MAURY USCG vessel records Sign in
← All vessels

AQUEOS ACADIAN

AQUEOS ACADIAN is a 1973 industrial vessel. The Coast Guard has recorded 34 inspections since 1989, most recently in May 2016, along with 33 deficiencies and 7 casualty investigations between 2006 and 2014.

Records from 1989 to 2016. Most recent: inspection, 3 May 2016.

Built
1973
Last inspected
3 May 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7366805 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF9603
321041
Flag
UNITED STATES
367116090, 368070000 (licence lapsed)
Maury page id
psix-321041

Inspections, by type

…with no type recorded14
Years with a record 16 calendar years (1989–2016)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it291 - Regulatory (Subpart C or D), Gross Ton
1138 - Convention (Subpart B), Gross Ton
198 - Regulatory (Subpart C or D), Net Ton
341 - Convention (Subpart B), Net Ton
1258 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF9603MMSI 368070000 · expired · compulsorily equipped · granted 14 October 2011, cancelled 18 December 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDD2502MMSI 367116090 · expired · compulsorily equipped · granted 20 May 2006, cancelled 23 July 2016
WCX4784MMSI not assigned · expired · compulsorily equipped · granted 15 May 1997, cancelled 22 July 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

3 May 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6142533
8 September 2015 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5734529
25 March 2014 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4822573
24 March 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4821971
28 September 2011 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4156667
7 September 2011 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4138751
16 November 2010 Examination of Repairs · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3892287
8 May 2009 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3470322
16 October 2008 MTSA Verification · Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3346106
11 June 2008 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3233628
4 June 2008 Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3227834
25 April 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3205412
17 April 2008 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3186449
27 November 2007 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3105168
10 October 2007 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3076688
18 September 2006 MTSA Verification · Initial Certification · Hull Examination · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2781354
8 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2739618
10 September 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766188
30 August 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 198440
23 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419747
17 November 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 671425
12 November 1997 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 776925
12 November 1997 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1110029
22 October 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409235
30 September 1997 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 781980
20 August 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1464704
3 February 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 668597
1 February 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 214155
14 August 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 49425
19 March 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 91455
3 February 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 8762
31 January 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 668598
5 January 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 146648
29 November 1989 Inclining Experiment · Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 900211

