← All vessels
VERA MARIE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named VERA MARIE
VERA MARIE is a 1988 passenger vessel (inspected). The Coast Guard has recorded 85 inspections since 1989, most recently in January 2026, along with 200 deficiencies and 2 casualty investigations between 2005 and 2022.
Records from 1989 to 2026. Most recent: inspection, 20 January 2026.
- Built
- 1988
- Last inspected
- 20 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 200 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2005–2022
Identity
941825
WDN5384
320861
Flag
UNITED STATES
367546440
Maury page id
psix-320861
Inspections, by type
…with no type recorded10
Years with a record
35 calendar years (1989–2026)
The 85 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)69.4 ft × 21.1 ft × 8.3 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAN'T MISS OF KEY WEST · KEY WEST, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
65 - Simplified, Net Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN5384MMSI 367546440 · active · compulsorily equipped · granted 20 December 2022, expires 20 December 2032
WDG5416MMSI 367546440 · expired · compulsorily equipped · granted 21 September 2012, cancelled 26 November 2022
WDC3613MMSI 367011180 · expired · compulsorily equipped · granted 14 January 2005, cancelled 21 March 2015 · licensed under a name not among this hull’s recorded names (not shown)
WBO3753MMSI not assigned · expired · compulsorily equipped · granted 7 January 1998, cancelled 19 February 2008 · licensed under a name not among this hull’s recorded names (not shown)
WAB7705MMSI not assigned · expired · compulsorily equipped · granted 28 March 1994, cancelled 29 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 85
20 January 2026
Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8299201
3 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8088005
16 December 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8048121
15 June 2024
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7935612
15 February 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7865896
16 March 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7651769
6 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7646761
4 January 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7616311
3 January 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7615861
8 December 2022
Hull Examination · Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7554382
14 October 2022
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7579101
14 February 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7395005
23 September 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7318744
20 April 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7179745
4 January 2021
Examination of Repairs · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7119214
30 November 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7103563
5 May 2020
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6938849
1 October 2019
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6825330
19 March 2019
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6641784
30 October 2018
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6571459
19 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570657
20 March 2018
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6372947
9 March 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6101647
17 January 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6072294
18 October 2016
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6025128
28 April 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5860531
21 March 2014
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 4821321
7 March 2014
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4811909
7 December 2011
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4203757
29 August 2011
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4126022
7 July 2011
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4069669
3 January 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3919372
8 December 2010
Internal Structural Exam · Drydock Extension · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3907417
19 March 2010
Type not recorded
No type recorded · Station Montauk · USCG Northeast District (CGD-NE) · Activity 3699135
5 March 2010
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3688089
2 March 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3688352
1 December 2009
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3642359
12 November 2008
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3360587
9 October 2008
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3362867
12 September 2007
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3051877
17 May 2007
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2931860
18 January 2006
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2571777
8 December 2005
Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2547992
5 May 2005
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2349973
11 March 2005
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2308084
17 December 2004
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2261090
16 June 2004
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2100414
2 June 2004
Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 2087526
29 March 2004
Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2032983
26 December 2003
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1971008
23 October 2003
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1934237
24 September 2003
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1900786
17 March 2003
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1758443
18 September 2002
COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1676769
3 May 2002
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1682774
3 April 2002
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1600572
12 December 2001
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1474309
19 September 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1362471
3 October 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369862
19 April 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1408527
20 September 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1453671
1 September 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1028975
13 October 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378492
18 September 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378491
17 April 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1124341
24 December 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782675
18 November 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 775156
10 September 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 785711
18 September 1996
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 961169
11 September 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1255314
21 September 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880930
20 April 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163394
22 September 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181913
5 October 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836176
4 May 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146556
20 October 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 827745
20 October 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 940392
29 April 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 958131
15 October 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1249051
6 June 1991
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 898153
11 April 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1220943
24 October 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1250574
21 March 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221336
23 October 1989
Initial Certification · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 907410
19 April 1989
Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1040280
Deficiency record · 200
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 December 2024
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. The vessel's dry dock expired 31DEC2024. The vessel will need to complete a dry dock for credit to clear the deficiency.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 February 2024
Resolved
Emergency fuel shutoff valves need to be properly labeled.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 February 2024
Resolved
