← All vessels
SEA PRINCE
Freight Ship · General Dry Cargo Ship class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named SEA PRINCE
SEA PRINCE is a 1988 freight ship. The Coast Guard has recorded 13 inspections since 1988, most recently in March 2005, along with 5 deficiencies and 1 operational control.
Records from 1988 to 2005. Most recent: inspection, 14 March 2005.
- Built
- 1988
- Last inspected
- 14 March 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8707367 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3EW8
320824
Flag
PANAMA
—
Maury page id
psix-320824
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it18046 - Convention (Subpart B), Net Ton
38852 - Convention (Subpart B), Gross Ton
44241 - Dead Weight, Ton
53013 - Displacement, Ton
38852 - Convention (Subpart B), Gross Ton
44241 - Dead Weight, Ton
53013 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
14 March 2005
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2309111
16 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 390148
14 March 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 376228
25 January 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374655
29 December 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 504434
27 April 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 358070
3 October 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 503478
19 April 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 350198
27 December 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 457382
25 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 344030
27 January 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 335227
16 March 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 512003
11 November 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 326802
Deficiency record · 5
Engineering
Issued 16 April 1996
Resolved
Provide a means for securing emergency generator daily fuel oil service tank valve capable of being closed from a safe position outside the space inwhich the tank is situated in accordance with SOLAS 74 (AMENDED)II- 2/15.2.5
Fire Fighting
Issued 16 April 1996
Resolved
Provide on board vessel instructions for the operation and maintenance of all installations/equipment for the fighting and containment of fire._x001C_ SOLAS 74 (Amended) II-2/20
Engineering
Issued 16 April 1996
Resolved
Prove satisfactory operation of the oily-water separator. To the satisfaction of the attending U.S. Coast Guard Inspector._x001C_ MARPOL 73/78 Annex I/16
Engineering
Issued 25 January 1995
Resolved
Make permanent repairs to the wasted overboard line from the generators. The line is patched (box patch) between the sea valve and the skin of the vessel. Complete prior to return to a U. S. port, per SOLAS Chpt II-1 Reg 26(1).
Navigation
Issued 25 January 1995
Resolved
The steering gear is hunting 1-3 degrees either side of rudder commands at lower rudder angles. Provide classification society report on the problem.Make repairs as necessary per SOLAS Chpt II-1 Reg 29(1).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.