROGRESS INTO MAIN RUDDER PLATE. MAKE PERMANENT_x001C_ REPAIR AT NEXT DRYDOCK.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 3 December 1991 Resolved
MAKE PERMANENT REPAIR AS ORIGINAL TO PITTED TOP PLATE OF STARBOARD HIGH SEA CHEST AT NEXT DRYDOCK.
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Fire Fighting
Issued 3 December 1991 Resolved
REPAIR AND PROVE OPERATION OF REACH ROD TO EMERGENCY FIRE PUMP VALVE
Condition: Unknown
Due 3 December 1991
Resolved 3 December 1991
Construction/Loadline
Issued 29 October 1991 Resolved
#3 PORT HOLD FORWARD HATCH COVER LEAVES DAMAGED. DAMAGE: MIDWAY DOWN THE FORWARD END OF FORWARD LEAF - GASKET CHANNEL BENT, OUTBOARD FORWARD CORNER OF AFT LEAF BENT, HINGES BENT, HATCH COVERS OUT OF ALIGNMENT. MAKE TEMP._x001C_ REPAIRS PRIOR TO LEAVING PUGET SOUND._x001C_
Condition: Unknown
Due 29 October 1991
Resolved 29 October 1991
Construction/Loadline
Issued 29 October 1991 Resolved
#3 FORWARD HOLD HATCH COVER LEAVES DAMAGED. DAMAGE: MIDWAY DOWN THE FORWARDEND OF FORWARD LEAF - GASKET CHANNEL BENT, OUTBOARD FORWARD CORNER OF AFT_x001C_ LEAF BENT, HINGES BENT, HATCH COVERS OUT OF ALIGNMENT. MAKE PERMANENT REPAIRS PRIOR TO NEXT FOREIGN VOYAGE OR PRIOR TO LEAVING NEXT US PORT.
Condition: Unknown
Due 29 October 1991
Resolved 29 October 1991
Fire Fighting
Issued 8 February 1991 Resolved
MAKE THE SMOKE DETECTION SYSTEM REPEATER ON THE BRIDGE FOR THE ENGINE ROOM OPERATIONAL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Engineering
Issued 8 February 1991 Resolved
INSTALL FIXED SPILL CONTAINMENT IAW 33CFR 155.320-(2) FOR LUBE AND FUEL TANKS ON THE STERN AREA, PORT AND STARBOARD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Engineering
Issued 8 February 1991 Resolved
CLEAN TO BARE METAL THE INTERNAL AREA OF THE SERVICE AIR RECEIVER, FWD, OUTBOARD IN WAY OF CIRCUMFRENTIAL AND LONGITUDINAL WELD AND CHECK THICKNESSOF SHELL TO CONFORM WITH ASME CODE SECTION VIII, UG,27.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Navigation
Issued 8 February 1991 Resolved
MAKE THE LOW SUMP LEVEL ALARM FOR THE STEERING SYSTEM OPERATIONAL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Fire Fighting
Issued 8 February 1991 Resolved
RENEW HOSE STATION BOXES ON WEATHER DECK FOR HYDRANTS, #13, #15, #16 AND #21.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Electrical
Issued 8 February 1991 Resolved
REPLACE THE FOLLOWING INOPERATIVE GENERAL ALARM BELL ON THE MAIN DECK; AFT PORT MG ROOM, AFT STBD EMER. LOCKER, STOLKENHAUSE CRANE AREA, AND FOCSLE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Accommodation/Occupational Safety
Issued 8 February 1991 Resolved
INSTALL FIXED TOILET IN HOSPITAL SPACE AS PER 46 CFR 92.20-35 (E).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Navigation
Issued 8 February 1991 Resolved
PROVE COMPLIANCE OF NAVIGATION LIGHTS WITH 74 COLREGS AND UL 1104, OR REPLACE WITH FIXTURES THAT DO COMPLY.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Lifesaving
Issued 8 February 1991 Resolved
PROVIDE DOCUMENTATION AND LABELS FOR CG APPROVAL OF ALL FITZWRIGHT EXPOSUREOR REPLACE WITH CG APPROVED UNITS.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Fire Fighting
Issued 8 February 1991 Resolved
CHANGE COLOR OF ALL NONE GENERAL ALARM LIGHTS TO COLOR OTHER THAN RED.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Electrical
Issued 8 February 1991 Resolved
MAKE OPERABLE THE OVERSPEED TRIP ON THE #3 S/S GENERATOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Engineering
Issued 8 February 1991 Resolved
MAKE OPERATIONAL THE LOW FUEL OIL SHUT DOWN FOR THE AUX. BOILER.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Electrical
Issued 14 March 1990 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR TRIPS (OVERSPEED AND LOW LUBE OIL PRESS.) AND ALARMS (HIGH JACKET WATER TEMP AND LOW LUBE OIL PRESS.)