Upper deck needs placard for total number of passengers allowed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 March 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 March 2023
Resolved
Inspect bilge pumping arrangements in accordance with 46 CFR 176.804. Bilge pump operation was unsatisfactory. Vessel limited to 49 passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2023
Resolved
Inspect propulsion machinery in accordance with 46 CFR 176.804 Excessive oil leak in vicinity of stbd propulsion engine inboard turbo.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2022
Resolved
If any of the equipment or records for a fixed-gas fire extinguishing system have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. The CO2 cylinders and fittings on the fixed-gas system were corroded. Cylinders must be hydrostatically tested and system must be tested in the presence of the Coast Guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] system piping was replaced throughout the vessel without prior approval. Submit repair proposal addressing removal of all non-ferrous piping to vital systems for OCMI review.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 December 2022
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. The FCC station license was expired. Vessel operations limited to within 1000 feet from shore.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 February 2022
Resolved
Inspect lifesaving in accordance 46 CFR 176.808. 07 lifejackets were missing water lights. Limited to 133 total persons.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 February 2022
Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Life jacket retroreflective tape was unsatisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Stbd main engine fuel supply line had soft patch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Rudder jockey bar connections are worn.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 February 2022
Resolved
Inspect fire equipment in accordance with 46 CFR 176.25-25. Port fire main hanger in engine room at deck penetration is wasted.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 February 2022
Resolved
Inspect fire equipment in accordance with 46 CFR 176.25-25. Port fire plug handle is deteriorated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2022
Resolved
Inspect electrical system in accordance with 46 CFR 176.25-15. Tankless hot water heater power supply is wired to lighting circuit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2022
Resolved
Inspect electrical system in accordance with 46 CFR 176.25-15. Battery charger power supply is wired to water pump power circuit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Generator cooling water hose is unsatisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Generator exhaust hose clamps are wasted.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 14 February 2022
Resolved
Conduct sanitary inspections in accordance with 46 CFR 176.25-45. Petroleum products were present in concession area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 February 2022
Resolved
Inspect watertight openings in accordance with 46 CFR 176.25-5. Lazzarette hatch gasket is unsatisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Engine temperature gauges at operating station were inoperative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.25-10. Rubber hose was installed in bilge system. Repair by completion Dec 2022 drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 February 2022
Resolved
Inspect vessel for hazardous conditions in accordance with 46 CFR 176.25-50. Water tank is secured with tow straps. Fabricate proper mounts by completion of Dec 2022 Drydock.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 April 2021
Resolved
Inspect installed fire extinguishing system in accordance with 46 CFR 176.810. Engine room ventilation closures did not close completely.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 April 2021
Resolved
Vessel unable to prove proper operation of fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2021
Resolved
Vessel unable to prove proper operation of bilge system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021
Resolved
Vessel is missing railing from upper deck. Install railing as original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021
Resolved
Locate fuel tank leakages in stern space and provide repair proposal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
Multiple life jackets missing lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2021
Resolved
Two life floats beyond serviceability.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 April 2021
Resolved
Inspect lifesaving equipment in accordance with 46 CFR 176.808. Vessel has life floats capacity for 116 persons. Vessel limited to 116 total persons.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2021
Resolved
Inspect machinery in accordance with 46 CFR 176.806. Remove power strips from bridge and galley.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 April 2021
Resolved
Provide piping for vital systems in accordance with 46 CFR 182.40-5. Renew non-metallic hose at fire pump discharge with metallic pipe at 2022 drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2021
Resolved
Inspect machinery in accordance with 46 CFR 176.804. Remove epoxy and make satisfactory repairs to stbd engine cooling system at 2022 drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 May 2020
Resolved
Inboard lower life float needs to be replaced. Passenger count reduced to 119 passengers until replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 May 2020
Resolved
Replace/Renew broken deck board in passenger berthing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2020
Resolved
Remove temporary engine room lighting
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2020
Resolved
Properly mount potable water tank
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2020
Resolved
Remove flammable materials in forward void/storage
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2020
Resolved
Replace/Renew pressure gauge on fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 May 2020
Resolved
Replace/Renew lower inboard lifefloat light.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 May 2020
Resolved
Ensure painter is attached to the body of outer lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2020
Resolved
Replace/Renew plug on port life ring
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2020
Resolved
Replace/Renew broken outlets in passenger cabin and berthing area.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 5 May 2020
Resolved
Replace/Renew 12 volt lighting in berthing area
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 May 2020
Resolved
Replace loose boards in fore peak.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2020
Resolved
Ensure all fire stations have valves and wrenches.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 May 2020
Resolved
Ensure hatch operates as designed on fore peak. Hatch cannot be secured currently.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 May 2020
Resolved
Ensure hatch operates as designed on lazzerette. Hatch cannot be closed.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 5 May 2020
Resolved
Drills had not been conducted/logged since March 18. Ensure all drills are conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2020
Resolved
Replace/Renew passenger count label on upper deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 May 2020
Resolved
Railing on ladder to upper deck needs to be secured.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 May 2020
Resolved
Ensure all navigation lights are operational. Mast light currently extinguished. Vessel cannot operate in reduced visibility until deficiency rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 May 2020
Resolved
Tighten starboard rudder packing
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2020
Resolved
Replace/Renew broken deck light starboard side.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2020
Resolved
Replace/Renew lifejacket donning placard passenger upper deck.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2020
Resolved
Provide proof of watch procedures when carrying overnight passengers prior to carrying overnight passengers
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 October 2019
Resolved
Required waterlights must be attached around the body of the life float with 3/8" 18 ft line. Vessel had waterlight attached to the grablines.
