01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 December 2024
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. The vessel's dry dock expired 31DEC2024. The vessel will need to complete a dry dock for credit to clear the deficiency.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2025
Resolved 31 January 2025
Resolution: Received objective evidence photos of completion of drydock worklist items.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 February 2024
Resolved
Emergency fuel shutoff valves need to be properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 February 2024
Resolution: Corrected.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 February 2024
Resolved
Upper deck needs placard for total number of passengers allowed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 February 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 March 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 March 2023
Resolution: Interconnected smoke detectors provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 March 2023
Resolved
Inspect bilge pumping arrangements in accordance with 46 CFR 176.804. Bilge pump operation was unsatisfactory. Vessel limited to 49 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2023
Resolution: Observed satisfactory operation of bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2023
Resolved
Inspect propulsion machinery in accordance with 46 CFR 176.804 Excessive oil leak in vicinity of stbd propulsion engine inboard turbo.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2023
Resolved 16 March 2023
Resolution: Leak repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2022
Resolved
If any of the equipment or records for a fixed-gas fire extinguishing system have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. The CO2 cylinders and fittings on the fixed-gas system were corroded. Cylinders must be hydrostatically tested and system must be tested in the presence of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2022
Resolution: Cylinder corrosion was not as bad as first appearance, hydro due in 2024. Test of CO2 system sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] system piping was replaced throughout the vessel without prior approval. Submit repair proposal addressing removal of all non-ferrous piping to vital systems for OCMI review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 11 January 2023
Resolution: Received proposal from vessel rep to accept the nonferrous piping in bilge/fire main system.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 December 2022
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. The FCC station license was expired. Vessel operations limited to within 1000 feet from shore.
Action required: 705 - Other - as specified
Resolved 29 December 2022
Resolution: Owner sent Radio Station Authorization certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 February 2022
Resolved
Inspect lifesaving in accordance 46 CFR 176.808. 07 lifejackets were missing water lights. Limited to 133 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 February 2022
Resolution: Missing water lights provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 February 2022
Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Life jacket retroreflective tape was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Retroreflective tape renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Stbd main engine fuel supply line had soft patch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Soft patch from fuel line removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Rudder jockey bar connections are worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Ruddy jockey bar connections are satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 February 2022
Resolved
Inspect fire equipment in accordance with 46 CFR 176.25-25. Port fire main hanger in engine room at deck penetration is wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Port fire main hanger in engine room at deck penetration was renewed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 February 2022
Resolved
Inspect fire equipment in accordance with 46 CFR 176.25-25. Port fire plug handle is deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Port fireplug handle was renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2022
Resolved
Inspect electrical system in accordance with 46 CFR 176.25-15. Tankless hot water heater power supply is wired to lighting circuit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Tankless hot water heater power supply is wired to individual breaker in sub panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2022
Resolved
Inspect electrical system in accordance with 46 CFR 176.25-15. Battery charger power supply is wired to water pump power circuit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Battery charger power supply is wired to individual breaker in sub panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Generator cooling water hose is unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Generator cooling water hose was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Generator exhaust hose clamps are wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Generator exhaust hose clamps were renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 14 February 2022
Resolved
Conduct sanitary inspections in accordance with 46 CFR 176.25-45. Petroleum products were present in concession area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Petroleum products were removed from concession area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 February 2022
Resolved
Inspect watertight openings in accordance with 46 CFR 176.25-5. Lazzarette hatch gasket is unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 24 February 2022
Resolution: Inspected hatch, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Engine temperature gauges at operating station were inoperative.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2022
Resolved 24 February 2022
Resolution: Engine temperature gauges at operating station were renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Rubber hose was installed in bilge system. Repair by completion Dec 2022 drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 13 December 2022
Resolution: Hoses were removed, however bilge piping was completely replaced using copper. Requested repair proposal to remove non-ferrous piping from vital systems. See activity 7554382.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 February 2022
Resolved
Inspect vessel for hazardous conditions in accordance with 46 CFR 176.25-50. Water tank is secured with tow straps. Fabricate proper mounts by completion of Dec 2022 Drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 8 December 2022
Resolution: Water tank is permanently mounted.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 April 2021
Resolved
Inspect installed fire extinguishing system in accordance with 46 CFR 176.810. Engine room ventilation closures did not close completely.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 23 September 2021
Resolution: Satisfactory ventilation closures provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 April 2021
Resolved
Vessel unable to prove proper operation of fire pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Witnessed satisfactory operation of firepump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2021
Resolved
Vessel unable to prove proper operation of bilge system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Witnessed satisfactory operation of bilge pump from all spaces.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021
Resolved
Vessel is missing railing from upper deck. Install railing as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Upper deck railings installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021
Resolved
Locate fuel tank leakages in stern space and provide repair proposal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Leaks in stern repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
Multiple life jackets missing lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: Life jacket lights provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2021
Resolved
Two life floats beyond serviceability.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2021
Resolution: 02 life floats renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 April 2021
Resolved
Inspect lifesaving equipment in accordance with 46 CFR 176.808. Vessel has life floats capacity for 116 persons. Vessel limited to 116 total persons.