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Electrical
Issued 14 March 1990 Resolved
PROVIDE INDICATOR IN CONTROL ROOM TO SHOW WHEN EMERGENCY GERERATOR IS CARRYING THE EMERGENCY LOAD.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Electrical
Issued 4 December 1989 Resolved
REPAIR/REPLACE ONE EMERGENCY LIGHT ON B DECK, PORTSIDE, FORWARD, AND ONE ONTHE BRIDGE DECK, STARBOARD SIDE, OUTSIDE OF THE PILOTHOUSE AFT.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Fire Fighting
Issued 4 December 1989 Resolved
PROVIDE USCG APPROVED COPY OF FIRE SAFETY PLAN SHOWING CORRECT LOCATIONS OF REMOTE SHUTDOWNS IN ENGINEER'S CHANGE ROOM AND ON BRIDGE.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Electrical
Issued 4 December 1989 Resolved
SHOW THAT LIFEBOAT EMBARKATION EMERGENCY FLOODLIGHTS ARE SUPPLIED POWER FROM THE EMERGENCY PANEL IN THE WHEELHOUSE/CHARTROOM/GYRO ROOM. POWER FOR LIGHTS MUST USE A SWITCH AND FUSE, OR A CIRCUIT BREAKER AS PER 46 CFR 112.43-7(A)(2).
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Accommodation/Occupational Safety
Issued 4 December 1989 Resolved
PROVIDE PERMANENT LABELING FOR REMOTE SHUT DOWNS ON BRIDGE AND ENGINEER'S CHANGE ROOM. PERMANENTLY LABEL VENTILATION SWITCHES ON MAIN SWITCHBOARD WITH "IN CASE OF FIRE TRIP TO STOP VENTILATION" AS PER 46 CFR 111.103-1.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Construction/Loadline
Issued 16 June 1989 Resolved
ALL B-CLASS JOINER DOORS ON VESSEL ARE REQUIRED TO BE REPLACED WITH DOORS MEETING B-CLASS STRUCTURAL FIRE PROTECTION REQUIREMENTS. TESTS CONDUCTED BY UL LABORTORIES ON 07JUN89 PROVED EXISTING DOORS GENERATED EXCESSIVE SMOKE LEVELS FROM BURNING OF SURFACE MATERIAL ON DOORS.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Electrical
Issued 26 May 1989 Resolved
DEMONSTRATE OPERATION OF EMERGENCY LIGHTING SYSTEM FOR COMPLIANCE WITH 46 CFR 112.43. VERIFICATION BY ONBOARD TEST AND INSPECTION WILL BE ACCEPTED TO SHOW COMPLIANCE WITH REGULATIONS.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Accommodation/Occupational Safety
Issued 26 May 1989 Resolved
DEMONSTRATE OPERATION OF REMOTE VENTILATION STOPPING SYSTEMS FOR COMPLIANCEWITH 46 CFR 111.103. VERIFICATION BY ONBOARD TEST & INSPECTION WILL BE ACCEPTED TO SHOW COMPLIANCE WITH REGULATIONS.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Fire Fighting
Issued 17 May 1989 Resolved
REPLACE ALL ELASTOMETRIC JOINT RINGS (COUPLINGS) IN THE FIRE MAIN SYSTEM WITH USCG APPROVED TYPE SUITABLE FOR SERVICE TEMPERATURES OF AT LEAST 1700 DEGREES F AS PER G-MSC-2 LTR M-90357 DTD 09MAY89.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Electrical
Issued 17 May 1989 Resolved
PROVIDE APPROVED PLANS FOR EMERGENCY GENERATOR INSTALLATION INCLUDING WIRING SPECIFICATIONS, DISTRIBUTION PANEL, CIRCUIT PROTECTION, AND LOAD ANALYSIS.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Engineering
Issued 12 April 1989 Resolved
PROVIDE APPROVAL FOR ENGINE ROOM REMOTE FUEL OIL VALVE CLOSING SYSTEM AS REQUIRED BY MSC LETTER 20DEC88 M-81207 COMMENTS #2 AND #3.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR THE HYDRAULIC ACCUMULATOR AS REQUIRED BY MSC LETTER 22SEP88 M-80958 COMMENTS #3 & 4.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
FINAL APPROVAL OF THE PERIODIC AUTOMATION TEST PROCEDURE FOR THE MAIN AND AUXILIARY MACHINERY IS REQUIRED BY THE OCMI OFFICE THAT WILL CONDUCT THE FULL PRELIMINARY TEST OF THE AUTOMATION PROCEDURE PRIOR TO THE VESSEL BEGINNING THE REQUIRED SIX (6) MONTH TRIAL PERIOD. COMMENT #1 OF (CONT.)