46 CFR 180.175(f)(4)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2019
Resolved
Portable fire extinguishers are to be intalled to the satisfaction of the OCMI. The extinguisher near engine room exit is not mounted and at risk for damage or accidental discharge.
46 CFR 181.30-10
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 1 October 2019
Resolved
Vessels with accommodations below deck must have emergency lighting that actuates upon failure of main lighting system. Vessel cannot carry overnight passengers until cleared.
46 CFR 184.30-5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
All wires shall be run as high as practicable above bilges. Current submersible pump located in bilge has dead end wires and live wires are resting in bilge waters.
46 CFR 183.10-20(d)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
All electrical installation shall be to satisfaction of [name withheld] to remove or cap all dead end wires under operationg station.
46 CFR 183.01-15.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2019
Resolved
All installations on fuel lines must be supported independently. The fuel filter for generator was mounted with zip ties.
46 CFR 182.455 (b)(7)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Fuel filters must be installed with a flame shield. The installed filter was missing the flame shield-starboard side engine.
46 CFR 182.455 (b)(6)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2019
Resolved
The generator heat exchanger was not permanently mounted. It must be installed to satisfaction of OCMI.
46 CFR 182.100
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 1 October 2019
Resolved
The generator must have guard installed if there is risk of person inadvertently touching it due to location. The guard was missing.
46 CFR 177.35-15.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
Electrical installations must be installed so as to prevent insulated parts being touched by a person. There are exposed wires on the generator.
46 CFR 183.10-10
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
All switches for equipment shall be of suitable design. Vice grips used as on switch for the generator.
46 CFR 183.10-20(i)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Diesel fuel piping if flexible must meet SAE J1942. Hose and fittings must comply with SAE 1475 for factory end fittings.
46 CFR 182.455
46 CFR 182.720
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Port engine lube oil leaking onto turbo. All equipment must be maintained to afford adequate protection against fire.
46 CFR 182.100
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 October 2019
Resolved
All equipment must be maintained so as to prevent fire. Oil in bilges must be removed.
46 CFR 182.100.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 March 2019
Resolved
Vessel did not have the required AIS installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 March 2019
Resolved
Vessel spliced extension cord to fresh water pump for power in the engine room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 March 2019
Resolved
Vessel must repair or replace bow and stern flush deck scuttles.
Construction/Loadline › Hull › Transverse Frame
Issued 20 March 2018
Resolved
Submit a repair plan to address deck beams in the engine room that have rottten wood and wasted bolts in the ends of the beams.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 February 2017
Resolved
Navigation lights inoperable repair and have work.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 February 2017
Resolved
Engine Room, too many wires plug into one receptacle, limited to two only. Battery chargers to be removed or hard wired in.
Electrical › Electric Generation Source (service) › Conductor
Issued 13 February 2017
Resolved
Starboard alternator for the engine need to verify it’s for the marine application and if so needs to be cleaned due to excess of oil residue.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 February 2017
Resolved
Generator in engine room is missing guard around belts and pulleys. Mount guard. Port Engine shaft needs covered.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 February 2017
Resolved
Water lights for both port life floats and starboard life ring topside needs new battery
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 February 2017
Resolved
33 life jackets do not have lights; will require lights due to route
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 13 February 2017
Resolved
vessel required a bridge to bridge license, due to the size of the vessel
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 February 2017
Resolved
All bilge portable pumps are required to have a visual light written when operating at pilot house
Navigation › Piloting/Steering › Marine Charts
Issued 13 February 2017
Resolved
Update ships charts and navigation rules
Documentation › Logs/Records › Logbook (official)
Issued 13 February 2017
Resolved
Vessel is required to have a radio log onboard and logging daily when operating
Communications › Radio Communications › EPIRB
Issued 7 March 2014
Resolved
Vessel EPIRB has expuired registration, ensure EPIRB is registered to vessel through NOAA.