Action required: 705 - Other - as specified
Resolved 14 February 2022
Resolution: Life floats provided for 140 persons.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2021
Resolved
Inspect machinery in accordance with 46 CFR 176.806. Remove power strips from bridge and galley.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 23 September 2021
Resolution: Electrical power strips removed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 April 2021
Resolved
Provide piping for vital systems in accordance with 46 CFR 182.40-5. Renew non-metallic hose at fire pump discharge with metallic pipe at 2022 drydock.
Action required: 705 - Other - as specified
Resolved 13 December 2022
Resolution: Hose was removed, but was replaced with copper piping. Repair proposal requested for removal of all non-ferrous piping in vital systems. See Activity 7554382.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2021
Resolved
Inspect machinery in accordance with 46 CFR 176.804. Remove epoxy and make satisfactory repairs to stbd engine cooling system at 2022 drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2022
Resolution: Repaired thermostat housing was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 May 2020
Resolved
Inboard lower life float needs to be replaced. Passenger count reduced to 119 passengers until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2020
Resolved 26 April 2021
Resolution: Vessel currently has life float capacity for 116 passengers. New 835 issued in activity #7179745.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 May 2020
Resolved
Replace/Renew broken deck board in passenger berthing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Replaced broken deck board in passenger berthing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2020
Resolved
Remove temporary engine room lighting
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Removed temporary engine room lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2020
Resolved
Properly mount potable water tank
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Properly mounted potable water tank.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2020
Resolved
Remove flammable materials in forward void/storage
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Removed flammable materials in forward void/storage
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2020
Resolved
Replace/Renew pressure gauge on fire pump.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Replaced pressure gauge on fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 May 2020
Resolved
Replace/Renew lower inboard lifefloat light.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Replaced lower inboard lifefloat light.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 May 2020
Resolved
Ensure painter is attached to the body of outer lifefloat.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2020
Resolved 14 July 2020
Resolution: Ensured painter is attached to the body of outer lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2020
Resolved
Replace/Renew plug on port life ring
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2020
Resolved 14 July 2020
Resolution: Renewed plug on port life ring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2020
Resolved
Replace/Renew broken outlets in passenger cabin and berthing area.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 17 August 2020
Resolution: Owner replaced broken outlets in passenger acabin andf bething area.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 5 May 2020
Resolved
Replace/Renew 12 volt lighting in berthing area
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Replaced 12 volt lighting in berthing area.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 May 2020
Resolved
Replace loose boards in fore peak.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 14 July 2020
Resolution: Replaced loose boards in fore peak.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2020
Resolved
Ensure all fire stations have valves and wrenches.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2020
Resolved 17 August 2020
Resolution: Owner provided all fire stations have valves and wrenches.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 May 2020
Resolved
Ensure hatch operates as designed on fore peak. Hatch cannot be secured currently.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2020
Resolved 14 July 2020
Resolution: Fore peak hatch was repaired to secured properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 May 2020
Resolved
Ensure hatch operates as designed on lazzerette. Hatch cannot be closed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2020
Resolved 14 July 2020
Resolution: Fore peak hatch was repaired to secured properly.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 5 May 2020
Resolved
Drills had not been conducted/logged since March 18. Ensure all drills are conducted.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 May 2020
Resolved 14 July 2020
Resolution: Conducted underway drills, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2020
Resolved
Replace/Renew passenger count label on upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 17 August 2020
Resolution: Owner provided passenger count lablel for upper deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 May 2020
Resolved
Railing on ladder to upper deck needs to be secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 17 August 2020
Resolution: Owner secured railing on ladder to upper deck.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 May 2020
Resolved
Ensure all navigation lights are operational. Mast light currently extinguished. Vessel cannot operate in reduced visibility until deficiency rectified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2020
Resolved 17 July 2020
Resolution: Mast light operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 May 2020
Resolved
Tighten starboard rudder packing
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 May 2020
Resolved 17 August 2020
Resolution: Owner tightened starboard ruder packing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2020
Resolved
Replace/Renew broken deck light starboard side.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 5 May 2020
Resolved 14 July 2020
Resolution: Replaced broken deck light starboard side.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2020
Resolved
Replace/Renew lifejacket donning placard passenger upper deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 21 August 2020
Resolution: Owner provided lifejacket donning placard on upper deck.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2020
Resolved
Provide proof of watch procedures when carrying overnight passengers prior to carrying overnight passengers
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2020
Resolved 21 August 2020
Resolution: Provided proof of watch procedures when carrying overnight passengers prior to carrying overnight passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 October 2019
Resolved
Required waterlights must be attached around the body of the life float with 3/8" 18 ft line. Vessel had waterlight attached to the grablines.
46 CFR 180.175(f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2019
Resolved 1 October 2019
Resolution: Crew properly attached the waterlights.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2019
Resolved
Portable fire extinguishers are to be intalled to the satisfaction of the OCMI. The extinguisher near engine room exit is not mounted and at risk for damage or accidental discharge.
