MAURY USCG vessel records Sign in
← All vessels

WATANNA II

WATANNA II is a 1988 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1989, most recently in May 2026, along with 51 deficiencies and 1 casualty investigation in 2007.

Records from 1989 to 2026. Most recent: inspection, 19 May 2026.

Built
1988
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4645
320315
Flag
UNITED STATES
366922690
Maury page id
psix-320315

Inspections, by type

…with no type recorded6
Years with a record 32 calendar years (1989–2026)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.8 ft × 16.5 ft × 7.0 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderADAMS BOAT CO., INC. · MADISON, IN, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPORT CLINTON, OH
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 9 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4645MMSI 366922690 · active · compulsorily equipped · granted 29 March 2017, expires 29 March 2027
WUS3368MMSI 366922690 · cancelled · compulsorily equipped · granted 26 February 2014, cancelled 23 March 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JET EXPRESS II Passenger (Inspected) · MISLE 372100 · 26 April 1994 · activity 63858

Inspection history · 55

19 May 2026 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8376330
17 April 2026 Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8350588
30 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8198332
7 January 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8058889
19 April 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7901902
11 April 2023 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7664005
16 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7457456
5 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7445313
2 May 2022 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7439871
19 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7179677
5 May 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6953047
29 April 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6672710
18 December 2018 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6602091
9 April 2018 COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6387770
20 April 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6129097
15 September 2016 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6001384
10 May 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5880285
6 April 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3444089
9 January 2009 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3376834
21 April 2008 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3188641
4 June 2007 Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2973547
1 June 2007 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2970371
29 March 2007 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2897699
20 March 2006 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2606060
11 April 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2330904
4 October 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2212818
27 April 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2053894
10 December 2003 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1961979
2 April 2003 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1767630
1 October 2002 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1679224
20 September 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1418971
25 September 2000 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1415482
4 October 1999 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1415251
3 December 1998 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 805498
5 October 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 801202
24 March 1998 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 761937
23 February 1998 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 190185
2 October 1997 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1381012
25 March 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1377954
26 November 1996 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1388175
25 March 1996 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1081481
22 March 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1460780
26 April 1994 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 63858
23 March 1994 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1165978
1 December 1993 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1448483
1 April 1993 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1147379
22 March 1993 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 834239
17 September 1992 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 97486
23 March 1992 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 952606
20 March 1991 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 997146
23 March 1990 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1227313
11 May 1989 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1203924
16 March 1989 Initial Certification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 896214
16 March 1989 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1209794
16 March 1989 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1210631

