Records from 1987 to 2026. Most recent: inspection, 29 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 59
29 June 2026
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8433969
30 December 2025
Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8288341
8 October 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8249592
12 June 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7933724
19 October 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7811142
7 February 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7635905
9 August 2022
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7534834
1 October 2021
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7324905
5 November 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7089890
14 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7035635
22 November 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6860573
21 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6839726
26 September 2018
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6548902
13 March 2018
Damage Survey · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6371304
23 May 2017
Examination of Repairs · Hull Examination · DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293188
9 May 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5870758
12 June 2014
COI Inspection · Simplified Stability Test · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4914085
11 May 2012
Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4300356
2 March 2010
COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3685604
1 March 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3688126
21 January 2009
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3396757
24 April 2008
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3181143
4 June 2007
Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2948624
6 March 2007
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2882491
10 March 2006
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2601293
1 February 2006
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2576920
14 October 2005
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2514650
1 June 2005
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2374689
15 February 2005
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2292688
1 February 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2284325
21 January 2005
Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2280276
10 June 2004
Administrative Inspection · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2093680
4 June 2003
Annual Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1805582
11 June 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1629354
6 June 2001
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391589
15 June 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 818728
14 June 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1050892
26 May 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1470558
10 June 1999
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395216
9 June 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446686
16 June 1997
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1407978
13 June 1996
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445114
14 September 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1187538
28 August 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 876900
16 June 1995
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 877030
16 June 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 868776
18 June 1993
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1153968
24 April 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 829725
14 September 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1247873
27 September 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1253119
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1310107
6 May 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223900
21 November 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1216242
26 September 1990
Drydock Extension · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900350
27 September 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1002971
24 May 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352055
25 November 1988
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1209012
24 November 1987
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1009609
22 October 1987
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1004691
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 January 2026
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements installation certificates to be issued by the Federal Communications Commission
Vessel Radiotelephony Certificate expired.
Restricted from operating more than 1000 feet from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2026
Resolution: Owners aquired new Radiotelephony certificate, sent in through email.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Life ring was not labeled with the vessel name. 46 CFR 185.604(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 23 October 2025
Resolution: Submitted photo of labeled Life Ring
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050.
Waterlight did not have the correct batteries installed that were indicated on the light IAW the type approval. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 23 October 2025
Resolution: Sumbitted photos of correct battery installation.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2019
Resolved
46 CFR 183.420. All vessels must have navigation lights in compliance with the applicable sections of the Intl/Inland Navigation Rules. Replace Mast Head Light on vessel.
Vessel is not permitted to do night time operations until fixed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 October 2019
Resolved 12 November 2019
Resolution: Vessel provided pictures of new light
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 October 2019
Resolved
46 CFR 185.604 (b)-Each lifejacket must be marked with type I retrorefelctive material. Ring life buoys must be marked with Type II retroreflective. Replace retro-reflective on lifering and 03 child lifejackets.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 12 November 2019
Resolution: Ring Buoy now has retro-reflective tape
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 21 October 2019
Resolved
46 CFR 185.570 (f) 46 CFR 185.728(c)-Abandon ship drills and MOB drills and training shall be logged or documented for reviewof Coast Guard. The drill shall have date/drill training and general description. Each EPIRB must be tested monthly. Operators are not logging monthly EPIRB tests and do not have record of drills. Provide record of drills.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 12 November 2019
Resolution: Vessel provided copy of drills/ safety checks done on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2018
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Provide two (2) more life jackets to bring total to fifty one (51) serviceable life jackets. 46 CFR 180.25-5(b).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2018
Resolved 9 November 2018
Resolution: Obtained two new lifejackets to replace the two non-serviceable life jackets. Verified by attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2018
Resolved
All wiring shall be run as high as practicable above bilges and shall be protected in accordance with NCE. Clean up wires running aft to forward in port and starboard hulls to keep out of bilge and protect against chafing in feedthrough.
46 CFR 183.05-50(a)(1)&(2).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 9 November 2018
Resolution: Wires in both hulls were rerouted and properly installed to prevent chafing and keep it out of the bilge.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 September 2018
Resolved
Placards containing instructions for the donning and use of lifejackets must be posted in conspicuous places. Post lifejacket donning placard on vessel. 46 CFR 185.516(a).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2018
Resolved 9 November 2018
Resolution: Placards for lifejacket donning have been posted on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2018
Resolved
The name of vessel must be marked on each ring life bouy. Mark ring life bouy with vessel name. 46 CFR 185.604(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 9 November 2018
Resolution: The name of the vessel has been properly marked on the ring life bouy.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 September 2018
Resolved
A visual indicator must be provided at the operating station to indicate when automatic bilge pump is operating. Renew bilge pump light. 46 C FR 182.530(c).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2018
Resolved 9 November 2018
Resolution: Bilge pump lights and alarms have been replaced and work as required.