Deficiency record · 33

Communications › Internal Communications System › Sound-powered Telephone
Issued 8 September 2015 Resolved
Sound powered phone on #1 Pressure Vessel for Human Occupancy (PVHO) was not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 9 September 2015
Resolution: Sound powered phone was fixed and tested to verify.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 8 September 2015 Resolved
Replace plastic trash can in galley with metal trash can.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 9 September 2015
Resolution: Metal trash can was placed galley.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 September 2015 Resolved
Emergency light fixture in generator space did not function.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 9 September 2015
Resolution: Verified function of light.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2015 Resolved
Remove light in generator or permanently install.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 9 September 2015
Resolution: Light was removed.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 September 2015 Resolved
Overspeed on #2 generator needs to be adjusted.
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 8 September 2015
Resolution: Witnessed proper operation of overspeed device.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 8 September 2015 Resolved
Battery box vents in generator space were painted over.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 9 September 2015
Resolution: Vents in battery boxes were cleared.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 8 September 2015 Resolved
Fix oil leak on #1 generator prime mover.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 9 September 2015
Resolution: Verified oil leak was fixed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 September 2015 Resolved
Install interlock slidebar on generator switchboard.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 14 September 2015
Resolution: Verified installation of interlock on switchboard.
Construction/Loadline › Structures › Superstructure
Issued 25 March 2014 Resolved
Port bow superstructure bent, inset, and cracked, and satellite tower bent due to collision with offshore platform South Pelto 5. Repairs as original during scheduled dry dock beginning the week of 31 March 2014 and prior to operating.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 12 May 2014
Resolution: Repairs complete.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 March 2014 Resolved
Deck rails damaged on port bow superstructure due to collision with offshore platform South Pelto 5. Repairs as original during scheduled dry dock beginning the week of 31 March 2014 and prior to operating.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 12 May 2014
Resolution: Repairs complete.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 25 March 2014 Resolved
Port bow dive anchor and structure missing due to collision with offshore platform South Pelto 5. Repairs as original during scheduled dry dock beginning the week of 31 March 2014 and prior to operating.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 12 May 2014
Resolution: Repairs complete.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 28 September 2011 Resolved
Operator requests increased manning, but does not have adequate capacity for 40 persons on the Stbd side of vsl. Vsl must have 100% Liferaft capacity on each side of the vsl.
Due 28 October 2011
Resolved 7 November 2011
Resolution: Item cleared.
Stability › Watertight Integrity › General
Issued 5 June 2008 Resolved
Make the vessel available for a CG Marine Inspector to look at the damage on the Port Bow Stem in the next 30 days.
Due 4 July 2008
Resolved 6 June 2008
Resolution: Only minor damage noted to bull works.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 27 November 2007 Resolved
Hydrostatic release units were expired. Procure and install new Hydrostatic releases prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2007
Resolution: New Hydrostatic releases installed and marked with appropriate date.
Communications › Visual Communication › Red Warning Signal
Issued 27 November 2007 Resolved
Repair aft red warning light in generator room for general alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2007
Resolution: Red light repaired
Stability › Watertight Integrity › General
Issued 21 November 2007 Resolved
Vessel has PVC piping through bulkheads and decks in cargo, steering and engine room compartments. You shall install metallic sleeves where the PVC pipes penetrates the bulkheads, with valves installed on both sides of bulkhead, unless remote operated valve is used on one side of bulkhead. The installation shall be to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 17 April 2008
Communications › Audible Communications › Bell
Issued 20 November 2007 Resolved
Procure and install correct size bell appropriate for size of vessel.
Due 20 December 2007
Resolved 22 February 2008
Resolution: New bell installed.
Communications › Audible Communications › Horn/Whistle
Issued 20 November 2007 Resolved
Procure and install new ships whistle with correct audible charteristics.
Due 20 December 2007
Resolved 22 February 2008
Resolution: New whistle installed
Engineering › Compressed Air System (start air) › Valve
Issued 20 November 2007 Resolved
Test or renew PRV's on air recevers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2008
Resolution: New PRV''s purchased and installed.
Engineering › Steering Gear System › Pin
Issued 20 November 2007 Resolved
Pins for rudder arms and rams do not have keepers or pins to maintain seated position. Install pins or keepers to ensure pns stay in place.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2007
Resolution: Pins and keepers installed were required.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 20 November 2007 Resolved
Fuel tanks on anchor windlass are not vented. Provide vents for fuel tanks.
Due 21 November 2007
Resolved 21 November 2007
Resolution: Vents were added to fuel tanks.
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
DWG # C-4631-1 Rev 2 Tonnage Frame Arrangment & Detail. Reviewed by ABS. Plans need review and approval from the Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg # C-4631-2 Rev. 1 New sea chest arrangement and detail. Reviewed by ABS. Must be sent to Marine safety center for review and approval
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg # C-4631-A10 REV. 0 Anchor Handling arrangement and detail. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg # C- 4631-S3 REV. 1 Tonnage Opening Modification. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
C- 4631-S2 REV. 2 A-Frame foundation. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg # C-4631-S17 REV. 0 Deck fitting foundations. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg# C-4631-S23 REV. 0 Rescue boat davit installation. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg# C4631-S24 Rev. 1 Winch installation. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg# C-4631-S29 Rev. 0 Anchor Bolster Details Sht 1. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg# C-4631-S29 Rev. O Anchor Bolster Details sht 2 Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 23 October 2006
Resolution: Approved
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
dwg# C-4631-P1 REV. 0 Tank conversion. Reviewed by ABS. Must be reviewed and approved by Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 20 November 2007
Resolution: Tank conversion drawing was revewed and approved by MSC
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 October 2006 Resolved
Plan Approval for fixed Halon system. Must have plan review and approval from Marine Safety Center.
Action required: 705 - Other - as specified
Due 6 October 2009
Resolved 19 October 2009
Resolution: System removed and will not be re-installed.

Casualty record · 7

22 November 2006Routine · role: Involved in a Marine Casualty · activity 2829108
22 November 2006Routine · role: Involved in a Marine Casualty · activity 2876312
25 April 2008Routine · role: Involved in a Marine Casualty · activity 3205412
25 April 2011Routine · role: Involved in a Marine Casualty · activity 3996519
21 April 2013Routine · role: Acknowledged Pollution Source · activity 4589980
17 January 2014Routine · role: Subject of Search and Rescue · 1 injured · activity 4784789
24 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4821971
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

OCEAN VERITAS (2006–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.