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PROVIDE A TEST SWITCH FOR THE EMERGENCY GENERATOR ON THE EMERGENCY SWITCH- BOARD, AS REQUIRED BY 46 CFR 112.45-5.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
DEMONSTRATE OVERSPEED TRIPS ON THE S/S GENERATORS ARE SET SO THE SPEED CANNOT EXCEED THE MAXIMUM RATED SPEED BY 15 PERCENT, AS PER 46 CFR 111.12-1(B).
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Construction/Loadline
Issued 18 January 1989 Resolved
REPAIR AND DEMONSTRATE SATISFACTORY OPERATION OF THE PNEUMATIC REMOTE CLOSURE SYSTEM FOR SEA VALVES (ACTUATED FROM THE ENGINEROOM CONTROL BOOTH).
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR MATERIAL STANDARDS FOR EXPANSION JOINTS AS REQUIRED BY MSC LETTER 31OCT88 M-81069 COMMENT #3.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR HYDRAULIC CONTROL PIPING AS REQUIRED BY MSC LETTER 28OCT88 M-81068 COMMENT #1.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Construction/Loadline
Issued 18 January 1989 Resolved
PROVIDE SATISFACTORY TEST DATA THAT STATE ROOM DOORS MEET B-CLASS REQUIRE- MENTS AS ADDRESSED IN MSC LETTER 08DEC88 H2-81286. IF DOORS PASS FIRE TEST WOOD MOLDING STRIPS ARE TO BE REMOVED AND METAL STRIPS INSTALLED AS ORIGIN-ALLY PROPOSED. IF FAILS TEST, NEW DOORS REQUIRED.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 18 January 1989 Resolved
PROVIDE APPROVED PLANS AND DEMONSTRATE TO THE SATISFACTION OF A COAST GUARDINSPECTOR, PRIOR TO USING, CABLE RELEASE INSTALLATION ON STARBOARD LIFEBOATDAVIT WINCH BRAKE RELEASE HANDLE OR REMOVE COMPLETELY.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Accommodation/Occupational Safety
Issued 18 January 1989 Resolved
REPAIR AND DEMONSTRATE SATISFACTORY OPERATION OF THE EVAPORATOR PRIOR TO DEPARTING SAN PEDRO, CALIFORNIA, AND IN NO CASE LATER THAN 01MAR89.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
MODIFY OR REPLACE AS NECESSARY THE REMOTE CONTROLLED VALVES IN THE PIPE TUNNEL AND DEMONSTRATE EMERGENCY/MANUAL OPERATION OF THESE VALVES (SEE COMMENT #1 OF MSC LETTER 22SEP88, M-80958).
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PROVIDE AUDIBLE ALARMS FOR LOW LUBE OIL PRESSURE AND HIGH JACKET WATER TEMPERATURE AND RUN INDICATOR LIGHT IN ENGINE CONTROL ROOM FOR THE EMER- GENCY GENERATOR AS PER 46 CFR 112.50(I) & 112.45-1(B) (AUDIBLE ALARMS RECOMMENDED TO BE MOUNTED IN THE ENGINEROOM CONTROL BOOTH).