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 23 May 2017
Resolved
Fuel hose is cracked and must be renewed.
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 30 June 2017
Resolution: New fuel lines were installed. all sat.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 May 2017
Resolved
Company does not have a licensed master. Vessel is not allowed to operate until a licensed master has been hired, drug tested and has conducted drill.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2017
Resolved 30 June 2017
Resolution: Company hired 2 new captains and has conducted drills.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 May 2017
Resolved
Due to lack of crew, vessel was unable to conduct underway drills. Conduct drills once crew is hired.
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 30 June 2017
Resolution: CRew was provided and drills were conducted.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 May 2017
Resolved
Vessel does not have a life jacket donning placard. Provide and post.
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 30 June 2017
Resolution: Life jacket donning placard was posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 May 2017
Resolved
First aid kit is missing contents. Provide new contents or a new kit.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: New CG approved first aid kit was provided.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 2 March 2010
Resolved
Fuel tanks do not have proper ventilation. The vents are open without flame screen. Install proper ventilation as per 46 CFR 182.450.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 8 April 2010
Resolution: New fuel tank fill caps and vents installed. All sat.
Lifesaving › Hand Flares › Not on Board
Issued 2 March 2010
Resolved
Vessel does not have orange smoke signals on board.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2010
Resolution: Orange smoke signals provided on board. All sat.
Construction/Loadline › Hull › Side Shell
Issued 24 February 2010
Resolved
Vessel has crack in fiberglass on inside bulkhead, in toilet compartment. Repair cracked bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 8 April 2010
Resolution: All fiberglass repairs done.
Engineering › Gasoline Engine (propulsion) › Carburetor (4 cycle)
Issued 10 March 2006
Resolved
Prove proper operation of STBD Engine (stalling) prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2006
Resolved 10 March 2006
Resolution: Verified on site operation
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 1 February 2006
Resolved
Replace wasted BII fire extinguisher prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2006
Resolved 2 February 2006
Resolution: Cleared
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 1 February 2006
Resolved
Properly mount BI fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2006
Resolved 2 February 2006
Resolution: Cleared
Engineering › Fuel Oil Service System › Piping
Issued 1 February 2006
Resolved
Repair/replace/relabel emergency fuel shut offs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2006
Resolved 2 February 2006
Resolution: Cleared
Construction/Loadline › Hull › Hull Plating
Issued 1 June 2005
Resolved
GRIND OUT FRACTURE AND PROPERLY REPAIR FRP DAMAGE AT PORT BOW.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2005
Resolved 1 June 2005
Construction/Loadline › Hull › Bottom Plating
Issued 1 June 2005
Resolved
GRIND OUT CHIPS IN GELCOAT AND FILL WITH EPOXY IN WAY OF INBOARD TUNNEL SIDESHELL STARBOARD HULL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2005
Resolved 1 June 2005
Navigation › Piloting/Steering › Marine Charts
Issued 15 February 2005
Resolved
PROVIDE CURRENT NAVIGATION CHART, COAST PILOT, AND LIGHT LIST.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 February 2005
Resolved
PROVIDE A MASTHEAD LIGHT AS PER NAVRUL 23.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 February 2005
Resolved
PROVIDE A PROPER GATE OR MESH FOR BOW ACCESS ENTRYWAY WITH NO GREATER THAN 4" GAP.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 15 February 2005
Resolved
PROVIDE A PROPER SIZE ANCHOR FOR VESSEL ALONG WITH CHAIN AND LINE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 February 2005
Resolved
PROVIDE 3 ADDITIONAL TYPE I ADULT SIZE PFD'S ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 February 2005
Resolved
POST A PFD DONNING PLACARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Fire Fighting › Fire Bucket › Quantity
Issued 15 February 2005
Resolved
PROVIDE 1 ADDITIONAL FIRE BUCKET ONBOARD VESSEL.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 18 February 2005
Engineering › Bilge Water Management System › Valve
Issued 15 February 2005
Resolved
PROVIDE A POSITIVE CLOSURE VALVE FOR EACH BILGE PUMP OVERBOARD AT THE HULL CONNECTION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2005
Resolved 1 June 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 February 2005
Resolved
PROPERLY INSULATE AND SECURE OR MOUNT THE THREE CABLE SPLICE LOCATED UNDER THE CONTROL CONSOLE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Construction/Loadline › Structures › Deck Plating
Issued 15 February 2005
Resolved
REINFORCE WEAK AREA OF MAIN DECK AMIDSHIPS JUST AFT OF CONTROL STATION SEAT AT NEXT DRYDOCK.