46 CFR 181.30-10
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2019
Resolved 1 October 2019
Resolution: Crew mounted the fire extinguisher as required.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 1 October 2019
Resolved
Vessels with accommodations below deck must have emergency lighting that actuates upon failure of main lighting system. Vessel cannot carry overnight passengers until cleared.
46 CFR 184.30-5
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2019
Resolved 29 October 2019
Resolution: Owner installed new emergency lighting in passenger spave, tested all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
All wires shall be run as high as practicable above bilges. Current submersible pump located in bilge has dead end wires and live wires are resting in bilge waters.
46 CFR 183.10-20(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 29 October 2019
Resolution: Owner removed all dead wires and live wires in vicinty of the bige pump, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
All electrical installation shall be to satisfaction of [name withheld] to remove or cap all dead end wires under operationg station.
46 CFR 183.01-15.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 29 October 2019
Resolution: All dead wires under operating station were removed or capped, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2019
Resolved
All installations on fuel lines must be supported independently. The fuel filter for generator was mounted with zip ties.
46 CFR 182.455 (b)(7)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 29 October 2019
Resolution: Generator fuel oil filter was mounted properly, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Fuel filters must be installed with a flame shield. The installed filter was missing the flame shield-starboard side engine.
46 CFR 182.455 (b)(6)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 29 October 2019
Resolution: Fuel oil filter was installed with flame shield, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2019
Resolved
The generator heat exchanger was not permanently mounted. It must be installed to satisfaction of OCMI.
46 CFR 182.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 29 October 2019
Resolution: Generator heat exchanger was properly mounted, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 1 October 2019
Resolved
The generator must have guard installed if there is risk of person inadvertently touching it due to location. The guard was missing.
46 CFR 177.35-15.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 29 October 2019
Resolution: Guard was installed on genereator, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
Electrical installations must be installed so as to prevent insulated parts being touched by a person. There are exposed wires on the generator.
46 CFR 183.10-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 29 October 2019
Resolution: Exposed wires on generator were secured properly, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
All switches for equipment shall be of suitable design. Vice grips used as on switch for the generator.
46 CFR 183.10-20(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 29 October 2019
Resolution: Generator switch was properly installed with knob, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Diesel fuel piping if flexible must meet SAE J1942. Hose and fittings must comply with SAE 1475 for factory end fittings.
46 CFR 182.455
46 CFR 182.720
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 29 October 2019
Resolution: Fuel oil hose was replaced with approved hose, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Port engine lube oil leaking onto turbo. All equipment must be maintained to afford adequate protection against fire.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 29 October 2019
Resolution: Lube oil hose was replaced with approved hose and flame shield, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 October 2019
Resolved
All equipment must be maintained so as to prevent fire. Oil in bilges must be removed.
46 CFR 182.100.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 29 October 2019
Resolution: Oil was removed from bilges, bilges were clean and satisfactory.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 March 2019
Resolved
Vessel did not have the required AIS installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 16 April 2019
Resolution: New AIS installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 March 2019
Resolved
Vessel spliced extension cord to fresh water pump for power in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 25 April 2019
Resolution: Vessel hard wired fresh water pump to junction box.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 March 2019
Resolved
Vessel must repair or replace bow and stern flush deck scuttles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 16 April 2019
Resolution: Both scuttles repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 20 March 2018
Resolved
Submit a repair plan to address deck beams in the engine room that have rottten wood and wasted bolts in the ends of the beams.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2018
Resolved 12 April 2018
Resolution: Repairs conducted; all SAT.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 February 2017
Resolved
Navigation lights inoperable repair and have work.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel repaired nav light
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 February 2017
Resolved
Engine Room, too many wires plug into one receptacle, limited to two only. Battery chargers to be removed or hard wired in.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 28 March 2017
Resolution: Vessel completed requirement.
Electrical › Electric Generation Source (service) › Conductor
Issued 13 February 2017
Resolved
Starboard alternator for the engine need to verify it’s for the marine application and if so needs to be cleaned due to excess of oil residue.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel installed new alternator
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 February 2017
Resolved
Generator in engine room is missing guard around belts and pulleys. Mount guard. Port Engine shaft needs covered.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel installed guard and cover
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 February 2017
Resolved
Water lights for both port life floats and starboard life ring topside needs new battery
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel replaced battery
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 February 2017
Resolved
33 life jackets do not have lights; will require lights due to route
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel added lights
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 13 February 2017
Resolved
vessel required a bridge to bridge license, due to the size of the vessel
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 28 March 2017
Resolution: Vessel provided valid certificate
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 February 2017
Resolved
All bilge portable pumps are required to have a visual light written when operating at pilot house
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel repaired and tested system
Navigation › Piloting/Steering › Marine Charts
Issued 13 February 2017
Resolved
Update ships charts and navigation rules
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel provided charts
Documentation › Logs/Records › Logbook (official)
Issued 13 February 2017
Resolved
Vessel is required to have a radio log onboard and logging daily when operating
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 9 March 2017
Resolution: Vessel produced log