Construction/Loadline › Structures › Deck Plating
Issued 7 March 2014
Resolved
Repair forward upper deck where stress cracks have occured
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 March 2014
Resolved
Repair exposed wiring from battery switches.
Lifesaving › Lifefloat › Serviceable
Issued 7 March 2014
Resolved
Repair numerous damaged areas of vessels lifefloats. Ensure repairs are made IAW manufacturers recommendations.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 August 2011
Resolved
Ensure crew and operator are in compliance with drug testing program IAW 46 CFR 16 and drills and training IAW 46 CFR 185.420.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 December 2010
Resolved
Failed to schedule and receive credit dry docking IAW provisions of COI. Issued CG-835 to obtain credit or extension prior to carrying passengers.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 March 2010
Resolved
replace retro reflective tape
Lifesaving › Lifefloat › Float-free Link
Issued 5 March 2010
Resolved
Replace both detachable links on life floats, (approval could not be verified)
Construction/Loadline › Structures › Deck Plating
Issued 1 December 2009
Resolved
Replace damaged wood in steering space.
Communications › Alarms/Indicators › Fire Alarm
Issued 1 December 2009
Resolved
Repair/replace fwd smoke alarm.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 December 2009
Resolved
Repair fwd bilge high level alarm light.
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 December 2009
Resolved
Replace missing meter.
Accommodation/Occupational Safety › Potable Water System › General
Issued 1 December 2009
Resolved
Repair water leak by head.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 October 2008
Resolved
Replace cable forward in electrical box
Lifesaving › Lifebuoys › Serviceable
Issued 22 October 2008
Resolved
Replace ring lifebuoy
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 22 October 2008
Resolved
Replace drug test kit for SMI
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 9 October 2008
Resolved
Install (2) smoke detection sensors
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 September 2007
Resolved
Install cover electrical box.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 September 2007
Resolved
Install retro reflective tape one adult life jacket.
Fire Fighting › Firemans Outfit › Axe
Issued 12 September 2007
Resolved
Mount fire axe
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 14 December 2005
Resolved
Make permanent repairs to the bow pulpit area.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 December 2005
Resolved
Make repairs to Stern boarding area . Delamination is starting to occur.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 December 2005
Resolved
Provide guard for STBD aft decklight.
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 December 2005
Resolved
Label emergency fuel shut offs.
Construction/Loadline › Hull › Side Shell
Issued 8 December 2005
Resolved
Make permanent repairs to STBD missing rub rail and attach securely.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 December 2005
Resolved
Ensure that railing course throughout the vessel is securely fatened (eliminate all wobble/play).
Stability › Unintentional Flooding › General
Issued 8 December 2005
Resolved
Prior to the carriage of passengers, make permanent repairs to the Starboard rudder post. Before beginning any repairs, submit a detailed repair proposal to MSD Fort Myers.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 17 December 2004
Resolved
REPAIR AND PROVE PROPER OPERATION OF STARBOARD MAIN ENGINE.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 17 December 2004
Resolved
PROVIDE A CURRENT SAFETY RADIO CERTIFICATE ONBOARD VESSEL.
Electrical
Issued 29 March 2004
Resolved
Re-new bonding throughout vsl.
Pollution Prevention/Response
Issued 29 March 2004
Resolved
Remove all oil and debris from engine room bilge
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2004
Resolved
Re-secure stbd rail course. LEGACY COMPONENT DESC: Deck Rail
Engineering › Steering Gear System › Rudder Bearing
Issued 29 March 2004
Resolved
Tighten rudder shaft packing or re-new bearing
Engineering › Steering Gear System › Bracket/Clamp
Issued 29 March 2004
Resolved
Repair stbd rudder collar for rudder stock on lazarette
Engineering › Steering Gear System › Linkage
Issued 29 March 2004
Resolved
Double nut or cotter pin in place rudder arm.
