Inspection history · 19
12 January 2026
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8310609
20 December 2024
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8057283
5 December 2024
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8064987
30 September 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8022910
17 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7810670
15 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7594164
22 September 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7563491
18 October 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7334764
21 October 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7082177
22 November 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6860782
25 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6631936
18 September 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6543106
24 August 2018
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6507217
11 December 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6322389
3 November 2017
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6300255
27 October 2017
Plan Review "T" Boat
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6296037
20 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6291949
8 November 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6037456
9 August 2016
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5967558
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 January 2026
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks.
MI observed 4 stbd transverse frames and 3 port transverse frames with minor water/moisture intrusion on the upper edges of the lower frame.
46 CFR 176.802
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2026
Resolution: Operator grinded corrosion spots to solid wood, fitted/installed marine grade plywood inserts and sealed with West Systems Epoxy and 3 layers of biax fiberglass.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 6 December 2022
Resolution: Received Pictures and documentation attesting to the correction of this item.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 November 2022
Resolved
Replace broken hinge on fwd port life jacket locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 6 December 2022
Resolution: Received Pictures and documentation attesting to the correction of this item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2022
Resolved
A Visual and audible alarm must be provided at the operating station. Label alarms to identify the spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 6 December 2022
Resolution: Received Pictures and documentation attesting to the correction of this item.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2022
Resolved
Relabel life jacket storage locations with type & amount being stored.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 6 December 2022
Resolution: Received Pictures and documentation attesting to the correction of this item.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2022
Resolved
Replace (4)four degraded children's life-jackets
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2022
Resolved 12 December 2022
Resolution: Recieved invoice for the purchase of the new lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2022
Resolved
Remove excess lines and fenders from the lifejacket storage lockers. Life jackets need to remain quickly accessible at all times.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 6 December 2022
Resolution: Received Pictures and documentation attesting to the correction of this item.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 October 2021
Resolved
Make FRP repairs to transverse stiffener frame immediately aft of the collision bulkhead in the port side hull. The entire frame is dry-rotted. Make FRP repairs to delaminated deck beam below the main deck on the same frame.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 25 October 2021
Resolution: Verified satisfactory FRP repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 October 2021
Resolved
Starboard side ladder has aluminum cracking at the top of the ladder mount. Make proper repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 25 October 2021
Resolution: Verified aluminum ladder repair completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2021
Resolved
Replace 06 adult lifejackets and 01 child lifejacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 25 October 2021
Resolution: PFDs replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 October 2021
Resolved
Re-stencil fuel shutoff marking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 25 October 2021
Resolution: Markings completed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 November 2019
Resolved
Provide rail courses or the equivalent so that no open space exists that is more than 12".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 18 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2019
Resolved
Provide one extra child size pfd.
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 18 October 2021
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 11 December 2017
Resolved
Conduct sea trials to prove proper operation of outboard motors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2017
Resolution: Sea trials completed. Motors found to be operating satisfactorily.
Communications › Visual Communication › Red Warning Signal
Issued 11 December 2017
Resolved
Provide 12 current flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2018
Resolution: New flares installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 December 2017
Resolved
Provide GPS enabled DSC Radio.
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 10 January 2018
Resolution: New radio installed and properly programmed.
Construction/Loadline › Structures › Superstructure
Issued 11 December 2017
Resolved
Make repairs to canopy framework.
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 10 January 2018
Resolution: Canopy frame properly secured.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 November 2016
Resolved
Properly secure battery boxes.
Action required: 705 - Other - as specified
Due 23 November 2016
Resolved 2 December 2016
Resolution: Batteries properly secured.
Documentation › Markings/Placards › Garbage Placard
Issued 8 November 2016
Resolved
Provide and post current MARPOL V placard.
Action required: 705 - Other - as specified
Due 23 November 2016
Resolved 2 December 2016
Resolution: Placard properly posted.
Construction/Loadline › Hull › Side Shell
Issued 10 August 2016
Resolved
Grind and fiberglass port transom corner and both bow stems.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Damaged area properly repaired.
Construction/Loadline › Hull › Side Shell
Issued 10 August 2016
Resolved
Replace through-hull fittings on port and stbd sides. Investigate water intrusion on port.
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Through hull fittings replaced and area in question examined for damage.
Construction/Loadline › Hull › Side Shell
Issued 10 August 2016
Resolved
Grind and fiberglass marked soft-spot on port side 15 aft of stem.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Spot ground to good material and re-fiberglassed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 August 2016
Resolved
Grind to good wood, replace and re-fiberglass rotted wood in the following web-frames: From Aft, PRT #2&3 and STBD #1,3&5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: Areas of rot ground down and re-fiberglassed.
Construction/Loadline › Structures › Deck Plating
Issued 10 August 2016
Resolved
Replace rotted longitudinal deck-beam inboard of head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: Beam sistered with new beam.
Construction/Loadline › Hull › Bottom Plating
Issued 10 August 2016
Resolved
Remove head through-hull fitting below head and re-seal fitting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Through hull fitting removed, area inspected and through hull replaced.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 August 2016
Resolved
Repair broken MSD vent line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Broken vent piping replaced.
Construction/Loadline › Penetrations › Bottom Plug
Issued 10 August 2016
Resolved
Make sea valves available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Sea valve inspected and found satisfactory.