Due 30 November 2005
Resolved 1 February 2006
Resolution: Properly repaired
Documentation › Markings/Placards › Vessel Number (state)
Issued 15 February 2005
Resolved
APPLY NAME OF VESSEL TO HULL.
Due 15 March 2005
Resolved 18 February 2005
Lifesaving › Lifebuoys › Quantity
Issued 15 February 2005
Resolved
RENEW RING BOUY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 18 February 2005
Lifesaving
Issued 6 June 2001
Resolved
PROVIDE 2 ADDITIONAL ADULT TYPE I LIFE JACKETS. PASSENGER CAPACITY REDUCEDTO 47 UNTIL DEFICIENCY CLEARED.
Condition: Unknown
Due 6 July 2001
Resolved 25 June 2001
Engineering
Issued 6 June 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, REPLACE FUEL HOSES FROM FUEL TANK TO OUTBAORDS.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Construction/Loadline
Issued 6 June 2001
Resolved
PRIOR TO CARRIAGE OF PASSNGERS, REPAIR BILGE LINE AT THROUGH HULL.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Lifesaving
Issued 26 May 2000
Resolved
REPLACE 19 PFD'S. VESSEL LIMITED TO 30 PSSENGERS PER VOYAGE UNTIL PROOF OFREPLACEMENT PROVIDED.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Engineering
Issued 26 May 2000
Resolved
REPLACE EMERGENCY SHUTOFF VALVES FOR EACH FUEL LINE.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Lifesaving
Issued 26 May 2000
Resolved
PROVIDE FIRST AID/CPR CERTIFICATIONS FOR 50% OF CREW.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Unknown
Issued 10 June 1999
Resolved
PROVIDE PROOF OF DRUG TESTING PER 46 CFR PART 16._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1999
Resolved 19 July 1999
Lifesaving
Issued 10 June 1999
Resolved
PROVIDE 12 ADDITIONAL ADULT PFD'S. VESSEL MAY ONLY CARRY 37 PASSENGERS, 39 TOTAL PERSONS UNTIL COMPLETE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1999
Resolved 19 July 1999
Lifesaving
Issued 10 June 1999
Resolved
LABIL RING BUOY W/ VESSELNAME, AFFIX RETRO TAPE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1999
Resolved 19 July 1999
Lifesaving
Issued 10 June 1999
Resolved
POST PFD DONNING INSTRUCTIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1999
Resolved 19 July 1999
Lifesaving
Issued 13 June 1996
Resolved
PROVIDE CG APPROVED FIRST AID KIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1996
Resolved 28 August 1996
Lifesaving
Issued 13 June 1996
Resolved
PAINT FLARE BOX BRIGHT COLOR, LABEL "DISTRESS SIGNALS"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1996
Resolved 28 August 1996
Fire Fighting
Issued 13 June 1996
Resolved
PROVIDE 3-2 1/2 GALLON FIRE BUCKETS WITH LANYARDS ATTACHED TO EACH, LABEL EACH "FIRE BUCKET"._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1996
Resolved 28 August 1996
Lifesaving
Issued 16 June 1995
Resolved
Label adult and child pfd stowage.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Construction/Loadline
Issued 16 June 1995
Resolved
Repair soft spot in deck port side outboard of helm.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Engineering
Issued 16 June 1995
Resolved
Label emergency fuel shut offs.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 26 September 1990
Resolved
PROVIDE AN EMERGENCY FLASHLIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Lifesaving
Issued 26 September 1990
Resolved
PROVIDE AN ADDITIONAL 3 ORANGE AND 3 RED FLARES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Engineering
Issued 27 September 1989
Resolved
PROVIDE FUEL TANK STOP VALVES.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989
Resolved
REPLACE RING BUOY GRAB LINE.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Navigation
Issued 27 September 1989
Resolved
REMOVE NET ON NAV. LIGHTS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Fire Fighting
Issued 27 September 1989
Resolved
PROVIDE CG APPROVED BRACKETS FOR 2 B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Engineering
Issued 27 September 1989
Resolved
REROUTE FUEL LINES TO PREVENT RUBBING.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Engineering
Issued 27 September 1989
Resolved
REPLACE FUEL LINES WITH USCG TYPE.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Construction/Loadline
Issued 27 September 1989
Resolved
PROVIDE 5' RIGID BILGE PUMP SUCTION HOSE.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Construction/Loadline
Issued 27 September 1989
Resolved
SEAL STERN PENETRATIONS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Documentation
Issued 24 May 1989
Resolved
CREDIT DRYDOCK DUE 24NOV90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989