Construction/Loadline › Hull
Issued 29 March 2004
Resolved
Tighten two (2) keel bolts furthest aft on keel. Re-caulk both interior and exterior fasteners with 3M 5200. LEGACY COMPONENT DESC: Keel
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 September 2003
Resolved
Replace expired PFD lights. LEGACY COMPONENT DESC: Lights
Navigation › Piloting/Steering
Issued 24 September 2003
Resolved
Provide required navigational publications. LEGACY COMPONENT DESC: Navigation Publications
Engineering › Bilge Water Management System
Issued 24 September 2003
Resolved
Provide a visual indicator for each high level alarm. LEGACY COMPONENT DESC: Interface Detector
Lifesaving › Buoyant Apparatus
Issued 24 September 2003
Resolved
Secure all paddles to life floats. LEGACY COMPONENT DESC: Life Float Paddles
Lifesaving › Buoyant Apparatus
Issued 24 September 2003
Resolved
Patch worn areas of life floats and paint faded apparatus with safety orange. LEGACY COMPONENT DESC: Life Float
Lifesaving › Buoyant Apparatus
Issued 24 September 2003
Resolved
Attach water lights to life floats with buoyant u/v resistant line. LEGACY COMPONENT DESC: Water Lights
Communications › Radio Communications
Issued 24 September 2003
Resolved
Register EPIRB for new operator and ensure battery has not yet expired. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Buoyant Apparatus
Issued 24 September 2003
Resolved
Replace worn retro reflective tape on life floats. LEGACY COMPONENT DESC: Life Float Retro Reflective Tape
Lifesaving › Lifejacket/PFD (General)
Issued 24 September 2003
Resolved
Label topside PFD storage boxes number and type of PFDs. LEGACY COMPONENT DESC: Storage Labeling
Electrical › Electrical Distribution System (service)
Issued 24 September 2003
Resolved
Remove dead-end wiring inside and just aft of wheel house. LEGACY COMPONENT DESC: Wiring
Documentation › Markings/Placards
Issued 24 September 2003
Resolved
Provide a label for top deck indicating the maximum number of passengers allowed. LEGACY COMPONENT DESC: Capacity Marking Upper Deck
Engineering › Bilge Water Management System
Issued 24 September 2003
Resolved
Re-attach engineroom electrical bilge pump hose to through-hull fitting. LEGACY COMPONENT DESC: Hose
Engineering › Fuel Oil Storage/Transfer System
Issued 24 September 2003
Resolved
Tighten fuel pick-up piping to starboard side fuel tank. LEGACY COMPONENT DESC: Piping
Stability › Unintentional Flooding
Issued 24 September 2003
Resolved
Remove water from lazarette bilge. LEGACY COMPONENT DESC: Water in Bilge
Operations/Management › Drug and Alcohol Testing
Issued 24 September 2003
Resolved
Provide proof of drug testing program. LEGACY COMPONENT DESC: Proof of Enrollment
Electrical › Electric Supply System (service)
Issued 18 September 2002
Resolved
Provide battery cover. LEGACY COMPONENT DESC: Battery Installation
Electrical › Electrical Distribution System (service)
Issued 18 September 2002
Resolved
Remove all dead-end wiring from engine room. LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service)
Issued 18 September 2002
Resolved
Install pressure connector type fittings to all wiring as discussed with Marine Inspector. LEGACY COMPONENT DESC: Wiring
Engineering › Bilge Water Management System › Pump
Issued 18 September 2002
Resolved
Prove proper operation of bilge pumps not later than 28Sep02. (small amount of oily water in bilge at time of inspection that owner was to remove before testing.)
Communications › Alarms/Indicators
Issued 18 September 2002
Resolved
Install and prove proper operation of audible high level alarms in lazarette and engine room not later than 25Sep02. LEGACY COMPONENT DESC: High Water Alarm
Lifesaving › Lifebuoys
Issued 18 September 2002
Resolved
Repair all life floats in accordance with 46 CFR part 160.
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 September 2002
Resolved
Renew first aid kit in accoradance with 46 CFR 160.041 and 46 CFR 184.710.