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
OBTAIN TECHNICAL ACCEPTANCE OF VITAL SYSTEM AUTOMATION AS REQUIRED BY G-MSC-2 LTR 31AUG88 E-80577 COMMENT 3D.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR AQ3 AUXILIARY BOILER AS REQUIRED BY G-MTH-2 LETTER 02NOV88 16710/NOBLE STAR.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
SUBMIT DETAILS OF THE SOUND POWERED TELEPHONE SYSTEM AS REQUIRED BY COMMENT#11 OF MSC LETTER 24OCT88 E-80706.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR ADDITIONAL LIGHTING PLANS AS REQUIRED BY MSC LETTER 24OCT88 E-80707 COMMENT #2.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Navigation
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR ADDITIONAL WIRING PLANS FOR STEERING SYSTEM AS REQUIRED BY MSC LETTER 24OCT88 E-80707 COMMENTS #3.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PROVIDE APPROVED PLANS FOR EMERGENCY GENERATOR INSTALLATION INCLUDING WIRING SPECIFICATIONS, DISTRIBUTION PANEL, CIRCUIT PROTECTION AND LOAD ANALYSIS.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Accommodation/Occupational Safety
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR DOMESTIC HOT WATER HEATER AS REQUIRED BY MSC LETTER DATED 15DEC88, M-81190.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR LUBE OIL AND FRESH WATER COOLERS AS REQUIRED BY MSC LETTER'S 23NOV88 M81131, 27OCT88 M81067, AND COMMENTS 5 - 13 OF LETTER 17JAN89 M-90008.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
(CONT.) MSC LETTER E-90061 DTD 10FEB89 MUST BE SATISFIED. COMMENT #2 IS CONSIDERED SATISFIED BY [name withheld], OREGON. [name withheld] WILL NOT BE THE OFFICE STAMPING APPROVAL OF THE PROCEDURE AS THE VESSEL DEPARTED WITH OUT COMPLETING TESTING OF THE AUTOMATION PROCEDURE.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Unknown
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR THE FOLLOWING ITEMS AS REQUIRED BY MSC LTR M-80978 DATED 29SEP88 COMMENT NUMBERS: (9) LUBE OIL SEPARATOR HEATERS, (12) SALT- WATER COOLERS & CONDENSERS, (14) FUEL OIL HEATERS, AND (29) FEED AND DRAIN LINE CONDENSERS & HEATERS.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Fire Fighting
Issued 18 January 1989 Resolved
PROVIDE DETAILS FOR APPROVAL OF THE EMERGENCY FIRE PUMP INSTALLATION IN #2 CARGO HOLD AS PER MSC LETTER 29SEP88 COMMENT #3.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR MAIN SWITCHBOARD DRAWING TO SATISFY COMMENT #4 OF MSC LETTER 26AUG88 E-80577.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR ENGINE ROOM REMOTE FUEL OIL VALVE CLOSING SYSTEM AS REQUIRED BY MSC LETTER 20DEC88 M-81207 COMMENTS #2 AND #3.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Engineering
Issued 18 January 1989 Resolved
PROVIDE APPROVAL FOR MATERIAL COMPARISONS FOR ALL VALVES, FITTINGS, AND FLANGES FOR CLASS I AND II VITAL PIPING SYSTEMS AS REQUIRED BY MSC LETTER 15DEC89 M-81180 COMMENTS #3,4 AND 5.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Navigation
Issued 29 July 1986 Resolved
THE VESSEL DID NOT HAVE US CHART 12304 OF A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 29 July 1986
Resolved 29 July 1986
Navigation
Issued 30 July 1985 Resolved
THE VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES OF THE ROAD ON BOARD
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Navigation
Issued 30 July 1985 Resolved
THE VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF OR EXTRACT FROM THE U.S. COAST PILOT OR A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Navigation
Issued 30 July 1985 Resolved
THE VESSEL DID NOT HAVE OPERATING INSTRUCTIONS AND BLOCK DIAGRAM FOR THE VESSEL'S STEERING SYSTEM POSTED ON THE BRIDGE
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Navigation
Issued 30 July 1985 Resolved
THE VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF OR EXTRACT FROM THE U.S. COAST GUARD LIGHT LIST OR A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985

Casualty record · 6

20 November 2007Routine · role: Involved in a Marine Casualty · activity 3127129
26 May 2008Routine · role: Involved in a Marine Casualty · activity 3220937
1 February 2010Routine · role: Involved in a Marine Casualty · activity 3714905
21 April 2011Routine · role: Involved in a Marine Casualty · activity 3995105
5 January 2012Routine · role: Involved in a Marine Casualty · activity 4222435
18 February 2012Routine · role: Involved in a Marine Casualty · activity 4248756
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.