Deficiency record · 51

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 April 2026 Resolved
Fire fighting and Abandon ship/man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics. Vessel could not provide logs to show drills where being completed. 46 CFR 185.524(d) 46 CFR 185.520(f)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 April 2026 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel could not provide logs to show monthly inspections of fire extinguishers where being completed. 46 CFR 176.810(b)(ii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 April 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Vessel had no visual indicator for the high level bilge alarm. 46 CFR 182.530
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 April 2026 Resolved
The master of the vessel shall ensure that each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Vessel could not provide logs to show monthly tests where being completed. 46 CFR 185.728(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 April 2026 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have emergency instructions posted. 46 CFR 185.510(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 April 2026 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessels EPIRB has an expired battery. Vessel is restricted to three miles from shore until EPIRB battery is replaced. Vessel is to ensure if EPIRB is replaced that it is properly registered with NOAA. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2026
Resolved 19 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 April 2024 Resolved
Retro-Reflective tape and Outer coating on Life Float and BA found deteriorated. Life Float and BA retro-reflective tape needs to be replaced in accordance with NVIC 1-83 and BA should be coated in accordance with 46 CFR 160.010.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 27 August 2024
Resolution: Vessel representative provided documentation of retroreflective tape replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 April 2023 Resolved
EACH VESSEL SHALL CARRY ON BOARD A FIRST AID KIT APPROVED IN ACCORDANCE WITH 160.041 OF THIS PART. THE VESSEL HAD A FIRST AID KIT THAT DID NOT MEET THE REQUIREMENTS OF 160.041 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 26 April 2024
Resolution: Cleared during due date, but failure to document in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 April 2023 Resolved
VESSELS ON A GREAT LAKES ROUTE SHALL CARRY SIX HAND RED AND SIX HAND ORANGE SMOKE DISTRESS SIGNALS. VESSEL HAD SIX ORANGE AND THREE RED DISTRESS SIGNALS. 46CFR180.68(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 26 April 2024
Resolution: Cleared during due date, but failure to document in MISLE.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 April 2023 Resolved
EACH VESSEL SHALL CARRY UPDATED CHARTS AND PUBLICATIONS. THE CHARTS, LIGHT LIST, TIDE TABLES, AND COAST PILOT WERE NOT UPDATED. *UPDATED LIGHT LIST ADDED TO THE VESSEL PRIOR TO INSPECTION COMPLETION. 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 26 April 2024
Resolution: Cleared during due date, but failure to document in MISLE.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2023 Resolved
WIRING JOINTS AND SPLICES SHALL BE MECHANICALLY SECURE AND MADE IN A JUNCTION BOX. MULTIPLE CONNECTIONS/SPLICES WERE MADE, I OUTSIDE OF JUNCTION BOXES AND EXPOSED TO WEATHER/WATER CONDITIONS. 46CFR183.05-50(b)(1) "OLD T"46CFR183.05-50(b)(1) "OLD T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 26 April 2024
Resolution: Cleared during due date, but failure to document in MISLE.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 May 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 6 May 2022
Resolution: Received photograph of newly purchased/installed HRU.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 May 2022 Resolved
A VESSEL MUST CARRY A FLOATING WATERLIGHT. THE FLOATING WATERLIGHTS ON THE VESSEL WERE NOT OPERATING AS APPROVED, DUE TO THE BATTERIES NEARING THE END OF THEIR SERVICE LIFE. VESSEL RESTRICTED TO DAYTIME OPERATIONS. 46CFR180.70(d)
Action required: 705 - Other - as specified
Resolved 2 May 2022
Resolution: VESSEL REPS REPLACED WATERLIGHT BATTERIES.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 May 2022 Resolved
EACH VESSEL SHALL CARRY UPDATED CHARTS AND PUBLICATIONS. THE CHARTS, LIGHT LIST, TIDE TABLES, AND COAST PILOT WERE NOT UPDATED. 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: UPDATED PUBS/CHARTS WERE ON BOARD.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2022 Resolved
A VESSEL MUST CARRY A FIRST AID KIT APPROVED UNDER 160.041 OR A KIT WITH EQUIVALENT CONTENTS AND INSTRUCTIONS. THE VESSEL DID NOT HAVE A FIRST AID KIT MEETING THE CONTENTS REQUIREMENTS. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2022
Resolution: Invoice and photos of first aid kit were received.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 May 2022 Resolved
EACH DISCHARGE PIPE BELOW A LINE 6-INCHES ABOVE THE DEEPEST LOAD WATERLINE SHALL HAVE A MEANS FOR STOPPING THE INGRESS OF WATER. CAP THE PIPE IN PORT ENGINE ROOM. 46CFR179.350(c) 46CFR179.350(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: THROUGH HULL WAS CAPPED.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 May 2022 Resolved
A PENETREATION IN A WATERTIGHT BULKHEAD SHALL BE AS HIGH AND CENTERLINE AS PRACTICABLE AND MADE WATERTIGHT. THE WATERTIGHT BULKHEAD CABLE PENETRATIONS BETWEEK THE ENGINE ROOM AND THE VOID FORWARD OF IT WERE NOT WATERTIGHT; MAKE PENETRATIONS WATERTIGHT. 46CFR179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: PENETRATIONS WERE FILLED.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 May 2022 Resolved
WIRING JOINTS AND SPLICES SHALL BE MECHANICALLY SECURE AND MADE IN JUNCTION BOXES. MULTIPLE SPLICES WERE MADE WITH BUTT CONNECTORS, OUTSIDE OF JUNCTION BOXES. PLACE SPLICE CONNECTIONS IN JUNCTION BOXES. "OLD T" 46CFR183.05-50(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2022
Resolution: CONNECTIONS WERE PALCED IN WATERTIGHT ENCLOSURES.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2021 Resolved
Identified 21 life jackets that were damaged/worn beyond service/repair. Operator must provide a life jacket for each person carried on board the vessel. Operator was able to place 06 new on board during inspection. Vessel is authorized to carry 38 total persons on board until new life jackets are placed in service.
Action required: 705 - Other - as specified
Resolved 21 April 2021
Resolution: Company has purchased new Type I PFD's, properly marked and placed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2019 Resolved
Buoyant Apparatus must be repaired to the manufacture standards. repair within the next 30 days
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2019
Resolved 30 April 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 December 2018 Resolved
Pitting on Starboard side aft above the trim tab. Repair pitting and incorporate maintenance schedule and inspection for next dry dock.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 February 2019