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 September 2002
Resolved
Renew retro-reflective material on 34 adult PFDs and lights on 9. The vessel is restricted to 110 adults and 16 children until corrected. LEGACY COMPONENT DESC: Retroreflective Material
Electrical › Electrical Distribution System (service)
Issued 18 September 2002
Resolved
Remove or permanently install junction box and dead end wiring in #3 compartment. LEGACY COMPONENT DESC: Junction Box
Construction/Loadline › Hull
Issued 3 April 2002
Resolved
REPAIR 1ftx1ft AREA OF FRP LOCATED EXTERIOR HULL, PORT SIDE WHERE MEETS TRANSOM. LEGACY COMPONENT DESC: Hull Plating
Accommodation/Occupational Safety › Occupational Safety
Issued 3 April 2002
Resolved
STRENGTHEN ENTIRE LENGTH OF STBD SIDE MAIN DECK RAIL, IAW 46CFR 177.900(b) LEGACY COMPONENT DESC: Deck Rail
Engineering › Bilge Water Management System
Issued 3 April 2002
Resolved
INSTALL OVERBOARD DISCHARGE VALVES IN THROUGHHULL FITTINGS WITHIN 6 INCHES OF THE WATERLINE. IN PARTICULAR THE BILEGE DISCHARGE PIPES ON STBD SIDE FWD PART OF MACHINERY SPACE. LEGACY COMPONENT DESC: Valve
Engineering › Sea-water System (primary cooling)
Issued 3 April 2002
Resolved
REPLACE PORT AND STBD MAIN DIESEL ENGINE RAW WATER COOLING INTAKE VALVES. VALVES ARE SHOWING SIGNS OF ELECTROLYSIS CORROSION. LEGACY COMPONENT DESC: Valve
Electrical › Lighting (service)
Issued 3 April 2002
Resolved
REPLACE BROKEN GLOBE ON LIGHT FIXTURE IN MACHINERY SPACE. LEGACY COMPONENT DESC: Lighting Fixture
Accommodation/Occupational Safety › Occupational Safety
Issued 3 April 2002
Resolved
DECK RAILING FOR UPPER DECK IS ONLY 36 INCHES HIGH. SUBMIT SIGNED STATEMENT TO MSD FT MYERS ATTESTING THAT PASSENGERS FISH OFF THE TOP DECK AND WILL NOT BE USED FOR EXCURSION VOYAGES. THIS WILL ALLOW VESSEL TO RETAIN EXISTING RAILS, OTHERWISE INSTALL RAILS IAW 46CFR 177.900(1). LEGACY COMPONENT DESC: Deck Rail
Construction/Loadline
Issued 19 September 2001
Resolved
Re-attach captive chain on aft deck hatch.
Lifesaving
Issued 19 September 2001
Resolved
Properly attach waterlight to ringbuoy with lanyard 3-6 ft. in length.
Electrical
Issued 19 September 2001
Resolved
Install covers over batteries for S/S generator.
Construction/Loadline
Issued 19 September 2001
Resolved
Renew flexible hose for bilge pump in forward accommodation space with wirereinforced hose.
Navigation
Issued 19 September 2001
Resolved
Repair and demonstrate proper operation of air horn.
Lifesaving
Issued 19 September 2001
Resolved
Add Richard Houde to list provided by THE MARITIME CONSORTIUM of crewmembers enrolled in chemical testing program.
Lifesaving
Issued 19 September 2001
Resolved
Provide a logbook with proper entries for conducting drills and inspection & testing of lifesaving equipment.
Construction/Loadline
Issued 19 September 2001
Resolved
Repair dogging mechanism on forward deck hatch.
Navigation
Issued 19 September 2001
Resolved
Demonstrate proper operation of SSB Radio.
Lifesaving
Issued 3 October 2000
Resolved
Provide copy of annual consortium contract (CY2000) for review.
Electrical
Issued 3 October 2000
Resolved
Provide crimp style connectors on electrical connections on bilge h/w alarmin engineroom; light over stbd main engine; winch motor.
Lifesaving
Issued 3 October 2000
Resolved
Register EPIRB w/NOAA.
Lifesaving
Issued 3 October 2000
Resolved
Repair/renew netting in all lifefloats. Provide SOLAS Type retro- reflective tape where required.
Lifesaving
Issued 20 September 1999
Resolved
Conduct man ovbd & fire drill in presence of CG inspector.
Construction/Loadline
Issued 20 September 1999
Resolved
Repair/renew high water alarm in engineroom. Ensure audible/visual capability @ operating stations.
Electrical
Issued 20 September 1999
Resolved
Properly install generator start battery.
Engineering
Issued 20 September 1999
Resolved
Properly affix hose clamps on the main engine intakes.
Engineering
Issued 20 September 1999
Resolved
Install vent closures for engine compartment.
Lifesaving
Issued 18 September 1998
Resolved
Provide results of drug testing program.
Documentation
Issued 18 September 1998
Resolved
Provide copy of FCC Operator's License.
Lifesaving
Issued 18 September 1998
Resolved
Provide log for drills/training.
Electrical
Issued 18 September 1998
Resolved
Repair broken ground in #2 and aft steering compartments.
Accommodation/Occupational Safety
Issued 18 September 1998
Resolved
Tighten upper deck hand rails, port and starboard side.
Lifesaving
Issued 18 September 1998
Resolved
Properly mark PFD stowage location on upper deck.
Navigation
Issued 18 September 1998
Resolved
Repair leak on stbd rudder packing gland.
Construction/Loadline
Issued 18 September 1998
Resolved
Properly mark fixed bilge system manifold.
Construction/Loadline
Issued 18 September 1998
Resolved
Repair/renew leak on fixed bilge system & prove proper operation.
Lifesaving
Issued 10 September 1997
Resolved
Renew retro-reflective tape on all 4 lifefloats and stencil paddles with vessel's name.
Engineering
Issued 10 September 1997
Resolved
Repair cooling water leak on S/S generator.
Electrical
Issued 10 September 1997
Resolved
Re-install alternator bracket on S/S generator.
Lifesaving
Issued 10 September 1997
Resolved
Renew battery in EPIRB.
Electrical
Issued 20 April 1995
Resolved
Correctly wire light in weathertight electrical box in way of ladder leading from main to second deck.
Construction/Loadline
Issued 20 April 1995
Resolved
Repair glass seperation on main deck in way of the most aft freeing ports on port and starboard sides._x001C_ All other similar areas found unaffected.
Lifesaving
Issued 22 September 1994
Resolved
Provide one additional child PFD to bring total onboard to 16.
Electrical
Issued 22 September 1994
Resolved
Remove wire nuts in power feed to F/W pump and place in enclosure after properly joining them.
Engineering
Issued 22 September 1994
Resolved
Install two hose clamps on each end of stuffing box tube.
Construction/Loadline
Issued 22 September 1994
Resolved
Repair leaking bilge pump discharge hose located in aft berthing area.
Documentation
Issued 5 October 1993
Resolved
Paint draft marks on vessel fore and aft.
Electrical
Issued 20 October 1992
Resolved
LOCATE MOTOR CONNECTED TO LAZARETTE LIGHT SWITCH AND PROVIDE SEPARATE SWITCH FOR SAME._x001C_ _x001C_ _x001C_
Lifesaving
Issued 20 October 1992
Resolved
PROVIDE 5 ADDITIONAL PADDLES FOR LIFEFLOATS_x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 21 March 1990
Resolved
REPLACE ALL BILGE O/B LINES (PVC TUBE) WITH WIRE REINFORCED HOSE.
Engineering
Issued 21 March 1990
Resolved
MAKE REMOTE FUEL SHUTOFFS OPERABLE FROM OUTSIDE THE TANK SPACE IAW 46 CFR 182.20-40(B)(3).
Engineering
Issued 21 March 1990
Resolved
REMOVE ENGINE S/W OVBD THRU-HULLS WITH METALLIC THRU HULLS 46 CFR 182-40- 1(A)(3).
Construction/Loadline
Issued 21 March 1990
Resolved
PROVIDE CAPTIVE CHAINS FOR ALL WEATHER DECK HATCHES.
Documentation
Issued 21 March 1990
Resolved
POST STABILITY LETTER IN THE WHEELHOUSE SO THAT BOTH PAGES OF LETTER ARE VISABLE.
Construction/Loadline
Issued 21 March 1990
Resolved
MAKE THE COLLISION BLKHD WATERTIGHT IWO THE WIRING PENETRATION.
Construction/Loadline
Issued 21 March 1990
Resolved
MAKE THE FRESHWATER PVC BULKHEAD PENETRATION THROUGHT THE REQUIRED WATERTIGHT BULKHEAD AT FR 29. COMPLY WITH 46 CFR 182.40-1(A).
Deck/Cargo
Issued 21 March 1990
Resolved
PROPERLY BRACKET ALL PVC PIPE FOR BILGE OVERBOARD LINE.
Casualty record · 2
5 May 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 2349973
14 October 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7579101
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
FISH'N XPRESS III (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.