Resolved 13 March 2019
Resolution: Pitting on Starboard side aft above the trim tab was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2018 Resolved
Portside Main Diesel Engine mount bolts are sheared off on both mounts on the forward portion on the engine. Replace bolts and repair engine mounts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 February 2019
Resolved 13 March 2019
Resolution: Portside Main Diesel Engine mount bolts were replaced on both mounts on the forward portion on the engine. Forward engine mounts are now securely attached.
Communications › Radio Communications › EPIRB
Issued 17 April 2018 Resolved
Vessel's EPIRB Hydrostatic Release Unit (HRU) had an expiration date of March 2018. Vessel is restricted to no more than three NM from shore until the HRU is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 19 April 2018
Resolution: Verified vessel has new HRU installed. Vessel is no longer restricted to 3nm from shore.
Communications › Radio Communications › EPIRB
Issued 10 May 2016 Resolved
The hydrostatic release unit (HRU) on the EPIRB is not marked with the expiration date. [name withheld] with expiration date of 2 years after installation date IAW 46 CFR 185.740.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 15 September 2016
Lifesaving › Lifefloat › Markings
Issued 10 May 2016 Resolved
The vessel name is faded on the lifefloat and BA. Mark vessel name on both pieces of equipment IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 15 September 2016
Lifesaving › Buoyant Apparatus › Painter
Issued 10 May 2016 Resolved
The buoyant apparatus (BA) painter is deteriorated. Replace painter IAW 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 15 September 2016
Lifesaving › Lifefloat › Painter
Issued 10 May 2016 Resolved
The painters for the lifefloat and the buoyant apparatus (BA) were found un-connected to the vessel and tightly wrapped (non-deployable). Configure painters IAW 46 CFR 180.130, .137 and .175.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2016
Resolved 15 September 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 April 2009 Resolved
Unable to conduct Man overboard drill due to in climate weather.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 13 April 2009
Resolution: Conducted man overboard drill at pier.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 29 March 2007 Resolved
Bilges full of oily water and need to be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 29 March 2007
Resolution: Crew cleaned bilges with sat results.
Engineering › Fuel Oil Service System › Hose
Issued 20 March 2006 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 20 March 2006
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 20 March 2006 Resolved
Port engine #6 injector return leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 20 March 2006
Construction/Loadline › Hull › Weld
Issued 11 April 2005 Resolved
Repair two fractures on starboard steering foundation.
Condition: Unknown
Due 11 April 2005
Resolved 13 April 2005
Engineering › Fuel Oil Service System › Hose
Issued 11 April 2005 Resolved
Replace starboard engine fuel hose from filter to fuel pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2005
Resolved 12 April 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 April 2004 Resolved
Blanket or guard starboard engine exhaust.
Condition: Improper Installation
Due 10 June 2004
Resolved 8 September 2004
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 27 April 2004 Resolved
Properly label child lifejacket stowage area.
Condition: Improper/Lack of Maintenance
Due 10 June 2004
Resolved 8 September 2004
Engineering › Bilge Water Management System › Piping
Issued 27 April 2004 Resolved
Install check valve on bilge system
Condition: Improper Installation
Due 11 February 2005
Resolved 11 April 2005
Electrical › Lighting (emergency)
Issued 2 April 2003 Resolved
Broken cover on high water alarm sensor.
Due 2 April 2003
Resolved 2 April 2003
Engineering › Lubricating Oil Service System
Issued 2 April 2003 Resolved
Stbd. engine outboard oil line has excessive vibration, causing oil to leak out from the fitting.
Due 2 April 2003
Resolved 2 April 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 October 2002 Resolved
Ensure child and adult PFD's are segregated. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 October 2002 Resolved
Carry only 52 passenger and crew until an additional PFD is provided. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2002
Resolved 1 October 2002
Engineering › Bilge Water Management System
Issued 1 October 2002 Resolved
Prove proper operation of the vessels bilge system. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2002
Navigation › Collision/Grounding Avoidance
Issued 1 October 2002 Resolved
Replace ICOM radio mic wire.
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 1 October 2002
Stability › Watertight Integrity
Issued 1 October 2002 Resolved
Label engine room water tight door, Keep closed while vessel is underway.
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 2 April 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 October 2002 Resolved
Install stbd engine crank case breather cap.
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 2 April 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 October 2002 Resolved
Properly install chaffing gear on the stbd engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2002
Resolved 2 April 2003
Stability › Watertight Integrity
Issued 1 October 2002 Resolved
Make the forward collision blkhd watertight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2002
Resolved 2 April 2003
Stability › Watertight Integrity
Issued 1 October 2002 Resolved
Repair or remove abandoned fire pump and bilge system. LEGACY COMPONENT DESC: bilge system
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 2 April 2003
Communications › Audible Communications
Issued 1 October 2002 Resolved
Ensure passenger orientation meets the requirements of 46CFR 185.506.
Condition: Improper/Lack of Maintenance
Due 1 November 2002
Resolved 2 April 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 1 October 2002 Resolved
Repair raw water leak on stbd engine, top of heat exchanger.
Condition: Unknown
Due 1 November 2002
Resolved 2 April 2003
Lifesaving
Issued 22 March 1993 Resolved
VESSEL TO CONDUCT U/W DRILLS WHEN ICE CONDITIONS PERMIT VESSEL TO BE PLACEDBACK IN THE WATER, OR WITH IN 30 DAYS.
Condition: Unknown
Due 22 March 1993
Resolved 22 March 1993
Documentation
Issued 16 March 1989 Resolved
PASSENGERS SHALL NOT BE CARRIED UNTIL A RADIOTELEPHONE SAFETY CERTIFICATE HAS BEEN ISSUED TO THE VESSEL BY THE FEDERAL COMMUNICATIONS COMMISSION. REQUIREMENT TO BE COMPLETED PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989

Casualty record · 1

1 June 2007Routine · role: Involved in a Marine Casualty · activity 2970371
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.